<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Multimeters Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/ht-italia/multimeters-ht-italia/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/ht-italia/multimeters-ht-italia/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Thu, 19 Dec 2024 11:06:51 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Multimeters Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/ht-italia/multimeters-ht-italia/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HT ITALIA NEPTUNE Multimeter/Insulation Tester</title>
		<link>https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 19 Jun 2019 04:41:26 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=36329</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg"><img class="alignnone size-full wp-image-3842" src="https://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="" width="166" height="91" /></a></p>
<h4>HT ITALIA NEPTUNE Features:</h4>
<ul>
<li><span style="font-size: 90%;">Autorange function &#38; automatic detection of AC, DC for all measurements.</span></li>
<li><span style="font-size: 90%;">Insulation test voltages of 50,100,250,500,1000VDC</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS voltage up to 1000V.</span></li>
<li><span style="font-size: 90%;">Low-impedance LoZ input to eliminate “stray voltages” from the measurement</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS current by means of an optional external current clamp</span></li>
<li><span style="font-size: 90%;">Measurement of voltage or current frequency.</span></li>
<li><span style="font-size: 90%;">Resistance and continuity with buzzer.</span></li>
<li><span style="font-size: 90%;">MAX/MIN/PEAK/HOLD functions.</span></li>
<li><span style="font-size: 90%;"> CAT IV 600V, CAT III 1000V Safety Rating</span></li>
<li><span style="font-size: 90%;">ISO 9000 Calibration Certificate included</span></li>
<li><span style="font-size: 90%;">Similar to the Fluke 1587 &#38; Fluke 1577</span></li>
</ul>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>     <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-Datasheet.pdf" rel="noopener noreferrer">NEPTUNE Datasheet</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-Brochure.pdf" rel="noopener noreferrer">NEPTUNE Brochure</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-User-Manual.pdf" rel="noopener noreferrer">NEPTUNE User Manual</a></span></h3>
<p>The post <a href="https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/">HT ITALIA NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT ITALIA NEPTUNE Multimeter/Insulation Tester is a mix of technology that includes an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), an Harmonics analyzer and a True  RMS multimeter.</p>
<h4>HT ITALIA NEPTUNE Key Features:</h4>
<ul>
<li>it can quickly measure insulation up to 1000V, just like top-of-the-range testers.</li>
<li>50,100,250,500,1000VDC Insulation test voltages.</li>
<li>it measures continuity of protective conductors with 200mA to solve the most common problems related to masses.</li>
<li>measure Inrush currents, Harmonics and THD%, just like top-of-the-range power quality analyzers.</li>
<li>with a wide range of external clamp transducers it can measure AC TRMS, DC, AC+DC current and Inrush current, starting from 1mA up to 3000A.</li>
<li>compare each measurement with the limits prescribed by the Guidelines and I provide a clear result OK or NOT OK</li>
<li>it&#8217;s a multimeter with functions only available if using top-of-the-range instruments.</li>
<li>CAT IV 600V, CAT III 1000V Safety Rating</li>
<li>Similar to the Fluke 1587 &amp; Fluke 1577</li>
<li>ISO 9000 CALIBRATION CERTIFICATE INCLUDED</li>
</ul>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">
<h4><strong>HT ITALIA NEPTUNE Technical Specifications</strong></h4>
</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>DC voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS, LoZ voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.5V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">32Hz ÷ 1kHz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS current with flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS current with standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Resistance and Continuity test</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0Ω ÷ 1999Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(1.0%reading + 5digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Buzzer test</span></td>
<td class="speccelldata"><span style="font-size: 90%;">R&lt;30Ω</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Voltage / Current harmonics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Harmonic order</span></td>
<td class="speccelldata"><span style="font-size: 90%;">DC, 1st ÷ 25th + THD%</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V / 0.1A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(5.0%rdg + 10digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Phase sequence with 1 terminal</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">100V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Insulation resistance</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test voltages</span></td>
<td class="speccelldata"><span style="font-size: 90%;">50,100,250,500,1000VDC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 999MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 1MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Timer for measurements</span></td>
<td class="speccelldata"><span style="font-size: 90%;">15s, 30s, 1min, 5min, 10min</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Continuity of protective conductors</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test current</span></td>
<td class="speccelldata"><span style="font-size: 90%;">&gt;200mA DC (@ R&lt;5Ω)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.00Ω ÷ 199.9Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Open-circuit voltage</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 &lt; Vo &lt; 12V DC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>General characteristics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Instrument safety</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61010-2-033</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">EMC</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61326-1</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test MΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test LoΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-4</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Phase sequence</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61557-7</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Insulation</span></td>
<td class="speccelldata"><span style="font-size: 90%;">double insulation</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Pollution level</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measurement category</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CAT IV 600V, CAT III 1000V to earth and between inputs</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Mechanical characteristics</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Size (L x W x H)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">175 x 85 x 55mm</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Weight (batteries included)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">420g</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Mechanical protection</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IP40</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Power supply</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Battery type</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4&#215;1.5V batteries type AAA IEC LR03</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Auto power off</span></td>
<td class="speccelldata"><span style="font-size: 90%;">after 15 minutes’ idling</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Display</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Type of display</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 dgt LCD, max 9999 dots, decimal sign, point, backlight and bargraph, indication of polarity</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Updating frequency</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2 times/s</span></td>
</tr>
</tbody>
</table>
<h3>HT ITALIA NEPTUNE  Included Accessories:</h3>
<p>• 4324-2 Pair of Red/Black banana connectors with 2/4mm tip<br />
• YAAMK0001HT0 Pair of Red/Black alligator clips<br />
• YABAT0001HT0 Alkaline battery type AAA IEC LR03 1.5V, 4 pieces<br />
• YABRS0002HT0 Carrying bag<br />
• YAMUM0068HT0 User manual on CD-ROM<br />
• YAMUM0067HT0 Quick user guide<br />
• Calibration certificate ISO9000</p>
<h3>Optional Accessories:</h3>
<p>• F3000U Flexible clamp with full scale 30/300/3000A AC and banana connectors<br />
• HT96U* Standard clamp with full scale 1/100/1000A AC and Hypertac connector<br />
• HT97U* Standard clamp with full scale 10/100/1000A AC and Hypertac connector<br />
• HT98U* Standard clamp with full scale 1000A DC and Hypertac connector<br />
