<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Kyoritsu Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/kyoritsu/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/kyoritsu/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Mon, 01 Jul 2024 07:34:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Kyoritsu Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/kyoritsu/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Kyoritsu 6516 Multi Function Electrical Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-6516-multi-function-electrical-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 07 Oct 2020 03:30:16 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=60168</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2015/12/Kyoritsu_Logo_main.gif"><img class="alignnone size-full wp-image-27" src="https://obiat.com.au/wp-content/uploads/2015/12/Kyoritsu_Logo_main.gif" alt="" width="146" height="25" /></a></p>
<p>The KYORITSU 6516 &#38; 6516BT Multi-Function electrical testers have eight test functions in the one instrument.</p>
<ul>
<li>Continuity test</li>
<li>Insulation resistance test</li>
<li>Loop impedance test (High current measurement, No trip (ATT) measurement) 4 Prospective short circuit current test (On Loop impedance function)</li>
<li>RCD test</li>
<li>Voltage test</li>
<li>Phase rotation test 8 Earth test</li>
</ul>
<p>The Kyoritsu 6516 tester incorporates Anti Trip Technology (ATT) which electronically bypasses RCDs when performing loop impedance tests. This saves time and money by not having to take the RCD out of the circuit during testing and is a safer procedure to follow.</p>
<p>With the ATT function enabled, a test of 15mA or less is applied between line &#38; earth. It enables loop impedance measurements without tripping RCDs rated at 30mA and above.</p>
<p>ATT supports measurements using three wires: Line, Earth, and Neutral and also two wires: Line and Earth.</p>
<h3><strong>Also available is the <span style="text-decoration: underline;">Kyoritsu 6516BT with Bluetooth</span></strong></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-Datasheet.pdf" rel="noopener">Kyoritsu 6516-6516BT Datasheet</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-User-Manual.pdf" rel="noopener">Kyoritsu 6516-6516BT User Manual</a></span></h3>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-6516-multi-function-electrical-tester/">Kyoritsu 6516 Multi Function Electrical Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 6516 Multi Function Electrical Tester Features</h3>
<table style="height: 493px;" width="701">
<tbody>
<tr>
<td width="64"><strong><span style="font-size: 90%;">DISPLAY </span></strong></td>
<td width="571"><span style="font-size: 90%;">・Color LCD 3.5 inches dot matrix.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">ATT </span></strong></td>
<td><span style="font-size: 90%;">・Anti-Trip Technology (with 2 &amp; 3 wire) for no trip LOOP L-PE testing on all RCDs.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">LOOP </span></strong></td>
<td><span style="font-size: 90%;">・High test current range of 2Ω with 0.001Ω resolution.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・Zs Limit compares the values required by Electrical Installations Standard with measured results.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">RCD  </span></strong></td>
<td><span style="font-size: 90%;">・Type AC, A, F, B(General &amp; Selective), EV and Variable RCDs.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・Single and Auto test, Ramp test and Contact voltage.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">EARTH</span></strong></td>
<td><span style="font-size: 90%;">・Earth resistance test 2 and 3 wires with all accessories included.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">INSULATION </span></strong></td>
<td><span style="font-size: 90%;">・Resistance test 100, 250, 500 &amp; 1000V with auto discharge voltage.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">CONTINUITY</span></strong></td>
<td><span style="font-size: 90%;">・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">PHASE ROTATION </span></strong></td>
<td><span style="font-size: 90%;">・On 3-phase lines with clear indication of the sequence on the display.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">VOLTS </span></strong></td>
<td><span style="font-size: 90%;">・TRMS Voltage measurements 2-600V, Mains Frequency.</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;"><strong>HELP</strong>  </span></td>
<td><span style="font-size: 90%;">・Display shows how to connect the instrument according to the function selected.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">SPD  </span></strong></td>
<td><span style="font-size: 90%;"> ・Surge Protection Device test, for SPD that uses varistor.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">PAT </span></strong></td>
<td><span style="font-size: 90%;">・Portable Appliance Tester function, for Insulation &amp; Protective conductor resistance test</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;"><strong>SAFETY </strong>  </span></td>
<td><span style="font-size: 90%;">・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,</span></td>
</tr>
</tbody>
</table>
<h3><a></a>Bluetooth communication</h3>
<p>Kyoritsu 6516BT has a Bluetooth communication function and can exchange data with Android/ iOS tablet devices.</p>
<p>Before starting to use this function, download the special application &#8220;KEW Smart *&#8221; via the internet.</p>
<h4 class="tm4">Large LCD &amp; HELP function</h4>
<ul>
<li>All the test data is shown in one large colored screen.</li>
<li>HELP function will show how to connect the instrument according to the function selected</li>
</ul>
<div class="row"  id="row-1337950579">

	<div id="col-1995884258" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img fetchpriority="high" decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516_HELP.png" alt="" width="350" height="260" /></p>
		</div>
					</div>

	

	<div id="col-213913929" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516%20Large%20LCD.png" alt="" width="261" height="256" /></p>
		</div>
					</div>

	
</div>
<h4 class="tm4">Operation in 3 simple steps &amp; Hands free testing</h4>
<ol>
<li>Set the rotary dial to your testing range.</li>
<li>Connect the instrument to the installation under test.</li>
<li>Press the test button.(By remote probe or using the Lockdown function of the test button.)</li>
</ol>
<div class="row"  id="row-1960549163">

	<div id="col-270493877" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516_123step.png" width="600" height="261" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">Anti-Trip Technology (with 2 &amp; 3 wire)</h4>
<p>For no trip LOOP L-PE testing on all RCDs.<br />
With 3 wire (L, N, PE), to get the best accuracy readings.<br />
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).</p>
<p>Loop Impedance 0.001 resolution</p>
<p>High test current range of 2Ω with 0.001Ω resolution.</p>
<p>Zs/Ra Limit</p>
<p>Zs Limit compares the values required by Electrical Installations Standard with measured results.</p>
<p>The verification of safety requirement on an electrical installation is simplified by using Zs/Ra Limit function. This function will automatically check if the measured loop impedance for TN (or earth loop for TT) is low enough to trip (disconnect) the MCB / Fuse / RCD giving the result of PASS or FAIL on the display.</p>
<div class="row"  id="row-1347886202">

	<div id="col-1621331750" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_0001.png" width="250" height="186" align="right" /></p>
		</div>
					</div>

	

	<div id="col-1593744975" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="alignright" src="https://www.kew-ltd.co.jp/files/en/img/6516_Zs%20table.png" width="260" height="171" align="right" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">SPD test</h4>
<p>SPD (Surge Protection Device) which contains varistor can be tested measuring the tripping voltage without damage it.<br />
<div class="row"  id="row-2142463977">

	<div id="col-959637214" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_SPD.png" width="250" height="174" align="right" /></p>
		</div>
					</div>

	
</div>
<h5></h5>
<h5></h5>
<p>&nbsp;</p>
<h5></h5>
<h5></h5>
<h4 class="tm4">PAT test</h4>
<p>PAT test (PAT = Portable Appliance Tester) It is possible to check the insulation resistance and earth bond continuity of portable appliances for class I and II.</p>
<div class="row"  id="row-1198209394">

	<div id="col-1125514402" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_PAT.1png.png" width="300" height="253" align="right" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">Connectivity</h4>
<p><strong>Use the PC application KEW Report to improve work efficiency.</strong></p>
<p>KYORITSU 6516 can download the test data by connecting the USB adaptor (Model 8212-USB) and then print complete Test Reports by a PC.<div class="row"  id="row-1545808755">

