<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Loop / PSC Testers Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/kyoritsu/loop-psc-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/kyoritsu/loop-psc-testers/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Mon, 01 Jul 2024 07:34:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Loop / PSC Testers Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/kyoritsu/loop-psc-testers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Kyoritsu 6516 Multi Function Electrical Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-6516-multi-function-electrical-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 07 Oct 2020 03:30:16 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=60168</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2015/12/Kyoritsu_Logo_main.gif"><img class="alignnone size-full wp-image-27" src="https://obiat.com.au/wp-content/uploads/2015/12/Kyoritsu_Logo_main.gif" alt="" width="146" height="25" /></a></p>
<p>The KYORITSU 6516 &#38; 6516BT Multi-Function electrical testers have eight test functions in the one instrument.</p>
<ul>
<li>Continuity test</li>
<li>Insulation resistance test</li>
<li>Loop impedance test (High current measurement, No trip (ATT) measurement) 4 Prospective short circuit current test (On Loop impedance function)</li>
<li>RCD test</li>
<li>Voltage test</li>
<li>Phase rotation test 8 Earth test</li>
</ul>
<p>The Kyoritsu 6516 tester incorporates Anti Trip Technology (ATT) which electronically bypasses RCDs when performing loop impedance tests. This saves time and money by not having to take the RCD out of the circuit during testing and is a safer procedure to follow.</p>
<p>With the ATT function enabled, a test of 15mA or less is applied between line &#38; earth. It enables loop impedance measurements without tripping RCDs rated at 30mA and above.</p>
<p>ATT supports measurements using three wires: Line, Earth, and Neutral and also two wires: Line and Earth.</p>
<h3><strong>Also available is the <span style="text-decoration: underline;">Kyoritsu 6516BT with Bluetooth</span></strong></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-Datasheet.pdf" rel="noopener">Kyoritsu 6516-6516BT Datasheet</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2020/10/Kyoritsu-6516-6516BT-User-Manual.pdf" rel="noopener">Kyoritsu 6516-6516BT User Manual</a></span></h3>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-6516-multi-function-electrical-tester/">Kyoritsu 6516 Multi Function Electrical Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 6516 Multi Function Electrical Tester Features</h3>
<table style="height: 493px;" width="701">
<tbody>
<tr>
<td width="64"><strong><span style="font-size: 90%;">DISPLAY </span></strong></td>
<td width="571"><span style="font-size: 90%;">・Color LCD 3.5 inches dot matrix.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">ATT </span></strong></td>
<td><span style="font-size: 90%;">・Anti-Trip Technology (with 2 &amp; 3 wire) for no trip LOOP L-PE testing on all RCDs.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">LOOP </span></strong></td>
<td><span style="font-size: 90%;">・High test current range of 2Ω with 0.001Ω resolution.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・Zs Limit compares the values required by Electrical Installations Standard with measured results.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">RCD  </span></strong></td>
<td><span style="font-size: 90%;">・Type AC, A, F, B(General &amp; Selective), EV and Variable RCDs.</span></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 90%;">・Single and Auto test, Ramp test and Contact voltage.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">EARTH</span></strong></td>
<td><span style="font-size: 90%;">・Earth resistance test 2 and 3 wires with all accessories included.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">INSULATION </span></strong></td>
<td><span style="font-size: 90%;">・Resistance test 100, 250, 500 &amp; 1000V with auto discharge voltage.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">CONTINUITY</span></strong></td>
<td><span style="font-size: 90%;">・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">PHASE ROTATION </span></strong></td>
<td><span style="font-size: 90%;">・On 3-phase lines with clear indication of the sequence on the display.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">VOLTS </span></strong></td>
<td><span style="font-size: 90%;">・TRMS Voltage measurements 2-600V, Mains Frequency.</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;"><strong>HELP</strong>  </span></td>
<td><span style="font-size: 90%;">・Display shows how to connect the instrument according to the function selected.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">SPD  </span></strong></td>
<td><span style="font-size: 90%;"> ・Surge Protection Device test, for SPD that uses varistor.</span></td>
</tr>
<tr>
<td><strong><span style="font-size: 90%;">PAT </span></strong></td>
<td><span style="font-size: 90%;">・Portable Appliance Tester function, for Insulation &amp; Protective conductor resistance test</span></td>
</tr>
<tr>
<td><span style="font-size: 90%;"><strong>SAFETY </strong>  </span></td>
<td><span style="font-size: 90%;">・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,</span></td>
</tr>
</tbody>
</table>
<h3><a></a>Bluetooth communication</h3>
<p>Kyoritsu 6516BT has a Bluetooth communication function and can exchange data with Android/ iOS tablet devices.</p>
<p>Before starting to use this function, download the special application &#8220;KEW Smart *&#8221; via the internet.</p>
<h4 class="tm4">Large LCD &amp; HELP function</h4>
<ul>
<li>All the test data is shown in one large colored screen.</li>
<li>HELP function will show how to connect the instrument according to the function selected</li>
</ul>
<div class="row"  id="row-473873104">