• HT4006 Standard clamp with full scale 40/400A AC/DC and banana connectors<br />
• NOCANBA Adapter for clamp connection with Hypertac connector<br />
• 5004-IECR Red alligator clip<br />
• 5004-IECN Black alligator clip<br />
• C2065 3-wire cable Red, Black and Green with Schuko plug</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/">HT ITALIA NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT ITALIA Mercury Thermal Imaging Digital Multimeter</title>
		<link>https://obiat.com.au/product/ht-italia-mercury-thermal-imaging-digital-multimeter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 30 Jul 2018 07:37:43 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=14069</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/10/HT-Italia-Aus-small.jpg"><img class="alignnone size-full wp-image-4270" src="https://obiat.com.au/wp-content/uploads/2017/10/HT-Italia-Aus-small.jpg" alt="" width="192" height="100" /></a></p>
<p><span style="text-align: left; color: #000000; text-transform: none; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-size: 90%; font-style: normal; font-variant: normal; font-weight: 300; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">The HT ITALIA Mercury is a Professional CAT IV 600V – CAT III 1000V Digital Multimeter with built-in infrared camera &#38; comes standard with a  F3000U AC flexible clamp with 30/300/3000A full scale</span></p>
<p><span style="font-size: 90%; color: #000000;">The HT ITALIA Mercury Infrared Digital Multimeter i<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">s a </span>TRMS digital multimeter capable<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;"> of measuring</span> AC/DC voltage<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;"> up to </span>1000V<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">, </span>AC/DC<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;"> </span>current<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;"> up to </span>10A <span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">as well as </span>resistance, continuity test, diode test, frequency, capacitance and temperature with K-type probe<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">. </span></span></p>
<p><span style="font-size: 90%; color: #000000;"><span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">Other major functions include </span>AC+DC <span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">mode taking into account </span>DC <span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">components overlapping </span>AC<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;"> signals and </span>current measuremen<span style="text-align: left; text-transform: none; line-height: 26.66px; text-indent: 0px; letter-spacing: normal; font-family: Roboto, sans-serif; font-style: normal; font-variant: normal; text-decoration: none; word-spacing: 0px; white-space: normal; orphans: 2; float: none; text-shadow: none; -webkit-text-stroke-width: 0px; background-color: transparent; display: inline !important;">t with standard and flexible transducer clamps (the HT F3000U Flexible Current Clamp is included with the HT Mercury). </span></span></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>     <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/07/HT-ITALIA-Mercury-Datasheet.pdf" rel="noopener noreferrer">HT-ITALIA-Mercury-Datasheet</a></span></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/07/HT-Italia-Mercury-User-Manual.pdf" rel="noopener noreferrer">HT-Italia-Mercury-User-Manual</a></span></span></h4>
<p>The post <a href="https://obiat.com.au/product/ht-italia-mercury-thermal-imaging-digital-multimeter/">HT ITALIA Mercury Thermal Imaging Digital Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>HT ITALIA Mercury Thermal Imaging Digital Multimeter</h3>
<p>With the HT MERCURY you carry out all measurements normally performed with multimeters and IR cameras.</p>
<ul>
<li><span style="font-size: 90%;">The built-in IR camera allows you to simply and quickly detect hot spots caused by electrical problems or malfunctions.Once repair works are completed, you can check whether the problem was solved or not</span></li>
<li><span style="font-size: 90%;">The multimeter function allows you to troubleshoot installations, measuring voltage and current.</span></li>
<li><span style="font-size: 90%;">Log to my internal memory the trend of voltage and current with selectable sampling rate. The data is saved and downloaded onto the PC IR images, measurements and data recordings allow you to generate professional reports.</span></li>
<li><span style="font-size: 90%;">Connect via Bluetooth to mobile devices. In this way, the operator can set the instrument on the measuring spot, move away from a possible dangerous area and read measures on the tablet/smartphone through the App HT MERCURY.</span></li>
<li><span style="font-size: 90%;">CAT IV 600V/CAT III 1000V Safety Rating allows you to use the Mercury in industrial and domestic environments.</span></li>
<li><span style="font-size: 90%;">It can be connected to a wide range of (rigid and flexible) clamp transducers for measuring AC TRMS, DC, AC+DC current.</span></li>
<li><span style="font-size: 90%;">It can be connected to a wide range of external K-type probes to measure temperature.</span></li>
<li><span style="font-size: 90%;">Thanks to the Mercury&#8217;s colour display, detecting possible problems through a thermographic image is very easy and quick.</span></li>
<li><span style="font-size: 90%;">The two rechargeable Li-ION batteries provided allow for a long continuous working duration.</span></li>
<li><span style="font-size: 90%;">The Mercury is portable, compact and rugged and also dust-tight and protected against water ingress to IP65.</span></li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c.jpg"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-8406" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-c.jpg" alt="" width="1053" height="379" /></a></p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a.jpg"><img decoding="async" class="alignnone size-full wp-image-8407" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-a.jpg" alt="" width="1053" height="380" /></a></p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b.jpg"><img decoding="async" class="alignnone size-full wp-image-8409" src="https://rapid-tech.com.au/wp-content/uploads/2018/07/HT-Mercury-Multimeter-b.jpg" alt="" width="1054" height="374" /></a></p>
<h3>HT Mercury Multimeter Function:</h3>
<ul>
<li><span style="font-size: 90%;">DC/ AC / AC+DC TRMS voltage</span></li>
<li><span style="font-size: 90%;">DC / AC / AC+DC TRMS current</span></li>
<li><span style="font-size: 90%;">DC / AC / AC+DC TRMS current with clamp transducer</span></li>
<li><span style="font-size: 90%;">Resistance and Continuity test</span></li>
<li><span style="font-size: 90%;">Diode test</span></li>
<li><span style="font-size: 90%;">Capacitance</span></li>
<li><span style="font-size: 90%;">Frequency</span></li>
<li><span style="font-size: 90%;">Duty Cycle</span></li>
<li><span style="font-size: 90%;">Temperature with K-type probe</span></li>
<li><span style="font-size: 90%;">Data Logger function and display of graphs of measured data</span></li>
<li><span style="font-size: 90%;">Storage of BMP images on external micro SD card</span></li>
<li><span style="font-size: 90%;">CAT IV 600V – CAT III 1000V Safety Rating</span></li>
</ul>
<h3>HT Mercury Thermal Imaging Camera Function:</h3>
<ul>
<li><span style="font-size: 90%;">Infrared temperature measurement ranging from -20°C to 260°C</span></li>
<li><span style="font-size: 90%;">3 measuring cursors (central steady + hot spot + cold spot)</span></li>
<li><span style="font-size: 90%;">Emissivity of materials which can be selected between 0.01 and 1.00</span></li>
<li><span style="font-size: 90%;">Image frequency: 50Hz</span></li>
<li><span style="font-size: 90%;">5 selectable color palettes</span></li>
<li><span style="font-size: 90%;">Automatic detection of hot/cold spots of the image</span></li>
<li><span style="font-size: 90%;">Storage of BMP images on external micro SD card</span></li>
<li><span style="font-size: 90%;">IR sensor resolution: 80x80pxl</span></li>
<li><span style="font-size: 90%;">Bluetooth connection to mobile devices through the APP HTMercury</span></li>
<li><span style="font-size: 90%;">Built-in laser pointer and illuminator</span></li>
</ul>
<p><span style="font-size: 90%;">Each of these functions can be selected on the HT ITALIA Mercury Thermal Imaging Digital Multimeter by means of the appropriate switch. The instrument is also equipped with function keys, analogue bargraph and LCD TFT high-contrast color display. The instrument is also equipped with an Auto Power OFF function which automatically switches off the instrument after a certain (programmable) idling time.</span></p>
<h3>Included Accessories:</h3>
<ul>
<li><span style="font-size: 90%;">Pair of leads with 2/4mm tip (Code 4413-2)</span></li>
<li><span style="font-size: 90%;">Adapter &amp; K-type thermocouple wire probe</span></li>
<li><span style="font-size: 90%;">Flexible clamp transducer AC 30/300/3000A (Code F3000U)</span></li>
