<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Clampmeters Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/reed/clampmeters-reed/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/reed/clampmeters-reed/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Fri, 20 May 2016 04:46:08 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Clampmeters Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/reed/clampmeters-reed/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>REED R5040 True RMS AC/DC Clamp Meter with Temperature</title>
		<link>https://obiat.com.au/product/reed-r5040-true-rms-acdc-clamp-meter-temperature/</link>
					<comments>https://obiat.com.au/product/reed-r5040-true-rms-acdc-clamp-meter-temperature/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 24 Apr 2016 07:05:02 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2969</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The REED R5040 measures both  AC &#38; DC current (500-1000A), AC voltage (500mV-750V), and DC voltage (500mV-1000V). In addition, it also measures resistance and capacitance - as well as temperature, with the included Type K thermocouple probe.</p>
<h4>What's included with the REED R5040</h4>
<ul>
<li>R5040 1000A AC/DC True RMS Clamp Meter</li>
<li>Test Leads</li>
<li>Temperature Probe</li>
<li>9V Battery</li>
<li>Carrying Case</li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/04/r5040-manual.pdf" target="_blank" rel="">REED R5040 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2712" src="http://obiat.com.au/wp-content/uploads/2016/03/CAT-III-600V.jpg" alt="CAT III 600V" width="83" height="55" /></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="118" height="70" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-r5040-true-rms-acdc-clamp-meter-temperature/">REED R5040 True RMS AC/DC Clamp Meter with Temperature</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>REED R5040 Features</h4>
<ul class="gkCircle2">
<li>The REED R5040 measures AC and DC voltage and current, resistance,<br />
capacitance and frequency as well as temperature with<br />
the <strong>included type K thermocouple probe</strong></li>
<li>True RMS AC measurements</li>
<li>Diode and continuity test with beeper</li>
<li> Inrush current measurement</li>
<li>40,000-count digital display with 61-segment analogue bar graph and backlight</li>
<li>Max/Min and Relative (zero) functions</li>
<li>Data Hold function</li>
<li>Auto or manual ranging</li>
<li>Low battery indication and auto power-off</li>
<li>Double molded plastic housing</li>
<li>Conforms to EN61010 600V Cat. III</li>
<li>Includes test leads, temperature probe, 9V battery and<br />
carrying case</li>
</ul>
<h4>REED R5040 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td colspan="2"><strong>AC/DC Current</strong></td>
</tr>
<tr>
<td>Range</td>
<td>500.00, 1000.0A</td>
</tr>
<tr>
<td>Accuracy</td>
<td>AC: ±(2.8% rdg. +30 dgt.)<br />
DC: ±(2.5% rdg. +30 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>AC/DC Voltage</strong></td>
</tr>
<tr>
<td>Range</td>
<td>AC: 500.00mV, 5.000, 50.00, 500.0, 750.0V<br />
DC: 500.00mV, 5.000, 50.00, 500.0, 1000.0V</td>
</tr>
<tr>
<td>Accuracy</td>
<td>AC: ±(1.0% rdg. +30 dgt.)<br />
DC: ±(0.1% rdg. +4 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>Resistance</strong></td>
</tr>
<tr>
<td>Range</td>
<td>500.00Ω, 5.000, 50.00, 500.0kΩ, 5.000, 50.00MΩ</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.0% rdg. +4 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>Capacitance</strong></td>
</tr>
<tr>
<td>Range</td>
<td>500.00, 5000.0nF, 50.00, 500.0µF, 5.000mF</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(3.5% rdg. +10 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>Frequency</strong></td>
</tr>
<tr>
<td>Range</td>
<td>10.000kHz</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(0.3% rdg. +2 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>Temperature</strong></td>
</tr>
<tr>
<td>Range</td>
<td>-100.0 to 1000.0°C (-148.0 to 1832.0°F)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.0% rdg. +2.5°C (4.5°F))</td>
</tr>
<tr>
<td colspan="2"><strong>General Specifications</strong></td>
</tr>
<tr>
<td>Jaw Opening</td>
<td>40mm (1.5&#8243;)</td>
</tr>
<tr>