	<div id="col-693378348" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<p><img decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_PC.png" width="300" height="216" align="right" /></p>
<p><img decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/6516BT_PC1.png" width="350" height="134" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-6516-multi-function-electrical-tester/">Kyoritsu 6516 Multi Function Electrical Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KYORITSU 2413R Leakage Clamp Meter / 1000A</title>
		<link>https://obiat.com.au/product/kyoritsu-2413r-leakage-clamp-meter-1000a/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 24 Feb 2019 23:44:04 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=28568</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu 2413R is 1000A True RMS AC clampmeter, that is also able to measure leakage current. It has extra wide 68mm opening jaws which provides it with the ability to clamp on all three or four phase wires to measure the total leakage current measurement.</p>
<p>The Kyoritsu 2413R has five scales (200mA/2/20/200A/1000A) and features a frequency selector switch to eliminate the effect of harmonics, providing a more accurate measurement, particularly at the lower end of the current scale.</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/02/Kyoritsu-2413R-User-Manual.pdf" rel="noopener">Kyoritsu 2413R User Manual</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2413r-leakage-clamp-meter-1000a/">KYORITSU 2413R Leakage Clamp Meter / 1000A</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="font-size: 110%;">The KYORITSU 2413R Leakage Clamp Meter features:</span></h4>
<p style="padding-left: 30px;">• Large transformer jaws of 68mm diameter<br />
• Able to clamp on all three or four wires (3 phases) together for leakage current measurement.<br />
• True RMS enables an accurate measurement for distorted waveforms.<br />
• Measurement from mA up to AC 1000A<br />
• Frequency filter switch to eliminate the effect of the harmonics.<br />
• 2 way analogue output terminal<br />
• Resolution 0.1mA<br />
<span style="color: #333333; font-size: 14.4px;">• Data-hold function.<br />
• </span>Peak-hold function.<br />
<span style="color: #333333; font-size: 14.4px;">• </span>Minimises the effects of stray magnetic fields.<br />
<span style="color: #333333; font-size: 14.4px;">• </span>Rotary switch for easy one finger operation.<br />
<span style="color: #333333; font-size: 14.4px;">• </span>LCD screen with backlight.</p>
<h4><span style="font-size: 110%;">Using the Kyoritsu 2413R Leakage Clamp Meter </span></h4>
<p><img decoding="async" class="alignnone size-full wp-image-9922 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-2413R-in-use.jpg" alt="" width="590" height="557" /></p>
<h4><span style="font-size: 110%;">KYORITSU 2413R Leakage Clamp Meter Specifications:</span></h4>
<table class="specTable mb0">
<tbody>
<tr>
<th>AC A (50/60Hz)</th>
<td>200mA/2/20/200/1000A<br />
±2.5%rdg±5dgt (200mA/2/20A)<br />
±3.0%rdg±5dgt (200A, 0 &#8211; 500A)<br />
±5.5%rdg (501 &#8211; 1000A)</td>
</tr>
<tr>
<th>AC A (WIDE)</th>
<td>200mA/2/20/200/1000A<br />
±1.8%rdg±5dgt (50/60Hz) (200mA/2/20A)<br />
±2.0%rdg±5dgt (50/60Hz) (200A, 0 &#8211; 500A)<br />
±5.0%rdg (50/60Hz) (501 &#8211; 1000A)</td>
</tr>
<tr>
<th>Crest factor</th>
<td>3.0 or less</td>
</tr>
<tr>
<th>Conductor size</th>
<td>Ø68mm max.</td>
</tr>
<tr>
<th>Frequency response</th>
<td>40Hz &#8211; 1kHz</td>
</tr>
<tr>
<th>Output</th>
<td>Waveform :<br />
AC200mV against the maximum value of each range (1000A range is 100mV)<br />
Recorder :<br />
DC200mV against the maximum value of each range (1000A range is 100mV)</td>
</tr>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT III 300V Pollution degree 2<br />
IEC 61010-2-032</td>
</tr>
<tr>
<th>Power source</th>
<td>6F22 (9V) × 1 *Continuous measuring time: Approx. 60 hours</td>
</tr>
<tr>
<th>Dimensions</th>
<td>250(L) × 130(W) × 50(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>Approx. 570g (including battery)</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>9094 (Carrying Case)<br />
6F22 × 1<br />
Instruction Manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7073 (2 WAY Output Cord)</td>
</tr>
</tbody>
</table>
<h4><span style="font-size: 110%;">Using the AC &amp; DC Output Connector of the KYORITSU 2413R</span></h4>
<p><img decoding="async" class="alignnone size-full wp-image-9923 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2019/02/Kyoritsu-2413R-output.jpg" alt="Using the Output function of the KEW 2413R Leakage Clamp Meter" width="570" height="508" /></p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2413r-leakage-clamp-meter-1000a/">KYORITSU 2413R Leakage Clamp Meter / 1000A</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KYORITSU 3023A Digital Insulation &#038; Continuity Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-3023a-digital-insulation-continuity-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 19 Feb 2019 06:32:07 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=28103</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu 3023A is the ideal insulation tester for any electrician. It's Digital Display allows better accuracy, easier reading of results and faster testing. It is the perfect instrument if you are upgrading from an analogue insulation tester.</p>
<h4>Main Features:</h4>
<p>• 100/250/500/1000V Test Voltages<br />
• Fast response and quick insulation test. (1 second result display)<br />
• Three functions in one unit, insulation test with 4 voltage ranges, continuity test, AC voltage measurement<br />
• 200mA measuring current on continuity testing</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 105%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/02/Kyoritsu-3023A-Datasheet.pdf" rel="noopener">Kyoritsu 3023A Datasheet</a></span></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 105%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/02/Kyoritsu-3023A-User-Manual.pdf" rel="noopener">Kyoritsu 3023A User Manual</a></span></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-3023a-digital-insulation-continuity-tester/">KYORITSU 3023A Digital Insulation &#038; Continuity Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<section class="mb10">
<h4>KYORITSU 3023A Digital Insulation &amp; Continuity Tester</h4>
<p>KYORITSU 3023A is a 4-range digital insulation resistance tester with 100/250/500/1000V Test Voltages. The 100V range is suitable for the testing of telecommunication cables. Resistance measurement with audible Continuity check function are also available.</p>
<h4>KYORITSU 3023A Features:</h4>
<p>• Fast response and quick insulation test.<br />
• Fast Result Display in one second<br />
• 100/250/500/1000V Test Voltages<br />
• Three functions in one unit, insulation test with 4 voltage ranges, continuity test, AC voltage measurement<br />
• 200mA measuring current on continuity testing<br />
• Comparator function with PASS / FAIL and buzzer<br />
• 0Ω adjustment at continuity measuring range<br />
• Memory function up to 99 data<br />
• Backlight LCD provides easy reading in dark locations<br />
• Safety lock system prevents an erroneous operation on 500 and 1000 Volt ranges<br />
• Safety standard IEC 61010-01 CAT III 600V</p>
<h4>KYORITSU 3023A Specifications:</h4>
<h4 class="headLine4 mb10">Insulation resistance</h4>
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Test voltage</th>
<td>100/250/500/1000V</td>
</tr>
<tr>
<th>Measuring range<br />
(Auto range)</th>
<td>4.000/40.00/200.0MΩ (100V)<br />
4.000/40.00/400.0/2000MΩ (250/500/1000V)</td>
</tr>
<tr>
<th>Mid-scale value</th>
<td>5MΩ (100/250V)<br />
50MΩ (500/1000V)</td>
</tr>
<tr>
<th>First effective measuring range</th>
<td>0.2 &#8211; 20MΩ (100V)<br />
0.2 &#8211; 40MΩ (250V)<br />
0.2 &#8211; 200MΩ (500V)<br />
0.2 &#8211; 1000MΩ (1000V)</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±2%rdg±6dgt</td>
</tr>
<tr>
<th>Second effective measuring range lower</th>
<td>0.110 &#8211; 0.199MΩ</td>
</tr>
<tr>
<th>Second effective measuring range upper</th>
<td>20.01 &#8211; 200.0MΩ (100V)<br />
40.01 &#8211; 2000MΩ (250V)<br />
200.1 &#8211; 2000MΩ (500V)<br />
1001 &#8211; 2000MΩ (1000V)</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±5%rdg±6dgt</td>
</tr>
<tr>
<th>Rated current</th>
<td>DC 1 &#8211; 1.2mA</td>
</tr>
<tr>
<th>Output short circuit current</th>
<td>1.5mA max</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="mb10">
<h4 class="headLine4 mb10">Ω/Continuity</h4>
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Auto range</th>
<td>40.00/400.0Ω</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±2%rdg±8dgt</td>
</tr>
<tr>
<th>Output voltage on open circuit</th>
<td>5V±20%</td>
</tr>
<tr>
<th>Output short circuit current</th>
<td>DC 220±20mA</td>
</tr>
<tr>
<th>Fuse</th>
<td>Quick acting ceramic fuse 0.5A/600V (Ø6.35×32mm)</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="mb10">
<h4 class="headLine4 mb10">AC Voltage</h4>
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>AC voltage range</th>
<td>AC 20 &#8211; 600V (50/60Hz)<br />
