<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Phase Sequence Indicator Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/ht-italia/phase-sequence-indicator/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/ht-italia/phase-sequence-indicator/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Sun, 26 Sep 2021 01:42:59 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Phase Sequence Indicator Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/ht-italia/phase-sequence-indicator/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</title>
		<link>https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 09 May 2016 10:02:30 +0000</pubDate>
				<guid isPermaLink="false">http://rapid-tech.com.au/?post_type=product&#038;p=3342</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<div class="productDetails">
<div class="itemDesc">
<p id="pShortDesc"><strong>HT Italia HT9 Two pole voltage tester with Lamp test</strong></p>
</div>
</div>
<p class="block">In addition to DC/AC voltage measurement and continuity testing the HT Italia HT9 also offers gas-filled lamp tests and phase sequence/conformity detection features.</p>
<h4>HT Italia HT9 Features:</h4>
<ul>
<li>DC/AC voltage up to 690V</li>
<li>AC voltage detector with 1 wire method</li>
<li>Neon and fluorescent lamp test</li>
<li>Sodium/mercury vapor lamp test</li>
<li>Halogen lamp test</li>
<li>Non-electronic ballast test</li>
<li>Continuity test</li>
<li>Phase sequence test</li>
<li>Diode test</li>
<li>LED and acoustic indications</li>
<li>Built-in torch</li>
<li>LCD display</li>
<li>Safety: IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61243-3:2010</li>
<li>Measurement category: CAT III 690V, CAT IV 600V</li>
</ul>
<h5><strong>Authorised Australian Distributor</strong></h5>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" /><strong>   <a href="http://obiat.com.au/wp-content/uploads/2016/05/HT-9-8-6.pdf" target="_blank">HT9-8-6 Brochure</a></strong></p>
<p><strong><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a href="http://obiat.com.au/wp-content/uploads/2016/05/HT9-8-6-User-Manual.pdf" target="_blank">HT9-8-6 User Manual</a></strong></p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/">HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>To overcome difficult pinpointing of the right cable within a frame on a switchboard under poor light conditions, a built-in white LED flashlight makes testing possible and easy even in dark environments. The slim and ergonomic design of HT Italia HT9 is highly appreciated by contracting electricians, field professionals, troubleshooters as well as any kind of user.</p>
<p>Designed according to the requirements of field professionals, HT Italia HT9 is must-have troubleshooting tool.</p>
<p><b>Two pole voltage meter with Lamp Test. With built-in gas-filled lamp tester and non-contact phase sequence/conformity tester</b></p>
<p><img fetchpriority="high" decoding="async" class="alignnone wp-image-3344" src="http://obiat.com.au/wp-content/uploads/2016/05/HT9_small3.jpg" alt="HT9_small3" width="273" height="220" /></p>
<p>Digital two pole voltage tester HT Italia HT9 provides daily use features. In addition to DC/AC voltage measurement and continuity test, HT9 also offers gas-filled lamp test and phase sequence/conformity detection features. To overcome difficult pinpointing of the right cable within a frame on a switchboard under poor light conditions, a built-in white LED flashlight makes testing possible and easy even in dark environments. The slim and ergonomic design of HT9 is highly appreciated by contracting electricians, field professionals, troubleshooters as well as any vkind of user. Designed according to the requirements of field professionals, HT9 is must-have troubleshooting tool.</p>
<table class="spectable" style="height: 226px;" border="0" width="560" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr>
<td class="speccellcategory" colspan="3" align="center"><strong>Figure 2 &#8211; HT Italia HT9 LED and Display Description</strong></td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>1.</strong></td>
<td class="speccelldata">Voltage indication leds</td>
<td class="speccelldata" rowspan="9" align="center"> <img decoding="async" class="alignnone size-full wp-image-3343" src="http://obiat.com.au/wp-content/uploads/2016/05/HT9-LED-Display.jpg" alt="HT9 LED Display" width="238" height="290" /></td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>2.</strong></td>
<td class="speccelldata">Buzzer hole for acoustic signal</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>3.</strong></td>
<td class="speccelldata">Indication led Lamp test</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>4.</strong></td>
<td class="speccelldata">Indication led Phase sequence</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>5.</strong></td>
<td class="speccelldata">Indication led Phase detection / Dangerous voltage</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>6.</strong></td>
<td class="speccelldata">Indication led Continuity test</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>7.</strong></td>
<td class="speccelldata">Indication led 12V and positive or negative polarity</td>
</tr>
<tr>
<td class="speccelltitle" align="center" width="50"><strong>8.</strong></td>
<td class="speccelldata">LCD display with voltage, polarity and flat battery indic</td>
</tr>
</tbody>
</table>
<table border="0" width="95%" cellspacing="5" cellpadding="5" align="center">