<td>Power Supply</td>
<td>Single 9V battery</td>
</tr>
<tr>
<td>Dimensions</td>
<td>232 x 77 x 39mm</td>
</tr>
<tr>
<td>Weight</td>
<td>315g</td>
</tr>
</tbody>
</table>
<h4>What&#8217;s included with the REED R5040</h4>
<ul>
<li>R5040 1000A AC/DC True RMS Clamp Meter</li>
<li>Test Leads</li>
<li>Temperature Probe</li>
<li>9V Battery</li>
<li>Carrying Case</li>
</ul>
<p>The post <a href="https://obiat.com.au/product/reed-r5040-true-rms-acdc-clamp-meter-temperature/">REED R5040 True RMS AC/DC Clamp Meter with Temperature</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r5040-true-rms-acdc-clamp-meter-temperature/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>REED R5020 400 Amp AC/DC Clamp Meter with Temperature Probe</title>
		<link>https://obiat.com.au/product/reed-r5020-400-amp-acdc-clamp-meter-temperature-probe/</link>
					<comments>https://obiat.com.au/product/reed-r5020-400-amp-acdc-clamp-meter-temperature-probe/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 Mar 2016 00:04:41 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1879</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>Reed R5020 AC Clamp Meter is a digital clamp on meter that can made Non-Contact AC Voltage Measurements up to 400A, voltage measuremements up to 600V, resistance, Diode and Continuity, Frequency or % Duty Cycle. with the included Type K thermocouple probe you can also use this meter for temperature measurements</p>
<p>REED R5020 Features</p>
<ul class="gkCircle2">
<li>Measures AC current, AC and DC voltage, resistance, capacitance,<br />
and temperature with the included Type K thermocouple probe</li>
<li>Diode test and continuity check;</li>
<li>Data hold, Zero Function, and Auto Power Off;</li>
<li>4000-count LCD displays low battery and over-range indications;</li>
<li>Cat. III 600V safety rating &#38; UL approved</li>
</ul>
<p><strong> Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-1363" src="http://obiat.com.au/wp-content/uploads/2016/03/ul-logo-black-2.png" alt="UL" width="42" height="42" />    <img class="alignnone wp-image-2712" src="http://obiat.com.au/wp-content/uploads/2016/03/CAT-III-600V.jpg" alt="CAT III 600V" width="70" height="46" /></p>
<p><img class="alignnone  wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="142" height="84" /></p>
<p><a href="https://www.youtube.com/watch?v=F6CZYujoZi8&#38;nohtml5=False" target="_blank"> <img class="alignnone wp-image-2707" src="http://obiat.com.au/wp-content/uploads/2016/02/VIDEO-3.jpg" alt="VIDEO" width="147" height="82" /><img class="alignnone wp-image-1648" src="http://obiat.com.au/wp-content/uploads/2016/02/Play.jpg" alt="Play" width="90" height="67" /></a></p>
<p>The post <a href="https://obiat.com.au/product/reed-r5020-400-amp-acdc-clamp-meter-temperature-probe/">REED R5020 400 Amp AC/DC Clamp Meter with Temperature Probe</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use REED R5020 AC Clamp Meter</h4>
<p><strong>Data Hold</strong><br />
While taking a measurement, press the Data Hold button to freeze the display. The HOLD indicator will also appear on the display. Press the Hold button again to resume measuring.</p>
<p><strong>AC Current Measurements with REED R5020</strong><br />
Start using the REED R5020 and set the function switch to the 400 or 40A range. If the range needed is not known, select the higher range first then move to the lower range if necessary. Open the instrument&#8217;s jaw by pressing the trigger. Now just fully enclose one conductor and the R5020&#8217;s LCD will display the reading.</p>
<p><strong>AC/DC Voltage Measurements</strong><br />
For voltage measurements you need to insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. Using the instrument rotation switch, choose V position, and depends on your measurements, select either AC or DC with the MODE button. Connect the test leads in parallel to the circuit under test. The LCD will display the reading.</p>
<p><strong>Resistance Measurements with R5020 clamp meter</strong><br />
Make resistance measurements with our R5020 Reed Clamp Meter. Firstly, insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. Secondly, choose the Ω (ohm) position using the rotary switch. Now you can touch the test probe tips across the circuit or component under test. The rest of the circuit will not interfere with reading if you will disconnect one side of the device under the test. Read the measurements value on the instrument LCD display.</p>
