<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Insulation / Continuity Testers Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/ht-italia/insulation-continuity-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/ht-italia/insulation-continuity-testers/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Thu, 05 Feb 2026 21:41:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Insulation / Continuity Testers Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/ht-italia/insulation-continuity-testers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HT ITALIA NEPTUNE Multimeter/Insulation Tester</title>
		<link>https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 19 Jun 2019 04:41:26 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=36329</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg"><img class="alignnone size-full wp-image-3842" src="https://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="" width="166" height="91" /></a></p>
<h4>HT ITALIA NEPTUNE Features:</h4>
<ul>
<li><span style="font-size: 90%;">Autorange function &#38; automatic detection of AC, DC for all measurements.</span></li>
<li><span style="font-size: 90%;">Insulation test voltages of 50,100,250,500,1000VDC</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS voltage up to 1000V.</span></li>
<li><span style="font-size: 90%;">Low-impedance LoZ input to eliminate “stray voltages” from the measurement</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS current by means of an optional external current clamp</span></li>
<li><span style="font-size: 90%;">Measurement of voltage or current frequency.</span></li>
<li><span style="font-size: 90%;">Resistance and continuity with buzzer.</span></li>
<li><span style="font-size: 90%;">MAX/MIN/PEAK/HOLD functions.</span></li>
<li><span style="font-size: 90%;"> CAT IV 600V, CAT III 1000V Safety Rating</span></li>
<li><span style="font-size: 90%;">ISO 9000 Calibration Certificate included</span></li>
<li><span style="font-size: 90%;">Similar to the Fluke 1587 &#38; Fluke 1577</span></li>
</ul>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>     <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-Datasheet.pdf" rel="noopener noreferrer">NEPTUNE Datasheet</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-Brochure.pdf" rel="noopener noreferrer">NEPTUNE Brochure</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-User-Manual.pdf" rel="noopener noreferrer">NEPTUNE User Manual</a></span></h3>
<p>The post <a href="https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/">HT ITALIA NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT ITALIA NEPTUNE Multimeter/Insulation Tester is a mix of technology that includes an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), an Harmonics analyzer and a True  RMS multimeter.</p>
<h4>HT ITALIA NEPTUNE Key Features:</h4>
<ul>
<li>it can quickly measure insulation up to 1000V, just like top-of-the-range testers.</li>
<li>50,100,250,500,1000VDC Insulation test voltages.</li>
<li>it measures continuity of protective conductors with 200mA to solve the most common problems related to masses.</li>
<li>measure Inrush currents, Harmonics and THD%, just like top-of-the-range power quality analyzers.</li>
<li>with a wide range of external clamp transducers it can measure AC TRMS, DC, AC+DC current and Inrush current, starting from 1mA up to 3000A.</li>
<li>compare each measurement with the limits prescribed by the Guidelines and I provide a clear result OK or NOT OK</li>
<li>it&#8217;s a multimeter with functions only available if using top-of-the-range instruments.</li>
<li>CAT IV 600V, CAT III 1000V Safety Rating</li>
<li>Similar to the Fluke 1587 &amp; Fluke 1577</li>
<li>ISO 9000 CALIBRATION CERTIFICATE INCLUDED</li>
</ul>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">
<h4><strong>HT ITALIA NEPTUNE Technical Specifications</strong></h4>
</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>DC voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS, LoZ voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.5V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">32Hz ÷ 1kHz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS current with flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS current with standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Resistance and Continuity test</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0Ω ÷ 1999Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(1.0%reading + 5digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Buzzer test</span></td>
<td class="speccelldata"><span style="font-size: 90%;">R&lt;30Ω</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Voltage / Current harmonics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Harmonic order</span></td>
<td class="speccelldata"><span style="font-size: 90%;">DC, 1st ÷ 25th + THD%</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V / 0.1A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(5.0%rdg + 10digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Phase sequence with 1 terminal</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">100V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Insulation resistance</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test voltages</span></td>
