<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electrical Testers Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/ht-italia/electrical-testers-ht-italia/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/ht-italia/electrical-testers-ht-italia/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Thu, 05 Feb 2026 21:41:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Electrical Testers Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/ht-italia/electrical-testers-ht-italia/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HT ITALIA NEPTUNE Multimeter/Insulation Tester</title>
		<link>https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 19 Jun 2019 04:41:26 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=36329</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg"><img class="alignnone size-full wp-image-3842" src="https://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="" width="166" height="91" /></a></p>
<h4>HT ITALIA NEPTUNE Features:</h4>
<ul>
<li><span style="font-size: 90%;">Autorange function &#38; automatic detection of AC, DC for all measurements.</span></li>
<li><span style="font-size: 90%;">Insulation test voltages of 50,100,250,500,1000VDC</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS voltage up to 1000V.</span></li>
<li><span style="font-size: 90%;">Low-impedance LoZ input to eliminate “stray voltages” from the measurement</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS current by means of an optional external current clamp</span></li>
<li><span style="font-size: 90%;">Measurement of voltage or current frequency.</span></li>
<li><span style="font-size: 90%;">Resistance and continuity with buzzer.</span></li>
<li><span style="font-size: 90%;">MAX/MIN/PEAK/HOLD functions.</span></li>
<li><span style="font-size: 90%;"> CAT IV 600V, CAT III 1000V Safety Rating</span></li>
<li><span style="font-size: 90%;">ISO 9000 Calibration Certificate included</span></li>
<li><span style="font-size: 90%;">Similar to the Fluke 1587 &#38; Fluke 1577</span></li>
</ul>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>     <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-Datasheet.pdf" rel="noopener noreferrer">NEPTUNE Datasheet</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-Brochure.pdf" rel="noopener noreferrer">NEPTUNE Brochure</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-User-Manual.pdf" rel="noopener noreferrer">NEPTUNE User Manual</a></span></h3>
<p>The post <a href="https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/">HT ITALIA NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT ITALIA NEPTUNE Multimeter/Insulation Tester is a mix of technology that includes an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), an Harmonics analyzer and a True  RMS multimeter.</p>
<h4>HT ITALIA NEPTUNE Key Features:</h4>
<ul>
<li>it can quickly measure insulation up to 1000V, just like top-of-the-range testers.</li>
<li>50,100,250,500,1000VDC Insulation test voltages.</li>
<li>it measures continuity of protective conductors with 200mA to solve the most common problems related to masses.</li>
<li>measure Inrush currents, Harmonics and THD%, just like top-of-the-range power quality analyzers.</li>
<li>with a wide range of external clamp transducers it can measure AC TRMS, DC, AC+DC current and Inrush current, starting from 1mA up to 3000A.</li>
<li>compare each measurement with the limits prescribed by the Guidelines and I provide a clear result OK or NOT OK</li>
<li>it&#8217;s a multimeter with functions only available if using top-of-the-range instruments.</li>
<li>CAT IV 600V, CAT III 1000V Safety Rating</li>
<li>Similar to the Fluke 1587 &amp; Fluke 1577</li>
<li>ISO 9000 CALIBRATION CERTIFICATE INCLUDED</li>
</ul>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">
<h4><strong>HT ITALIA NEPTUNE Technical Specifications</strong></h4>
</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>DC voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS, LoZ voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.5V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">32Hz ÷ 1kHz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS current with flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS current with standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Resistance and Continuity test</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0Ω ÷ 1999Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(1.0%reading + 5digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Buzzer test</span></td>
<td class="speccelldata"><span style="font-size: 90%;">R&lt;30Ω</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Voltage / Current harmonics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Harmonic order</span></td>
<td class="speccelldata"><span style="font-size: 90%;">DC, 1st ÷ 25th + THD%</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V / 0.1A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(5.0%rdg + 10digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Phase sequence with 1 terminal</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">100V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Insulation resistance</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test voltages</span></td>
<td class="speccelldata"><span style="font-size: 90%;">50,100,250,500,1000VDC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 999MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 1MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Timer for measurements</span></td>
<td class="speccelldata"><span style="font-size: 90%;">15s, 30s, 1min, 5min, 10min</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Continuity of protective conductors</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test current</span></td>
<td class="speccelldata"><span style="font-size: 90%;">&gt;200mA DC (@ R&lt;5Ω)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.00Ω ÷ 199.9Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Open-circuit voltage</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 &lt; Vo &lt; 12V DC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>General characteristics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Instrument safety</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61010-2-033</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">EMC</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61326-1</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test MΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test LoΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-4</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Phase sequence</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61557-7</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Insulation</span></td>