DC -20 &#8211; -600V/+20 &#8211; +600V</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±3%rdg±6dgt</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="mb10">
<h4 class="headLine4 mb10">General</h4>
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)</td>
</tr>
<tr>
<th>Power source</th>
<td>R6 × 6 or LR6 × 6</td>
</tr>
<tr>
<th>Dimensions / Weight</th>
<td>105(L) × 158(W) × 70(D)mm / 600g approx.</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7150A (Remote control switch set),<br />
9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7115 (Extension Probe), 8016 (Hook type prod),<br />
8923 (Fuse [0.5A/600V]), 9089 (Carrying Case)</td>
</tr>
</tbody>
</table>
</div>
</section>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-3023a-digital-insulation-continuity-tester/">KYORITSU 3023A Digital Insulation &#038; Continuity Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 2056R 1000A TRMS Digital AC/DC CAT IV Clamp Meter</title>
		<link>https://obiat.com.au/product/kyoritsu-2056r-1000a-trms-digital-ac-dc-cat-iv-clamp-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 17 Sep 2018 05:26:13 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=17346</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu 2056R is a CAT IV clamp meter with large 40mm jaws. The Kyoritsu 2056R can measure voltage and current in both low and high powered circuits and has the ability to read up to 1000A AC and DC plus 600V AC/DC.</p>
<p>The Kyoritsu 2056R's wide measurement range makes it suitable for use with power distribution companies, power utilities and maintenance sections.</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Cat-IV-Clampmeters.pdf" rel="noopener"><span style="text-decoration: underline;"><span style="font-size: 110%;">Kyoritsu-Cat-IV-Clampmeters</span></span></a></h4>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2056r-1000a-trms-digital-ac-dc-cat-iv-clamp-meter/">Kyoritsu 2056R 1000A TRMS Digital AC/DC CAT IV Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 2056R 1000A TRMS Digital AC/DC CAT IV Clamp Meter</h3>
<p>The Kyoritsu 2056R is a digital clamp meter is designed to meet international safety standard IEC 61010-1 CAT IV 600V and has the capability to read current up to 1000A AC/DC. The 2056R model features True RMS measurements providing greater accuracy on non-sinusoidal  and distorted waveforms.</p>
<p>The Kyoritsu 2056R also features a data hold function and peak hold function, as well as the ability to measure resistance up to 60MΩ. Temperature can be measured using an additional probe (not supplied) and capacitance can be tested. In addition, a max/min function is available to display the maximum and minimum values during a set period of time.</p>
<p>Furthermore, the tester has a non-contact voltage function, warning the user of AC voltage via a red LED indicator. Ergonomically designed, the Kyoritsu 2056R comprises a double moulded construction and features a bar graph display with backlight, for testing in low light conditions.</p>
<h3>Kyoritsu 2056R <strong>Features:</strong></h3>
<ul>
<li>Measures up to 1000A AC.</li>
<li>True RMS.</li>
<li>Measures up to 600V AC/DC.</li>
<li>Capacitance test.</li>
<li>Designed to meet international safety standard IEC 61010-1 CAT IV 600V.</li>
<li>40mm jaw size</li>
<li>Max/min function.</li>
<li>Temperature between -50°C amd +300°C (probe not supplied).</li>
<li>Measures resistance up to 60MΩ.</li>
<li>Peak hold function.</li>
<li>Double moulded construction.</li>
<li>Auto power off</li>
<li>Data hold function.</li>
<li>Bar graph display with backlight.</li>
</ul>
<h3>Kyoritsu 2056R Specifications:</h3>
<table class="specTable mb0" style="height: 810px;" width="695">
<tbody>
<tr>
<th><span style="font-size: 85%;">AC A (RMS)</span></th>
<td><span style="font-size: 85%;">0 &#8211; 600.0/1000A</span><br />
<span style="font-size: 85%;">±2.0%rdg±5dgt (50/60Hz)</span><br />
<span style="font-size: 85%;">±3.5%rdg±5dgt (40 &#8211; 500Hz)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">DC A</span></th>
<td><span style="font-size: 85%;">0 &#8211; 600.0/1000A</span><br />
<span style="font-size: 85%;">±1.5%rdg±5dgt</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">AC V</span></th>
<td><span style="font-size: 85%;">6/60/600V</span><br />
<span style="font-size: 85%;">Auto Ranging</span><br />
<span style="font-size: 85%;">±1.5%rdg±4dgt (50/60Hz)</span><br />
<span style="font-size: 85%;">±3.5%rdg±5dgt (40 &#8211; 400Hz)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">DC V</span></th>
<td><span style="font-size: 85%;">600m/6/60/600V</span><br />
<span style="font-size: 85%;">Auto Ranging</span><br />
<span style="font-size: 85%;">±1.0%rdg±3dgt</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Ω</span></th>
<td><span style="font-size: 85%;">600/6k/60k/600k/6M/60MΩ (Auto Ranging)</span><br />
<span style="font-size: 85%;">±1%rdg±5dgt (600 &#8211; 6M) / ±5%rdg±8dgt (60M)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Continuity buzzer</span></th>
<td><span style="font-size: 85%;">Buzzer Sounds at 100Ω</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Capacitance test</span></th>
<td><span style="font-size: 85%;">400n/4µ/40µF(Auto Ranging)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Temperature</span></th>
<td><span style="font-size: 85%;">-50ºC &#8211; +300ºC (With the use of Temperature probe 8216)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Frequency/DUTY</span></th>
<td><span style="font-size: 85%;">10/100/1k/10kHz (Auto Ranging) / 0.1 &#8211; 99.9%</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Conductor size</span></th>
<td><span style="font-size: 85%;">Ø40mm</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Safety Standard</span></th>
<td><span style="font-size: 85%;">IEC 61010-1 CAT IV 600V,</span><br />
<span style="font-size: 85%;">IEC 61010-031,</span><br />
<span style="font-size: 85%;">IEC 61010-2-032,</span><br />
<span style="font-size: 85%;">IEC 61326</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Power source</span></th>
<td><span style="font-size: 85%;">R03 (1.5V) (AAA) × 2</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Dimensions</span></th>
<td><span style="font-size: 85%;">254(L) × 82(W) × 36(D)mm</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Weight</span></th>
<td><span style="font-size: 85%;">310g</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Included Accessories</span></th>
<td><span style="font-size: 85%;">7066A (Test leads)</span><br />
<span style="font-size: 85%;">9094 (Carrying case)</span><br />
<span style="font-size: 85%;">Instruction Manual</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Optional Accessories</span></th>
<td><span style="font-size: 85%;">8216 (Temperature probe)</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2056r-1000a-trms-digital-ac-dc-cat-iv-clamp-meter/">Kyoritsu 2056R 1000A TRMS Digital AC/DC CAT IV Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 4106 Earth &#038; Ground Resistance Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-4106-earth-ground-resistance-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 17 Sep 2018 02:56:45 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=17341</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>Kyoritsu 4106 is a 2/ 3/ 4-wire digital earth resistance/earth resistivity tester, equipped with a microcomputer, for measuring earth resistances and calculating earth resistivities.<br />
It has an output voltage of 10 Vrms or lower. This makes it an instrument of choice for measuring earth resistances on installations ranging from in-house wiring systems and electrical appliances to power distribution lines.<br />
Sub-results that can be shown on the display include resistance of the auxiliary earth spikes, frequency of test current, voltage and frequency of interference (noise) and residual resistance Rk.</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-4106-Datasheet.pdf" rel="noopener">Kyoritsu-4106-Datasheet</a></span></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-4106-User-Manual.pdf" rel="noopener">Kyoritsu-4106-User-Manual</a></span></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-4106-earth-ground-resistance-tester/">Kyoritsu 4106 Earth &#038; Ground Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3 class="headLine5">Kyoritsu 4106 Earth &amp; Ground Resistance Tester</h3>
<p>• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.<br />
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.<br />
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.<br />
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.<br />
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.<br />
• Large Graphic Display with backlight for readings in poorly illuminated areas.<br />
• Up to 800 measurement results can be saved in the memory and recalled on the display.<br />
• The stored results can be transferred to a PC using the &#8220;KEW Report&#8221; software and a USB adaptor (Model 8212-USB) which are included.<br />
• Robust design with IP54 protection.</p>
<h3 style="text-align: center;">Earth Resistance Measurements with 4, 3 and 2 Wires</h3>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel.jpg"><img decoding="async" class="size-full wp-image-6332 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2018/03/KYORITSU-4106-Panel.jpg" alt="" width="983" height="244" /></a></p>