<li><span style="font-size: 90%;">Li-ION rechargeable battery, 2 pieces (Code BATMCY)</span></li>
<li><span style="font-size: 90%;">Multiplug Universal power supply + recharging base (Code A0MCY)</span></li>
<li><span style="font-size: 90%;">Alkaline battery type AAA LR03, 2 pieces</span></li>
<li><span style="font-size: 90%;">Micro SD card, 8GB</span></li>
<li><span style="font-size: 90%;">Carrying bag (Code B0MCY)</span></li>
<li><span style="font-size: 90%;">ISO9000 calibration certificate</span></li>
<li><span style="font-size: 90%;">User manuals</span></li>
</ul>
<h3>Why True RMS?</h3>
<p><span style="font-size: 90%;">Measuring instruments for AC are divided into two types: </span></p>
<ul>
<li><span style="font-size: 90%;">AVERAGE-VALUE meters: instruments measuring the value of the sole wave at fundamental frequency (50 or 60 Hz). </span></li>
<li><span style="font-size: 90%;">TRMS (True Root Mean Square) VALUE meters</span></li>
</ul>
<p><span style="font-size: 90%;">True RMS instruments measuring the TRMS value of the quantity being tested. With a perfectly sinusoidal wave, the two families of instruments provide identical results. With distorted waves, instead, the readings shall differ.</span></p>
<p><span style="font-size: 90%;">Average-value meters provide the RMS value of the sole fundamental wave; TRMS meters, instead, provide the RMS value of the whole wave, including harmonics (within the instruments bandwidth).</span></p>
<p><span style="font-size: 90%;">Therefore, by measuring the same quantity with instruments from both types, the values obtained are identical only if the wave is perfectly sinusoidal. In case it is distorted, TRMS meters shall provide higher values than the values read by average-value meters.</span></p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-mercury-thermal-imaging-digital-multimeter/">HT ITALIA Mercury Thermal Imaging Digital Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT ITALIA JUPITER Multi-Function Multimeter</title>
		<link>https://obiat.com.au/product/ht-italia-jupiter-multi-function-multimeter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 15 Oct 2017 05:22:03 +0000</pubDate>
				<guid isPermaLink="false">http://obiat.com.au/?post_type=product&#038;p=4273</guid>

					<description><![CDATA[<h4><a href="http://obiat.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO.png"><img class="alignnone size-full wp-image-952" src="http://obiat.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO.png" alt="HT ITALIA LOGO" width="160" height="100" /></a></h4>
<h4>JUPITER THE MULTI-FUNCTION MULTIMETER FOR ELECTRICAL INSTALLATION SAFETY TESTING</h4>
<p><strong>HT ITALIA </strong><b>revolutionises</b> the portable instrument market by introducing the new <strong>JUPITER</strong>.</p>
<p>The <span style="color: #ff0000;"><strong>first</strong></span> <strong>multimeter</strong> who <strong>incorporates</strong> the <strong>functions available only in standard electrical safety testers </strong>and professional <strong>High-end multimeters.</strong></p>
<ul>
<li>Test tripping time of RCDs type A and AC up to 300mA*.</li>
<li>Tripping current of RCDs type AC up to 30mA.</li>
<li>Non-trip earth ground resistance.</li>
<li>Line-to-Neutral, Line-to-Line and Line-to-Ground impedance (resolution 0.1Ohm) with prospective short-circuit/fault current calculation.</li>
<li>Current up to 3000A by means of clamp-on or flexible external transducer. ›</li>
<li>Dynamic inrush current of motors and loads through the DIRC function allowing time base selection. ›</li>
<li>Leakage current by means of the clamp-on transducer HT96U.</li>
<li>Voltage and current harmonics with THD% calculation and function to the 25th Harmonic (Higher Harmonic Ordering) showing highest harmonic values first.</li>
<li>One-lead phase sequence detection</li>
<li>JUPITER is provided with ISO9000 calibration certificate as standard.</li>
</ul>
<p><iframe src="https://www.youtube.com/embed/mpOH1QRr4lI?rel=0" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h4><a href="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png"><img class="alignnone size-full wp-image-4253" src="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline; color: #ff6600;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Jupiter-Brochure.pdf" rel="noopener">HT Jupiter Brochure</a></span></h4>
<h4><a href="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png"><img class="alignnone size-full wp-image-4253" src="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #ff6600;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Jupiter-Datasheet.pdf" rel="noopener">HT Jupiter Datasheet</a></span></span></h4>
<h4><a href="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png"><img class="alignnone size-full wp-image-4253" src="http://obiat.com.au/wp-content/uploads/2017/09/pdf_sml.png" alt="pdf_sml" width="40" height="40" /></a>    <span style="text-decoration: underline;"><span style="color: #ff6600;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Jupiter-User-Manual.pdf" rel="noopener">HT Jupiter User Manual</a></span></span></h4>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-jupiter-multi-function-multimeter/">HT ITALIA JUPITER Multi-Function Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>As professional multimeter HT ITALIA JUPITER Multi-Function Multimeter provides:</h4>
<p><strong>Autorange</strong> measurements with automatic <strong>AC/DC</strong> detection<br />
<strong>LoZ</strong> low impedance voltage input to eliminate <strong>ghost voltage</strong> readings (caused by the capacitive coupling among active conductors close each other)<br />
One-lead <strong>phase sequence detection</strong></p>
<p>JUPITER is provided with ISO9000 calibration certificate as standard.</p>
<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3.jpg"><img decoding="async" class="alignnone size-full wp-image-4278" src="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3.jpg" alt="Jupiter Banner 3" width="934" height="343" srcset="https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3.jpg 934w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3-600x220.jpg 600w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3-300x110.jpg 300w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-3-768x282.jpg 768w" sizes="(max-width: 934px) 100vw, 934px" /></a></p>
<h3>HT ITALIA JUPITER Multi-Function Multimeter Features:</h3>
<ul>
<li>Autorange measurements with automatic AC/DC detection.</li>
<li>DC, AC TRMS, AC+DC TRMS voltage up to 690V.</li>
<li>Tripping time of RCDs type A and AC up to 300mA*.</li>
<li>Tripping current of RCDs type AC up to 30mA. ›</li>
<li>Non-trip earth ground resistance. ›</li>
<li>Line-to-Neutral, Line-to-Line and Line-to-Ground impedance (resolution 0.1Ohm) with prospective short-circuit/fault current calculation.</li>
<li>Current up to 3000A by means of clamp-on or flexible external transducer.</li>
<li>Dynamic inrush current of motors and loads through the DIRC function allowing time base selection.</li>
<li>Leakage current by means of the clamp-on transducer HT96U.</li>
<li>Voltage and current harmonics with THD% calculation and function to the 25th Harmonic showing highest harmonic values first.</li>
<li>One-lead phase sequence detection.</li>
<li>Low impedance voltage input to eliminate ghost voltage readings.</li>
<li>DC, AC TRMS, AC+DC TRMS current by means of external transducer.</li>
<li>Frequency of voltage and/or current.</li>
<li>Resistance and continuity with buzzer.</li>
<li>MIN/MAX/PEAK/HOLD functions.</li>
<li>6000 count Display</li>
</ul>
<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1.jpg"><img decoding="async" class="alignnone size-full wp-image-4277" src="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1.jpg" alt="Jupiter Banner 1" width="647" height="453" srcset="https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1.jpg 647w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1-600x420.jpg 600w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-1-300x210.jpg 300w" sizes="(max-width: 647px) 100vw, 647px" /></a></p>
<h3><strong>HT ITALIA JUPITER Multi-Function Multimeter Functions</strong></h3>
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>TRMS</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>AC/DC voltage</td>
<td class="description">690V / AC+DC</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>LoZ Input</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>AC/DC current</td>
<td class="description">AC+DC with external clamp transducer</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Frequency</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Resistance and continuity test with buzzer</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>RCD tripping time</td>
<td class="description">30mA, 100mA, 300mA A/AC</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>RCD trip current measurement</td>