<td class="speccelldata"><span style="font-size: 90%;">50,100,250,500,1000VDC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 999MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 1MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Timer for measurements</span></td>
<td class="speccelldata"><span style="font-size: 90%;">15s, 30s, 1min, 5min, 10min</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Continuity of protective conductors</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test current</span></td>
<td class="speccelldata"><span style="font-size: 90%;">&gt;200mA DC (@ R&lt;5Ω)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.00Ω ÷ 199.9Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Open-circuit voltage</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 &lt; Vo &lt; 12V DC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>General characteristics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Instrument safety</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61010-2-033</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">EMC</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61326-1</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test MΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test LoΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-4</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Phase sequence</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61557-7</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Insulation</span></td>
<td class="speccelldata"><span style="font-size: 90%;">double insulation</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Pollution level</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measurement category</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CAT IV 600V, CAT III 1000V to earth and between inputs</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Mechanical characteristics</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Size (L x W x H)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">175 x 85 x 55mm</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Weight (batteries included)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">420g</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Mechanical protection</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IP40</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Power supply</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Battery type</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4&#215;1.5V batteries type AAA IEC LR03</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Auto power off</span></td>
<td class="speccelldata"><span style="font-size: 90%;">after 15 minutes’ idling</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Display</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Type of display</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 dgt LCD, max 9999 dots, decimal sign, point, backlight and bargraph, indication of polarity</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Updating frequency</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2 times/s</span></td>
</tr>
</tbody>
</table>
<h3>HT ITALIA NEPTUNE  Included Accessories:</h3>
<p>• 4324-2 Pair of Red/Black banana connectors with 2/4mm tip<br />
• YAAMK0001HT0 Pair of Red/Black alligator clips<br />
• YABAT0001HT0 Alkaline battery type AAA IEC LR03 1.5V, 4 pieces<br />
• YABRS0002HT0 Carrying bag<br />
• YAMUM0068HT0 User manual on CD-ROM<br />
• YAMUM0067HT0 Quick user guide<br />
• Calibration certificate ISO9000</p>
<h3>Optional Accessories:</h3>
<p>• F3000U Flexible clamp with full scale 30/300/3000A AC and banana connectors<br />
• HT96U* Standard clamp with full scale 1/100/1000A AC and Hypertac connector<br />
• HT97U* Standard clamp with full scale 10/100/1000A AC and Hypertac connector<br />
• HT98U* Standard clamp with full scale 1000A DC and Hypertac connector<br />
• HT4006 Standard clamp with full scale 40/400A AC/DC and banana connectors<br />
• NOCANBA Adapter for clamp connection with Hypertac connector<br />
• 5004-IECR Red alligator clip<br />
• 5004-IECN Black alligator clip<br />
• C2065 3-wire cable Red, Black and Green with Schuko plug</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/">HT ITALIA NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</title>
		<link>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/</link>
					<comments>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 12 Jul 2016 08:14:50 +0000</pubDate>
				<guid isPermaLink="false">http://obiat.com.au/?post_type=product&#038;p=3846</guid>

					<description><![CDATA[<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Italia-Aus-small.jpg"><img class="alignnone size-full wp-image-4270" src="http://obiat.com.au/wp-content/uploads/2017/10/HT-Italia-Aus-small.jpg" alt="HT-Italia-Aus-small" width="192" height="100" /></a></p>
<h4><strong>The GSC60 is a Multifunction Professional Electrical Analyzer.</strong></h4>
<h4><strong><span style="color: #ed1c24;">No other instrument can match it's versatility.</span></strong></h4>
<p><span style="color: #ff0000;"><strong>NOTE:</strong></span> <strong>This is the Australian version with the correct wiring colours and C Tick certification.</strong></p>
<h5><strong>The GSC60 Measures:</strong></h5>
<ul>
<li><strong>Power Quality</strong> - 9 types of Electrical Systems (both single &#38; 3 phase)</li>