<td class="speccelldata"><span style="font-size: 90%;">double insulation</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Pollution level</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measurement category</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CAT IV 600V, CAT III 1000V to earth and between inputs</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Mechanical characteristics</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Size (L x W x H)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">175 x 85 x 55mm</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Weight (batteries included)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">420g</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Mechanical protection</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IP40</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Power supply</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Battery type</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4&#215;1.5V batteries type AAA IEC LR03</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Auto power off</span></td>
<td class="speccelldata"><span style="font-size: 90%;">after 15 minutes’ idling</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Display</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Type of display</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 dgt LCD, max 9999 dots, decimal sign, point, backlight and bargraph, indication of polarity</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Updating frequency</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2 times/s</span></td>
</tr>
</tbody>
</table>
<h3>HT ITALIA NEPTUNE  Included Accessories:</h3>
<p>• 4324-2 Pair of Red/Black banana connectors with 2/4mm tip<br />
• YAAMK0001HT0 Pair of Red/Black alligator clips<br />
• YABAT0001HT0 Alkaline battery type AAA IEC LR03 1.5V, 4 pieces<br />
• YABRS0002HT0 Carrying bag<br />
• YAMUM0068HT0 User manual on CD-ROM<br />
• YAMUM0067HT0 Quick user guide<br />
• Calibration certificate ISO9000</p>
<h3>Optional Accessories:</h3>
<p>• F3000U Flexible clamp with full scale 30/300/3000A AC and banana connectors<br />
• HT96U* Standard clamp with full scale 1/100/1000A AC and Hypertac connector<br />
• HT97U* Standard clamp with full scale 10/100/1000A AC and Hypertac connector<br />
• HT98U* Standard clamp with full scale 1000A DC and Hypertac connector<br />
• HT4006 Standard clamp with full scale 40/400A AC/DC and banana connectors<br />
• NOCANBA Adapter for clamp connection with Hypertac connector<br />
• 5004-IECR Red alligator clip<br />
• 5004-IECN Black alligator clip<br />
• C2065 3-wire cable Red, Black and Green with Schuko plug</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/">HT ITALIA NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT ITALIA JUPITER Multi-Function Multimeter</title>
		<link>https://obiat.com.au/product/ht-italia-jupiter-multi-function-multimeter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 15 Oct 2017 05:22:03 +0000</pubDate>
				<guid isPermaLink="false">http://obiat.com.au/?post_type=product&#038;p=4273</guid>

					<description><![CDATA[<h4><a href="http://obiat.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO.png"><img class="alignnone size-full wp-image-952" src="http://obiat.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO.png" alt="HT ITALIA LOGO" width="160" height="100" /></a></h4>
<h4>JUPITER THE MULTI-FUNCTION MULTIMETER FOR ELECTRICAL INSTALLATION SAFETY TESTING</h4>
<p><strong>HT ITALIA </strong><b>revolutionises</b> the portable instrument market by introducing the new <strong>JUPITER</strong>.</p>
<p>The <span style="color: #ff0000;"><strong>first</strong></span> <strong>multimeter</strong> who <strong>incorporates</strong> the <strong>functions available only in standard electrical safety testers </strong>and professional <strong>High-end multimeters.</strong></p>
<ul>
<li>Test tripping time of RCDs type A and AC up to 300mA*.</li>
<li>Tripping current of RCDs type AC up to 30mA.</li>
<li>Non-trip earth ground resistance.</li>
<li>Line-to-Neutral, Line-to-Line and Line-to-Ground impedance (resolution 0.1Ohm) with prospective short-circuit/fault current calculation.</li>
<li>Current up to 3000A by means of clamp-on or flexible external transducer. ›</li>
<li>Dynamic inrush current of motors and loads through the DIRC function allowing time base selection. ›</li>
<li>Leakage current by means of the clamp-on transducer HT96U.</li>
<li>Voltage and current harmonics with THD% calculation and function to the 25th Harmonic (Higher Harmonic Ordering) showing highest harmonic values first.</li>
<li>One-lead phase sequence detection</li>
<li>JUPITER is provided with ISO9000 calibration certificate as standard.</li>
</ul>
<p><iframe src="https://www.youtube.com/embed/mpOH1QRr4lI?rel=0" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h4><a href="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png"><img class="alignnone size-full wp-image-4253" src="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline; color: #ff6600;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Jupiter-Brochure.pdf" rel="noopener">HT Jupiter Brochure</a></span></h4>
<h4><a href="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png"><img class="alignnone size-full wp-image-4253" src="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #ff6600;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Jupiter-Datasheet.pdf" rel="noopener">HT Jupiter Datasheet</a></span></span></h4>
<h4><a href="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png"><img class="alignnone size-full wp-image-4253" src="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #ff6600;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Jupiter-User-Manual.pdf" rel="noopener">HT Jupiter User Manual</a></span></span></h4>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-jupiter-multi-function-multimeter/">HT ITALIA JUPITER Multi-Function Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>As professional multimeter HT ITALIA JUPITER Multi-Function Multimeter provides:</h4>
<p><strong>Autorange</strong> measurements with automatic <strong>AC/DC</strong> detection<br />
<strong>LoZ</strong> low impedance voltage input to eliminate <strong>ghost voltage</strong> readings (caused by the capacitive coupling among active conductors close each other)<br />
One-lead <strong>phase sequence detection</strong></p>
<p>JUPITER is provided with ISO9000 calibration certificate as standard.</p>