<td class="description">RCD A/AC 30mA</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Leakage current (with optional accessory HT96U)</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Non-trip earth resistance</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Voltage and current harmonics up to the 25th and THD%</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Electric motor starting current (INRUSH)</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Auto x1/2, x1, x2, x5, 0°, 180°</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Phase sequence</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Out come OK/NOT OK</td>
<td class="description">According with IEC60364-6</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Backlit LCD display</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Measurement category</td>
<td class="description">CAT IV 600V</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Measuring counts</td>
<td class="description">6000</td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>MAX/MIN/HOLD</td>
<td class="description"></td>
</tr>
</tbody>
<tbody>
<tr class="list-item">
<td class="function"><i class="fa fa-check"></i>Bargraph</td>
<td class="description"></td>
</tr>
</tbody>
</table>
<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2.jpg"><img decoding="async" class="alignnone size-full wp-image-4281" src="http://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2.jpg" alt="Jupiter Banner 2" width="643" height="502" srcset="https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2.jpg 643w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2-600x468.jpg 600w, https://obiat.com.au/wp-content/uploads/2017/10/Jupiter-Banner-2-300x234.jpg 300w" sizes="(max-width: 643px) 100vw, 643px" /></a></p>
<div>
<div class="row"  id="row-1366377189">

	<div id="col-846018335" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<strong>HT Instruments JUPITER Standard Accessories:</strong></p>
		</div>
					</div>

	
</div>
</div>
<div><div class="row"  id="row-139342352">
	<div id="col-1900296246" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			</div>
<div></div>
<div>• <strong>C2033AU</strong> Three wire cable Red, Black, Green with Australian plug<br />
• <strong>4324-2</strong> Pair of test tips Red/Black 2/4mm straight banana<br />
•<strong> YABAT0001HT0</strong> Alkaline battery 1.5V, type AAA, IEC LR03, 4 pcs<br />
• <strong>YABRS0002HT0</strong> Carrying bag<br />
• <strong>YAMUM0066HT0</strong> User manual on CD-ROM<br />
• <strong>YAMUM0065HT0</strong> Quick reference guide<br />
• <strong>Calibration certificate ISO9000.</strong>		</div>
					</div>

	

	<div id="col-698299651" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<figure id="attachment_5765" aria-describedby="caption-attachment-5765" style="width: 300px" class="wp-caption alignnone"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-C2033AU-accessory.jpg"><img decoding="async" class="size-medium wp-image-5765" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/HT-C2033AU-accessory-300x104.jpg" alt="" width="300" height="104" /></a><figcaption id="caption-attachment-5765" class="wp-caption-text">C2033AU Three wire cable Red, Black, Green with Australian plug</figcaption></figure>
		</div>
					</div>

	
</div>
</div>
<div> <div class="row"  id="row-346855734">
	<div id="col-2002380761" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<strong>HT Instruments JUPITER Optional Accessories:</strong>		</div>
					</div>

	</div>
<div class="row"  id="row-1110890760">
	<div id="col-1119846841" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
• <strong>F3000U</strong> AC flexible clamp with 30/300/3000A full scales<br />
• <strong>HT96U</strong>* AC current clamp with 1/100/1000A full scales<br />
• <strong>HT97U</strong>* AC current clamp with 10/100/1000A AC full scales<br />
• <strong>HT98U</strong>* DC current clamp with 1000A full scale<br />
• <strong>HT4006</strong> AC/DC current clamp with 40/400A full scales<br />
• <strong>NOCANBA</strong> Hypertac-to-banana adapter* Adapter NOCANBA required.		</div>
					</div>

	

	<div id="col-1638247240" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<figure id="attachment_5767" aria-describedby="caption-attachment-5767" style="width: 375px" class="wp-caption alignnone"><a href="https://rapid-tech.com.au/wp-content/uploads/2017/10/Jupiter-Clamps.png"><img decoding="async" class="size-full wp-image-5767" src="https://rapid-tech.com.au/wp-content/uploads/2017/10/Jupiter-Clamps.png" alt="" width="375" height="215" /></a><figcaption id="caption-attachment-5767" class="wp-caption-text">F3000U &amp; HT4006 Clamps</figcaption></figure>
		</div>
					</div>

	
</div>
</div>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-jupiter-multi-function-multimeter/">HT ITALIA JUPITER Multi-Function Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT ITALIA HT64 TRMS/AC+DC Digital Multimeter with colour LCD display</title>
		<link>https://obiat.com.au/product/ht-instruments-ht64-trmsacdc-digital-multimeter-colour-lcd-display/</link>
					<comments>https://obiat.com.au/product/ht-instruments-ht64-trmsacdc-digital-multimeter-colour-lcd-display/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 18 May 2016 07:56:03 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=3528</guid>

					<description><![CDATA[<p><a href="http://obiat.com.au/wp-content/uploads/2016/05/HTI-Auth-Large.jpg"><img class="alignnone size-full wp-image-4283" src="http://obiat.com.au/wp-content/uploads/2016/05/HTI-Auth-Large.jpg" alt="HTI Auth Large" width="350" height="160" /></a></p>
<h4>HT INSTRUMENTS HT64 Digital Multimeter</h4>
<p>Its's not by accident that the new series of HT60 series  professional multimeters are so rugged and well spec'd as they are the result of research conducted with the most demanding users of this kind of equipment, namely laboratories, where the choice of a measuring instrument is subject to strict tests concerning <strong>precision</strong>, <strong>reliability</strong> and <strong>safety of measurements even in extreme conditions</strong>.</p>
<p>The HT Instruments new HT60 series is a complete range of professional <strong>CAT IV 600V</strong> multimeters, all able to measure in <strong>TRMS</strong>, autorange function is available on all models and with backlit display. The design is modern, but also ergonomic, to ensure maximum ease of use. They display with a high resolution, even in colour for the premium model HT64.<br />
<iframe src="http://www.youtube.com/embed/R89V12uRKF8?&#38;rel=0" width="560" height="315" frameborder="0" allowfullscreen="allowfullscreen"></iframe></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<h4><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://obiat.com.au/wp-content/uploads/2016/05/HT60-series-Multimeter-Brochure.pdf">HT60 series Multimeter Brochure</a></h4>
<h4><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://obiat.com.au/wp-content/uploads/2016/05/HT64-Datasheet.pdf">HT64 Datasheet</a></h4>
<h4><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://obiat.com.au/wp-content/uploads/2016/05/HT64-User-Manual.pdf">HT64 User Manual</a></h4>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/ht-instruments-ht64-trmsacdc-digital-multimeter-colour-lcd-display/">HT ITALIA HT64 TRMS/AC+DC Digital Multimeter with colour LCD display</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h5>HT ITALIA HT64 TRMS / CAT IV PROFESSIONAL DIGITAL MULTIMETER WITH DATA LOGGER FUNCTIONS.</h5>
<p><img decoding="async" class="alignnone wp-image-3971" src="http://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-3L.jpg" alt="ht64-dmm-3l" width="958" height="337" srcset="https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-3L.jpg 1569w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-3L-600x211.jpg 600w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-3L-300x106.jpg 300w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-3L-768x270.jpg 768w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-3L-1024x360.jpg 1024w" sizes="(max-width: 958px) 100vw, 958px" /></p>
<p>The new HT ITALIA HT64 professional multimeter is the result of an in depth research conducted with the most demanding users of this kind of equipment, namely laboratories, where the choice of a measuring instrument is subject to strict tests concerning precision, reliability and safety of measurements even in extreme conditions. Therefore the HT 60 series is a complete range multimeters, all able to measure in TRMS, all with CAT IV 600V Safety Rating, autorange function available on all models, with backlight display.</p>
<h5>HT Italia HT64 Measurement Features:</h5>
<ul>
<li>DC voltage</li>
<li>AC, AC+DC TRMS Voltage</li>
<li>DC current</li>
<li>4-20mA% display</li>
<li>AC, AC+DC TRMS current</li>
<li>Resistance and Continuity test</li>
<li>Diode test</li>
<li>Capacitance</li>
<li>Frequency</li>
<li>Duty Cycle</li>
<li>Temperature with K-type probe</li>
<li>Data Logger function and display of graphs of measured data</li>
</ul>
<p>These features that make this range of professional instruments unique and invaluable.</p>