<h3>Kyoritsu 4106 Earth &amp; Ground Resistance Tester Specifications:</h3>
<div class="editor">
<div class="tableScroller">
<table>
<tbody>
<tr>
<th><span style="font-size: 85%;">Function</span></th>
<th><span style="font-size: 85%;">Range</span></th>
<th><span style="font-size: 85%;">Resolution</span></th>
<th><span style="font-size: 85%;">Measuring range</span></th>
<th><span style="font-size: 85%;">Accuracy</span></th>
</tr>
<tr>
<th rowspan="6"><span style="font-size: 85%;">Earth resistance</span><br />
<span style="font-size: 85%;">Re</span><br />
<span style="font-size: 85%;">(Rg at</span><br />
<span style="font-size: 85%;">ρ measurement)</span></th>
<td><span style="font-size: 85%;">2Ω</span></td>
<td><span style="font-size: 85%;">0.001Ω</span></td>
<td><span style="font-size: 85%;">0.03 &#8211; 2.099Ω</span></td>
<td><span style="font-size: 85%;">±2%rdg±0.03Ω</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">20Ω</span></td>
<td><span style="font-size: 85%;">0.01Ω</span></td>
<td><span style="font-size: 85%;">0.03 &#8211; 20.99Ω</span></td>
<td rowspan="5"><span style="font-size: 85%;">±2%rdg±5dgt (*1)</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">200Ω</span></td>
<td><span style="font-size: 85%;">0.1Ω</span></td>
<td><span style="font-size: 85%;">0.3 &#8211; 209.9Ω</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">2000Ω</span></td>
<td><span style="font-size: 85%;">1Ω</span></td>
<td><span style="font-size: 85%;">3 &#8211; 2099Ω</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">20kΩ</span></td>
<td><span style="font-size: 85%;">10Ω</span></td>
<td><span style="font-size: 85%;">0.03k &#8211; 20.99kΩ</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">200kΩ</span></td>
<td><span style="font-size: 85%;">100Ω</span></td>
<td><span style="font-size: 85%;">0.3k &#8211; 209.9kΩ</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Auxiliary earth resistance</span><br />
<span style="font-size: 85%;">Rh, Rs</span></th>
<td></td>
<td></td>
<td></td>
<td><span style="font-size: 85%;">8% of Re+Rh+Rs</span></td>
</tr>
<tr>
<th rowspan="6"><span style="font-size: 85%;">Earth resistivity</span><br />
<span style="font-size: 85%;">ρ</span></th>
<td><span style="font-size: 85%;">2Ω</span></td>
<td rowspan="6"><span style="font-size: 85%;">0.1Ω·mm &#8211; 1Ω·m</span><br />
<span style="font-size: 85%;">Autoranging</span></td>
<td><span style="font-size: 85%;">0.2 &#8211; 395.6Ω·m</span></td>
<td rowspan="6"><span style="font-size: 85%;">ρ=2×π×a×Rg (*2)</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">20Ω</span></td>
<td><span style="font-size: 85%;">0.2 &#8211; 3956Ω·m</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">200Ω</span></td>
<td><span style="font-size: 85%;">20 &#8211; 39.56kΩ·m</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">2000Ω</span></td>
<td><span style="font-size: 85%;">0.2 &#8211; 395.6kΩ·m</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">20kΩ</span></td>
<td rowspan="2"><span style="font-size: 85%;">2.0 &#8211; 1999kΩ·m</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">200kΩ</span></td>
</tr>
<tr>
<th rowspan="2"><span style="font-size: 85%;">Series interference voltage</span><br />
<span style="font-size: 85%;">Ust (A.C only) (*3)</span></th>
<td rowspan="2"><span style="font-size: 85%;">50V</span></td>
<td rowspan="2"><span style="font-size: 85%;">0.1V</span></td>
<td rowspan="2"><span style="font-size: 85%;">0 &#8211; 50.9Vrms</span></td>
<td><span style="font-size: 85%;">±2%rdg±2dgt (50/60Hz)</span></td>
</tr>
<tr>
<td><span style="font-size: 85%;">±3%rdg±2dgt (40 &#8211; 500Hz)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Frequency</span><br />
<span style="font-size: 85%;">Fst</span></th>
<td><span style="font-size: 85%;">Autoranging</span></td>
<td><span style="font-size: 85%;">0.1Hz</span><br />
<span style="font-size: 85%;">1Hz</span></td>
<td><span style="font-size: 85%;">40Hz &#8211; 500Hz</span></td>
<td><span style="font-size: 85%;">±1%rdg±2dgt</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Measuring method</span></th>
<td colspan="4"><span style="font-size: 85%;">Earth resistance: Fall-of-potential method</span><br />
<span style="font-size: 85%;">(currents and voltages measured via the Probes)</span><br />
<span style="font-size: 85%;">Measurement method of Earth Resistivity (ρ): Wenner 4-pole method</span><br />
<span style="font-size: 85%;">Series interference voltage (earth voltage)</span><br />
<span style="font-size: 85%;">RMS Rectifier (between the E-S Terminals)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Memory capacity</span></th>
<td colspan="4"><span style="font-size: 85%;">800 data</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Communication Interface</span></th>
<td colspan="4"><span style="font-size: 85%;">Model 8212-USB Optical Adaptor</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">LCD</span></th>
<td colspan="4"><span style="font-size: 85%;">Dot-matrix 192×64 monochrome</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Over-range Indication</span></th>
<td colspan="4"><span style="font-size: 85%;">&#8220;OL&#8221;</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Overload Protection</span></th>
<td colspan="4"><span style="font-size: 85%;">between E-S(P) and between E-H(C) terminals AC280V / 10 sec.</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Applicable standards</span></th>
<td colspan="4"><span style="font-size: 85%;">IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2</span><br />
<span style="font-size: 85%;">IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Power source</span></th>
<td colspan="4"><span style="font-size: 85%;">DC12V : sizeAA manganese dry battery (R6) × 8</span><br />
<span style="font-size: 85%;">(Auto power off: approx. 5 minutes)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Dimensions</span></th>
<td colspan="4"><span style="font-size: 85%;">167(L) × 185(W) × 89(D) mm</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Weight</span></th>
<td colspan="4"><span style="font-size: 85%;">approx. 900g (including batteries)</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Accessories</span></th>
<td colspan="4"><span style="font-size: 85%;">7229A (Earth precision measurement),</span><br />
<span style="font-size: 85%;">7238A (Simplified measurement test leads),</span><br />
<span style="font-size: 85%;">8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),</span><br />
<span style="font-size: 85%;">8200-04 (Cord reel [4 pcs])×1 set,</span><br />
<span style="font-size: 85%;">8212-USB (USB adaptor with &#8220;KEW Report(Software)&#8221;),</span><br />
<span style="font-size: 85%;">9121 (Shoulder strap),</span><br />
<span style="font-size: 85%;">9125 (Carrying case),</span><br />
<span style="font-size: 85%;">R6 × 8, Instruction manual, Calibration certificate</span></td>
</tr>
<tr>
<th><span style="font-size: 85%;">Optional</span></th>
<td colspan="4"><span style="font-size: 85%;">8212-RS232C (RS232C adaptor with &#8220;KEW Report(Software)&#8221;)</span></td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10"></section>
<div class="editor">
<p><span style="font-size: 85%;">(*1) Auxiliary earth resistance is 100Ω with Rk correction</span><br />
<span style="font-size: 85%;">(*2) Depending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0 &#8211; 30.0m</span><br />
<span style="font-size: 85%;">(*3) This instrument is NOT designed to measure line voltages on commercial powers.</span></p>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-4106-earth-ground-resistance-tester/">Kyoritsu 4106 Earth &#038; Ground Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 5020 TRMS Current / Voltage Data Logger</title>
		<link>https://obiat.com.au/product/kyoritsu-5020-trms-current-voltage-data-logger/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 17 Sep 2018 02:12:49 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=17333</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p class="short-description mhide ipad-view-setting">The Kyoritsu 5020 TRMS Current/Voltage Data Logger has three input channels for the simultaneous recording of load current and voltage.</p>
<p class="short-description mhide ipad-view-setting">Various measurements are available with four recording modes: Normal, Trigger, Capture and Power Quality Analysis.</p>
<p>The Kyoritsu 5020 data logger is capable of storing up to 60,000 measurements and features non-volatile memory that allows recorded data to be retained even if power is lost.</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-5020-Datasheet.pdf" rel="noopener">Kyoritsu-5020-Datasheet</a></span></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-5020-User-Manual.pdf" rel="noopener">Kyoritsu-5020-User-Manual</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-5020-trms-current-voltage-data-logger/">Kyoritsu 5020 TRMS Current / Voltage Data Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 5020 TRMS 3-Channel Current / Voltage Data Logger Features:</h3>
<div class="row"  id="row-2098368802">