<p><strong>Diode and Continuity Measurements</strong><br />
For using this Reed R5020 instrument into Diode and Continuity electrical tests, first think you have to do is to connect the test lead correctly as following: the black test lead into the negative COM terminal and the red test lead into the positive V diode terminal. Turn the rotary switch to the Ω position and press the MODE button until the Diode Test indicator appears on the display. Touch the test probes to the diode under test. Forward voltage will indicate 0.4V to 0.7V. Reverse voltage will be indicated by “OL”. Shorted devices will indicate near 0mV and an open device will be indicated by “OL” in both polarities. For Continuity tests, if the resistance is &lt; 150, a tone will sound.</p>
<p><strong>Capacitance Measurements</strong><br />
Even if this R5020 was designed to work as clamp meter, the instrument can made Capacitance Measurements with precision and accuracy results. Same as any multimeter, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements, remove the batteries and unplug the line cords. Using the R5020&#8217;s rotary function, switch to the CAP position. Connect the test leads as following: black test lead into the negative COM terminal and the red test lead into the positive V terminal. Touch the test leads to the capacitor to be tested and read the capacitance value on the display.</p>
<p><strong>Frequency or % Duty Cycle measurements</strong><br />
The R5020 Clamp on meter must be used correctly to assure accuracy of the any frequency or % duty cycle measurements. The most important is to set the rotary function switch to the V position. Connect the black test lead into the negative COM terminal and the red test lead into the positive V terminal. Select Hz or % duty with the Hz/% button. Touch the test probe tips to the circuit under test. Read the frequency value on the display.</p>
<p><strong>Temperature Measurements</strong><br />
One of the most great feature of this Clamp meter is that you can made also temperature measurements. For this kind of tests and to avoid electric shock, disconnect both test probes from any source of voltage before making a temperature measurement. Set the function switch to °C or °F and insert the Temperature Probe into the negative COM and the positive V terminals, making sure to observe the correct polarity.Touch the Temperature Probe head to the area to be measured. Keep the probe touching the part under test until the reading stabilizes (about 30 seconds). Read the temperature value on the display. To avoid electric shock, be sure the thermocouple has been removed before changing to another function.</p>
<p><strong>Non-Contact AC Voltage </strong><b>Measurement</b></p>
<p>Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. If AC voltage is present, the detector will light up. The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor. The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor.</p>
<h4>REED R5020 Specifications</h4>
<ul class="gkCircle2">
<li>AC Current Range: 40.00, 400.0A</li>
<li>AC Current Accuracy: ±(2.5% rdg. + 8 dgt.)</li>
<li>DC Voltage Range: 400.0mV, 4.000, 40.00, 400.0, 600.0V</li>
<li>DC Voltage Accuracy: ±(1.5% rdg. + 2 dgt.)</li>
<li>AC Voltage Range: 4.000, 40.00, 400.0, 600.0V</li>
<li>AC Voltage Accuracy: ±(1.8% rdg. + 8 dgt.)</li>
<li>Resistance Range: 400.0Ω, 4.000, 40.00, 400.0kΩ, 4.000, 40.00MΩ</li>
<li>Resistance Accuracy: ±(1.5% rdg. + 2 dgt.)</li>
<li>Capacitance Range: 40.00, 400.0nF, 4.000, 40.00, 100.0μF</li>
<li>Capacitance Accuracy: ±(3% rdg. + 5 dgt.)</li>
<li>Temperature Range: -20.0 to 760.0°C (-4.0 to 1400.0°F)</li>
<li>Temperature Accuracy: ±(3% rdg. + 5°C/9°F)</li>
<li>Diode Test: Test current of 0.3mA typical;</li>
<li>Open circuit voltage 1.5V DC typical</li>
<li>Continuity Check: Threshold &lt;150Ω; Test current &lt;0.5mA</li>
<li>Jaw Opening: 1.2” (30mm) maximum</li>
<li>Power Supply: 2 x 1.5V “AAA” batteries</li>
<li>Dimensions: 200 x 66 x 37mm</li>
