<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Industrial Maintenance Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/reed/industrial-maintenance/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/reed/industrial-maintenance/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Tue, 02 Jul 2024 07:57:08 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Industrial Maintenance Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/reed/industrial-maintenance/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Reed R9700 Battery Coolant Refractometer</title>
		<link>https://obiat.com.au/product/reed-r9700-battery-coolant-checkerrefractometer/</link>
					<comments>https://obiat.com.au/product/reed-r9700-battery-coolant-checkerrefractometer/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 22 Apr 2016 10:54:00 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2939</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>Monitor the freezing point of both Ethylene Glycol and Propylene Glycol with the REED R9700 coolant checker.</p>
<h4><span class="manufacturer">REED R9700 </span>Features</h4>
<ul class="gkCircle2">
<li>Propylene and Ethylene Glycol Measuring Range: -50 to 0°C</li>
<li>Minimum Scale Division: 5°C</li>
<li>Automatic Temperature Compensation Range: 10 to 30°C</li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" /> <a href="http://obiat.com.au/wp-content/uploads/2016/04/r9700-manual.pdf" target="_blank" rel="">Reed R9700 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="106" height="63" /></p>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/reed-r9700-battery-coolant-checkerrefractometer/">Reed R9700 Battery Coolant Refractometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Use the Reed R9700 Battery Coolant Checker for the following:</h4>
<ul class="gkCircle2">
<li>It is essential to know the concentration and freezing point of anti-freeze coolants for vehicular safety</li>
<li>Keeping a suitable concentration of coolant prevents engine trouble and possible radiator corrosion</li>
<li>This tester monitors the freezing point of both Ethylene Glycol and Propylene Glycol in addition, it indicates battery recharge level</li>
<li>This tester is simple to use; requiring only a few drops to provide accurate readings within seconds</li>
<li>It is virtually indispensable for gas stations, service shops, cab companies, etc.</li>
</ul>
<h4>REED R9700 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td>Propylene and Ethylene Glycol Measuring Range</td>
<td>-50 to 0°C</td>
</tr>
<tr>
<td>Minimum Scale Division</td>
<td>5°C</td>
</tr>
<tr>
<td>Automatic Temperature Compensation Range</td>
<td>10 to 30°C</td>
</tr>
</tbody>
</table>
<h4>REED R9700 Calibration</h4>
<p>1. Open the cover plate and place 2-3 drops of distilled water onto the prism surface, close the cover plate, press lightly and ensure the water spreads evenly across the whole surface area without air bubbles or dry sections. (wait 30 seconds until the water adjusts to ambient temperature)</p>
<p>2. Hold towards light source and look into the eyepiece, if the boundary line between the upper blue field and the lower white field is not located exactly on the 0°C waterline, adjust the correcting screw until both lines meet.</p>
<p>3. Wipe the water from the prism with clean dry cloth and replace the rubber correcting screw cover.</p>
<p>NOTE: under normal operating conditions the calibration only needs to be checked periodically.</p>
<h4>Warning</h4>
<p>1. DO NOT IMMERSE IN OR CLEAN WITH RUNNING WATER</p>
<p>2. THIS TOOL IS A PRECISON OPTICAL INSTRUMENT, IT REQUIRES CAREFULL HANDLING and STORAGE</p>
<p>3. DO NOT DROP OR SUBJECT TO SHOCK AS DAMAGE MAY RESULT TO THE MIRROR TUBE and OPTICAL COMPONENTS</p>
<p>4. DO NOT SCRATCH OR ATTEMPT TO MEASURE CORROSIVE CHEMICALS AS DAMAGE MAY OCCUR TO THE PRISM’S COATING</p>
<p>CAUTION – use extreme care when opening the radiator cap – do not remove while engine is running or the engine is warm. Do not let battery fluid come in contact with skin or eyes – personal injury may result</p>
<p>The post <a href="https://obiat.com.au/product/reed-r9700-battery-coolant-checkerrefractometer/">Reed R9700 Battery Coolant Refractometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r9700-battery-coolant-checkerrefractometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>REED SD-8205 Vibration Meter &#038; Data Logger</title>
		<link>https://obiat.com.au/product/reed-sd-8205-vibration-meter-data-logger/</link>
					<comments>https://obiat.com.au/product/reed-sd-8205-vibration-meter-data-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 10 Mar 2016 05:36:26 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1548</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>With it's custom microprocessor LSI circuit, the Reed SD-8205 Data Hold Vibration Meter is a perfect digital vibration meter for measuring vibrations easily, basing on separate vibration probe with magnetic base. Root Means Square (RMS) value. Max Hold measures and updates the max. peak value. Peak measures the peak vibration value.</p>
<p><strong>REED SD-8205 Features</strong></p>
<ul class="gkCircle2">
<li>Frequency range meets ISO 2954 standards</li>
<li>Metric &#38; Imperial display units</li>
<li>Separate vibration probe with magnetic base</li>
<li>Measures Velocity &#38; Acceleration</li>
<li>RMS, Peak, &#38; Max Hold functions</li>
<li>Real time SD memory card datalogger with a built-in clock and calendar</li>
<li>Sampling time set from 1 second to 3600 seconds</li>
