Megger MIT400 Insulation and Continuity Tester

Megger_Logo_ssml

The new Megger MIT400 insulation and continuity tester has been designed for electrical testing by power utilities, industrials, telecommunication companies, commercial/domestic electricians and anyone with unique test voltage requirements. The features of the MIT400 also make it ideal for maintenance technicians and engineers.

PDF Logo    MIT400 Datasheet

 

If you would like more information regarding this product, simply email us here.
  • This field is for validation purposes and should be left unchanged.
SKU: Megger MIT400 Categories: , Tags: ,

Megger MIT400 Features:

  • CAT IV 600 V rating – provides greater safety when testing at higher voltage levels
  • Adjustable insulation test voltages – provides 250 V to 1000 V or 50 V to 1000 V.
  • Dual digital display readout – allows display of complimentary test information simultaneously (for example: M½ plus test voltage or M½ plus leakage current)
  • Digital and analogue arc display – includes not only the digital readout but also Megger’s patented analog arc to replicate the response of a moving coil display
  • Exceptional measurement range from 20 G½ to 200 G½ – highest insulation test range available on the market, providing a superior range of measurement applications.
  • Choice of 20 mA or 200 mA continuity testing – allows user to select lower continuity range thus increasing battery life considerably
  • Continuity auto-test capability – enables real twohanded operation without the need to press the test button
  • Adjustable continuity limit alarm – allows pass/fail limits to be sent to speed testing
  • Automatically perform PI and DAR tests – user is able to quickly perform two important diagnostic tests. . . Polarization Index (PI) and Dielectric Absorption Ratio (DAR)
  • True RMS voltage measurement – allows accurate voltage measurement on noisy lines
  • Auto ranging voltage measurement – automatically adjusts range from millivolts to 600 V AC or DC,
  • eliminating the need to keep changing ranging
  • Live circuit warning – automatically warns of contact to a live circuit, voltage is displayed and testing is inhibited
  • Auto fuse warning – warns of fuse failure automatically.
  • No need to test the fuse manually.
  • Buzzer select button – enable or disable buzzer as required with resistance also displayed on the screen

Megger MIT400 Specifications

*All quoted accuracies are at +20° C.
Insulation Nominal test voltages 250 V, 500 V, 1000 V
Insulation resistance range 20 GΩ
Range Full Scale Accuracy 1000 volts ±3% ±2 digits ±0.2% per GΩ
500 volts ±3% ±2 digits ±0.4% per GΩ
250 volts ±3% ±2 digits ±0.8% per GΩ
Analog range 1 GΩ full scale
Short Circuit Current 2 mA +0% -50%
Terminal voltage -0% +20% ±1 V
Test Current on load 1 mA at min. pass value of insulation specified in BS7671, HD384and IEC364, 2 mA max.
EN61557 Operating range 0.10 M½ to 1.00 GΩ
Leakage Current 10% ±3 digits
Voltage display 3% ±3 digits ±0.5% of rated voltage
Polarization Index (PI) 10 min/1 minute ratio
Dielectric Absorption Ratio (DAR) 60 sec/30 sec ratio
Notes (1) All ranges measure from 0.00 M½ upwards.
(2) Above specifications only apply when high quality silicone leadsare being used.
Continuity
Measurement 0.01 ½ to 99.9 ½ (0 to 100 ½ on analogue scale)
Accuracy ±3% ±2 digits (0 to 100 Ω)
Open circuit voltage 5 V ±1 V
Test current 200 mA (–0 mA +20 mA)
(0.01 ½ to 9.99 Ω)
20mA (±1 mA )
(10.0 ½ to 99.9 Ω)
Zero offset at probe tips 0.10Ω typical
Lead resistance zeroing Up to 9.00 Ω
Buzzer Variable limit 1Ω, 2Ω, 5Ω,10Ω, 20Ω
Resistance
Measurement 0.01 kΩ to 1000 kΩ
(0 to 1 MΩ on analog scale)
Accuracy ±3% ±2 digits
Open circuit voltage 5 V ±1 V
Short circuit current 20 µA ± 5 µA
Voltage range 0 to 600 V d.c. ±2% ±2 digits
10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits
0 to 1000 V on Analog scale
Unspecified input level 0 – 10 mV (40 to 400 Hz)For non-sinusoidal waveforms additional specification apply:
±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter Operates at >25 V a.c. or d.c. on any range except OFF
Frequency 40 – 450 Hz (40 Hz – 99.9 Hz)
±0.5% ±1 digit (100 Hz to450 Hz)
Result storage
Capacity >1000 test results
Download Bluetooth wireless
Bluetooth Class Class II
Range up to 10 m
Power
Power Supply 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used.
Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Dimensions
Instrument 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument and case 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Weight
Instrument only 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot
Instrument and case 1.75kg (3.86 lb)
Fuse Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of highbreaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.
Safety Protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
E.M.C. In accordance with IEC 61326 including amendment No.1
Temperature effects
Temperature coefficient <0.1&Omega per °C up to 1 G&Omega
Environmental
Operating range -10 to +55° C
Operating humidity 90% RH at 40° C max.
Storage temperature range -25 to +70° C
Calibration Temperature +20° C
Maximum altitude 2000 m
Dust and water protection IP54 Protected against dust and splashing water