<li><strong>Installation Testing</strong></li>
<li><strong>Earth Resistance</strong> - 2 or 3 Pole</li>
<li><strong>Soil Resistivity</strong> - 4 pole Wenner method</li>
<li><strong>RCD Testing</strong> - A, AC &#38; B</li>
<li><strong>Insulation Resistance</strong> - up to 1000V</li>
<li><strong>Continuity</strong> - test currents up to 200mA</li>
<li><strong>Advanced Loop Testing</strong></li>
<li><strong>Phase Sequence</strong></li>
<li><strong>Leakage Current</strong></li>
<li><strong>Cat IV Safety Rating</strong></li>
</ul>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline; color: #0000ff;"><strong><a href="http://obiat.com.au/wp-content/uploads/2016/07/GSC60-Brochure.pdf">GSC60 Brochure</a></strong></span></h5>
<h5><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2016/07/GSC60-User-Manual.pdf" rel="noopener noreferrer">GSC60 User Manual</a></span></span></h5>
<p>The post <a href="https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/">HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>The HT INSTRUMENTS GSC60 &#8211; One instrument for all electrical safety tests.</strong></h2>
<p><iframe width="1020" height="574" src="https://www.youtube.com/embed/7LqND-OF0jc?feature=oembed" frameborder="0" allow="accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></p>
<h2><strong><span style="color: #f99b1c;">MEASURES:</span></strong></h2>
<p><strong>›    </strong><strong>Earth</strong> <strong>Resistance</strong> with 2- or 3-pole <strong>volt-ampere method </strong>in TT, TN and IT systems, <strong>non-trip earth loop impedance measurement</strong>, <strong>stackless earth ground resistance measurement  </strong>with T2100 (optional).</p>
<p><strong>›    </strong><strong>Soil</strong> <strong>Resistivity</strong> with <strong>4 pole </strong>Wenner method.</p>
<p><strong>›    </strong><strong>RCD</strong> <strong>Testing</strong> <strong>type</strong> A, AC, B with test current up to 10A.**</p>
<p><strong>›    </strong><strong>Insulation</strong> <strong>Resistance</strong> measurement with test voltage <strong>up</strong> <strong>to</strong> <strong>1000V</strong>.</p>
<p><strong>›    </strong><strong>Continuity </strong>measurement of protective conductors with test current <strong>up to 200mA</strong>.</p>
<p><strong>›    </strong><strong>Advanced </strong><strong>Loop </strong>Testing of MCBs, fuses and cable sizing.</p>
<p><strong>›    </strong>Measurement of <strong>phase sequence (SEQ)</strong>.</p>
<p>›    Measurement and recording of environment parameters and leakage currents through external probes.</p>
<h2><span style="color: #f99b1c;"><strong>HT INSTRUMENTS GSC60 for the Analysis of Power Quality and Energy Consumption.</strong></span></h2>
<p><strong>›    </strong><strong>9 types of electrical systems: </strong>1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.</p>
<p><strong>›    </strong><strong>632</strong> <strong>parameters</strong> <strong>can</strong> <strong>be</strong> <strong>recorded</strong> <strong>for</strong> <strong>over</strong> <strong>two</strong> <strong>months</strong>.</p>
<p><strong>›    </strong><strong>Real</strong> <strong>Time</strong>. Real-time display of all <strong>waveforms</strong>, <strong>harmonics</strong>, <strong>vector</strong> <strong>diagrams</strong> as well as <strong>summary</strong> <strong>function </strong>on phases for a <strong>quick reading </strong>of the most important parameters.</p>
<p><strong>›    </strong><strong>Voltage</strong> <strong>Anomalies</strong>. Detection of voltage anomalies with a resolution of <strong>20ms</strong>.</p>
<p><strong>›    </strong><strong>Energy</strong> <strong>Saving.</strong> <strong>One</strong> <strong>click</strong> <strong>allows</strong> <strong>you</strong> <strong>to</strong> <strong>check</strong> <strong>all</strong> <strong>the</strong> <strong>electrical</strong> <strong>absorption</strong> of all the equipment connected to the main power supply and save on energy costs.</p>
<h2><span style="color: #f99b1c;">Live. Real Time Analysis.</span></h2>
<p>Wi-Fi connection allows you to display wave forms, vector diagrams, harmonics and all electrical parameters for each phase on your tablet/smartphone/PC</p>
<p>GSC60 helps to dispel the myth that recording analysis is complex. App HTanalysis makes it simple and clear. Using ZOOM Functions you can display all the recorded quantities. JUMP Function displays harmonics in any recording step just by clicking on the quantity.</p>
<h2><span style="color: #f99b1c;"><strong>HT INSTRUMENTS GSC60 Functions:</strong></span></h2>
<div class="mm-page mm-slideout">
<div class="container-body center-block">
<div class="pg-opt prodotti">
<div class="container-fluid">
<div class="row">
<div class="col-md-12">
<section class="slice bg-greyprod">
<div class="container">
<div class="tab-content">
<div id="tab-2" class="tab-pane fade active in">
<div class="tab-body prodotti">