	<div id="col-1715291554" class="col medium-2/3 large-8"  >
				<div class="col-inner"  >
			
			
<ul>
<li>Power Quality Analysis: Reference voltage, Swell, Dip, Short power Interruptions.</li>
<li>Variation of the measured voltage and current data can be confirmed simultaneously on the PC display monitor.</li>
<li>Large capacity for storing 60,000 data points when 1 channel is used, and when all the three channels are used, 20,000 data points per channel can be recorded.</li>
<li>Lowpass Filter will filter out the harmonics (cutoff frequency = approx. 160Hz)</li>
<li>LED flickers when the preset current / voltage value is exceeded</li>
</ul>
		</div>
					</div>

	

	<div id="col-1431532250" class="col medium-1/3 large-4"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020_01.jpg"><img decoding="async" class="alignnone wp-image-7664" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020_01.jpg" alt="" width="164" height="183" /></a><br />
		</div>
					</div>

	
</div>
<ul>
<li>The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)</li>
<li>The last 10 recorded data points including time/date can be recalled on the logger display</li>
<li>Selection of One-time mode or Endless mode:<br />
One-time on: Recording will stop when memory is used up<br />
One-time off: Overwrite the old data, and store the latest data</li>
<li>Non Volatile Memory: Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)</li>
<li>Battery power indicator: Indicates battery voltage in 4-levels (It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)</li>
<li>User-friendly PC software &#8220;KEW LOG Soft 2&#8221; is supplied</li>
<li>Permits editing, analysis and graphical display of data.</li>
<li>Recorded data is downloadable onto a PC via USB cable.</li>
<li>Simplified Power Integration: (The &#8220;KEW LOG Soft 2&#8221; uses current and voltage recorded to calculate the integral power consumption).</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes.jpg"><img decoding="async" class="alignnone size-full wp-image-7662" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes.jpg" alt="" width="945" height="783" /></a></p>
<h4><span style="font-size: 110%;">Kyoritsu 5020 TRMS 3-Channel Data Logger Specifications:</span></h4>
<div class="editor">
<p>Normal Recording Mode<br />
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>RMS Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±2.0%rdg±0.9%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±1.5%rdg±0.7%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Crest Factor</td>
<td>2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.</td>
</tr>
</tbody>
</table>
</div>
<p>*Max, Min and Instant Peak values in Normal Recording mode are just reference values:<br />
their accuracies aren&#8217;t guaranteed.</p>
<p>Trigger Recording Mode (AC 50/60Hz sine wave)</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±3.5%rdg±2.2%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±3.0%rdg±2.0%f.s.+ Accuracy of Sensor</td>
</tr>
</tbody>
</table>
</div>
<p>Capture Recording Mode</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±3.0%rdg±1.7%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±2.5%rdg±1.5%f.s.+ Accuracy of Sensor</td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10">
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Recording mode</th>
<td>Normal, Trigger, Capture, Power Quality Analysis</td>
</tr>
<tr>
<th>Operating system</th>
<td>Successive Approximation<br />
(CH1 single synchronized sampling)</td>
</tr>
<tr>
<th>Rated max. working voltage</th>
<td>AC 9.9Vrms, 14V peak value</td>
</tr>
<tr>
<th>Number of input channel</th>
<td>3ch</td>
</tr>
<tr>
<th>Measuring method</th>
<td>True RMS</td>
</tr>
<tr>
<th>RMS measuring interval</th>
<td>approx. 100ms</td>
</tr>
<tr>
<th>Sampling interval</th>
<td>Normal/Trigger mode : approx. 1.65ms/CH<br />
Capture mode : approx. 0.55ms (waveform: at every 1.1ms)<br />
P.Q.A. mode : approx. 0.55ms</td>
</tr>
<tr>
<th>Low battery warning</th>
<td>Battery mark display (in 4 levels)</td>
</tr>
<tr>
<th>Over-range indication</th>
<td>&#8220;OL&#8221; mark is displayed when exceeding the measuring range</td>
</tr>
<tr>
<th>Auto power off</th>
<td>Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)</td>
</tr>
<tr>
<th>Possible measurement time</th>
<td>Approx. 10 days (with alkaline LR6 batteries)</td>
</tr>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1:2001 CAT III 300V Pollution degree2<br />
IEC 61326 (EMC standard)</td>
</tr>
<tr>
<th>Dimensions</th>
<td>111(L)×60(W)×42(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>Approx. 265g</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>Alkaline battery LR6×4pcs, 9118 (Carrying case)<br />
PC software &#8220;KEW LOG Soft 2&#8221;, 7148 (USB cable)<br />
Instruction manual, Quick manual, Install manual,<br />
USB Notice sheet</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>8146/8147/8148 (Leakage &amp; Load current Clamp Sensor),<br />
8121/8122/8123 (Load current Clamp Sensor),<br />
8129/8130 (Flexible Clamp Sensor),<br />
8309 (Voltage Sensor: only KEW 5020), 8320 (AC Adapter),<br />
9135 (Carrying bag), 9119 (Hard carry case),<br />
7185 (Extension cable for sensor)</td>
</tr>
</tbody>
</table>
</div>
</section>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-5020-trms-current-voltage-data-logger/">Kyoritsu 5020 TRMS Current / Voltage Data Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 2510 Milliamp Process Clamp Logger</title>
		<link>https://obiat.com.au/product/kyoritsu-2510-milliamp-process-clamp-logger/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 12 Sep 2018 07:13:38 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=16872</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>Kyoritsu 2510 measures 4 to 20 mA instrumentation and processes signals without breaking the loop. You can also transfer data to you PC via Bluetooth for easy access</p>
<p>• Measures 4 to 20 mA instrumentation and process signals without breaking the loop<br />
• Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding<br />
• Transfer data to PC via Bluetooth<br />
• Top class measurement 0.2% accuracy<br />
• ∅6mm clamp jaw easy to use in tight places<br />
• LED light for illuminating the measurement spot<br />
• Analogue output terminal to allow the connection to a recorder or a digital multimeter</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline; font-size: 105%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-2510-Datasheet.pdf" rel="noopener">Kyoritsu-2510-Datasheet</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2510-milliamp-process-clamp-logger/">Kyoritsu 2510 Milliamp Process Clamp Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Kyoritsu 2510 Milliamp Process Clamp Logger measures 4 to 20 mA instrumentation and process signals without breaking the loop. You can also transfer data to you PC via Bluetooth for easy access.</p>
<p><strong>Kyoritsu 2510 Features:</strong></p>
<ul>
<li>Memory function stores up to 192000 data useful for monitoring the signals over time and fault finding</li>
<li>Transfers data to PC via Bluetooth</li>
<li>Top class measurement 0.2% accuracy</li>
<li>6mm clamp jaw is easy to use in tight places</li>
<li>LED light for illuminating the measurement spot</li>