<p><img decoding="async" class="alignnone wp-image-3972" src="http://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-2L.jpg" alt="ht64-dmm-2l" width="942" height="470" srcset="https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-2L.jpg 1534w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-2L-600x299.jpg 600w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-2L-300x150.jpg 300w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-2L-768x383.jpg 768w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-2L-1024x511.jpg 1024w" sizes="(max-width: 942px) 100vw, 942px" /></p>
<h4><strong>HT ITALIA HT64 Specifications:</strong></h4>
<h5>1. ELECTRICAL SPECIFICATIONS</h5>
<p>Accuracy calculated as ±[%reading + (num dgt * resolution)] at 18°C ¸ 28°C, &lt;75%HR</p>
<h5>DC VOLTAGE</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="95"><strong>Resolution</strong></td>
<td width="142"><strong>Accuracy</strong></td>
<td width="135"><strong>Input impedance</strong></td>
<td width="192"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87">600.0mV</td>
<td width="95">0.1mV</td>
<td rowspan="3" width="142">±(0.1%rdg+5dgt)</td>
<td rowspan="5" width="135">10MΩ</td>
<td rowspan="5" width="192">1000VDC/ACrms</td>
</tr>
<tr>
<td width="87">6.000V</td>
<td width="95">0.001V</td>
</tr>
<tr>
<td width="87">60.00V</td>
<td width="95">0.01V</td>
</tr>
<tr>
<td width="87">600.0V</td>
<td width="95">0.1V</td>
<td rowspan="2" width="142">±(0.2%rdg+5dgt)</td>
</tr>
<tr>
<td width="87">1000V</td>
<td width="95">1V</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<h5>AC TRMS VOLTAGE</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="95"><strong>Resolution</strong></td>
<td width="142"><strong>Accuracy (*)</strong></p>
<p><strong>50Hz </strong><strong>¸</strong><strong> 60Hz</strong></td>
<td width="132"><strong>Accuracy (*)</strong></p>
<p><strong>61Hz </strong><strong>¸</strong><strong> 1kHz</strong></td>
<td width="194"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87">600.0mV</td>
<td width="95">0.1mV</td>
<td rowspan="5" width="142">±(0.9%rdg+5dgt)</td>
<td rowspan="5" width="132">±(3.0%rdg+5dgt)</td>
<td rowspan="5" width="194">1000VDC/ACrms</td>
</tr>
<tr>
<td width="87">6.000V</td>
<td width="95">0.001V</td>
</tr>
<tr>
<td width="87">60.00V</td>
<td width="95">0.01V</td>
</tr>
<tr>
<td width="87">600.0V</td>
<td width="95">0.1V</td>
</tr>
<tr>
<td width="87">1000V</td>
<td width="95">1V</td>
</tr>
</tbody>
</table>
<p>(*) Accuracy specified from 5% to 100% of measurement range, Input impedance: &gt;9MΩ,</p>
<p>Response time PEAK function: &gt;1ms, Accuracy PEAK function: ±10%rdg</p>
<p>&nbsp;</p>
<h5>AC+DC TRMS VOLTAGE</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="95"><strong>Resolution</strong></td>
<td width="142"><strong>Accuracy (*)</strong></p>
<p><strong>50Hz </strong><strong>¸</strong><strong> 1kHz</strong></td>
<td width="132"><strong>Input impedance</strong></td>
<td width="194"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87">6.000V</td>
<td width="95">0.001V</td>
<td rowspan="4" width="142">±(3.0%rdg+20dgt)</td>
<td rowspan="4" width="132">&gt;9MΩ</td>
<td rowspan="4" width="194">1000VDC/ACrms</td>
</tr>
<tr>
<td width="87">60.00V</td>
<td width="95">0.01V</td>
</tr>
<tr>
<td width="87">600.0V</td>
<td width="95">0.1V</td>
</tr>
<tr>
<td width="87">1000V</td>
<td width="95">1V</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h5>DC CURRENT</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="95"><strong>Resolution</strong></td>
<td width="142"><strong>Accuracy</strong></td>
<td width="327"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87">600.0mA</td>
<td width="95">0.1mA</td>
<td rowspan="3" width="142">±(0.9%rdg+5dgt)</td>
<td rowspan="4" width="327">Fast Fuse 0.8A/1kVAC/DC (inputs mA, mA)</td>
</tr>
<tr>
<td width="87">6000mA</td>
<td width="95">1mA</td>
</tr>
<tr>
<td width="87">60.00mA</td>
<td width="95">0.01mA</td>
</tr>
<tr>
<td width="87">600.0mA</td>
<td width="95">0.1mA</td>
<td width="142">±(0.9%rdg+8dgt)</td>
</tr>
<tr>
<td width="87">10.00A</td>
<td width="95">0.01A</td>
<td width="142">±(1.5%rdg+8dgt)</td>
<td width="327">Fast Fuse 10A/1kVAC/DC (input 10A)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h5>AC, AC+DC TRMS CURRENT</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="95"><strong>Resolution</strong></td>
<td width="142"><strong>Accuracy (*)</strong></p>
<p><strong>50Hz </strong><strong>¸</strong><strong> 1kHz</strong></td>
<td width="327"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87">600.0mA</td>
<td width="95">0.1mA</td>
<td rowspan="4" width="142">±(1.2%rdg+5dgt)</td>
<td rowspan="4" width="327">Fast Fuse 0.8A/1kVAC/DC (inputs mA, mA)</td>
</tr>
<tr>
<td width="87">6000mA</td>
<td width="95">1mA</td>
</tr>
<tr>
<td width="87">60.00mA</td>
<td width="95">0.01mA</td>
</tr>
<tr>
<td width="87">600.0mA</td>
<td width="95">0.1mA</td>
</tr>
<tr>
<td width="87">10.00A</td>
<td width="95">0.01A</td>
<td width="142">±(1.5%rdg+5dgt)</td>
<td width="327">Fast Fuse 10A/1kVAC/DC (input 10A)</td>
</tr>
</tbody>
</table>
<p>(*)Accuracy specified from 5% to 100% of measurement range</p>
<p>Response time PEAK function: &gt;1ms, Accuracy PEAK function: ±10%rdg</p>
<p>AC+DC TRMS Current: accuracy (50Hz¸1kHz): ±(3.0%rdg + 20dgt)</p>
<p>&nbsp;</p>
<h5>4-20mA% READINGS</h5>
<table width="650">
<tbody>
<tr>
<td width="96"><strong>Range</strong></td>
<td width="113"><strong>Resolution</strong></td>
<td width="161"><strong>Accuracy</strong></td>
<td width="279"><strong>Reading</strong></td>
</tr>
<tr>
<td width="96">-25% ÷ 125%</td>
<td width="113">0.1%</td>
<td width="161">±50dgt</td>
<td width="279">0mA=-25%, 4mA=0%, 20mA=100%, 24mA=125%</td>
</tr>
</tbody>
</table>
<h5>DIODE TEST</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="227"><strong>Max test current</strong></td>
<td width="151"><strong>Open voltage</strong></td>
<td width="185"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87"></td>
<td width="227">&lt;1.5mA</td>
<td width="151">3.2V</td>
<td width="185">1000VDC/ACrms</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h5>RESISTANCE AND CONTINUITY TEST</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="85"><strong>Resolution</strong></td>
<td width="142"><strong>Accuracy</strong></td>
<td width="151"><strong>Buzzer</strong></td>
<td width="185"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87">600.0Ω</td>
<td width="85">0.1Ω</td>
<td width="142">±(0.8%rdg+10dgt)</td>
<td rowspan="6" width="151">&lt;50Ω</td>
<td rowspan="6" width="185">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>1000VDC/ACrms</td>
</tr>
<tr>
<td width="87">6.000kΩ</td>
<td width="85">0.001kΩ</td>
<td rowspan="4" width="142">±(0.8%rdg+5dgt)</td>
</tr>
<tr>
<td width="87">60.00kΩ</td>
<td width="85">0.01kΩ</td>
</tr>
<tr>
<td width="87">600.0kΩ</td>
<td width="85">0.1kΩ</td>
</tr>
<tr>
<td width="87">6.000MΩ</td>
<td width="85">0.001MΩ</td>
</tr>
<tr>
<td width="87">60.00MW</td>
<td width="85">0.01MΩ</td>
<td width="142">±(2.5%rdg+10dgt)</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<h5>FREQUENCY (Electronic circuits)</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="85"><strong>Resolution</strong></td>
<td width="142"><strong>Accuracy</strong></td>
<td width="151"><strong>Sensitivity</strong></td>
<td width="185"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87">60.00Hz</td>
<td width="85">0.01Hz</td>
<td rowspan="6" width="142">±(0.09%rdg+5dgt)</td>
<td rowspan="6" width="151">2Vrms min</p>
<p>(20% &lt; duty &lt; 80%, &lt;100kHz)</p>
<p>5Vrms min</p>
<p>(20% &lt; duty &lt; 80%, &gt;100kHz)</td>
<td rowspan="6" width="185">1000VDC/ACrms</td>
</tr>
<tr>
<td width="87">600.0Hz</td>
<td width="85">0.1Hz</td>
</tr>
<tr>
<td width="87">6.000kHz</td>
<td width="85">0.001kHz</td>
</tr>
<tr>
<td width="87">60.00kHz</td>
<td width="85">0.01kHz</td>
</tr>
<tr>
<td width="87">600.0kHz</td>
<td width="85">0.1kHz</td>
</tr>
<tr>
<td width="87">1.000MHz</td>
<td width="85">0.001MHz</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<h5>FREQUENCY (Electrical circuits)</h5>
<table width="650">
<tbody>
<tr>
<td width="172"><strong>Range</strong></td>
<td width="113"><strong>Resolution</strong></td>
<td width="104"><strong>Accuracy</strong></td>
<td width="76"><strong>Sensitivity</strong></td>
<td width="185"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="172">40Hz ¸ 10kHz</td>
<td width="113">0.01Hz¸0.001kHz</td>
<td width="104">±(0.5%rdg)</td>
<td width="76">2Vrms</td>
<td width="185">1000VDC/ACrms</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<h5>DUTY CYCLE</h5>
<table width="650">
<tbody>
<tr>
<td width="87"><strong>Range</strong></td>
<td width="85"><strong>Resolution</strong></td>
<td width="198"><strong>Accuracy</strong></td>
<td width="279"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="87">0.1 ¸ 99.9%</td>
<td width="85">0.01%</td>
<td width="198">±(1.2%rdg+2dgt)</td>
<td width="279">1000VDC/ACrms</td>
</tr>
</tbody>
</table>
<p>Pulse frequency range: 40Hz ¸ 10kHz, Pulse width: ±5V (100ms ¸ 100ms)</p>
<p><strong> </strong></p>
<h5>CAPACITANCE</h5>
<table width="650">
<tbody>
<tr>
<td width="96"><strong>Range</strong></td>
<td width="113"><strong>Resolution</strong></td>
<td width="161"><strong>Accuracy</strong></td>
<td width="279"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="96">60.00nF</td>
<td width="113">0.01nF</td>
<td width="161">±(1.5%rdg+20dgt)</td>
<td rowspan="6" width="279">1000VDC/ACrms</td>