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function thin-font">   <span style="color: #000000;"> Touchscreen colour display</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Integrated WiFi connection and compatibility with HTANALYSIS App</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Continuity of protective circuit with 200mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Insulation with voltage 50, 100, 250, 500, 1000VDC</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Time/Current tripping of type B RCDs up to 300mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Line/Loop impedance with high resolution (with optional accessory IMP57)</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Percentage voltage drop on the line</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Measurement and recording of leakage currents and environment parameters</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><strong> Three-phase Power quality and Energy consumption analysis:</strong><br />
♦  <span style="color: #282828;"> 9 types of electrical systems:</span><br />
<span style="color: #282828;"> ♦   1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     632 parameters can be recorded for over two months</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage Anomalies (dips and peaks) with a resolution of 20ms @ 50Hz</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Active, Reactive, Apparent Power</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Active, Reactive, Apparent Energy</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Cosphi, Power Factor</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/Recording of Voltage and Current Harmonics up to 49th with THD%</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage/current vector diagram</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage/current waveforms</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Tables or histograms of Harmonics and THD%</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Summary table of main electric parameters</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Help on line on the display</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Protection category &#8211; CAT IV</span></td>
</tr>
</tbody>
</table>
</div>
<div></div>
<div class="list-check"><strong style="font-size: 20.16px;"><span style="color: #f99b1c;">GSC60 Standard Accessories:</span></strong></div>
</div>
</div>
</div>
<p>• HTFLEX33E AC flexible clamp for currents up to 3000A, diameter 174mm, 4 pieces<br />
• C2033X 3-banana to Shuko plug cable<br />
• UNIVERSALKITG3 Set of 4 cables, 4 alligator clips and 3 test leads<br />
• KITTERRNE Soft carrying bag containing 4 cables and 4 earth rods<br />
• PR400 Remote switch probe<br />
• PT400 Stylus<br />
• BORSA2051 Soft carrying bag<br />
• TOPVIEW2006 PC software and optical-to-USB connection cable C2006<br />
• YABAT0003000 Rechargeable NiMH battery 1.2V, AA, 6 pcs<br />
• A0060 Power Supplier\Battery Charger 100/230Vac &#8211; 15Vdc, 10W CAT IV<br />
• C7051 Power cable Shuko-Europlug ground-less 1.50mt<br />
• SP-5100 Hands Free kit<br />
• Quick user’s guide<br />
• User’s manual on CD-ROM<br />
• Calibration certificate ISO9000</p>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/">HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia HT7051 Programmable Digital 5KV Insulation Tester</title>
		<link>https://obiat.com.au/product/ht-italia-ht7051-programmable-digital-5kv-insulation-tester/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht7051-programmable-digital-5kv-insulation-tester/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 10:19:03 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2848</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<p>The HT Italia HT7051 performs professional insulation resistance measurements with test voltages from 100V to 5kVDC and has a wide measurement range up to 10Tohm. It also features Polarization Index (P.I) and Dielectric Absorption Ratio (D.A.R) tests.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht7051-programmable-digital-5kv-insulation-tester/">HT Italia HT7051 Programmable Digital 5KV Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p align="justify">The HT Italia HT7051 was designed to perform professional insulation resistance measurements with test voltage programmable up to 5KV DC and also has a wide measurement range up to 10Tohm, allowing applications for industrial LV environments (tests on electrical machines, power transformers, electrical cables, switchboard panels, generic devices, etc&#8230;)</p>
<p align="justify">Three different function modes are available on the meter: FIX mode (fixed test voltage), ADJUST mode (programmable test voltage), and RAMP mode (programmable test voltage and duration time with up to three selectable ramps) which allows for correct results in each situation.</p>
<p align="justify">The Polarization Index (P.I.) and Dielectric Absorption Ratio (D.A.R.) available features are duration tests which permits to define a good behaviour of the global insulation.</p>
<p align="justify">The HT Italia HT7051 is powered by a NiMH rechargeable battery, also having an internal memory for saving results, and an RS-232 interface for connection to a PC to transfer the saved measurements. The instrument is housed in a portable, hard carrying case which assures safety when used as an &#8220;on field&#8221; meter.</p>
<h4 align="justify"><span style="font-size: large;">HT Italia HT7051 Functions:</span></h4>
<ul>
<li>Insulation resistance measurement with test voltage up to 5kV DC.</li>
<li>Measurement range up to 10T ohm.</li>
<li>FIX Mode: with test voltages of 100V, 250V, 500V, 1000V, 2500V, and 5000V DC.</li>
<li>ADJUST Mode: with test voltage selectable from 100V<br />
to 5KV DC.</li>