<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3.jpg"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-4278" src="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3.jpg" alt="Jupiter Banner 3" width="934" height="343" srcset="https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3.jpg 934w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3-600x220.jpg 600w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3-300x110.jpg 300w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3-768x282.jpg 768w" sizes="(max-width: 934px) 100vw, 934px" /></a></p>
<h3>HT ITALIA JUPITER Multi-Function Multimeter Features:</h3>
<ul>
<li>Autorange measurements with automatic AC/DC detection.</li>
<li>DC, AC TRMS, AC+DC TRMS voltage up to 690V.</li>
<li>Tripping time of RCDs type A and AC up to 300mA*.</li>
<li>Tripping current of RCDs type AC up to 30mA. ›</li>
<li>Non-trip earth ground resistance. ›</li>
<li>Line-to-Neutral, Line-to-Line and Line-to-Ground impedance (resolution 0.1Ohm) with prospective short-circuit/fault current calculation.</li>
<li>Current up to 3000A by means of clamp-on or flexible external transducer.</li>
<li>Dynamic inrush current of motors and loads through the DIRC function allowing time base selection.</li>
<li>Leakage current by means of the clamp-on transducer HT96U.</li>
<li>Voltage and current harmonics with THD% calculation and function to the 25th Harmonic showing highest harmonic values first.</li>
<li>One-lead phase sequence detection.</li>
<li>Low impedance voltage input to eliminate ghost voltage readings.</li>
<li>DC, AC TRMS, AC+DC TRMS current by means of external transducer.</li>
<li>Frequency of voltage and/or current.</li>
<li>Resistance and continuity with buzzer.</li>
<li>MIN/MAX/PEAK/HOLD functions.</li>
<li>6000 count Display</li>
</ul>
<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1.jpg"><img decoding="async" class="alignnone size-full wp-image-4277" src="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1.jpg" alt="Jupiter Banner 1" width="647" height="453" srcset="https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1.jpg 647w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1-600x420.jpg 600w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1-300x210.jpg 300w" sizes="(max-width: 647px) 100vw, 647px" /></a></p>
<h3><strong>HT ITALIA JUPITER Multi-Function Multimeter Functions</strong></h3>
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>TRMS</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>AC/DC voltage</td>
<td class="description">690V / AC+DC</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>LoZ Input</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>AC/DC current</td>
<td class="description">AC+DC with external clamp transducer</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Frequency</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Resistance and continuity test with buzzer</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>RCD tripping time</td>
<td class="description">30mA, 100mA, 300mA A/AC</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>RCD trip current measurement</td>
<td class="description">RCD A/AC 30mA</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Leakage current (with optional accessory HT96U)</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Non-trip earth resistance</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Voltage and current harmonics up to the 25th and THD%</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Electric motor starting current (INRUSH)</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Auto x1/2, x1, x2, x5, 0°, 180°</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Phase sequence</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Out come OK/NOT OK</td>
<td class="description">According with IEC60364-6</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Backlit LCD display</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Measurement category</td>
<td class="description">CAT IV 600V</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Measuring counts</td>
<td class="description">6000</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>MAX/MIN/HOLD</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Bargraph</td>
<td class="description"></td>
</tr>
</tbody>
</table>
<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2.jpg"><img decoding="async" class="alignnone size-full wp-image-4281" src="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2.jpg" alt="Jupiter Banner 2" width="643" height="502" srcset="https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2.jpg 643w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2-600x468.jpg 600w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2-300x234.jpg 300w" sizes="(max-width: 643px) 100vw, 643px" /></a></p>
<div>
<div class="row"  id="row-765979490">

	<div id="col-2083200187" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<strong>HT Instruments JUPITER Standard Accessories:</strong></p>
		</div>
					</div>

	
</div>
</div>
<div><div class="row"  id="row-777459210">
	<div id="col-1725628941" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			</div>
<div></div>
<div>• <strong>C2033AU</strong> Three wire cable Red, Black, Green with Australian plug<br />
• <strong>4324-2</strong> Pair of test tips Red/Black 2/4mm straight banana<br />
•<strong> YABAT0001HT0</strong> Alkaline battery 1.5V, type AAA, IEC LR03, 4 pcs<br />
• <strong>YABRS0002HT0</strong> Carrying bag<br />
• <strong>YAMUM0066HT0</strong> User manual on CD-ROM<br />
• <strong>YAMUM0065HT0</strong> Quick reference guide<br />
• <strong>Calibration certificate ISO9000.</strong>		</div>
					</div>

	

	<div id="col-1897055585" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<figure id="attachment_5765" aria-describedby="caption-attachment-5765" style="width: 300px" class="wp-caption alignnone"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-C2033AU-accessory.jpg"><img decoding="async" class="size-medium wp-image-5765" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-C2033AU-accessory-300x104.jpg" alt="" width="300" height="104" /></a><figcaption id="caption-attachment-5765" class="wp-caption-text">C2033AU Three wire cable Red, Black, Green with Australian plug</figcaption></figure>
		</div>
					</div>

	
</div>
</div>
<div> <div class="row"  id="row-1134986375">
	<div id="col-390204004" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<strong>HT Instruments JUPITER Optional Accessories:</strong>		</div>
					</div>

	</div>
<div class="row"  id="row-435771743">
	<div id="col-624573268" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
• <strong>F3000U</strong> AC flexible clamp with 30/300/3000A full scales<br />
• <strong>HT96U</strong>* AC current clamp with 1/100/1000A full scales<br />
• <strong>HT97U</strong>* AC current clamp with 10/100/1000A AC full scales<br />