<li>Analog output terminal to allow the connection to a recorder or a digital multimeter</li>
</ul>
<p><strong>Kyoritsu 2510 DC Milliamp Process Clamp Applications:</strong></p>
<ul>
<li>Residential</li>
<li>Industrial</li>
<li>Commercial</li>
<li>Electrical Engineering</li>
<li>Electronic Testing</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-2510-Communications.jpg"><img decoding="async" class="alignnone wp-image-6208 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-2510-Communications.jpg" alt="" width="600" height="435" /></a></p>
<h4>Kyoritsu 2510 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td>AC A</td>
<td>20/100mA(Auto ranging) ±0.2%rdg±5dgt (0.00mA &#8211; 21.49mA)</td>
</tr>
<tr>
<td>Conductor size</td>
<td>Ø6mm max.</td>
</tr>
<tr>
<td>Analogue output</td>
<td>Recorder: DC1000mV against DC100mA</td>
</tr>
<tr>
<td>Operating temperature &amp; humidity range</td>
<td>-10 &#8211; +50°C &lt;85%</td>
</tr>
<tr>
<td>Storage temperature &amp; humidity range</td>
<td>-20 &#8211; +60°C &lt;85%</td>
</tr>
<tr>
<td>Power source</td>
<td>R6/LR6(AA) (1.5V) x4 (Alkaline LR6 is recommended.) External supply (AC adapter MODEL8320)</td>
</tr>
<tr>
<td>Communication interface</td>
<td>Bluetooth Ver2.1+EDR Class2</td>
</tr>
<tr>
<td>Weight</td>
<td>Approx. 310g (including batteries)</td>
</tr>
</tbody>
</table>
<p><strong><em>See Datasheet above for full specifications:</em></strong></p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-25XX-comparison.jpg"><img decoding="async" class="alignnone wp-image-6209 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-25XX-comparison.jpg" alt="" width="593" height="441" /></a></p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2510-milliamp-process-clamp-logger/">Kyoritsu 2510 Milliamp Process Clamp Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 2500 Milliamp Process Clamp Meter</title>
		<link>https://obiat.com.au/product/kyoritsu-2500-milliamp-process-clamp-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 12 Sep 2018 07:02:13 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=16868</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu 2500 is a high resolution, low current DC clamp meter that is ideal for measuring and monitoring 4-20mA current loops without breaking the loop. Featuring a 0.01mA resolution and 0.02% accuracy the Kyoritsu 2500 is ideal for automotive and process control industries.</p>
<p><strong>Features:</strong></p>
<p>• 0.01mA resolution for DC current<br />
• Top class measurement 0.2% accuracy<br />
• Ø6mm clamp jaw easy to use in tight places<br />
• Measurement from 0.01mA to 120.0mA<br />
• Dual display with backlight shows both mA measurement and percent of 4-20 mA span<br />
• Spotlight for illuminating measurement point<br />
• Analogue output terminal for recorder connection</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-2500-Datasheet.pdf" rel="noopener noreferrer"><span style="text-decoration: underline;"><span style="font-size: 110%;">Kyoritsu-2500-Datasheet</span></span></a></h4>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2500-milliamp-process-clamp-meter/">Kyoritsu 2500 Milliamp Process Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong><span style="font-size: 120%;">Kyoritsu 2500 Milliamp Process Clamp Meter</span></strong></p>
<p>The Kyoritsu 2500 is a high precision millliamp clamp meter with a specified 0.02% accuracy. Possessing a 0.01mA resolution, the 2500 model is capable of measuring DC current from 0.01mA to 120mA.</p>
<p>The Kyoritsu 2500 DC Milliamp Process Clamp Meter is ideal in maintaining and troubleshooting process and automation equipment without breaking the loop and interuppting the process.</p>
<p>The Kyoritsu 2500 DC Milliamp Process Clamp Meter comprises a 6mm clamp jaw, allowing the meter to be utilised in tight working conditions. An analog output terminal is also present on the tester, providing the ability to integrate a recorder or logger.</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-2500b.jpg"><img decoding="async" class="alignnone wp-image-6204 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-2500b.jpg" alt="" width="621" height="454" /></a></p>
<h3>Kyoritsu 2500 DC Milliamp Process Clamp Meter Specifications:</h3>
<table class="specTable mb0">
<tbody>
<tr>
<th>DC A</th>
<td>20/100mA (Auto ranging)<br />
±0.2%rdg±5dgt (0.00mA &#8211; 21.49mA)<br />
±1.0%rdg±5dgt (21.0mA &#8211; 120.0mA)</td>
</tr>
<tr>
<th>Conductor size</th>
<td>Ø6mm max.</td>
</tr>
<tr>
<th>Analogue output</th>
<td>Recorder: DC 1000mV against DC 100mA</td>
</tr>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1, Pollution degree 2<br />
IEC 61010-2-032, IEC 61326-1(EMC)<br />
IEC 60529 IP40, EN50581(RoHS)</td>
</tr>
<tr>
<th>Operating temperature &amp; humidity range</th>
<td>-10 &#8211; +50ºC &lt; 85%</td>
</tr>
<tr>
<th>Storage temperature &amp; humidity range</th>
<td>-20 &#8211; +60ºC &lt; 85%</td>
</tr>
<tr>
<th>Power source</th>
<td>R6/LR6 (AA) (1.5V) × 4</td>
</tr>
<tr>
<th>Dimensions</th>
<td>111(L) × 61(W) × 40(D)mm : Display unit<br />
104(L) × 34(W) × 20(D)mm : Sensor<br />
700mm : Sensor cable</td>
</tr>
<tr>
<th>Weight</th>
<td>Approx. 290g (including batteries)</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>9096 (Carrying case), LR6 (AA) × 4,<br />
Instruction Manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7256 (Output cord)</td>
</tr>
</tbody>
</table>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-25XX-comparison.jpg"><img decoding="async" class="alignnone wp-image-6209 size-full" src="https://rapid-tech.com.au/wp-content/uploads/2018/02/Kyoritsu-25XX-comparison.jpg" alt="" width="593" height="441" /></a></p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2500-milliamp-process-clamp-meter/">Kyoritsu 2500 Milliamp Process Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 3128 12kV High Voltage Insulation Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-3128-12kv-high-voltage-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 12 Sep 2018 06:44:35 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=16860</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu <span class="highlight">3128</span> is a digital CAT IV High Voltage Insulation Tester with capabilities of testing insulation resistance up to 35TΩ at test voltages up to 12kV. The Kyoritsu <span class="highlight">3128</span> model is designed for field use with an IP64 rating and features a large backlit LCD display.</p>
<p>• Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.<br />
• Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.<br />
• 6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V<br />
Fine adjustment of voltage setting at each range is also possible<br />
• Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.<br />
• Can be operated from built-in rechargeable battery or from AC line.<br />
• Automatic discharge after test with monitoring of the discharge voltage.<br />
• Internal memory can store about 43,000 data (max).<br />