<li>RAMP Mode: with selectable duration time and test voltage.</li>
<li>Selection of three types of ramp test.</li>
<li>Polarization Index measurement (P.I.).</li>
<li>Dielectric Index measurement (D.A.R.).</li>
<li>True-Rms voltage measurement up to 600V AC.</li>
<li>DC measurement to 600V.</li>
<li>SMOOTH feature for stable measurement results.</li>
<li>GUARD test lead for surface leakage current compensation.</li>
<li>Min/Max limit selectable threshold on measurements.</li>
<li>Automatic discharge of device under test.</li>
<li>Internal memory for saving results.</li>
</ul>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>KIT 14000: Set of Three safety cables with alligator clips + Two safety cables with test leads.</li>
<li>C7001: Power cord.</li>
<li>BORSA2000N: carrying case for accessories.</li>
<li>TOPVIEW: PC software + RS-232 cable.</li>
<li>Calibration certificate ISO9000.</li>
<li>User manual.</li>
</ul>
<table id="table124" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Display</td>
<td bgcolor="#C0C0C0">Backlight LCD with three simultaneous measurement reading ranges<br />
<span style="font-family: Verdana;">● Group 1: Insulation Resistance, Leakage Current, PI, DAR,<br />
Capacitance.<br />
● Group 2: Test Voltage (nominal and generated).<br />
● Group 3: Test time.</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bargraph</td>
<td bgcolor="#C0C0C0">32 segments</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Memory</td>
<td bgcolor="#C0C0C0">700 locations</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Low Battery Indication</td>
<td bgcolor="#C0C0C0">Yes symbol at display</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Communication Interface</td>
<td bgcolor="#C0C0C0">RS-232 opto-isolated</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Pollution Degree</td>
<td bgcolor="#C0C0C0">2</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Overvoltage Category</td>
<td bgcolor="#C0C0C0">CAT IV 600V to ground, maximum 600V between inputs.</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Instrument Safety</td>
<td bgcolor="#C0C0C0">CE mark<br />
IEC/EN 61010-1, IEC/EN 61557-1, IEC/EN 61557-2</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Technical Documentation</td>
<td bgcolor="#C0C0C0">IEC/EN 61187</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Accessories Safety</td>
<td bgcolor="#C0C0C0">IEC/EN 61010-031</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Reference Temperature</td>
<td bgcolor="#C0C0C0">23<span style="font-family: Verdana;">°C ±5°C</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Temperature</td>
<td bgcolor="#C0C0C0">0<span style="font-family: Verdana;">°C to 40°C</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-10<span style="font-family: Verdana;">°C to 60°C</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Relative Humidity</td>
<td bgcolor="#C0C0C0">&lt; 80% R.H.</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Humidity</td>
<td bgcolor="#C0C0C0">&lt; 80% R.H.</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply (internal battery charger)</td>
<td bgcolor="#C0C0C0">220V to 240V 50/60Hz, 20VA</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery (internal)</td>
<td bgcolor="#C0C0C0">NiMH rechargeable battery</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">Greater than 1000 tests at 5KV on 5<span style="font-family: Verdana;">MΩ range;<br />
Test time: 5 seconds; Delay between two tests: 25 seconds</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Auto Power Off</td>
<td bgcolor="#C0C0C0">approx. 5 minutes after last operation</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">360mm (L) x 310mm (W) x 195mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">approx. 3.5kg</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht7051-programmable-digital-5kv-insulation-tester/">HT Italia HT7051 Programmable Digital 5KV Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht7051-programmable-digital-5kv-insulation-tester/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia M70  1000V Insulation Meter, 200mA Continuity Meter and RMS DMM</title>
		<link>https://obiat.com.au/product/ht-italia-rcd-and-loop-testers/</link>
					<comments>https://obiat.com.au/product/ht-italia-rcd-and-loop-testers/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:39 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/ht-italia-rcd-and-loop-testers/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p align="justify">The Ht Italia M70 model is an innovative hand held meter designed to perform insulation resistance measurements with test voltages up to 1000 Volts DC and continuity test measurements of earth conductors with 200mA test current, in accordance to VDE 0100 requirements, on civil and industrial electrical environments.</p>
<p align="justify">This meter can be useful also for test on electrical equipment and switchboards according to IEC/EN 60204-1 and IEC/EN 60439-1 standards. The LOCK feature enables an insulation measurement to be performed in a continuous mode on the device under test. Duration measurements can be made using the programmable timer (2 seconds to 60 seconds), other features include AC/DC voltage measurements up to 600 volts, resistance and continuity test with buzzer as a common DMM.</p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a href="http://obiat.com.au/wp-content/uploads/2016/02/M70-Cat.pdf" target="_blank">M70 Brochure</a></h5>