• <strong>HT98U</strong>* DC current clamp with 1000A full scale<br />
• <strong>HT4006</strong> AC/DC current clamp with 40/400A full scales<br />
• <strong>NOCANBA</strong> Hypertac-to-banana adapter* Adapter NOCANBA required.		</div>
					</div>

	

	<div id="col-1645179544" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<figure id="attachment_5767" aria-describedby="caption-attachment-5767" style="width: 375px" class="wp-caption alignnone"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Jupiter-Clamps.png"><img decoding="async" class="size-full wp-image-5767" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Jupiter-Clamps.png" alt="" width="375" height="215" /></a><figcaption id="caption-attachment-5767" class="wp-caption-text">F3000U &amp; HT4006 Clamps</figcaption></figure>
		</div>
					</div>

	
</div>
</div>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-jupiter-multi-function-multimeter/">HT ITALIA JUPITER Multi-Function Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</title>
		<link>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/</link>
					<comments>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 12 Jul 2016 08:14:50 +0000</pubDate>
				<guid isPermaLink="false">http://obiat.com.au/?post_type=product&#038;p=3846</guid>

					<description><![CDATA[<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Italia-Aus-small.jpg"><img class="alignnone size-full wp-image-4270" src="http://obiat.com.au/wp-content/uploads/2017/10/HT-Italia-Aus-small.jpg" alt="HT-Italia-Aus-small" width="192" height="100" /></a></p>
<h4><strong>The GSC60 is a Multifunction Professional Electrical Analyzer.</strong></h4>
<h4><strong><span style="color: #ed1c24;">No other instrument can match it's versatility.</span></strong></h4>
<p><span style="color: #ff0000;"><strong>NOTE:</strong></span> <strong>This is the Australian version with the correct wiring colours and C Tick certification.</strong></p>
<h5><strong>The GSC60 Measures:</strong></h5>
<ul>
<li><strong>Power Quality</strong> - 9 types of Electrical Systems (both single &#38; 3 phase)</li>
<li><strong>Installation Testing</strong></li>
<li><strong>Earth Resistance</strong> - 2 or 3 Pole</li>
<li><strong>Soil Resistivity</strong> - 4 pole Wenner method</li>
<li><strong>RCD Testing</strong> - A, AC &#38; B</li>
<li><strong>Insulation Resistance</strong> - up to 1000V</li>
<li><strong>Continuity</strong> - test currents up to 200mA</li>
<li><strong>Advanced Loop Testing</strong></li>
<li><strong>Phase Sequence</strong></li>
<li><strong>Leakage Current</strong></li>
<li><strong>Cat IV Safety Rating</strong></li>
</ul>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline; color: #0000ff;"><strong><a href="http://obiat.com.au/wp-content/uploads/2016/07/GSC60-Brochure.pdf">GSC60 Brochure</a></strong></span></h5>
<h5><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2016/07/GSC60-User-Manual.pdf" rel="noopener noreferrer">GSC60 User Manual</a></span></span></h5>
<p>The post <a href="https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/">HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>The HT INSTRUMENTS GSC60 &#8211; One instrument for all electrical safety tests.</strong></h2>
<p><iframe width="1020" height="574" src="https://www.youtube.com/embed/7LqND-OF0jc?feature=oembed" frameborder="0" allow="accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></p>
<h2><strong><span style="color: #f99b1c;">MEASURES:</span></strong></h2>
<p><strong>›    </strong><strong>Earth</strong> <strong>Resistance</strong> with 2- or 3-pole <strong>volt-ampere method </strong>in TT, TN and IT systems, <strong>non-trip earth loop impedance measurement</strong>, <strong>stackless earth ground resistance measurement  </strong>with T2100 (optional).</p>
<p><strong>›    </strong><strong>Soil</strong> <strong>Resistivity</strong> with <strong>4 pole </strong>Wenner method.</p>
<p><strong>›    </strong><strong>RCD</strong> <strong>Testing</strong> <strong>type</strong> A, AC, B with test current up to 10A.**</p>
<p><strong>›    </strong><strong>Insulation</strong> <strong>Resistance</strong> measurement with test voltage <strong>up</strong> <strong>to</strong> <strong>1000V</strong>.</p>
<p><strong>›    </strong><strong>Continuity </strong>measurement of protective conductors with test current <strong>up to 200mA</strong>.</p>
<p><strong>›    </strong><strong>Advanced </strong><strong>Loop </strong>Testing of MCBs, fuses and cable sizing.</p>
<p><strong>›    </strong>Measurement of <strong>phase sequence (SEQ)</strong>.</p>
<p>›    Measurement and recording of environment parameters and leakage currents through external probes.</p>
<h2><span style="color: #f99b1c;"><strong>HT INSTRUMENTS GSC60 for the Analysis of Power Quality and Energy Consumption.</strong></span></h2>
<p><strong>›    </strong><strong>9 types of electrical systems: </strong>1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.</p>
<p><strong>›    </strong><strong>632</strong> <strong>parameters</strong> <strong>can</strong> <strong>be</strong> <strong>recorded</strong> <strong>for</strong> <strong>over</strong> <strong>two</strong> <strong>months</strong>.</p>
<p><strong>›    </strong><strong>Real</strong> <strong>Time</strong>. Real-time display of all <strong>waveforms</strong>, <strong>harmonics</strong>, <strong>vector</strong> <strong>diagrams</strong> as well as <strong>summary</strong> <strong>function </strong>on phases for a <strong>quick reading </strong>of the most important parameters.</p>
<p><strong>›    </strong><strong>Voltage</strong> <strong>Anomalies</strong>. Detection of voltage anomalies with a resolution of <strong>20ms</strong>.</p>
<p><strong>›    </strong><strong>Energy</strong> <strong>Saving.</strong> <strong>One</strong> <strong>click</strong> <strong>allows</strong> <strong>you</strong> <strong>to</strong> <strong>check</strong> <strong>all</strong> <strong>the</strong> <strong>electrical</strong> <strong>absorption</strong> of all the equipment connected to the main power supply and save on energy costs.</p>
<h2><span style="color: #f99b1c;">Live. Real Time Analysis.</span></h2>
<p>Wi-Fi connection allows you to display wave forms, vector diagrams, harmonics and all electrical parameters for each phase on your tablet/smartphone/PC</p>
<p>GSC60 helps to dispel the myth that recording analysis is complex. App HTanalysis makes it simple and clear. Using ZOOM Functions you can display all the recorded quantities. JUMP Function displays harmonics in any recording step just by clicking on the quantity.</p>
<h2><span style="color: #f99b1c;"><strong>HT INSTRUMENTS GSC60 Functions:</strong></span></h2>
<div class="mm-page mm-slideout">
<div class="container-body center-block">
<div class="pg-opt prodotti">