• Robust design for field use with IP64 rating (with lid closed)</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-3128-Datasheet.pdf" rel="noopener"><span style="text-decoration: underline;"><span style="font-size: 105%;">Kyoritsu-3128-Datasheet</span></span></a></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-3128-12kv-high-voltage-insulation-tester/">Kyoritsu 3128 12kV High Voltage Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Kyoritsu 3128 12kV High Voltage Insulation Tester is a microprocessor controlled tester and includes various diagnostic functions that provide the ability to test the polarization index (PI), the dielectric absorption ratio (DAR) and the dielectric discharge (DD). Step voltage (SV) measurements can be made where successive voltage increments are implemented to test the degradation of insulation.7</p>
<p>Using the Kyoritsu 3128 High Voltage Insulation Tester insulation resistances can be measured up to 35TΩ, with test voltages up to 12kV</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-3128-Display.jpg"><img decoding="async" class="alignnone size-full wp-image-5854" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-3128-Display.jpg" alt="" width="824" height="471" /></a></p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-Measurement.jpg"><img decoding="async" class="alignnone size-full wp-image-5855" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-Measurement.jpg" alt="" width="828" height="785" /></a></p>
<h3>Kyoritsu 3128 12kV High Voltage Insulation Tester Specifications:</h3>
<div class="editor">
<p class="tm3"><em>Insulation resistance (*): Accuracy is not guaranteed with setting of 250V or less</em></p>
<table>
<tbody>
<tr>
<th>Rated voltage</th>
<td>500V</td>
<td>1000V</td>
<td>2500V</td>
<td>5000V</td>
<td>10000V</td>
<td>12000V</td>
</tr>
<tr>
<th>Max measurement value</th>
<td>500GΩ</td>
<td>1TΩ</td>
<td>2.5TΩ</td>
<td>5TΩ</td>
<td colspan="2">35TΩ</td>
</tr>
<tr>
<th rowspan="3">Accuracy</th>
<td>400k～50GΩ ±5%rdg±3dgt<br />
(*)</td>
<td>800k～100GΩ 5%rdg±3dgt</td>
<td>2M～250GΩ ±5%rdg±3dgt</td>
<td>4M～500GΩ ±5%rdg±3dgt</td>
<td colspan="2">8M～1TΩ ±5%rdg±3dgt</td>
</tr>
<tr>
<td rowspan="2">50G～500GΩ<br />
±20%rdg<br />
(*)</td>
<td rowspan="2">100G～1TΩ<br />
±20%rdg</td>
<td rowspan="2">250G～2.5TΩ<br />
±20%rdg</td>
<td rowspan="2">500G～5TΩ<br />
±20%rdg</td>
<td colspan="2">1T～10TΩ<br />
±20%rdg</td>
</tr>
<tr>
<td colspan="2">10T &#8211; 35TΩ<br />
Values are displayed, but accuracy isn&#8217;t guaranteed</td>
</tr>
<tr>
<th>Short circuit current</th>
<td colspan="6">Max 5.0mA</td>
</tr>
<tr>
<th>Load resistor to output rated voltage</th>
<td>0.5MΩ or more</td>
<td>1MΩ or more</td>
<td>2.5MΩ or more</td>
<td>5MΩ or more</td>
<td>20MΩ or more</td>
<td>24MΩ or more</td>
</tr>
</tbody>
</table>
<h4 class="tm3">Output voltage</h4>
<table>
<tbody>
<tr>
<th>Rated voltage</th>
<td>500V</td>
<td>1000V</td>
<td>2500V</td>
<td>5000V</td>
<td>10000V</td>
<td>12000V</td>
</tr>
<tr>
<th>Monitor accuracy</th>
<td>±10%±20V</td>
<td>±10%±20V</td>
<td>±10%±20V</td>
<td>±10%±20V</td>
<td>±10%±20V</td>
<td>±10%±20V</td>
</tr>
<tr>
<th>Output accuracy</th>
<td>0 &#8211; +20%</td>
<td>0 &#8211; +10%</td>
<td>0 &#8211; +10%</td>
<td>0 &#8211; +10%</td>
<td>-5 &#8211; +5%</td>
<td>-5 &#8211; +5%</td>
</tr>
<tr>
<th>Selectable range</th>
<td>50 &#8211; 600V<br />
(in steps of 5V)</td>
<td>610 &#8211; 1200V (in steps of 10V)</td>
<td>1225 &#8211; 3000V <span class="s1">(in steps of 25V)</span></td>
<td>3050 &#8211; 6000V <span class="s1">(in steps of 50V)</span></td>
<td>6100 &#8211;<br />
10000V <span class="s1">(in steps of 100V)</span></td>
<td>10100 &#8211; 12000V <span class="s1">(in steps of 100V)</span></td>
</tr>
</tbody>
</table>
<h4 class="tm3"><b>Voltage measurement</b></h4>
<table>
<tbody>
<tr>
<th>Measuring range</th>
<td>DCV：±30 ～ ±600V、ACV：30 ～ 600V （50/60Hz）</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±2%rdg±3dgt</td>
</tr>
</tbody>
</table>
<h4 class="tm3">Current measurement</h4>
<table>
<tbody>
<tr>
<th>Measuring range</th>
<td>5.00nA &#8211; 2.40mA (Depending on the insulation resistance)</td>
</tr>
</tbody>
</table>
<h4 class="tm3">Capacitance measurement</h4>
<table>
<tbody>
<tr>
<th>Measuring range</th>
<td>5.0nF ～ 50.0μF<br />
(500V/1000V/2500V/5000V)</td>
<td>5.0nF &#8211; 1.0µF (display range: 5.0nF &#8211; 50.0µF) (10000V/12000V)</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="2">±5%rdg±5dgt</td>
</tr>
</tbody>
</table>
</div>
<section class="mb10">
<h4 class="headLine4 mb10">General</h4>
<table class="specTable mb0">
<tbody>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT IV 600V Pollution degree 2,<br />
IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed.</td>
</tr>
<tr>
<th>Operating temperature &amp; humidity range</th>
<td>-10ºC &#8211; Relative humidity 85% or less<br />
50ºC /(when operating with an external power supply, no condensation)<br />
0ºC &#8211; 40ºC /Relative humidity 85% or less<br />
(when operating with battery, no condensation)</td>
</tr>
<tr>
<th>Storage temperature &amp; humidity range</th>
<td>-20ºC &#8211; 60ºC / Relative humidity 75% or less (no condensation)</td>
</tr>
<tr>
<th>Power source</th>
<td>Rechargeable Lead storage battery (12V)*<br />
Charging time: approx. 8 hours / AC Power supply (100V &#8211; 240V, 50/60Hz)<br />
* Continuous measuring time:<br />
approx. 4 hours<br />
(a load of 100MΩ at the Insulation resistance 12000V Range.)<br />
approx. 2 hours<br />
(Max current consumption in range while rated currents are maintained.)</td>
</tr>
<tr>
<th>Dimensions</th>
<td>330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case</td>
</tr>
<tr>
<th>Weight</th>
<td>9kg approx. (including battery) *Instrument and Hard case</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7170 (Main cord), 7224A (Earth cord), 7225A (Guard cord), 7226A (Line probe),<br />
7227A (Line probe with alligator clip), 8029 (Extension prod),<br />
8212-USB-W (USB adaptor with KEW Windows (Software)),<br />
Instruction manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7254 (Longer Line probe with alligator clip)</td>
</tr>
</tbody>
</table>
</section>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-3128-12kv-high-voltage-insulation-tester/">Kyoritsu 3128 12kV High Voltage Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 6201A Portable Appliance Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-6201a-portable-appliance-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 12 Jul 2018 08:11:26 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=12660</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2015/12/Kyoritsu_Logo_main.gif"><img class="alignnone size-full wp-image-27" src="https://obiat.com.au/wp-content/uploads/2015/12/Kyoritsu_Logo_main.gif" alt="" width="146" height="25" /></a></p>
<p>The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of Class 1 &#38; Class II appliances. And also can measure the mains voltage.<br />
Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/07/Kyoritsu-6201A-User-Manual.pdf" rel="noopener noreferrer">Kyoritsu-6201A-User-Manual</a></span></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-6201a-portable-appliance-tester/">Kyoritsu 6201A Portable Appliance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="editor">
<h3>Kyoritsu 6201A Portable Appliance Tester</h3>
<p><b>Portable appliance testing</b> (commonly known as &#8220;PAT&#8221;, &#8220;PAT Inspection&#8221; or as &#8220;PAT Testing&#8221;) is the name of a process by which electrical appliances are routinely checked for safety. The formal term for the process is &#8220;in-service inspection &amp; testing of electrical equipment&#8221;.</p>