<li>Weight: 205g</li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/reed-r5020-400-amp-acdc-clamp-meter-temperature-probe/">REED R5020 400 Amp AC/DC Clamp Meter with Temperature Probe</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r5020-400-amp-acdc-clamp-meter-temperature-probe/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed CM-9930 AC/DC 2000A True-Rms Clamp Meter</title>
		<link>https://obiat.com.au/product/reed-cm-9930-acdc-2000a-true-rms-clamp-meter/</link>
					<comments>https://obiat.com.au/product/reed-cm-9930-acdc-2000a-true-rms-clamp-meter/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:44 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-cm-9930-acdc-2000a-true-rms-clamp-meter/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The Reed CM-9930 delivers safety, durability and assures excellent performance and accuracy for a large kind of measurements: AC or DC current tests, resistance, made continuity Check or Diode Test, Capacitance tests or frequency measurements. This Reed non-contact voltage detector has 0.35 seconds sampling rate and provides overload protection for all ranges.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="118" height="70" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-cm-9930-acdc-2000a-true-rms-clamp-meter/">Reed CM-9930 AC/DC 2000A True-Rms Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Reed CM-9930 Features:</strong></p>
<ul>
<li>Full function autoranging digital multimeter includes AC/DC voltage, and current, resistance, capacitance, frequency, duty cycle, diode and continuity</li>
<li>True RMS measurements</li>
<li>Current measurements to 2000A through the clamp and 240mA via the test leads</li>
<li>Large 4000-count backlit display</li>
<li>Basic VDC accuracy of 1% with 0.1mV resolution and current resolution to 0.1µA</li>
<li>2.36&#8243; (60mm) clamp jaw opening (750MCM)</li>
<li>DC current push button zero, relative measurements and data hold</li>
<li>Heavy duty ABS case with built-in stand and thumb control switch</li>
<li><span style="color: #ff0000;"><strong>IEC1010 Cat. III 1000V Safety Rating</strong></span></li>
</ul>
<h4 class="title">How to use the Reed CM-9930 Digital Clampmeter:</h4>
<p><strong>DC/AC Measurements with Reed CM-9930</strong><br />
Firstly, connect the Black test lead into the COM terminal and the Red one into the V terminal. Using the function rotary switch select the desired function ( V position) and press the function button until display shows the corresponding AC or DC icon. Read the values on the CM-9930&#8217;s LCD display</p>
<p>If you&#8217;re going to <strong>measure resistance, made continuity Check or Diode Test, Capacitance tests or Frequency Measurements</strong>, with Reed CM-9930 you can do standard measurements as an any other multimeters. The procedure is quite similar, not complicated and safe.</p>
<p><strong>AC or DC Current Measurements (Clamp-on)</strong><br />
If you&#8217;re going to measure AC voltage move the function rotary switch to the 2000A position and press the function button till the display shows . Press the trigger to open the current sensor jaws and clamp it around the measuring conductor only. For DC current measurements move the function rotary switch to the 2000A position and press the function button until the display shows the corresponding DC icon. Push the DCA Zero button for at least 2 seconds to display a value of zero. Press the trigger to open the current sensor jaws and clamp it around the measuring conductor only.</p>
<p><strong>AC or DC Current Measurement (Direct input)</strong><br />
To measure AC or DC Current with direct input procedure, you normally have to insert the lead test into the instrument as follow: Black test lead into the COM terminal and Red test lead into the uA, mA terminal. If measuring uA (400uA, 4000uA), move the function rotary switch to the uA position and press the function button until the display shows AC or DC icon (according with your measurements type) If measuring mA (40mA, 400mA), move the function rotary switch to the mA position and press the function button until the display shows AC or DC icon (according with your measurements type) Open the circuit where the current to be measured is located and securely connect the test lead in series with the circuit.</p>