<div class="container-fluid">
<div class="row">
<div class="col-md-12">
<section class="slice bg-greyprod">
<div class="container">
<div class="tab-content">
<div id="tab-2" class="tab-pane fade active in">
<div class="tab-body prodotti">
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function thin-font">   <span style="color: #000000;"> Touchscreen colour display</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Integrated WiFi connection and compatibility with HTANALYSIS App</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Continuity of protective circuit with 200mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Insulation with voltage 50, 100, 250, 500, 1000VDC</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Time/Current tripping of type B RCDs up to 300mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Line/Loop impedance with high resolution (with optional accessory IMP57)</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Percentage voltage drop on the line</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Measurement and recording of leakage currents and environment parameters</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><strong> Three-phase Power quality and Energy consumption analysis:</strong><br />
♦  <span style="color: #282828;"> 9 types of electrical systems:</span><br />
<span style="color: #282828;"> ♦   1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     632 parameters can be recorded for over two months</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage Anomalies (dips and peaks) with a resolution of 20ms @ 50Hz</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Active, Reactive, Apparent Power</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Active, Reactive, Apparent Energy</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Cosphi, Power Factor</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/Recording of Voltage and Current Harmonics up to 49th with THD%</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage/current vector diagram</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage/current waveforms</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Tables or histograms of Harmonics and THD%</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Summary table of main electric parameters</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Help on line on the display</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Protection category &#8211; CAT IV</span></td>
</tr>
</tbody>
</table>
</div>
<div></div>
<div class="list-check"><strong style="font-size: 20.16px;"><span style="color: #f99b1c;">GSC60 Standard Accessories:</span></strong></div>
</div>
</div>
</div>
<p>• HTFLEX33E AC flexible clamp for currents up to 3000A, diameter 174mm, 4 pieces<br />
• C2033X 3-banana to Shuko plug cable<br />
• UNIVERSALKITG3 Set of 4 cables, 4 alligator clips and 3 test leads<br />
• KITTERRNE Soft carrying bag containing 4 cables and 4 earth rods<br />
• PR400 Remote switch probe<br />
• PT400 Stylus<br />
• BORSA2051 Soft carrying bag<br />
• TOPVIEW2006 PC software and optical-to-USB connection cable C2006<br />
• YABAT0003000 Rechargeable NiMH battery 1.2V, AA, 6 pcs<br />
• A0060 Power Supplier\Battery Charger 100/230Vac &#8211; 15Vdc, 10W CAT IV<br />
• C7051 Power cable Shuko-Europlug ground-less 1.50mt<br />
• SP-5100 Hands Free kit<br />
• Quick user’s guide<br />
• User’s manual on CD-ROM<br />
• Calibration certificate ISO9000</p>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/">HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</title>
		<link>https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 09 May 2016 10:02:30 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=3342</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<div class="productDetails">
<div class="itemDesc">
<p id="pShortDesc"><strong>HT Italia HT9 Two pole voltage tester with Lamp test</strong></p>
</div>
</div>
<p class="block">In addition to DC/AC voltage measurement and continuity testing the HT Italia HT9 also offers gas-filled lamp tests and phase sequence/conformity detection features.</p>
<h4>HT Italia HT9 Features:</h4>
<ul>
<li>DC/AC voltage up to 690V</li>
<li>AC voltage detector with 1 wire method</li>
<li>Neon and fluorescent lamp test</li>
<li>Sodium/mercury vapor lamp test</li>
<li>Halogen lamp test</li>
<li>Non-electronic ballast test</li>
<li>Continuity test</li>
<li>Phase sequence test</li>
<li>Diode test</li>
<li>LED and acoustic indications</li>
<li>Built-in torch</li>
<li>LCD display</li>
<li>Safety: IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61243-3:2010</li>
<li>Measurement category: CAT III 690V, CAT IV 600V</li>
</ul>
<h5><strong>Authorised Australian Distributor</strong></h5>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" /><strong>   <a href="http://obiat.com.au/wp-content/uploads/2016/05/HT-9-8-6.pdf" target="_blank">HT9-8-6 Brochure</a></strong></p>
<p><strong><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a href="http://obiat.com.au/wp-content/uploads/2016/05/HT9-8-6-User-Manual.pdf" target="_blank">HT9-8-6 User Manual</a></strong></p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/">HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>To overcome difficult pinpointing of the right cable within a frame on a switchboard under poor light conditions, a built-in white LED flashlight makes testing possible and easy even in dark environments. The slim and ergonomic design of HT Italia HT9 is highly appreciated by contracting electricians, field professionals, troubleshooters as well as any kind of user.</p>
<p>Designed according to the requirements of field professionals, HT Italia HT9 is must-have troubleshooting tool.</p>
<p><b>Two pole voltage meter with Lamp Test. With built-in gas-filled lamp tester and non-contact phase sequence/conformity tester</b></p>
<p><img decoding="async" class="alignnone wp-image-3344" src="http://obiat.com.au/wp-content/uploads/2016/05/HT9_small3.jpg" alt="HT9_small3" width="273" height="220" /></p>
<p>Digital two pole voltage tester HT Italia HT9 provides daily use features. In addition to DC/AC voltage measurement and continuity test, HT9 also offers gas-filled lamp test and phase sequence/conformity detection features. To overcome difficult pinpointing of the right cable within a frame on a switchboard under poor light conditions, a built-in white LED flashlight makes testing possible and easy even in dark environments. The slim and ergonomic design of HT9 is highly appreciated by contracting electricians, field professionals, troubleshooters as well as any vkind of user. Designed according to the requirements of field professionals, HT9 is must-have troubleshooting tool.</p>