<h5><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" />    <a href="http://obiat.com.au/wp-content/uploads/2016/02/ISOTEST-M70-Data-Sheet.pdf" rel="">ISOTEST M70 Data Sheet</a></h5>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/02/HT-M70-User-Manual.pdf" target="_blank">M70 User Manual</a></h5>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-rcd-and-loop-testers/">HT Italia M70  1000V Insulation Meter, 200mA Continuity Meter and RMS DMM</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>HT Italia M70</strong> is an innovative hand-held insulation tester\MegaOhmmeter designed to perform insulation resistance measurements with test voltage up to 1000VDC and continuity test measurements of earth conductors with 200mA test current, in compliance with VDE 0100 requirements, on civil and industrial electrical installations. The meter can also be employed for testing on electrical equipment and switchboards according to IEC/EN60204-1 and IEC/EN60439-1 standards.</p>
<p>Thanks to its LOCK feature insulation measurement can be performed under continuous mode on a device under test. A timer programmable from 2s to 60s enables you to carry out endurance tests as well. Other features are DC/AC voltage measurement up to 600V, resistance and continuity test with buzzer as a standard DMM. A very large and backlight custom display permits easy readings in dark environments. Small size, ergonomic shape and light weight (just 450g!) make it an essential tool for any electrical installer.</p>
<p>A hand-held meter to test insulation, voltage measurements and continuity of earth conductors.</p>
<p>HT Italia M70 is an innovative hand-held insulation resistance tester that is designed to perform insulation resistance measurements with test voltage up to 1000VDC and continuity test measurements of earth conductors with 200mA test current, in compliance with IEC/EN61557-1 requirements, on domestic and industrial electrical installations.</p>
<p>The HT Italia M70 can also be used to test electrical equipment and switchboards according to IEC/EN60204-1 and IEC/EN60439-1 standards.</p>
<p>Thanks to its LOCK feature insulation measurements can be performed on a device under test using the continuous mode.<br />
A timer is programmable from 2s to 60s enabling you to carry out endurance tests.</p>
<p>Other features are DC/AC voltage measurement up to 600V, resistance and continuity tests, with buzzer, as a digital multimeter.</p>
<p>A very large back-lit custom display permits easy readings in dark environments and its small size, ergonomic shape and light weight (just 450g!) make it an essential tool for any electrical installer.</p>
<h4><span style="font-size: large;">HT Italia M70 Functions:</span></h4>
<ul>
<li>Insulation with test voltages of 250V, 500V, and 1000V DC.</li>
<li>Up to 4G ohm measurement range.</li>
<li>Automatic discharge of device under test.</li>
<li>LOCK feature for continuous measurements.</li>
<li>Programmable timer up to 60 seconds.</li>
<li>Continuity of earth conductors with test current of 200mA.</li>
<li>Automatic test lead calibration.</li>
<li>AC/DC voltage measurement up to 600 Volts.</li>
<li>Resistance and continuity test with buzzer.</li>
<li>LCD with Bargraph and backlight.</li>
<li>AutoPower OFF.</li>
<li>Low battery indication.</li>
<li>Protective rubber holster.</li>
</ul>
<h4><span style="font-size: large;">Included Accessories:</span></h4>
<ul>
<li>Set of Two cables + Two alligator clips + Test lead.</li>
<li>Batteries 4 x 1.5V alkaline.</li>
<li>Carrying bag.</li>
<li>CE declaration of conformity.</li>
<li>User&#8217;s manual.</li>
</ul>
<h3>HT Italia M70 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellheader" colspan="2"><strong>GENERAL SPECIFICATIONS</strong></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><strong>DISPLAY</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="220">Features</td>
<td class="speccelldata">double LCD Custom 4 digit with rdg max 9999 points</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Sample rate</td>
<td class="speccelldata">2times/s</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Conversion</td>
<td class="speccelldata">Average value</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><strong>POWER SUPPLY</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="220">Batteries</td>
<td class="speccelldata">4 x1.5V type LR6-AA-AM3-MN 1500 alkaline batteries</td>
</tr>
<tr>
<td class="speccelltitle" valign="top" width="220">Life batteries</td>
<td class="speccelldata">Multimeter: about 50 hours<br />
LoΩ: &gt; 1000 test @ 1Ω<br />
MΩ 250: &gt;1000 test @ 480kΩ<br />
MΩ 500: &gt;1000 test @ 480kΩ<br />
MΩ 1000: &gt;1000 test @ 480kΩ</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><strong>MECHANICAL FEATURES</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="220">Dimensions (L x W x H)</td>
<td class="speccelldata">240 x 100 x 45mm</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Weight (included batteries)</td>
<td class="speccelldata">450g</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><strong>WORKING ENVIRONMENTAL CONDITIONS</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="220">Reference temperature</td>
<td class="speccelldata">23°C &#8211; 5°C</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Working temperature</td>