<h4 align="left">Reed CM-9930 Specifications:</h4>
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#FFFFFF">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">Measurement</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">Range</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">AC Current</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">240A, 2000.0A</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">DC Current</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">240µA, 240mA</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">AC Voltage</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">2.4V to 1000V</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">DC Voltage</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">2.4mV to 1000V</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">Resistance</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">240Ω, to 24MΩ</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">Capacitance</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">25nF, to 25µF</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">Frequency</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">50Hz, to 100kHz</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="236"><span style="color: #fcfafa;">Clamp Jaw Opening</span></td>
<td bgcolor="#3C809F" width="551"><span style="color: #fcfafa;">60mm</span></td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="3" bgcolor="#FFFFFF"><strong>General Specifications</strong></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="30%"><span style="color: #fcfafa;">Power Supply</span></td>
<td colspan="2" bgcolor="#3C809F" width="70%"><span style="color: #fcfafa;">2 type &#8216;AA&#8217;  Alkaline batteries</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="30%"><span style="color: #fcfafa;">Dimensions</span></td>
<td colspan="2" bgcolor="#3C809F" width="70%"><span style="color: #fcfafa;">255mm (L) x 74mm (W) x 38mm (D)</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="30%"><span style="color: #fcfafa;">Weight</span></td>
<td colspan="2" bgcolor="#3C809F" width="70%"><span style="color: #fcfafa;">400g approx.</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/reed-cm-9930-acdc-2000a-true-rms-clamp-meter/">Reed CM-9930 AC/DC 2000A True-Rms Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-cm-9930-acdc-2000a-true-rms-clamp-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed C-212 AC/DC 1000A True-Rms Clamp Meter</title>
		<link>https://obiat.com.au/product/reed-c-212-acdc-1000a-true-rms-clamp-meter/</link>
					<comments>https://obiat.com.au/product/reed-c-212-acdc-1000a-true-rms-clamp-meter/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:44 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-c-212-acdc-1000a-true-rms-clamp-meter/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The Reed C-212 True RMS Clamp Meter, you can measure current up to 1000A and voltage up to 750/1000V (ACV/DCV). Thanks to the polarity and overload indications, the measurements are very easy, safe and fast.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="118" height="70" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-c-212-acdc-1000a-true-rms-clamp-meter/">Reed C-212 AC/DC 1000A True-Rms Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">Reed C-212True RMS Clamp Meter</h4>
<p><strong>AC/DC Current Measurements</strong><br />
Before all you have to select AC or DC function by pressing the “AC/DC” button Once completed, insert the cable to be measured into the jaw and read the value on the LCD display.</p>
<p><strong>AC/DC Voltage measurements</strong><br />
Switch the Reed C-212&#8217;s main function selector as way to selecct the Voltage Range. Now conect the tests leads, red one to the &#8220;+&#8221; terminal and black one to the COM jack. Choose AC or DC by pressing the AC/DC button. Measure the voltage by touching the test lead tips to the test circuit where the value of voltage is needed. Read the result on the LCD panel.</p>
<p><strong>AC/DC Voltage measurements</strong><br />