<table class="spectable" style="height: 226px;" border="0" width="560" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="speccellcategory" colspan="3" align="center"><strong>Figure 2 &#8211; HT Italia HT9 LED and Display Description</strong></td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>1.</strong></td>
<td class="speccelldata">Voltage indication leds</td>
<td class="speccelldata" rowspan="9" align="center"> <img decoding="async" class="alignnone size-full wp-image-3343" src="http://obiat.com.au/wp-content/uploads/2016/05/HT9-LED-Display.jpg" alt="HT9 LED Display" width="238" height="290" /></td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>2.</strong></td>
<td class="speccelldata">Buzzer hole for acoustic signal</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>3.</strong></td>
<td class="speccelldata">Indication led Lamp test</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>4.</strong></td>
<td class="speccelldata">Indication led Phase sequence</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>5.</strong></td>
<td class="speccelldata">Indication led Phase detection / Dangerous voltage</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>6.</strong></td>
<td class="speccelldata">Indication led Continuity test</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>7.</strong></td>
<td class="speccelldata">Indication led 12V and positive or negative polarity</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>8.</strong></td>
<td class="speccelldata">LCD display with voltage, polarity and flat battery indic</td>
</tr>
</tbody>
</table>
<table border="0" width="95%" cellspacing="5" cellpadding="5" align="center">
<tbody>
<tr>
<td valign="top">The HT Italia HT9 can also be used to check reactors, starters,<br />
capacitors and resistors, further to the following kinds of lamps:</p>
<ul>
<li>Fluorescent lamps</li>
<li>Low-pressure sodium lamps</li>
<li>High-pressure sodium lamps</li>
<li>Neon tubes</li>
<li>Mercury-vapour lamps and halogen lamps</li>
</ul>
</td>
<td valign="top"><b>Standards</b></p>
<ul>
<li>EMC 2004/108/CE Directive</li>
<li>CE MARK</li>
<li>IEC/EN 61010-1</li>
<li>IEC/EN61010-2-030</li>
<li>IEC/EN61243-3:2010</li>
<li>LVD 2006/95/CE Directive</li>
</ul>
</td>
</tr>
</tbody>
</table>
<h3>HT Italia HT9 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellheader" colspan="2">TECHNICAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccelldata" colspan="2"><small>Accuracy indicated as: ±[%rdg + (num. dgt * resolution)] at 23°C ± 5°C, &lt;70%HR</small></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">AC/DC VOLTAGE MEASUREMENT</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range [V]</td>
<td class="speccelldata">12.0 &#8211; 299.9<br />
300 &#8211; 690</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Resolution [V]</td>
<td class="speccelldata">0.1<br />
1</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">16 &#8211; 400</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Accuracy</td>
<td class="speccelldata">+/-(3%rdg + 5dgt)</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Overload protection</td>
<td class="speccelldata">690VDC/AC</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">AC VOLTAGE WITH 1 WIRE</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range [V]</td>
<td class="speccelldata">100 &#8211; 690</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">50 &#8211; 60</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement method</td>
<td class="speccelldata">1-wire with contact on metal live parts</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Overload protection</td>
<td class="speccelldata">690VAC</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">PHASE SEQUENCE INDICATION</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Voltage range [V]</td>
<td class="speccelldata">120 &#8211; 400 (Phase – Earth)</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">50 &#8211; 60</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement method</td>
<td class="speccelldata">2-wires with contact on metal live parts</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">LAMP TEST</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Voltage with new battery</td>
<td class="speccelldata">Approx 3kV / 240kHz</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Field intensity (200-280kHz)</td>
<td class="speccelldata">Approx 100µV/m</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Indications</td>
<td class="speccelldata">LED blinking</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">CONTINUITY TEST</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range</td>
<td class="speccelldata">0 &#8211; 500KΩ + 50%</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Test current</td>
<td class="speccelldata">&lt;7µA</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Indications</td>
<td class="speccelldata">LED + acoustic signal</td>
</tr>
<tr>
<td class="speccellheader" colspan="2">GENERAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Mechanical specifications</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Dimensions (L x W x H)</td>
<td class="speccelldata">255 x 60 x 35mm</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Weight (included batteries)</td>
<td class="speccelldata">170g</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Encapsulation</td>
<td class="speccelldata">IP64</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Display</td>
<td class="speccelldata">LED, LCD</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Power supply</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Internal supply</td>
<td class="speccelldata">2&#215;1.5V alkaline batteries type AAA, IEC LR03</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Reference guidelines</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Safety</td>
<td class="speccelldata">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61243-3:2010</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement category</td>
<td class="speccelldata">CAT III 690V; CAT IV 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Max height of use</td>
<td class="speccelldata">2000m</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Environmental conditions</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Reference temperature</td>
<td class="speccelldata">23°C ± 5°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working temperature</td>
<td class="speccelldata">-15 to 55°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working humidity</td>
<td class="speccelldata">&lt;85%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Storage temperature</td>
<td class="speccelldata">-20 to 70°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Storage humidity</td>
