<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Earth/Ground Testers Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/kyoritsu/earthground-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/kyoritsu/earthground-testers/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Mon, 17 Sep 2018 03:01:22 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Earth/Ground Testers Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/kyoritsu/earthground-testers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Kyoritsu 4106 Earth &#038; Ground Resistance Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-4106-earth-ground-resistance-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 17 Sep 2018 02:56:45 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=17341</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>Kyoritsu 4106 is a 2/ 3/ 4-wire digital earth resistance/earth resistivity tester, equipped with a microcomputer, for measuring earth resistances and calculating earth resistivities.<br />
It has an output voltage of 10 Vrms or lower. This makes it an instrument of choice for measuring earth resistances on installations ranging from in-house wiring systems and electrical appliances to power distribution lines.<br />
Sub-results that can be shown on the display include resistance of the auxiliary earth spikes, frequency of test current, voltage and frequency of interference (noise) and residual resistance Rk.</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-4106-Datasheet.pdf" rel="noopener">Kyoritsu-4106-Datasheet</a></span></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-4106-User-Manual.pdf" rel="noopener">Kyoritsu-4106-User-Manual</a></span></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-4106-earth-ground-resistance-tester/">Kyoritsu 4106 Earth &#038; Ground Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="headLine5">Kyoritsu 4106 Earth &amp; Ground Resistance Tester</h3>
<p>• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.<br />
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.<br />
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.<br />
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.<br />
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.<br />
• Large Graphic Display with backlight for readings in poorly illuminated areas.<br />
• Up to 800 measurement results can be saved in the memory and recalled on the display.<br />
• The stored results can be transferred to a PC using the &#8220;KEW Report&#8221; software and a USB adaptor (Model 8212-USB) which are included.<br />
• Robust design with IP54 protection.</p>
<h3 style="text-align: center;">Earth Resistance Measurements with 4, 3 and 2 Wires</h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel.jpg"><img fetchpriority="high" decoding="async" class="size-full wp-image-6332 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel.jpg" alt="" width="983" height="244" /></a></p>
<h3>Kyoritsu 4106 Earth &amp; Ground Resistance Tester Specifications:</h3>
<div class="editor">
<div class="tableScroller">
<table>
<tbody>
<tr>
<th><span style="font-size: 85%;">Function</span></th>
<th><span style="font-size: 85%;">Range</span></th>
<th><span style="font-size: 85%;">Resolution</span></th>
<th><span style="font-size: 85%;">Measuring range</span></th>
<th><span style="font-size: 85%;">Accuracy</span></th>
</tr>
<tr>
<th rowspan="6"><span style="font-size: 85%;">Earth resistance</span><br />
<span style="font-size: 85%;">Re</span><br />
<span style="font-size: 85%;">(Rg at</span><br />
<span style="font-size: 85%;">ρ measurement)</span></th>
<td><span style="font-size: 85%;">2Ω</span></td>
<td><span style="font-size: 85%;">0.001Ω</span></td>
<td><span style="font-size: 85%;">0.03 &#8211; 2.099Ω</span></td>
<td><span style="font-size: 85%;">±2%rdg±0.03Ω</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">20Ω</span></td>
<td><span style="font-size: 85%;">0.01Ω</span></td>
<td><span style="font-size: 85%;">0.03 &#8211; 20.99Ω</span></td>
<td rowspan="5"><span style="font-size: 85%;">±2%rdg±5dgt (*1)</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">200Ω</span></td>
<td><span style="font-size: 85%;">0.1Ω</span></td>
<td><span style="font-size: 85%;">0.3 &#8211; 209.9Ω</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">2000Ω</span></td>
<td><span style="font-size: 85%;">1Ω</span></td>
<td><span style="font-size: 85%;">3 &#8211; 2099Ω</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">20kΩ</span></td>
<td><span style="font-size: 85%;">10Ω</span></td>
<td><span style="font-size: 85%;">0.03k &#8211; 20.99kΩ</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">200kΩ</span></td>
<td><span style="font-size: 85%;">100Ω</span></td>
<td><span style="font-size: 85%;">0.3k &#8211; 209.9kΩ</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Auxiliary earth resistance</span><br />
<span style="font-size: 85%;">Rh, Rs</span></th>
<td></td>
<td></td>
<td></td>
<td><span style="font-size: 85%;">8% of Re+Rh+Rs</span></td>
</tr>
<tr>
<th rowspan="6"><span style="font-size: 85%;">Earth resistivity</span><br />
<span style="font-size: 85%;">ρ</span></th>
<td><span style="font-size: 85%;">2Ω</span></td>
<td rowspan="6"><span style="font-size: 85%;">0.1Ω·mm &#8211; 1Ω·m</span><br />
<span style="font-size: 85%;">Autoranging</span></td>