</tr>
<tr>
<td width="96">600.0nF</td>
<td width="113">0.1nF</td>
<td width="161">±(1.2%rdg+8dgt)</td>
</tr>
<tr>
<td width="96">6.000mF</td>
<td width="113">0.001mF</td>
<td width="161">±(1.5%rdg+8dgt)</td>
</tr>
<tr>
<td width="96">60.00mF</td>
<td width="113">0.01mF</td>
<td width="161">±(1.2%rdg+8dgt)</td>
</tr>
<tr>
<td width="96">600.0mF</td>
<td width="113">0.1mF</td>
<td width="161">±(1.5%rdg+8dgt)</td>
</tr>
<tr>
<td width="96">6.000mF</td>
<td width="113">0.001mF</td>
<td width="161">±(2.5%rdg+20dgt)</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<h5>TEMPERATURE WITH TYPE K PROBE</h5>
<table width="650">
<tbody>
<tr>
<td width="115"><strong>Range</strong></td>
<td width="95"><strong>Resolution</strong></td>
<td width="161"><strong>Accuracy (*)</strong></td>
<td width="279"><strong>Overload protection</strong></td>
</tr>
<tr>
<td width="115">-40.0°C ÷ 600.0°C</td>
<td width="95">0.1°C</td>
<td rowspan="2" width="161">±(1.5%rdg+3°C)</td>
<td rowspan="4" width="279">1000VDC/ACrms</td>
</tr>
<tr>
<td width="115">600°C ÷ 1350°C</td>
<td width="95">1°C</td>
</tr>
<tr>
<td width="115">-40.0°F ÷  600.0°F</td>
<td width="95">0.1°F</td>
<td rowspan="2" width="161">±(1.5%rdg+5.4°F)</td>
</tr>
<tr>
<td width="115">600°F ÷  2462°F</td>
<td width="95">1°F</td>
</tr>
</tbody>
</table>
<p>(*)Accuracy referred to instrument without probe</p>
<h4><strong>HT Italia HT64  GENERAL SPECIFICATIONS:</strong></h4>
<p><strong>Display:</strong></p>
<ul>
<li>TFT LCD, colours, 4½ dgt, 6000 counts, decimal point and bargraph</li>
<li>Automatic polarity indication</li>
<li>Backlight</li>
<li>“<strong>OL</strong>” over range indication</li>
<li>Response time: 3/s</li>
</ul>
<p><img decoding="async" class="alignnone wp-image-3973" src="http://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-4L.jpg" alt="ht64-dmm-4l" width="676" height="484" srcset="https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-4L.jpg 1125w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-4L-600x429.jpg 600w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-4L-300x215.jpg 300w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-4L-768x550.jpg 768w, https://obiat.com.au/wp-content/uploads/2016/05/HT64-DMM-4L-1024x733.jpg 1024w" sizes="(max-width: 676px) 100vw, 676px" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/ht-instruments-ht64-trmsacdc-digital-multimeter-colour-lcd-display/">HT ITALIA HT64 TRMS/AC+DC Digital Multimeter with colour LCD display</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-instruments-ht64-trmsacdc-digital-multimeter-colour-lcd-display/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT ITALIA HT326 CAT IV Digital Multimeter with Capacitance and Duty Cycle</title>
		<link>https://obiat.com.au/product/ht-italia-ht326-cat-iv-digital-multimeter-capacitance-duty-cycle/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht326-cat-iv-digital-multimeter-capacitance-duty-cycle/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 22 Mar 2016 04:30:22 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1960</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p>Provides all the essential features in a compact and easy-to-use instrument developed for every-day use.</p>
<p>A rugged design and accurate measurements make this digital multi-meter the ideal choice for electricians, HVAC technicians etc.</p>
<p>Used for both maintenance and troubleshooting.</p>
<p>The HT326 is designed to safety category CAT IV 600V.</p>
<p>&#160;</p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<h4><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="HT 8000 Data Sheet" width="58" height="58" /> <a href="http://obiat.com.au/wp-content/uploads/2016/03/HT-326-DMM-Data-Sheet.pdf" rel="">HT 326 DMM Data Sheet</a></h4>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht326-cat-iv-digital-multimeter-capacitance-duty-cycle/">HT ITALIA HT326 CAT IV Digital Multimeter with Capacitance and Duty Cycle</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>The HT ITALIA HT326 performs:</strong></p>
<p>Voltage measurements AC/DC and current measurements AC/DC up to 10A maximum.<br />
Plus resistance, continuity and diode tests, along with capacitance, frequency and duty cycle as sub-features.</p>
<p><strong>HT ITALIA HT326 Functions:</strong></p>
<ul>
<li>HOLD function, relative function and manual range selection</li>
<li>In compliance to EN 61010-1 safety standard with double insulation protection</li>
<li>Large LCD display with backlight</li>
<li>Each measurement function can be selected with a rotating selector dial with 10 positions</li>
<li>AutoPowerOff function is integrated to preserve the battery after 15 minutes of inactivity</li>
<li></li>
</ul>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht326-cat-iv-digital-multimeter-capacitance-duty-cycle/">HT ITALIA HT326 CAT IV Digital Multimeter with Capacitance and Duty Cycle</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht326-cat-iv-digital-multimeter-capacitance-duty-cycle/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT ITALIA HT322 Digital Multimeter with Temperature Measurement CAT IV</title>
		<link>https://obiat.com.au/product/ht-italia-ht322-digital-multimeter-temperature-measurement-cat-iv/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht322-digital-multimeter-temperature-measurement-cat-iv/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 22 Mar 2016 03:29:26 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1953</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p>&#160;</p>
<h5><span id="ContentPlaceHolder1_lblProductDescription">The meter performs basic Voltage AC and DC measurements up to 600V, plus resistance, continuity and diode tests as sub-features.</span></h5>
<h5>With the added option of temperature measurements °C/°F using optional external type K probes.</h5>
<h5>Features<br />
 DC Voltage<br />
 AC Voltage<br />
 Resistance<br />
 Continuity test with buzzer<br />
 Diode test<br />
 Temperature with type K probes<br />
 MAX function<br />
 HOLD function<br />
 Manual Range function<br />
 Auto Power OFF<br />
STANDARD ACCESSORIES<br />
4413-2 : Test leads<br />
B80 : Soft Carrying Case<br />
Batteries<br />
User manual</h5>
<h4><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></h4>
<h4><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="HT 8000 Data Sheet" width="58" height="58" /> <a href="http://obiat.com.au/wp-content/uploads/2016/03/HT-322-DMM-Data-Sheet.pdf" rel="">HT 322 DMM Data Sheet</a></h4>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht322-digital-multimeter-temperature-measurement-cat-iv/">HT ITALIA HT322 Digital Multimeter with Temperature Measurement CAT IV</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia HT322 model is one of meter of last family 320, which include also model HT321, HT326 and HT327, designed on safety measure category CAT IV 600V. The meter performs basically Voltage AC and DC measures up to 600V and resistance, test continuity and diode test as sub-features, more than temperature measurements °C/°F with external type K probes. HT322 is in compliance to EN 61010-1 safety standard with double insulation protection. HT322 meter have a large LCD display and each measurement function can be selected with a rotative selector at 6 positions. Other features are MAX measurement, HOLD function and manual range selection. An AutoPowerOff function is integrated to preserve the internal battery after 15 minutes of idle.</p>
<h3>Specifications</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">General Specifications               Full Scale</td>
</tr>
<tr>
<td class="speccelltitle" width="200">DC Voltage Range</td>
<td class="speccelldata">200.0mV &#8211; 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="200">AC Voltage Range</td>
<td class="speccelldata">200.0mV &#8211; 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Resistance Range</td>
<td class="speccelldata">200.0Ω &#8211; 20.00MΩ</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Operating temperature</td>
<td class="speccelldata">-5°C to 40°C, &lt;80%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Storage temperature</td>
<td class="speccelldata">-10°C to 60°C, &lt;70%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Power supply</td>
<td class="speccelldata">2 x 1.5V alkaline batteries type AAA MN2400 LR03 AM4</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Sizes</td>
<td class="speccelldata">163(L)x88(W)x48(H) mm</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Weight (included batteries)</td>
<td class="speccelldata">280g</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht322-digital-multimeter-temperature-measurement-cat-iv/">HT ITALIA HT322 Digital Multimeter with Temperature Measurement CAT IV</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht322-digital-multimeter-temperature-measurement-cat-iv/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT ITALIA  HT321 CAT IV 600V Digital Multimeter</title>
		<link>https://obiat.com.au/product/ht-italia-ht321-cat-iv-600v-digital-multimeter/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht321-cat-iv-600v-digital-multimeter/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 22 Mar 2016 03:12:12 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1950</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<h5>Features<br />