<td class="speccelldata">&lt;85%HR</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/">HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</title>
		<link>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:52:46 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2843</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<p>The HT Italia XL423 is a single phase voltage date logger capable of performing measurements and recordings of TRMS AC voltage up to 600V. It has a sophisticated memory algorithm which allows it to record for up to 1 year.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/">HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL423 can perform measurements and recording of True-Rms AC voltage up to 600 volts in a single phase system. Applications include evaluation of network voltages and unbalanced loads etc. The instrument is contained in a safety IP65 case with built-in test leads and safety alligator clips for voltage measurements. The system can record for a very long time, up to around a year. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<table id="table77" border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="42%">
<h4><span style="font-size: large;">HT Italia XL423 Functions:</span></h4>
<ul>
<li>True-rms AC voltage measurement up to 600V.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<p>&nbsp;</p>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Set of two alligator clips, KITXL423C.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
</td>
</tr>
<tr>
<td colspan="2" valign="top" width="79%">
<div align="center">
<table id="table80" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">0 Volts to 600 Volts</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">0.1 Volt</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(1.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><i>Note: meter consider null readings &lt; 2 volts</i></td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
5 days/1 sec; 34 days/6 sec; 170 days/30 sec; 364 days/1 min;<br />
1820 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">120mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Test Lead Length</td>
<td bgcolor="#C0C0C0">2.6 meters</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/">HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia HT70 Voltage Stick with Phase Sequence Tester</title>
		<link>https://obiat.com.au/product/ht-italia-ht70-voltage-stick-phase-sequence-tester/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht70-voltage-stick-phase-sequence-tester/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 17 Mar 2016 03:13:30 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1740</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p><span style="color: #000000;"><strong>HT Italia HT70 is a practical innovative pen device capable of carrying out, further to the phase detection function, a phase sequence and phase concordance test with LED indications and buzzer, also on the insulating sheath of the conductors.</strong></span></p>
<p>The result of the test is indicated by the<br />
<span style="color: #ff0000;"><strong>R</strong><strong><span style="color: #ff0000;">e</span>d LED</strong> </span><strong>(incorrect phase sequence)</strong> or the<br />
<strong><span style="color: #339966;">Green LED</span> (correct phase sequence) </strong>turning on, by simply moving the sensor first on the L1 and then on the L2 phase.</p>
<h5><strong>HT Italia HT70 Features:</strong></h5>
<ul>
<li>AC voltage range detection: 100 - 1000V AC to ground</li>
<li>Frequency range: 50/60Hz</li>
<li>Phase sequence indication with 1-wire</li>
<li>Conformity test with 1-wire</li>
<li>Safety: IEC/EN61010-1</li>
<li>Category of measurement: CAT IV-1000V</li>
<li>Insulation: double insulation</li>
<li>Pollution degree: 2</li>
<li><strong><span style="color: #ff0000;">Red LED</span></strong> indication =&#62; incorrect phase sequence indication</li>
<li><strong><span style="color: #339966;">Green LED</span></strong> indication =&#62; correct phase sequence indication</li>
<li>Buzzer indication</li>
<li>Power supply: 2x1.5V batteries alkaline type AAA</li>
<li>Working temperature: -10°C  50°C</li>
<li>Working humidity: &#60;75%RH(-10°C to 40°C), &#60;45%RH (40°C to 50°C)</li>
<li>Dimensions (LxWxH): 160 x 26 x 20mm</li>
<li>Weight (included batteries): 48g</li>
</ul>
<p><img class="alignnone size-full wp-image-1739" src="http://obiat.com.au/wp-content/uploads/2016/03/Warranty-4.jpg" alt="Warranty 4" width="149" height="41" /></p>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline;"><strong><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://obiat.com.au/wp-content/uploads/2016/03/HT70-Data-Sheet.pdf" target="_blank">HT70 Data Sheet</a></span></strong></span></h5>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline;"><strong><span style="color: #0000ff;"><a style="color: #0000ff; text-decoration: underline;" href="http://obiat.com.au/wp-content/uploads/2016/03/HT70-User-Manual.pdf" target="_blank">HT70 User Manual</a></span></strong></span></h5>
<p><a href="https://www.youtube.com/watch?v=h_WqLCLcjcE" target="_blank"><img class="alignnone wp-image-1742" src="http://obiat.com.au/wp-content/uploads/2016/03/ht-70.jpg" alt="ht-70" width="117" height="66" /> <img class="alignnone wp-image-1648" src="http://obiat.com.au/wp-content/uploads/2016/02/Play.jpg" alt="Play" width="53" height="39" /></a></p>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht70-voltage-stick-phase-sequence-tester/">HT Italia HT70 Voltage Stick with Phase Sequence Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia HT70 pen voltage detector permits both to quickly verify the presence of AC voltage on any type of electrical installation (sockets, cables, fuses, switchboards, etc.) with and without direct contact and also to perform phase sequence indication and conformity test on generic three phase plants by using red and green fixed and blinking LED indications. HT Italia HT70 is designed according to IEC/EN61010-1 safety standard in CAT IV 1000V.</p>
<p>&nbsp;</p>
<p><img decoding="async" class="alignnone size-full wp-image-3624" src="http://obiat.com.au/wp-content/uploads/2016/03/HT70-1.jpg" alt="HT70-1" width="561" height="301" srcset="https://obiat.com.au/wp-content/uploads/2016/03/HT70-1.jpg 561w, https://obiat.com.au/wp-content/uploads/2016/03/HT70-1-300x161.jpg 300w" sizes="(max-width: 561px) 100vw, 561px" /></p>
<h5><strong>HT ITALIA HT70 Description:</strong></h5>
<ol>
<li>Voltage Detection Sensor</li>
<li>Reference Mark CAT-IV Measurement</li>
<li>Hand Safety Protection</li>
<li>“ON” Switch and white LED indication</li>
<li>Pocket “Pen” Clip</li>
<li>RED/GREEN Indicator</li>