<p>Testing involves a <strong>visual inspection of the equipment</strong> and any flexible cables for good condition, and also where required, <strong>verification of earthing (grounding) continuity</strong>, and a test of the <strong>soundness of insulation between the current carrying parts</strong>, and any exposed metal that may be touched.</p>
<p>The Kyoristu 6201A is a highly reliable, easy to use and reliable portable appliance tester with fast testing times and easy test selection &#8211; just by turn the rotary dial to the test you require and it will automatically complete the tests in less than 5 seconds. The Kyoritsu 6201A also features a convenient auto test sequencing function. When the test is complete, the 6201A&#8217;s LCD display will indicate a <strong>PASS or FAIL</strong> with its four LED lights.</p>
<p>The Kyoritsu 6201A Portable Appliance Tester is suitable for performing tests as required by the following standards.<br />
AS/NZS 3760 In-service safety inspection and testing of electrical equipment.</p>
<h3>Kyoritsu 6201A Portable Appliance Tester Specifications:</h3>
<h4 class="tm4">Test Function</h4>
<table>
<tbody>
<tr>
<th><span style="font-size: 90%;">Function</span></th>
<th><span style="font-size: 90%;">Tests of contents</span></th>
</tr>
<tr>
<td><span style="font-size: 90%;">Test ⅠClass</span></td>
<td><span style="font-size: 90%;">Protective conductor resistance</span><br />
<span style="font-size: 90%;">Insulation (250V or 500V)</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;">Test ⅠSELECT Switch + Class</span></td>
<td><span style="font-size: 90%;">Protective conductor resistance</span><br />
<span style="font-size: 90%;">Leakage Current test</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;">TestⅡClass</span></td>
<td><span style="font-size: 90%;">Insulation (250V or 500V)</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;">TestⅡSELECT Switch + Class</span></td>
<td><span style="font-size: 90%;">Leakage Current test</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;">Extension Leads test</span></td>
<td><span style="font-size: 90%;">Protective conductor resistance</span><br />
<span style="font-size: 90%;">Insulation P/N-PE</span><br />
<span style="font-size: 90%;">Polarity</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;">SELECT Switch + Extension Leads test</span></td>
<td><span style="font-size: 90%;">Protective conductor resistance</span><br />
<span style="font-size: 90%;">Leakage Current test</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;">Leakage Current Test</span></td>
<td><span style="font-size: 90%;">Leakage current measurement</span></td>
</tr>
</tbody>
</table>
</div>
<div class="editor">
<h4 class="tm3">RPE 20Ω Protective Conductor Resistance Test</h4>
<table>
<tbody>
<tr>
<th><span style="font-size: 90%;">Measuring range</span></th>
<td><span style="font-size: 90%;"> 0 &#8211; 15.00Ω</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Resolution of measurement</span></th>
<td><span style="font-size: 90%;">10mΩ</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Open circuit voltage</span></th>
<td><span style="font-size: 90%;">&lt; AC 12V</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Measuring current</span></th>
<td><span style="font-size: 90%;">10A AC nominal value</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Accuracy</span></th>
<td><span style="font-size: 90%;">±3%rdg±5dgt</span></td>
</tr>
</tbody>
</table>
<h4 class="tm3">RINS 200MΩ Insulation Resistance</h4>
<table>
<tbody>
<tr>
<th><span style="font-size: 90%;">Rating</span></th>
<td><span style="font-size: 90%;">250V/20MΩ</span></td>
<td><span style="font-size: 90%;">500V/20MΩ</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Measuring range</span></th>
<td colspan="2"><span style="font-size: 90%;">0 &#8211; 19.99Ω</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Resolution of measurement</span></th>
<td colspan="2"><span style="font-size: 90%;">10kΩ</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Output voltage</span></th>
<td><span style="font-size: 90%;">250V DC (+20%/-10%) @1MΩ</span></td>
<td><span style="font-size: 90%;">500V DC (+20%/-10%) @1MΩ</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Short circuit current</span></th>
<td colspan="2"><span style="font-size: 90%;">2.5mA DC or less</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Accuracy</span></th>
<td colspan="2"><span style="font-size: 90%;">±2%rdg±3dgt</span></td>
</tr>
</tbody>
</table>
<h4 class="tm3">Leakage Current Test</h4>
<table>
<tbody>
<tr>
<th><span style="font-size: 90%;">Measuring range</span></th>
<td><span style="font-size: 90%;">AC 0.1 &#8211; 19.99mA</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Resolution of measurement</span></th>
<td><span style="font-size: 90%;">0.01mA</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Examination time</span></th>
<td><span style="font-size: 90%;">Max 15 seconds</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Accuracy</span></th>
<td><span style="font-size: 90%;">±3%rdg±5dgt</span></td>
</tr>
</tbody>
</table>
<h4 class="tm3">AC VOLT Mains Voltage Check</h4>
<table>
<tbody>
<tr>
<th><span style="font-size: 90%;">Measuring range</span></th>
<td><span style="font-size: 90%;">207 &#8211; 264V</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Resolution of measurement</span></th>
<td><span style="font-size: 90%;">1V</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Accuracy</span></th>
<td><span style="font-size: 90%;">±2%rdg±3dgt</span></td>
</tr>
</tbody>
</table>
</div>
<section class="mb10">
<h4 class="headLine4 mb10">General</h4>
<table class="specTable mb0">
<tbody>
<tr>
<th><span style="font-size: 90%;">Supply voltage</span></th>
<td><span style="font-size: 90%;">240V±10%</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Frequency</span></th>
<td><span style="font-size: 90%;">50Hz±1%</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Applicable standards</span></th>
<td><span style="font-size: 90%;">IEC 61010-1 CAT III 300V Pollution Degree2</span><br />
<span style="font-size: 90%;">IEC 61326-1 (EMC)</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Dimensions</span></th>
<td><span style="font-size: 90%;">167(L) × 185 (W) × 89 (D) mm</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Weight</span></th>
<td><span style="font-size: 90%;">1.2kg (only the instrument body)</span></td>
</tr>
<tr>
<th><span style="font-size: 90%;">Included Accessories</span></th>
<td><span style="font-size: 90%;">7123 (Power cord [AU])</span><br />
<span style="font-size: 90%;">7129A (Test leads with alligator clip)</span><br />
<span style="font-size: 90%;">7161A (Flat test prod [black])</span><br />
<span style="font-size: 90%;">7140 (Adapter for exntesion cord)</span><br />
<span style="font-size: 90%;">9147 (Cord case)</span><br />
<span style="font-size: 90%;">9121 (Shoulder strap)</span><br />
<span style="font-size: 90%;">Instruction manual</span></td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7121B (Distribution board test leads)</td>
</tr>
</tbody>
</table>
</section>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-6201a-portable-appliance-tester/">Kyoritsu 6201A Portable Appliance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