Switch the Reed C-212&#8217;s main function selector as way to select the Voltage Range. Now connect the tests leads, red one to the Reed clamp meter&#8217;s &#8220;+&#8221; terminal and black one to the COM jack. Choose AC or DC by pressing the AC/DC button. Measure the voltage by touching the test lead tips to the test circuit where the value of voltage is needed. Read the result on the LCD panel.</p>
<p><strong>Resistance measurements, Continuity Test or Diode Test</strong> are an uncomplicated and easy to made. The main step is to select the function by the Function switch. After that step, connect the test leads and start measuring.</p>
<p><strong>Frequency measurements from the terminals</strong><br />
Switch the main function to the “Hz” range. Connect the Red test lead to the &#8220;+&#8221; terminal and the Black one to the &#8220;COM&#8221;. Connect the tips of the test leads to the points where the frequency of the voltage signal is required. Read the value one the LCD panel.</p>
<p><strong>Frequency measurement with the clamp</strong><br />
You can made frequency measurement without touching the wires. Start the test by switching the main function to the “Hz” range. Open the clamp by pressing the clamp-opening handle and insert the cable to be measured into the clamp. Close the clamp and you will find the reading on the LCD panel.</p>
<h4>REED C-212 Features</h4>
<ul class="gkCircle2">
<li>True RMS measurements</li>
<li>3-3/4 digit LCD with high-speed, 42-segment bargraph</li>
<li>Max/Min and Data Hold functions</li>
<li>Peak Hold function</li>
<li>Frequency measurement</li>
<li>Diode and continuity test with beeper</li>
<li>Polarity and overload indications</li>
<li>Auto or manual ranging</li>
<li>Auto power-off</li>
<li>Low battery indication</li>
</ul>
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" align="center" width="100%">
<h4 align="left"><span style="font-size: medium;">Reed C-212 Specifications:</span></h4>
</td>
</tr>
<tr>
<td colspan="2" align="center" width="100%">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#FFFFFF">
<div align="center">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#876B8B" width="244"><span style="color: #ffffff; font-size: medium;">Measurement</span></td>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff; font-size: medium;">Range</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff; font-size: medium;">Resolution</span></td>
<td bgcolor="#3C809F" width="236"><span style="color: #ffffff; font-size: medium;">Accuracy</span></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#876B8B" width="244"><span style="color: #ffffff;">AC Voltage</span></td>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">400V</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">0.1V</span></td>
<td rowspan="2" bgcolor="#3C809F" width="236"><span style="color: #ffffff; font-family: Verdana;">±(1.5% of reading +5 dgt)</span></td>
</tr>
<tr>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">750V</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">1V</span></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#876B8B" width="244"><span style="color: #ffffff;">DC Voltage</span></td>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">400V</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">0.1V</span></td>
<td rowspan="2" bgcolor="#3C809F" width="236"><span style="color: #ffffff; font-family: Verdana;">±(1% of reading +2 dgt)</span></td>
</tr>
<tr>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">1000V</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">1V</span></td>
</tr>
<tr>
<td rowspan="3" valign="top" bgcolor="#876B8B" width="244"><span style="color: #ffffff;">AC Current</span></td>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">40A</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">0.01A</span></td>
<td rowspan="3" bgcolor="#3C809F" width="236"><span style="color: #ffffff; font-family: Verdana;">±(1.9% of reading +5 dgt)</span></td>
</tr>
<tr>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">400A</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">0.1A</span></td>
</tr>
<tr>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">1000A</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">1A</span></td>
</tr>
<tr>