<td class="speccelldata">0° &#8211; 50°C</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Allowed relative humidity</td>
<td class="speccelldata">&lt;70%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Storage temperature</td>
<td class="speccelldata">-10 to 60°C</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Storage humidity</td>
<td class="speccelldata">&lt;70%HR</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><strong>REFERENCE STANDARDS</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="220">Continuity test with 200mA</td>
<td class="speccelldata">IEC/EN61557-4</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Insulation resistance</td>
<td class="speccelldata">IEC/EN 61557-2</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Insulation test on electrical switchboards</td>
<td class="speccelldata">IEC/EN60439-1</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Insulation test on electrical machines</td>
<td class="speccelldata">IEC/EN60204-1</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><strong>GENERAL REFERENCE STANDARDS</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="220">Safety of measuring instruments</td>
<td class="speccelldata">IEC/EN61010-1</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Product type standard</td>
<td class="speccelldata">IEC/EN61557</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Overvoltage category</td>
<td class="speccelldata">CAT III 550V (Phase – Ground)<br />
CAT III 550V (Phase – Phase)</td>
</tr>
<tr>
<td class="speccelltitle" width="220">Max height of use</td>
<td class="speccelldata">2000m</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-rcd-and-loop-testers/">HT Italia M70  1000V Insulation Meter, 200mA Continuity Meter and RMS DMM</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-rcd-and-loop-testers/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia MACROTEST-G3  Multifunction Continuity/Earth Safety Tester</title>
		<link>https://obiat.com.au/product/ht-italia-safety-tester-accessories/</link>
					<comments>https://obiat.com.au/product/ht-italia-safety-tester-accessories/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:39 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/ht-italia-safety-tester-accessories/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p align="justify"><span class="TXTSTANDARD"><span id="BLUE34">Macrotest G1 is an innovative multifunction installation tester capable of carrying out safety tests on civil and industrial electric systems in compliance with IEC/EN 61557-1. Its resistive TFT color touch-screen display, its icon menu, its help-on-line and its user-friendly development make the instrument extremely intuitive even for unskilled users.</span></span></p>
<p align="justify"><span class="TXTSTANDARD"><span id="BLUE34">Its numerous features grant the user a wide range of applications in the world of measurement. The multifunction installation tester allows saving all measurements into an internal memory so the saved data can be downloaded to a PC through a USB port (provided as standard) or built-in Wi-Fi interfaces with iOS and Android smartphones or tablets.</span></span></p>
<p align="justify"><span class="TXTSTANDARD">The Macrotest G3 also drives the optional IMP57 accessory to carry out high resolution (0.1mOhm) loop/line impedance measurements with prospective short-circuit current calibrations. Further possible tests consist in checking breakdown current, tripping current, I<sup>2</sup>t relative to breakers (MCB) with curves B, C, D, K and fuse type gG as well as aM and percentage voltage drop on the main power lines. Test on earth leakage relay tester RCDs up to 10 amps (with optional RCDX10 accessory).</span></p>
<p align="justify"><span class="TXTSTANDARD"><span id="BLUE34">The software supplied among standard accessories allows for printing of test reports. The multifunction tester has an Optional clamp (T2100) which permits to quickly check the resistance of earth probes without disconnection from the earth system.</span></span></p>
<h4 align="justify"><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></h4>
<h4 align="justify"><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <a href="http://obiat.com.au/wp-content/uploads/2016/02/G3-Data-Sheet.pdf" rel="">G3 Data Sheet</a></h4>
<p><a href="https://www.youtube.com/watch?v=8GWV_-dFBLo" target="_blank"><img class="alignnone size-medium wp-image-1647" src="http://obiat.com.au/wp-content/uploads/2016/02/VIDEO-300x169.jpg" alt="VIDEO" width="300" height="169" /> <img class="alignnone wp-image-1648" src="http://obiat.com.au/wp-content/uploads/2016/02/Play.jpg" alt="Play" width="80" height="60" /></a></p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-safety-tester-accessories/">HT Italia MACROTEST-G3  Multifunction Continuity/Earth Safety Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="font-size: large;">Functions</span></h4>
<ul>
<li>Continuity of protection conductors with 200mA.</li>
<li>Insulation resistance with 50V, 100V, 250V, 500V, 1000V DC.</li>
<li>Type A, AC, and B general, selective, and delayed RCDs up to 1000mA.</li>
<li>Test on earth leakage relay RCDs (with RCDX10 optional accessory).</li>
<li>Line/Fault impedance with prospective short circuit current calculation.</li>
<li>High resolution line/fault impedance (with IMP57 optional accessory).</li>