 DC Voltage<br />
 AC Voltage<br />
 Resistance<br />
 Continuity test with buzzer<br />
 Diode test<br />
 MAX function<br />
 HOLD function<br />
 Manual Range function<br />
 Auto Power OFF</h5>
<h5>STANDARD ACCESSORIES<br />
4413-2 : Test leads<br />
Protection rubber holster<br />
Battery<br />
User manual</h5>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<h4><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="HT 8000 Data Sheet" width="58" height="58" /> <a href="http://obiat.com.au/wp-content/uploads/2016/03/HT-321-DMM-Data-Sheet.pdf" rel="">HT 321 DMM Data Sheet</a></h4>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht321-cat-iv-600v-digital-multimeter/">HT ITALIA  HT321 CAT IV 600V Digital Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div>
<p><strong>HT Italia HT321 CAT IV Digital Multimeter</strong></p>
<p>HT321 model is a member of the 320 family of multimeters, which include also model HT322, HT326 and HT327, designed for safety measurement category CAT IV 600V.</p>
</div>
<div>The meter performs Voltage AC and DC measures up to 600V and resistance, test continuity and diode test as sub-features.</div>
<div>HT321 is in compliance to EN 61010-1 safety standard with double insulation protection.HT32 meter have a large LCD display and each measurement function can be selected with a rotative selector at 6 positions.</div>
<div>Other features are MAX measurement, HOLD function and manual range selection. An AutoPowerOff function is integrated to preserve the internal battery after 15 minutes of idle.</div>
<div></div>
<div>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">General Specifications</td>
</tr>
<tr>
<td class="speccelltitle" width="200">DC Voltage range</td>
<td class="speccelldata">200.0mV &#8211; 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="200">DC Voltage range</td>
<td class="speccelldata">200.0mV &#8211; 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Resistance range</td>
<td class="speccelldata">200.0Ω &#8211; 20.00MΩ</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Operating temperature</td>
<td class="speccelldata">-5°C to 40°C, &lt;80%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Storage temperature</td>
<td class="speccelldata">-10°C to 60°C, &lt;70%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Power supply</td>
<td class="speccelldata">2 x 1.5V alkaline batteries type AAA MN2400 LR03 AM4</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Sizes</td>
<td class="speccelldata">163(L)x88(W)x48(H) mm</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Weight (included batteries)</td>
<td class="speccelldata">280g</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht321-cat-iv-600v-digital-multimeter/">HT ITALIA  HT321 CAT IV 600V Digital Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht321-cat-iv-600v-digital-multimeter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT ITALIA HT210 Digital Multimeter with Temperature</title>
		<link>https://obiat.com.au/product/ht-italia-ht210-digital-multimeter-temperature/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht210-digital-multimeter-temperature/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 18 Mar 2016 01:10:47 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1854</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p>Designed in compliance with <strong>safety standard IEC/ EN61010-1</strong> with double protective insulation in<strong> CAT III 600V</strong>. They are provided with a wide LCD display with backlight and each function can be selected through its relevant switch. A further function of this device is Data HOLD to freeze data on the display and REL for relative measurements.</p>
<ul>
<li>
<h5>DC voltage up to 600V</h5>
</li>
<li>
<h5>AC voltage up to 600V</h5>
</li>
<li>
<h5>Resistance</h5>
</li>
<li>
<h5>Continuity test</h5>
</li>
<li>
<h5>Diode test</h5>
</li>
<li>
<h5>Data Hold</h5>
</li>
<li>
<h5>AutoPowerOFF</h5>
</li>
<li>
<h5>Cat III 600V</h5>
</li>
</ul>
<h4><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></h4>
<h4><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="HT 8000 Data Sheet" width="58" height="58" /> <a href="http://obiat.com.au/wp-content/uploads/2016/03/HT-210-DMM-Data-Sheet.pdf" rel="">HT 210 DMM Data Sheet</a></h4>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht210-digital-multimeter-temperature/">HT ITALIA HT210 Digital Multimeter with Temperature</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>HT Italia HT210 model is a compact digital multimeter in complete autorange designed to perform basically voltage AC/DC measurements up to 600V, more than resistance, continuity test, diode test, frequency, capacitance, duty cycle and temperature with type K probe as sub-features. The meter is in compliance with IEC/EN 61010-1 safety standard with double insulation protection in CAT III 600V. HT ITALIA HT210 has a large LCD backlight display and each measurement function can be selected with a rotary selector at 7 positions. Other features are HOLD function and REL for relative measurement. An Auto PowerOff function is integrated to preserve the internal battery after 30 minutes of idleness.</p>
<p><strong>HT ITALIA HT210 F</strong><strong>unctions:</strong></p>
<ul>
<li>DC Voltage</li>
<li>AC Voltage</li>
<li>Resistance and continuity test with buzzer.</li>
<li>Diode test</li>
<li>Capacitance</li>
<li>Frequency</li>
<li>Duty cycle</li>
<li>Temperature with type K probe</li>
<li>Data HOLD</li>
<li>RELative mode</li>
<li>Complete autorange</li>
<li>Backlight</li>
<li>AutoPowerOFF</li>
</ul>
<p><strong> HT ITALIA HT210 </strong><strong>GENERAL SPECIFICATIONS:</strong></p>
<p><strong> </strong><strong>Display:</strong></p>
<ul>
<li>LCD, 3 ½ dgt, 4000 points plus sign and decimal point</li>
<li>Automatic polarity indication</li>
<li>Backlight</li>
<li>“<strong>OL</strong>” overrange indication</li>
</ul>
<p><strong>Features:</strong></p>
<ul>
<li>HOLD</li>
<li>REL</li>
<li>AutoPowerOFF after 30 minutes of idleness</li>
</ul>
<p><strong>Low battery indication:</strong></p>
<ul>
<li>&#8221; &#8221; appears when the battery voltage is low</li>
</ul>
<p><strong>Operating temperature:</strong></p>
<ul>
<li>0°C to 50°C, &lt;70%HR</li>
</ul>
<p><strong>Storage temperature:</strong></p>
<ul>
<li>-20°C to 60°C, &lt;80%HR</li>
</ul>
<p><strong>General information:</strong></p>
<ul>
<li>Max altitude: 2000m</li>
<li>Pollution degree: 2</li>
<li>Insulation: double insulation</li>
</ul>
<p><strong>Power supply:</strong></p>
<ul>
<li>1x9V battery NEDA 1604 IEC 6F22</li>
</ul>
<p><strong>Size:</strong></p>
<ul>
<li>138(L)x68(W)x37(H) mm</li>
</ul>
<p><strong>Weight (included battery):</strong></p>
<ul>
<li>210g</li>
</ul>
<p><strong>Applied standards:</strong></p>
<ul>
<li>LVD: IEC/EN 61010-1 CAT III 600V</li>
<li>EMC: EN60326</li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht210-digital-multimeter-temperature/">HT ITALIA HT210 Digital Multimeter with Temperature</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht210-digital-multimeter-temperature/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia HT8100 Process Calibrator/Multimeter</title>
		<link>https://obiat.com.au/product/ht-italia-ht8100-process-calibratormultimeter/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht8100-process-calibratormultimeter/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 18 Mar 2016 00:29:38 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1843</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p align="justify">The HT8100 is a meter performing measurements as TRMS DMM as well as a process calibrator generating 0-20mA and 4-20mA DC current signals. As DMM the instrument carries out AC/DC/AC+DC voltage measurements up to 1000V and AC/DC/AC+DC current measurements up to 1A.</p>
<p align="justify">Under the current generation mode you can manually select between 0 to 20mA and 4-20mA as well as automatic ramps on output signal. It is capable of measuring current absorbed by external transducers simulating a current adjustable within the whole measuring range.</p>
<p align="justify">The instrument can store measurement results into an internal memory and is designed in compliance with safety standards IEC/EN61010-1 according to CAT III 1000V and CAT IV 600V with double insulation protection.</p>
<p align="justify"><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<h4 align="justify"><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="HT 8000 Data Sheet" width="58" height="58" /><a href="http://obiat.com.au/wp-content/uploads/2016/03/HT8100-Data-Sheet.pdf" rel="">HT8100 Data Sheet</a></h4>
<p align="justify">