	<div id="col-689482983" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img fetchpriority="high" decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516_HELP.png" alt="" width="350" height="260" /></p>
		</div>
					</div>

	

	<div id="col-1933659179" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516%20Large%20LCD.png" alt="" width="261" height="256" /></p>
		</div>
					</div>

	
</div>
<h4 class="tm4">Operation in 3 simple steps &amp; Hands free testing</h4>
<ol>
<li>Set the rotary dial to your testing range.</li>
<li>Connect the instrument to the installation under test.</li>
<li>Press the test button.(By remote probe or using the Lockdown function of the test button.)</li>
</ol>
<div class="row"  id="row-747381123">

	<div id="col-7975686" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="aligncenter" src="https://www.kew-ltd.co.jp/files/en/img/6516_123step.png" width="600" height="261" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">Anti-Trip Technology (with 2 &amp; 3 wire)</h4>
<p>For no trip LOOP L-PE testing on all RCDs.<br />
With 3 wire (L, N, PE), to get the best accuracy readings.<br />
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).</p>
<p>Loop Impedance 0.001 resolution</p>
<p>High test current range of 2Ω with 0.001Ω resolution.</p>
<p>Zs/Ra Limit</p>
<p>Zs Limit compares the values required by Electrical Installations Standard with measured results.</p>
<p>The verification of safety requirement on an electrical installation is simplified by using Zs/Ra Limit function. This function will automatically check if the measured loop impedance for TN (or earth loop for TT) is low enough to trip (disconnect) the MCB / Fuse / RCD giving the result of PASS or FAIL on the display.</p>
<div class="row"  id="row-2048961563">

	<div id="col-883744442" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_0001.png" width="250" height="186" align="right" /></p>
		</div>
					</div>

	

	<div id="col-804136955" class="col medium-1/2 large-6"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="alignright" src="https://www.kew-ltd.co.jp/files/en/img/6516_Zs%20table.png" width="260" height="171" align="right" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">SPD test</h4>
<p>SPD (Surge Protection Device) which contains varistor can be tested measuring the tripping voltage without damage it.<br />
<div class="row"  id="row-19547796">

	<div id="col-221995069" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_SPD.png" width="250" height="174" align="right" /></p>
		</div>
					</div>

	
</div>
<h5></h5>
<h5></h5>
<p>&nbsp;</p>
<h5></h5>
<h5></h5>
<h4 class="tm4">PAT test</h4>
<p>PAT test (PAT = Portable Appliance Tester) It is possible to check the insulation resistance and earth bond continuity of portable appliances for class I and II.</p>
<div class="row"  id="row-1437566267">

	<div id="col-210337870" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<img decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_PAT.1png.png" width="300" height="253" align="right" /></p>
		</div>
					</div>

	
</div>
<p>&nbsp;</p>
<h4 class="tm4">Connectivity</h4>
<p><strong>Use the PC application KEW Report to improve work efficiency.</strong></p>
<p>KYORITSU 6516 can download the test data by connecting the USB adaptor (Model 8212-USB) and then print complete Test Reports by a PC.<div class="row"  id="row-1921991759">

	<div id="col-269591639" class="col medium-1/1 large-12"  >
				<div class="col-inner"  >
			
			
<p><img decoding="async" class="alignleft" src="https://www.kew-ltd.co.jp/files/en/img/6516_PC.png" width="300" height="216" align="right" /></p>
<p><img decoding="async" src="https://www.kew-ltd.co.jp/files/en/img/6516BT_PC1.png" width="350" height="134" /></p>