<td rowspan="3" valign="top" bgcolor="#876B8B" width="244"><span style="color: #ffffff;">DC Current</span></td>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">40A</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">0.01A</span></td>
<td rowspan="3" bgcolor="#3C809F" width="236"><span style="color: #ffffff; font-family: Verdana;">±(2.5% of reading +10 dgt)</span></td>
</tr>
<tr>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">400A</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">0.1A</span></td>
</tr>
<tr>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">1000A</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">1A</span></td>
</tr>
<tr>
<td rowspan="2" bgcolor="#876B8B" width="244"><span style="color: #ffffff;">Resistance</span></td>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">400<span style="font-family: Verdana;">Ω,</span></span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">0.1<span style="font-family: Verdana;">Ω</span></span></td>
<td rowspan="2" bgcolor="#3C809F" width="236"><span style="color: #ffffff; font-family: Verdana;">±(1% of reading +3 dgt)</span></td>
</tr>
<tr>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">400<span style="font-family: Verdana;">0Ω,</span></span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">1<span style="font-family: Verdana;">Ω</span></span></td>
</tr>
<tr>
<td rowspan="2" bgcolor="#876B8B" width="244"><span style="color: #ffffff;">Frequency</span></td>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">4Hz</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">1Hz</span></td>
<td rowspan="2" bgcolor="#3C809F" width="236"><span style="color: #ffffff; font-family: Verdana;">±(0.1% of reading +1 dgt)</span></td>
</tr>
<tr>
<td bgcolor="#3C809F" width="184"><span style="color: #ffffff;">10kHz</span></td>
<td bgcolor="#3C809F" width="121"><span style="color: #ffffff;">10Hz</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="244"><span style="color: #ffffff;">Jaw Opening</span></td>
<td colspan="3" bgcolor="#3C809F" width="541"><span style="color: #ffffff;">40mm</span></td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2" align="center" width="100%"></td>
</tr>
<tr>
<td colspan="2" align="center" width="100%">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="3" bgcolor="#FFFFFF"><span style="font-size: medium;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="30%"><span style="color: #ffffff;">Power Supply</span></td>
<td colspan="2" bgcolor="#3C809F" width="70%"><span style="color: #ffffff;">9-Volt Alkaline battery</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="30%"><span style="color: #ffffff;">Dimensions</span></td>
<td colspan="2" bgcolor="#3C809F" width="70%"><span style="color: #ffffff;">242mm (L) x 66mm (W) x 36mm (D)</span></td>
</tr>
<tr>
<td bgcolor="#876B8B" width="30%"><span style="color: #ffffff;">Weight</span></td>
<td colspan="2" bgcolor="#3C809F" width="70%"><span style="color: #ffffff;">400g</span></td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/reed-c-212-acdc-1000a-true-rms-clamp-meter/">Reed C-212 AC/DC 1000A True-Rms Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-c-212-acdc-1000a-true-rms-clamp-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>REED R5030 AC/DC True RMS Clamp Meter</title>
		<link>https://obiat.com.au/product/reed-r5030-acdc-true-rms-clamp-meter/</link>
					<comments>https://obiat.com.au/product/reed-r5030-acdc-true-rms-clamp-meter/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:44 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-r5030-acdc-true-rms-clamp-meter/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The Reed R5030 is able to measure AC/DC current, AC/DC voltage, resistance, capacitance, frequency, duty cycle, and temperature with a type K thermocouple probe.</p>
<h4>REED R5030 Features</h4>
<ul class="gkCircle2">
<li>Measures AC/DC current, AC/DC voltage, resistance, capacitance, frequency, duty cycle, and temperature with a type K thermocouple probe</li>
<li>True RMS AC measurements</li>
<li>Non-contact AC voltage detector in clamp tip</li>
<li>Max/Min, Data hold and Relative functions</li>
<li>Low battery indication and auto power-off</li>
<li>50,000 count LCD with backlight</li>
<li>Conforms to EN61010 Cat. III 600V</li>
</ul>