<li>Pressure Point to remove Battery Cover</li>
<li>Battery Cover Slide.</li>
</ol>
<h5><strong>Voltage detection test:</strong></h5>
<p>1. Turn on the meter by pressing ON/OFF key for at least 1s. Waiting for the standby mode when the green LED is blinking</p>
<p>2. Position the sensor close to or in contact with the point under test for a time &lt;5s, then verify that the red LED is on and buzzer sounds continuously as evidence of voltage detection. Do not perform test with the operator’s hand beyond the hand safety protection and position not insulated wires beyond the CAT IV reference mark (see part 2 of the picture above)</p>
<p>3. Press ON/OFF key for at least 3s to turn off the meter</p>
<h3>HT Italia HT70 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">ELECTRICAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">AC voltage range detection</td>
<td class="speccelldata">100 &#8211; 1000V AC to ground</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range</td>
<td class="speccelldata">50/60Hz</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Safety</td>
<td class="speccelldata">IEC/EN61010-1</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Category of measurement</td>
<td class="speccelldata">CAT IV 1000V</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">GENERAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Power supply</td>
<td class="speccelldata">2&#215;1.5V batteries alkaline type AAA NEDA24A LR03</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working temperature</td>
<td class="speccelldata">-10°C to 50°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working humidity</td>
<td class="speccelldata">&lt;75%HR (-10°C to 40°C)<br />
&lt;45%HR (40°C to 50°C)</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Dimensions (L x W x H)</td>
<td class="speccelldata">160x26x20mm</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Weight (included batteries)</td>
<td class="speccelldata">48g</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht70-voltage-stick-phase-sequence-tester/">HT Italia HT70 Voltage Stick with Phase Sequence Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht70-voltage-stick-phase-sequence-tester/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT ITALIA HT20S Phase Detector with Torch</title>
		<link>https://obiat.com.au/product/ht-italia-ht20-phase-detector-integrated-torch/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht20-phase-detector-integrated-torch/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 17 Mar 2016 02:28:42 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1732</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<h5>Pen phase detector HT ITALIA HT20S allows <strong>very quickly checking</strong> for the <strong>presence of AC voltage on any kind of electric installation with and without direct contact</strong>.</h5>
<p>A <span style="color: #ff0000;"><strong>Red LED</strong></span> turns on and a <strong>buzzer sounding reveal the presence of voltage</strong>.</p>
<h5><strong>Features:</strong></h5>
<ul>
<li>AC voltage range detection: 100 - 1000V AC to ground</li>
<li>Frequency range: 50/60H</li>
<li>Safety: IEC/EN61010-1</li>
<li>Category of measurement: <strong>CAT IV-1000V</strong></li>
<li>Insulation: double insulation</li>
<li>Pollution degree: 2</li>
<li>Red LED indication of detected voltage</li>
<li>Buzzer indication</li>
<li>White LED torch with ON/OFF key</li>
<li>Power supply: 2x1.5V batteries alkaline type AAA</li>
<li>Working temperature: -10°C to 50°C</li>
<li>Working humidity: &#60;75%RH (-10°C to 40°C),&#60;45%RH (40°C to 50°C)</li>
<li>Size (L-W-H): 160 x 26 x 20mm</li>
<li>Weight (included batteries): 48g</li>
</ul>
<p><img class="alignnone size-full wp-image-1739" src="http://obiat.com.au/wp-content/uploads/2016/03/Warranty-4.jpg" alt="Warranty 4" width="149" height="41" /></p>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />   <strong><span style="color: #0000ff;"> <span style="text-decoration: underline;"><a style="color: #0000ff; text-decoration: underline;" href="http://obiat.com.au/wp-content/uploads/2016/03/HT20S-manual.pdf" target="_blank">HT20S User Manual</a></span></span></strong></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht20-phase-detector-integrated-torch/">HT ITALIA HT20S Phase Detector with Torch</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HT ITALIA HT20S meter can perform AC voltage detection with visible LED red and acoustic buzzer indications. A white LED is can be also activated.</p>
<h5><img decoding="async" class="alignnone size-full wp-image-3622" src="http://obiat.com.au/wp-content/uploads/2016/03/HT20s-1.jpg" alt="HT20s-1" width="341" height="215" srcset="https://obiat.com.au/wp-content/uploads/2016/03/HT20s-1.jpg 341w, https://obiat.com.au/wp-content/uploads/2016/03/HT20s-1-300x189.jpg 300w" sizes="(max-width: 341px) 100vw, 341px" /></h5>
<h5><strong>HT ITALIA HT20S Description:</strong></h5>
<ol>
<li>Voltage Detection Sensor</li>
<li>Reference Mark CAT-IV Measurement</li>
<li>Hand Safety Protection</li>
<li>&#8220;ON&#8221; Switch and white LED indication</li>
<li>Pocket &#8220;Pen&#8221; Clip</li>
<li>White LED Torch</li>
<li>Pressure Point to remove Battery Cover</li>
<li>Battery Cover Slide.</li>
</ol>
<h5>HT ITALIA HT20S Operating Instructions:</h5>
<p>1. Switch on the instrument by pressing key<br />
2. Perform an initial test with meter on an energized circuit. Replace internal batteries if the red LED do not turn on and/or the buzzer do not sound<br />
3. Position the sensor close to or in contact with the point under test then verify that the red LED is on and buzzer sounds continuously as evidence of voltage detection. <strong>Do not perform test with the hand beyond the hand safety protection and do not allow insulated wires beyond the CAT IV reference mark (see part 2 of above picture)</strong><br />
4. If needed press key to turn on the white torch<br />
5. The instrument switch off automatically after 5 minutes of idleness</p>
<h5>HT ITALIA HT20S Technical specifications:</h5>
<ul>
<li>Voltage reference range: 100-1000V AC to ground</li>
<li>Frequency reference range: 50/60Hz</li>
<li>Meter indications: visible LED and acoustic buzzer</li>
<li>Safety: IEC/EN61010-1</li>
<li>Category of measurement: CAT IV 1000V</li>
<li>Pollution degree: 2</li>
<li>Batteries: 2 x 1.5V alkaline type AAA IEC LR03</li>
<li>Working temperature: -10°C to <span style="line-height: 1.5;">50°C</span></li>
<li><span style="line-height: 1.5;">Working humidity: -10 to 40°C;&lt;75%HR; 40-50°C &lt;45%HR </span></li>
<li><span style="line-height: 1.5;">Dimensions (L-W-H): 160 x 26 x 20mm</span></li>
<li><span style="line-height: 1.5;">Weight (included batteries): 48g</span></li>
</ul>