<li>Curve B, C, D, and K, (MCBs and gG and aM fuses)</li>
<li>Selection of length, type, and insulation of the cable under test.</li>
<li>Selection of tripping time of the protection device under test.</li>
<li>Earth resistance and soil resistivity with auxiliary rods.</li>
<li>Earth ground resistance (with T2100 optional accessory).</li>
<li>Non-trip earth loop impedance.</li>
<li>Phase sequence indication.</li>
<li>Voltage drop on main power lines measurement.</li>
<li>Power Analysis, Harmonic Analysis up to 25th.</li>
<li>Leakage current by means of the external transducer (HT96U optional accessory).</li>
<li>Environmental parameters (C/F, HR%, Lux) by means of optional probes.</li>
<li>TFT display with touch screen.</li>
<li>Help on-line.</li>
<li>Internal memory, USB interface to connect to a PC.</li>
<li>Built-in WiFi interface to connect to iOS and Android devices.</li>
<li>Rechargeable NiMH batteries (external battery charger).</li>
</ul>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li><span style="font-size: small;">C2033X Cable 3-wires with Shuko plug</span></li>
<li>KITGSC5 Set 4 cables + 4 alligator clips<br />
+ 2 test leads</li>
<li>KITTERRNE Set 4 cables + 4 metal probes</li>
<li>PR400 Remote lead per activation test</li>
<li>PT400 Touch pen</li>
<li>TOPVIEW2006 Windows software<br />
+ optical/USB cable</li>
<li>BORSA2051 Soft carrying bag</li>
<li>YABAT0003000 NiHM rechargeable battery,<br />
type &#8216;AA&#8217; 1.2V,6 pcs</li>
<li>YABAT0004000 External battery charger</li>
<li>ISO9000 calibration certificate</li>
<li>Quick reference guide</li>
<li>User manual on CD-ROM</li>
</ul>
<p>The post <a href="https://obiat.com.au/product/ht-italia-safety-tester-accessories/">HT Italia MACROTEST-G3  Multifunction Continuity/Earth Safety Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-safety-tester-accessories/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia HT7052  Programmable digital insulation tester 10 KV</title>
		<link>https://obiat.com.au/product/ht-italia-ht7052-insulation-tester/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht7052-insulation-tester/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:39 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/ht-italia-step-contact-meters/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p align="justify">The HT Italia HT-7052 is a portable battery/mains powered test instrument intended for the testing of insulation resistance by using high test voltages up to 10KV. It is a professional high voltage insulation tester with added diagnostics tools such as Polarization Index (P.I.), Dielectric Absorption Ratio )D.A.R.) and Dielectric Discharge (DD).</p>
<p align="justify">The HT-7052 is well suited for: power transformers, measuring transducers in distribution networks, testing insulation resistance of rotating machinery and cables, production line periodic testing and maintenance, troubleshooting and analysis of all kinds of insulation problems, etc. This instrument is best suited for industrial environments having CAT IV protection.</p>
<p align="justify">A dot matrix LCD offers easy-to-read results, the HT-7052 also has an internal memory for saving results, and an RS-232 interface for connection to a PC to transfer the saved measurements. The instrument is housed in a portable, hard carrying case which assures safety when used as an "on field" meter.</p>
<p>&#160;</p>
<h4><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="logopdf (2)" width="58" height="58" /> <a href="http://obiat.com.au/wp-content/uploads/2016/02/HT-7052-Data-Sheet.pdf">HT 7052 Data Sheet</a></h4>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht7052-insulation-tester/">HT Italia HT7052  Programmable digital insulation tester 10 KV</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="font-size: large;">HT Italia HT7052 Functions:</span></h4>
<ul>
<li>Insulation resistance test voltage up from 500 Volts to<br />
10000 Volts in 25 Volt DC steps.</li>
<li>Measurement range up to 10T ohm.</li>
<li>Programmable timer from 1 second to 30 minutes.</li>
<li>Diagnostic test on materials (PI, DAR, DD).</li>
<li>Insulation resistance with &#8216;RAMP&#8221; test.</li>
<li>Withstanding voltage up to 10KV DC.</li>
<li>AC/DC voltage up to 600V.</li>
<li>Capacitance measurement of device under test.</li>
<li>Automatic discharge of device under test.</li>
<li>GUARD terminal for compensation of surface currents.</li>
<li>LCD with backlight.</li>
<li>Internal memory for saving results.</li>
<li>Recall saved results at display.</li>
<li>RS-232 and USB interfaces for PC connection.</li>
<li>Rechargeable internal battery.</li>
</ul>
<h4><span style="font-size: large;">HT Italia HT7052 Included Accessories:</span></h4>
<ul>
<li>Qty 1. Test lead (red) with tip, protection 10KV, (2 meters long).</li>
<li>Qty 2. Test lead (red/black), protection 10KV, (2 meters long).</li>
<li>Qty 2. Alligator clip (red/black), Protection 10KV.</li>
<li>Qty 1. Guard test lead (green).</li>
<li>Qty 1. Guard alligator clip (green).</li>
<li>Qty 1. Mains power cord.</li>
<li>Qty 1. USB cable.</li>
<li>Qty 1. RS-232 cable.</li>
<li>Qty 1. &#8220;TeraView&#8221; software on CD-ROM.</li>
<li>Qty 6. Rechargeable NiMH batteries (1.2V) type IEC LR20.</li>
<li>Qty 1. Calibration certificate ISO9000.</li>
<li>Qty 1. User manual.</li>
</ul>