<p><a href="http://obiat.com.au/wp-content/uploads/2016/02/r5030-datasheet.pdf"><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" /></a>    <a href="http://obiat.com.au/wp-content/uploads/2016/02/r5030-datasheet.pdf" target="_blank">Reed R5030 Datasheet</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="118" height="70" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-r5030-acdc-true-rms-clamp-meter/">REED R5030 AC/DC True RMS Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>REED R5030 AC/DC True RMS Clamp Meter</h4>
<p>With a non-contact AC voltage detector in it&#8217;s clamp tip the Reed R5030 clamp meter becomes a quick and versatile diagnostic tool for finding out why an electrical system or piece of electrical equipment is not operating correctly.</p>
<p>Applications for the REED R5030</p>
<ul>
<li>Industrial maintenance technicians</li>
<li>Control technicians</li>
<li>Electricians</li>
<li>Facilities</li>
<li>Building maintenance and HVAC technicians</li>
<li>Repairing existing systems on an as-needed basis</li>
<li>Troubleshoot installation problems</li>
<li>Perform final circuit tests</li>
<li>Perform scheduled and preventive maintenance on electro-mechanical and electrical systems</li>
<li>Industrial equipment and controls</li>
<li>Commercial/industrial HVAC systems</li>
</ul>
<table>
<tbody>
<tr>
<td colspan="2"><strong> AC/DC Current Clampmeter</strong></td>
</tr>
<tr>
<td>Range</td>
<td>50.00, 500.0A</td>
</tr>
<tr>
<td>Accuracy</td>
<td>AC: ±(2.8% rdg. +30 dgt.)<br />
DC: ±(2.5% rdg. +30 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong> AC/DC Voltage</strong></td>
</tr>
<tr>
<td>Range</td>
<td>AC: 500.00mV, 5.0000, 50.000, 500.00, 750.0V<br />
DC: 500.00mV, 5.0000, 50.000, 500.00, 1000.0V</td>
</tr>
<tr>
<td>Accuracy</td>
<td>AC: ±(1.0% rdg. +30 dgt.)<br />
DC: ±(0.1% rdg. +4 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong> Resistance</strong></td>
</tr>
<tr>
<td>Range</td>
<td>500.00Ω, 5.000, 50.000, 500.00kΩ, 5.0000, 50.000MΩ</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.0% rdg. +4 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong> Frequency</strong></td>
</tr>
<tr>
<td>Range</td>
<td>10.000kHz</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(0.5% rdg. +10 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong> Capacitance</strong></td>
</tr>
<tr>
<td>Range</td>
<td>500.00, 5000.0nF, 50.00, 500.0µF, 5.000mF</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(3.5% rdg. +10 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong> Temperature</strong></td>
</tr>
<tr>
<td>Range</td>
<td>-100.0 to 1000.0°C/-148.0 to 1832.0°F</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.0% rdg. +2.5°C/4.5°F)</td>
</tr>
<tr>
<td colspan="2"><strong> General Specifications</strong></td>
</tr>
<tr>
<td>Display</td>
<td>50,000 count LCD</td>
</tr>
<tr>
<td>Power Supply</td>
<td>Two AAA 1.5V batteries</td>
</tr>
<tr>
<td>Jaw Opening</td>
<td>30mm</td>
</tr>
<tr>
<td>Dimensions</td>
<td>198 x 66 x 36mm</td>
</tr>
<tr>
<td>Weight</td>
<td>230g</td>
</tr>
</tbody>
</table>
<p><strong>What&#8217;s included with the REED R5030</strong></p>
<ul>
<li>R5030 500A AC/DC True RMS Clamp Meter</li>
<li>Set of Test Leads</li>
<li>Temperature Probe</li>
<li>Batteries</li>
<li>Soft Carrying Case</li>
</ul>
<p>Battery Replacement</p>
<p>1. Remove the Phillips screw on the back of the meter</p>
<p>2. Open the battery compartment</p>
<p>3. Replace the dead batteries and close the battery compartment</p>
<p>Safety</p>
<p>• Do not exceed the maximum allowable input range of any function</p>
<p>• Do not apply voltage to the meter when resistance function is selected</p>
<p>• Set the function switch OFF when the meter is not in use Warning</p>
<p>• Set the function switch to the appropriate position before measuring</p>
<p>• When measuring volts do not switch to current/resistance modes</p>
<p>• When changing ranges using the selector switch always disconnect the test leads from the circuit under test</p>
<p>• Do not exceed the maximum rated input limits</p>
<p>The post <a href="https://obiat.com.au/product/reed-r5030-acdc-true-rms-clamp-meter/">REED R5030 AC/DC True RMS Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r5030-acdc-true-rms-clamp-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
