<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Current Transducers Dataloggers Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/ht-italia/current-transducers-dataloggers/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/ht-italia/current-transducers-dataloggers/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Sun, 19 Dec 2021 14:00:20 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Current Transducers Dataloggers Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/ht-italia/current-transducers-dataloggers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</title>
		<link>https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:58:07 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2845</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<p>The XL424 is a 3 phase Voltage data logger that is capable of performing measurements and recordings of TRMS AC voltage up to 600V. It has a sophisticated memory algorithm allowing it to record for up to 90 days</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/">HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL424 can perform measurements and recording of True-Rms AC voltage up to 600 volts in a three phase three-wire system. Applications include evaluation of network voltages and unbalanced loads etc. The instrument is contained in a safety IP65 case with built-in test leads and safety alligator clips for voltage measurements. The system can record for a very long time, up to around 90 days. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<h4><span style="font-size: large;">HT Italia XL424 Functions:</span></h4>
<ul>
<li>True-rms AC voltage measurement up to 600V.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Set of two alligator clips, KITXL423C.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
<table id="table88" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">0 Volts to 600 Volts</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">0.1 Volt</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(1.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><i>Note: meter consider null readings &lt; 2 volts</i></td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
1.5 days/1 sec; 8 days/6 sec; 42 days/30 sec; 91 days/1 min;<br />
455 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">120mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Test Lead Length</td>
<td bgcolor="#C0C0C0">2.6 meters</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/">HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</title>
		<link>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:52:46 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2843</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<p>The HT Italia XL423 is a single phase voltage date logger capable of performing measurements and recordings of TRMS AC voltage up to 600V. It has a sophisticated memory algorithm which allows it to record for up to 1 year.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/">HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL423 can perform measurements and recording of True-Rms AC voltage up to 600 volts in a single phase system. Applications include evaluation of network voltages and unbalanced loads etc. The instrument is contained in a safety IP65 case with built-in test leads and safety alligator clips for voltage measurements. The system can record for a very long time, up to around a year. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<table id="table77" border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="42%">
<h4><span style="font-size: large;">HT Italia XL423 Functions:</span></h4>
<ul>
<li>True-rms AC voltage measurement up to 600V.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<p>&nbsp;</p>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Set of two alligator clips, KITXL423C.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
</td>
</tr>
<tr>
<td colspan="2" valign="top" width="79%">
<div align="center">
<table id="table80" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">0 Volts to 600 Volts</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">0.1 Volt</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(1.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><i>Note: meter consider null readings &lt; 2 volts</i></td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
5 days/1 sec; 34 days/6 sec; 170 days/30 sec; 364 days/1 min;<br />
1820 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">120mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Test Lead Length</td>
<td bgcolor="#C0C0C0">2.6 meters</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/">HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL421 True-Rms AC  Single-Phase Current Logger</title>
		<link>https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:45:28 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2841</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<div class="product-meta">
<div class="product-description">
<p>The HT Italia XL421 is a single phase current data logger capable of performing TRMS AC current measurements and recordings up to 2500A. It has a sophisticated memory algorithm which permits the instrument to record for up to a year.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
</div>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/">HT Italia XL421 True-Rms AC  Single-Phase Current Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL421 can perform measurements and recording of True-Rms AC current up to 2500 amps in a single phase system. Applications include evaluation of load consumption, verification of nominal power of transformer, etc. The instrument is contained in a safety IP65 case with built-in flexible clamp which is easily connected to a variety of cable and bus-bar sizes. The system can record for a very long time, up to around a year. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<h4><span style="font-size: large;">HT Italia XL421 Functions:</span></h4>
<ul>
<li>True-rms AC current measurement up to 2500A.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<p>&nbsp;</p>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Inbuilt/integrated 3000 amp flexible current clamp, type HTFLEX33DL.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
<table id="table72" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">2 amps to 2500 amps</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">1 amp</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(2.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Accuracy Error</td>
<td bgcolor="#C0C0C0">additional error due to not centering cable: 2% of reading</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
5 days/1 sec; 34 days/6 sec; 170 days/30 sec; 364 days/1 min;<br />
1820 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">129mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Conductor Diameter</td>
<td bgcolor="#C0C0C0">174mm</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/">HT Italia XL421 True-Rms AC  Single-Phase Current Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL422 3-Phase Current Datalogger</title>
		<link>https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:37:08 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2839</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<p>The XL422 is a 3 phase current data logger able to perform TRMS AC measurements and recordings of current up to 2500A. This instrument has a sophisticated memory algorithm which allows it to record for up to 1 year.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/">HT Italia XL422 3-Phase Current Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>HT Italia XL422 Three-phase Current Data Logger</strong></p>
<p>The HT Italia XL422 performs measurements and records TRMS AC current up to 2500A in a generic three phase 3-wire system.</p>
<p>The XL422 is part of the HT Data Logger family which includes the following models: XL421, XL423 and XL424</p>
<p>These models can perform measurements and recordings of TRMS AC current up to 2500A from a generic single-phase system.</p>
<p>They can be very useful for various applications:</p>
<ul type="disc">
<li>evaluation of load consumption</li>
<li>verification of nominal power of the incoming supply</li>
</ul>
<p>The instrument is enclosed in a safe and practical case with a built-in flexible clamp enabling you to clamp-on to a cable or bar with wide dimensions.</p>
<p>Thanks to a sophisticated memory algorithm the instrument is able to record for a considerable time, up to about 1 year! (With a 60 sec integration period for single phase loggers and 5 min integration for 3 phase loggers dependant on battery life). It is also simple and straight forward to use.</p>
<p>With TOPVIEW2004 Windows software, supplied with the model, it’s possible to download and analyse all recorded data directly on your PC.</p>
<p>The high-protection (IP65) casing makes the instrument reliable to use in extreme environmental conditions.</p>
<h4><strong>HT Italia XL422 Function:</strong></h4>
<ul>
<li>TRMS AC current measure up to 2500A</li>
<li>Recording with sampling programmable period</li>
<li>Manual activation of recording</li>
<li>Low battery indication</li>
<li>LED indication of any operation</li>
<li>RS-232 interface</li>
<li>Data maintaining without batteries</li>
<li>Programming with software</li>
</ul>
<table id="table80" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">2 amps to 2500 amps</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">1 amp</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(2.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Accuracy Error</td>
<td bgcolor="#C0C0C0">additional error due to not centering cable: 2% of reading</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
5 days/1 sec; 34 days/6 sec; 170 days/30 sec; 364 days/1 min;<br />
1820 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">129mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Conductor Diameter</td>
<td bgcolor="#C0C0C0">174mm</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/">HT Italia XL422 3-Phase Current Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>