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht8100-process-calibratormultimeter/">HT Italia HT8100 Process Calibrator/Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia HT8100 is a professional meter performing measurements as TRMS DMM as well as process calibrator generating 0-20mA and 4-20mA DC current signals. As a DMM, the instrument carries out AC/DC/AC+DC voltage measurements up to 1000V and AC/DC/AC+DC current measurements up to 1A. Under the current generation mode you can manually select between 0-20mA and 4-20mA as well as automatic ramps on output signal. It is capable of measuring the current absorbed by external transducers simulating a current adjustable within the whole measuring range. The instrument can store measurement results into an internal memory and is designed in compliance with safety standards IEC/EN61010-1 according to CAT III 1000V and CAT IV 600V with double insulation protection. Each function can be selected through corresponding keys. This instrument is typically used in the automation field.</p>
<p><span style="font-size: large;">HT Italia HT8100 Functions:</span></p>
<ul>
<li>DC/AC TRMS Voltage.</li>
<li>DC/AC TRMS Current.</li>
<li>AC+DC Measurements.</li>
<li>Generation of output current signal up to 24mA DC.</li>
<li>Selection 0-20mA and 4-20mA output.</li>
<li>Up to 4 available automatic ramp.</li>
<li>Loop current measurement of external transducers.</li>
<li>250 Ohm HART feature.</li>
<li>Simulating of external transducers.</li>
<li>Resistance and continuity test.</li>
<li>Diode Test.</li>
<li>Frequency, Data Hold, Min/Max/AVG.</li>
<li>Manual/Autorange.</li>
<li>Relative measurements.</li>
<li>Internal memory.</li>
<li>Autotest for automatic detection of AC or DC parameters.</li>
<li>Auto backlight.</li>
<li>Auto Power Off.</li>
</ul>
<p><span style="font-size: large;">Included Accessories</span></p>
<ul>
<li>Protective rubber holster.</li>
<li>Test leads (red and black).</li>
</ul>
<p><img decoding="async" class="alignnone wp-image-1849" src="http://obiat.com.au/wp-content/uploads/2016/03/Yaamk0000ht0-300x169.jpg" alt="Yaamk0000ht0" width="101" height="57" srcset="https://obiat.com.au/wp-content/uploads/2016/03/Yaamk0000ht0-300x169.jpg 300w, https://obiat.com.au/wp-content/uploads/2016/03/Yaamk0000ht0.jpg 377w" sizes="(max-width: 101px) 100vw, 101px" /></p>
<ul>
<li>Belt with Magnetic end.</li>
</ul>
<p><img decoding="async" class="alignnone wp-image-1846" src="http://obiat.com.au/wp-content/uploads/2016/03/Magnetic-Hanger-300x169.jpg" alt="Magnetic Hanger" width="83" height="47" srcset="https://obiat.com.au/wp-content/uploads/2016/03/Magnetic-Hanger-300x169.jpg 300w, https://obiat.com.au/wp-content/uploads/2016/03/Magnetic-Hanger.jpg 377w" sizes="(max-width: 83px) 100vw, 83px" /></p>
<ul>
<li>Alligator clips</li>
</ul>
<p><img decoding="async" class="alignnone wp-image-1850" src="http://obiat.com.au/wp-content/uploads/2016/03/Yaamk0001ht0-300x169.jpg" alt="Yaamk0001ht0" width="80" height="45" srcset="https://obiat.com.au/wp-content/uploads/2016/03/Yaamk0001ht0-300x169.jpg 300w, https://obiat.com.au/wp-content/uploads/2016/03/Yaamk0001ht0.jpg 377w" sizes="(max-width: 80px) 100vw, 80px" /></p>
<ul>
<li>Batteries.</li>
<li>User manual.</li>
</ul>
<h3>Specifications</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">Specifications</td>
</tr>
<tr>
<td class="speccelltitle" width="275">DC Voltage range</td>
<td class="speccelldata">50.000mV &#8211; 1000.0V</td>
</tr>
<tr>
<td class="speccelltitle" width="275">AC TRMS Voltage range</td>
<td class="speccelldata">50.000mV &#8211; 1000.0V</td>
</tr>
<tr>
<td class="speccelltitle" width="275">DC Current range</td>
<td class="speccelldata">50.000mA &#8211; 1.0000A</td>
</tr>
<tr>
<td class="speccelltitle" width="275">AC TRMS Current range</td>
<td class="speccelldata">50.000mA &#8211; 1.0000A</td>
</tr>
<tr>
<td class="speccelltitle" width="275">Resistance range</td>
<td class="speccelldata">500.00Ω &#8211; 50.000MΩ</td>
</tr>
<tr>
<td class="speccelltitle" width="275">Continuity test range</td>
<td class="speccelldata">500.0Ω</td>
</tr>
<tr>
<td class="speccelltitle" width="275">Diode Test range</td>
<td class="speccelldata">2.000V</td>
</tr>
<tr>
<td class="speccelltitle" width="275">Frequency AC Voltage/Current range</td>
<td class="speccelldata">500.00Hz &#8211; 100.00kHz</td>
</tr>
<tr>
<td class="speccelltitle" width="275">Power supply</td>
<td class="speccelldata">4 x 1.5V alkaline batteries type AA IEC LR6</td>
</tr>
<tr>
<td class="speccelltitle" width="275">Sizes</td>
<td class="speccelldata">207(L)x95(W)x52(H) mm</td>
</tr>
<tr>
<td class="speccelltitle" width="275">Weight (included batteries)</td>
<td class="speccelldata">630g</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht8100-process-calibratormultimeter/">HT Italia HT8100 Process Calibrator/Multimeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht8100-process-calibratormultimeter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia HT401 Digital Multimeter, CAT IV-600V</title>
		<link>https://obiat.com.au/product/ht-italia-ht401-digital-multimeter-cat-iv-600v/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht401-digital-multimeter-cat-iv-600v/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 26 Feb 2016 22:50:38 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1009</guid>

					<description><![CDATA[<h3><span style="color: #0000ff;"><img class="alignnone size-full wp-image-974" src="http://obiat.com.au/wp-content/uploads/2016/02/HT-ITALIA-LOGO-1.png" alt="HT ITALIA LOGO" width="160" height="100" /></span></h3>
<p><strong><span style="color: #0000ff;">The New Industry Standard in Professional Multimeters.</span></strong></p>
<p>The HT Italia model HT401 is a TRMS digital multimeter designed to perform AC/DC voltage measurements up to 1000V, AC/DC current measurement up to 10A, resistance, continuity test, diode test, frequency, capacitance, and temperature with the supplied type K bead probe.</p>
<h2>Features</h2>
<p>•DC Voltage<br />
•AC and AC+DC TRMS Voltage<br />
•DC Current<br />
•AC and AC+DC TRMS Current<br />
•AC/DC voltage with low input impedance (Auto-V)<br />
•“Voltsense” for AC voltage detection without contact<br />
•Resistance<br />
•Continuity test<br />
•Diode test<br />
•Capacitance<br />
•Frequency<br />
•Temperature with type K probes<br />
•Data HOLD<br />
•MIN/MAX/PEAK<br />
•Manual/Autorange<br />
•Bargraph<br />
•Backlight<br />
•Fuse protection on inputs<br />
•Alarm indication to avoid wrong connections<br />
•Auto Power OFF</p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht401-digital-multimeter-cat-iv-600v/">HT Italia HT401 Digital Multimeter, CAT IV-600V</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div id="fbPhotoSnowliftTagApproval" class="fbPhotoTagApproval hidden_elem"><strong>The New Industry Standard in Professional Multimeters</strong>.</div>
<div class="fbPhotoTagApproval hidden_elem"></div>
<div class="fbPhotoTagApproval hidden_elem">The HT Italia model HT401is a TRMS digital multimeter designed to perform AC/DC voltage measurements up to 1000V, AC/DC current measurement up to 10A, resistance, continuity test, diode test, frequency, capacitance, and temperature with the supplied type K bead probe.<br />
It can measure combined AC+DC, which is usually only on much more expensi<span class="text_exposed_show">ve meters, and has a built in LoZ to minimise “Ghost” voltages when measuring AC.<br />
The meter is designed in compliance with IEC/EN 61010-1 safety standard with double insulation protection in CAT IV 600V and CAT III 1000V. HT401 has a backlit LCD display with bargraph. Other features are HOLD function, MAX/MIN/PEAK functions and Auto Power OFF feature is integrated to preserve the internal battery after 20 minutes of idleness. </span>Check the Spec! Check the Price!</div>
<div class="fbPhotoTagApproval hidden_elem">Similar to the Fluke 179.</div>
<div class="fbPhotoTagApproval hidden_elem">
<p><strong>Technical data</strong></p>
<table>
<tbody>
<tr>
<th>Interfaces</th>
<td>none</td>
</tr>
<tr>
<th>Weight</th>
<td>300 g</td>
</tr>
<tr>
<th>Voltage metering</th>
<td>AC/DC</td>
</tr>
<tr>
<th>Current reading</th>
<td>AC/DC</td>
</tr>
<tr>
<th>Height</th>
<td>200 mm</td>
</tr>
<tr>
<th>Width</th>
<td>80 mm</td>
</tr>
<tr>
<th>Type</th>
<td>HT401</td>
</tr>
<tr>
<th>DC resistance</th>
<td>10 MΩ</td>
</tr>
<tr>
<th>AC resistance</th>
<td>10 MΩ</td>
</tr>
<tr>
<th>A AC reading range (min.)</th>
<td>0.01 mA</td>
</tr>
<tr>
<th>Amperage reading range AC (max.)</th>
<td>10 A</td>
</tr>
<tr>
<th>Display (counts)</th>
<td>6000</td>
</tr>
<tr>
<th>A DC reading range (max.)</th>
<td>10 A</td>
</tr>
<tr>
<th>V AC reading range (max.)</th>
<td>1000 V</td>
</tr>
<tr>
<th>Basic accuracy</th>
<td>0.08 %</td>
</tr>
<tr>
<th>Reading category</th>
<td>CAT III 1000 V, CAT IV 600 V</td>
</tr>
<tr>
<th>Category</th>
<td>Handheld multimeter</td>
</tr>
<tr>
<th>V AC reading range (min.)</th>
<td>0.01 mV</td>
</tr>
<tr>
<th>Voltage reading range DC (min.)</th>
<td>0.01 mV</td>
</tr>
<tr>
<th>Amperage reading range DC (min.)</th>
<td>0.01 mA</td>
</tr>
<tr>
<th>Measurement type</th>
<td>True RMS</td>
</tr>
<tr>
<th>Calibrated to</th>
<td>Manufacturer standards</td>
</tr>
<tr>
<th>Voltage DC reading range (max.)</th>
<td>1000 V</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht401-digital-multimeter-cat-iv-600v/">HT Italia HT401 Digital Multimeter, CAT IV-600V</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht401-digital-multimeter-cat-iv-600v/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>