<tbody>
<tr>
<td valign="top">The HT Italia HT9 can also be used to check reactors, starters,<br />
capacitors and resistors, further to the following kinds of lamps:</p>
<ul>
<li>Fluorescent lamps</li>
<li>Low-pressure sodium lamps</li>
<li>High-pressure sodium lamps</li>
<li>Neon tubes</li>
<li>Mercury-vapour lamps and halogen lamps</li>
</ul>
</td>
<td valign="top"><b>Standards</b></p>
<ul>
<li>EMC 2004/108/CE Directive</li>
<li>CE MARK</li>
<li>IEC/EN 61010-1</li>
<li>IEC/EN61010-2-030</li>
<li>IEC/EN61243-3:2010</li>
<li>LVD 2006/95/CE Directive</li>
</ul>
</td>
</tr>
</tbody>
</table>
<h3>HT Italia HT9 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellheader" colspan="2">TECHNICAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccelldata" colspan="2"><small>Accuracy indicated as: ±[%rdg + (num. dgt * resolution)] at 23°C ± 5°C, &lt;70%HR</small></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">AC/DC VOLTAGE MEASUREMENT</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range [V]</td>
<td class="speccelldata">12.0 &#8211; 299.9<br />
300 &#8211; 690</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Resolution [V]</td>
<td class="speccelldata">0.1<br />
1</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">16 &#8211; 400</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Accuracy</td>
<td class="speccelldata">+/-(3%rdg + 5dgt)</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Overload protection</td>
<td class="speccelldata">690VDC/AC</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">AC VOLTAGE WITH 1 WIRE</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range [V]</td>
<td class="speccelldata">100 &#8211; 690</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">50 &#8211; 60</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement method</td>
<td class="speccelldata">1-wire with contact on metal live parts</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Overload protection</td>
<td class="speccelldata">690VAC</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">PHASE SEQUENCE INDICATION</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Voltage range [V]</td>
<td class="speccelldata">120 &#8211; 400 (Phase – Earth)</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Frequency range [Hz]</td>
<td class="speccelldata">50 &#8211; 60</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement method</td>
<td class="speccelldata">2-wires with contact on metal live parts</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">LAMP TEST</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Voltage with new battery</td>
<td class="speccelldata">Approx 3kV / 240kHz</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Field intensity (200-280kHz)</td>
<td class="speccelldata">Approx 100µV/m</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Indications</td>
<td class="speccelldata">LED blinking</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">CONTINUITY TEST</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Range</td>
<td class="speccelldata">0 &#8211; 500KΩ + 50%</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Test current</td>
<td class="speccelldata">&lt;7µA</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Indications</td>
<td class="speccelldata">LED + acoustic signal</td>
</tr>
<tr>
<td class="speccellheader" colspan="2">GENERAL SPECIFICATIONS</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Mechanical specifications</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Dimensions (L x W x H)</td>
<td class="speccelldata">255 x 60 x 35mm</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Weight (included batteries)</td>
<td class="speccelldata">170g</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Encapsulation</td>
<td class="speccelldata">IP64</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Display</td>
<td class="speccelldata">LED, LCD</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Power supply</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Internal supply</td>
<td class="speccelldata">2&#215;1.5V alkaline batteries type AAA, IEC LR03</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Reference guidelines</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Safety</td>
<td class="speccelldata">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61243-3:2010</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Measurement category</td>
<td class="speccelldata">CAT III 690V; CAT IV 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Max height of use</td>
<td class="speccelldata">2000m</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Environmental conditions</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Reference temperature</td>
<td class="speccelldata">23°C ± 5°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working temperature</td>
<td class="speccelldata">-15 to 55°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Working humidity</td>
<td class="speccelldata">&lt;85%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Storage temperature</td>
<td class="speccelldata">-20 to 70°C</td>
</tr>
<tr>
<td class="speccelltitle" width="“200”">Storage humidity</td>
<td class="speccelldata">&lt;85%HR</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/">HT Italia HT9 Two-pole CAT IV  Voltage Tester with Lamp Test</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht9-pen-type-digital-multimeter-lamp-test/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT ITALIA HT82  Portable Digital Phase Sequence Indicator</title>