<td><span style="font-size: 85%;">0.2 &#8211; 395.6Ω·m</span></td>
<td rowspan="6"><span style="font-size: 85%;">ρ=2×π×a×Rg (*2)</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">20Ω</span></td>
<td><span style="font-size: 85%;">0.2 &#8211; 3956Ω·m</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">200Ω</span></td>
<td><span style="font-size: 85%;">20 &#8211; 39.56kΩ·m</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">2000Ω</span></td>
<td><span style="font-size: 85%;">0.2 &#8211; 395.6kΩ·m</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">20kΩ</span></td>
<td rowspan="2"><span style="font-size: 85%;">2.0 &#8211; 1999kΩ·m</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">200kΩ</span></td>
</tr>
<tr>
<th rowspan="2"><span style="font-size: 85%;">Series interference voltage</span><br />
<span style="font-size: 85%;">Ust (A.C only) (*3)</span></th>
<td rowspan="2"><span style="font-size: 85%;">50V</span></td>
<td rowspan="2"><span style="font-size: 85%;">0.1V</span></td>
<td rowspan="2"><span style="font-size: 85%;">0 &#8211; 50.9Vrms</span></td>
<td><span style="font-size: 85%;">±2%rdg±2dgt (50/60Hz)</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">±3%rdg±2dgt (40 &#8211; 500Hz)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Frequency</span><br />
<span style="font-size: 85%;">Fst</span></th>
<td><span style="font-size: 85%;">Autoranging</span></td>
<td><span style="font-size: 85%;">0.1Hz</span><br />
<span style="font-size: 85%;">1Hz</span></td>
<td><span style="font-size: 85%;">40Hz &#8211; 500Hz</span></td>
<td><span style="font-size: 85%;">±1%rdg±2dgt</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Measuring method</span></th>
<td colspan="4"><span style="font-size: 85%;">Earth resistance: Fall-of-potential method</span><br />
<span style="font-size: 85%;">(currents and voltages measured via the Probes)</span><br />
<span style="font-size: 85%;">Measurement method of Earth Resistivity (ρ): Wenner 4-pole method</span><br />
<span style="font-size: 85%;">Series interference voltage (earth voltage)</span><br />
<span style="font-size: 85%;">RMS Rectifier (between the E-S Terminals)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Memory capacity</span></th>
<td colspan="4"><span style="font-size: 85%;">800 data</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Communication Interface</span></th>
<td colspan="4"><span style="font-size: 85%;">Model 8212-USB Optical Adaptor</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">LCD</span></th>
<td colspan="4"><span style="font-size: 85%;">Dot-matrix 192×64 monochrome</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Over-range Indication</span></th>
<td colspan="4"><span style="font-size: 85%;">&#8220;OL&#8221;</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Overload Protection</span></th>
<td colspan="4"><span style="font-size: 85%;">between E-S(P) and between E-H(C) terminals AC280V / 10 sec.</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Applicable standards</span></th>
<td colspan="4"><span style="font-size: 85%;">IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2</span><br />
<span style="font-size: 85%;">IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Power source</span></th>
<td colspan="4"><span style="font-size: 85%;">DC12V : sizeAA manganese dry battery (R6) × 8</span><br />
<span style="font-size: 85%;">(Auto power off: approx. 5 minutes)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Dimensions</span></th>
<td colspan="4"><span style="font-size: 85%;">167(L) × 185(W) × 89(D) mm</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Weight</span></th>
<td colspan="4"><span style="font-size: 85%;">approx. 900g (including batteries)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Accessories</span></th>
<td colspan="4"><span style="font-size: 85%;">7229A (Earth precision measurement),</span><br />
<span style="font-size: 85%;">7238A (Simplified measurement test leads),</span><br />
<span style="font-size: 85%;">8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),</span><br />
<span style="font-size: 85%;">8200-04 (Cord reel [4 pcs])×1 set,</span><br />
<span style="font-size: 85%;">8212-USB (USB adaptor with &#8220;KEW Report(Software)&#8221;),</span><br />
<span style="font-size: 85%;">9121 (Shoulder strap),</span><br />
<span style="font-size: 85%;">9125 (Carrying case),</span><br />
<span style="font-size: 85%;">R6 × 8, Instruction manual, Calibration certificate</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Optional</span></th>
<td colspan="4"><span style="font-size: 85%;">8212-RS232C (RS232C adaptor with &#8220;KEW Report(Software)&#8221;)</span></td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10"></section>
<div class="editor">
<p><span style="font-size: 85%;">(*1) Auxiliary earth resistance is 100Ω with Rk correction</span><br />
<span style="font-size: 85%;">(*2) Depending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0 &#8211; 30.0m</span><br />
<span style="font-size: 85%;">(*3) This instrument is NOT designed to measure line voltages on commercial powers.</span></p>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-4106-earth-ground-resistance-tester/">Kyoritsu 4106 Earth &#038; Ground Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>