		<link>https://obiat.com.au/product/ht-italia-ht82/</link>
					<comments>https://obiat.com.au/product/ht-italia-ht82/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 17 Mar 2016 03:56:53 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1751</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1537" src="http://obiat.com.au/wp-content/uploads/2016/02/HT_Italia_Ca.jpg" alt="HT_Italia_Ca" width="73" height="89" /></p>
<p>Portable digital phase sequence indicator. HT Italia HT82 model is a digital portable meter to perform the phase sequence indication measurement by connecting the standard test leads on L1, L2 and L3 phases of a generic three phase system. The meter shows the “R” indication in positive test and “L” indication in the opposite case. An acknowledgement of wrong cable connection it’s also detectable by meter.</p>
<p><img class="alignnone size-full wp-image-1739" src="http://obiat.com.au/wp-content/uploads/2016/03/Warranty-4.jpg" alt="Warranty 4" width="149" height="41" /></p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht82/">HT ITALIA HT82  Portable Digital Phase Sequence Indicator</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="col_full content_list">
<div class="promo">
<div class="promo-desc">
<h3>HT ITALIA HT82 Functions:</h3>
</div>
</div>
<ul>
<li>AC voltage functional range from 40V to 690V</li>
<li>Frequency functional range from 15Hz to 400Hz</li>
<li>&#8216;R&#8217; and &#8216;L&#8217; indication at display</li>
<li>Detectable of wrong connection</li>
<li>LCD custom display</li>
<li>Protection holster</li>
<li>Safety: IEC/EN61010-1, CAT III 600V</li>
</ul>
</div>
<p><a name="96082"></a></p>
<div class="col_full content_list">
<div class="promo">
<div class="promo-desc">
<h2>Accessories</h2>
</div>
</div>
<div class="entry_share clearfix"><strong>Standard</strong></div>
<ul>
<li>3 test cables + 3 alligator clips</li>
</ul>
<p><img decoding="async" class="alignnone wp-image-1752" src="http://obiat.com.au/wp-content/uploads/2016/03/kit82.jpg__377x213_q85_crop_subsampling-2_upscale-300x169.jpg" alt="kit82.jpg__377x213_q85_crop_subsampling-2_upscale" width="144" height="81" srcset="https://obiat.com.au/wp-content/uploads/2016/03/kit82.jpg__377x213_q85_crop_subsampling-2_upscale-300x169.jpg 300w, https://obiat.com.au/wp-content/uploads/2016/03/kit82.jpg__377x213_q85_crop_subsampling-2_upscale.jpg 377w" sizes="(max-width: 144px) 100vw, 144px" /></p>
<ul>
<li>Carrying case</li>
<li>User manual</li>
</ul>
<h3>Specifications</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide"><center></p>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">PHASE SEQUENCE INDICATION</td>
</tr>
<tr>
<td class="speccelltitle" width="195">AC Voltage functional range</td>
<td class="speccelldata">40V &#8211; 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Frequency functional range</td>
<td class="speccelldata">15Hz &#8211; 400Hz</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Mechanical specification</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Dimensions</td>
<td class="speccelldata">130(L) x 69(W) x 22(H)mm</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Weight (included battery)</td>
<td class="speccelldata">130g</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Power supply</td>
</tr>
<tr>
<td class="speccelltitle" width="195">External power supply</td>
<td class="speccelldata">directly from electrical network</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Measurement method</td>
<td class="speccelldata">3-wires</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Display</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Features</td>
<td class="speccelldata">Custom, LCD, with “R” or “L” phase sequence indication</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Standards and safety</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Safety</td>
<td class="speccelldata">IEC/EN61010-1</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Insulation</td>
<td class="speccelldata">double insulation</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Pollution degree</td>
<td class="speccelldata">2</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Overvoltage category</td>
<td class="speccelldata">CAT III 600V</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Max altitude</td>
<td class="speccelldata">2000m</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Environmental conditions</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Reference temperature</td>
<td class="speccelldata">23° ± 5°C</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Working temperature</td>
<td class="speccelldata">5 &#8211; 40 °C</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Working humidity</td>
<td class="speccelldata">&lt;80%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Storage temperature</td>
<td class="speccelldata">-10 &#8211; 60 °C</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Storage humidity</td>
<td class="speccelldata">&lt;70%HR</td>
</tr>
<tr>
<td class="speccelltitle" width="195">Max altitude</td>
<td class="speccelldata">2000m</td>
</tr>
</tbody>
</table>
<p></center></div>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-ht82/">HT ITALIA HT82  Portable Digital Phase Sequence Indicator</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-ht82/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