<li>Meter can switch to a Manual Datalogging</li>
<li>No extra software needed, just plug the SD card into the computer and it downloads directly to EXCEL</li>
<li>SD card capacity: 1 GB to 16 GB</li>
<li>Easy to read LCD with backlight</li>
<li>Auto power off or manual power off</li>
<li>Data hold, record max. and min. reading</li>
<li>High accuracy microcomputer circuit</li>
<li>Power by UM3/AA (1.5 V) x 6 batteries</li>
<li>USB/RS232 Computer interface</li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />  <a href="http://obiat.com.au/wp-content/uploads/2016/03/sd-8205-manual.pdf" target="_blank" rel="">REED SD-8205 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="132" height="78" /></p>
<p><a href="https://www.youtube.com/watch?v=cHhLAITjeC4&#38;nohtml5=False" target="_blank"><img class="alignnone wp-image-2707" src="http://obiat.com.au/wp-content/uploads/2016/02/VIDEO-3.jpg" alt="VIDEO" width="186" height="104" /> <img class="alignnone wp-image-1648" src="http://obiat.com.au/wp-content/uploads/2016/02/Play.jpg" alt="Play" width="75" height="56" /></a></p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-8205-vibration-meter-data-logger/">REED SD-8205 Vibration Meter &#038; Data Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use Reed Data Hold Vibration Meter (SD-8205)</h4>
<p>Connect the BNC Cable into the BNC Vibration Meter&#8217;s Socket, and the Mini Cable Plug into the Vibration Sensor Socket. Choose the desired function from from: RMS, Peak, and Max Hold. RMS measures and Root Means Square (RMS) value. Max Hold measures and updates the max. peak value. Peak measures the peak vibration value. For Acceleration and Velocity measurement, always select RMS measurement. The selected function will be saved as the default.</p>
<p><strong>Zero Adjustment</strong><br />
For zero adjustment operation is necessary that the Vibration Sensor to be connected to the Data Hold Vibration Meter via the Vibration Sensor Socket. Now you are able to select Acceleration measurement (m/s2, g, ft/s2). Keep the vibration sensor motionless. Be sure there is no signal being picked up. Press and hold the Logger Button for at least 5 seconds. The screen will display a zero value. The Zero Adjustment can be executed only when the measured value is less than 10 digits.</p>
<p><strong>Max hold reset procedures</strong><br />
With your instrument into the Max Hold function, press and hold the Logger Button for at least 5 seconds to clear the existing Max hold value.</p>
<p><strong>Data Hold</strong><br />
While taking any vibration measurement, press the Hold Button once and the measured value will hold on the screen, and a HOLD symbol will appear. Press the Hold Button once again will release the data hold function.</p>
<p><strong>Data Record (Max., Min. reading)</strong><br />
The Reed Data Hold Vibration Meter (SD-8205) are able to record the maximum and minimum readings via Data record function. Press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. To delete the maximum value, press the Hold Button once and the display will show a “REC.” symbol only and execute the memory function continuously. Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display. To delete the minimum value, press the Hold Button once, and the display will show a “REC.” symbol only and execute the memory function continuously.</p>
<p><strong>Auto Datalogger (Set sampling time ≥1 second)</strong><br />
1) Start Datalogging; press the REC Button, and the “REC” symbol will appear on the SD-8205&#8217;s LCD screen, then press the Logger Button, the “REC” symbol will flash while the measuring data and time information is being saved in memory.To set the sampling time, and to toggle the beeper sound on or off, refer to the Advanced Settings section of this manual.<br />
2) Pause the Datalogging; while Datalogging, if press the Logger Button once. While paused, the “REC” symbol will stop flashing. Press the Logger Button again to resume Datalogging, and the “REC” symbol will begin to flash again.<br />
3) Stop Datalogging; while the Datalogger function is paused, press the REC Button for 2 seconds. The “REC” symbol will disappear indicating the Datalogging function has stopped.</p>
<p><strong>Manual Datalogger (Set sampling time = 0 seconds)</strong><br />
1) Set sampling time is to 0 second; Press the REC Button, and the “REC” symbol will appear on the LCD screen. Press the Logger Button, and the “REC” symbol will flash once and one Beep will sound, at the same time the measuring data along the time information will be saved in memory. The lower Display will show the Position (record) number, which is saved as well.<br />
2) To Change the Position Number; press the Down Button and the lower position number will flash on the display. Press the Up or Down Buttons to set the Position Number (1 to 99) to help identify the measurement location. The lower Display will show P x (x = 1 to 99). After the position number is selected, press the Enter Button to confirm.<br />
3) Stop Datalogging; press the REC Button for 2 seconds, and the “REC” symbol will disappear indicating the Datalogging function has started.</p>
<h4>REED SD-8205 Specifications</h4>
<ul class="gkCircle2">
<li><strong>Velocity</strong><br />
Range: 0.5 to 199.9 mm/s; 0.05 to 19.99 cm/s; 0.02 to 7.87 in/s<br />
Resolution: 0.1 mm/s; 0.01 cm/s; 0.01 in/s<br />
Accuracy: ±(5% + 2 dgt)</li>
<li><strong>Acceleration</strong><br />
Range: 0.5 to 199.9 m/s2; 0.05 to 20.39 g; 2 to 656ft/s2<br />
Resolution: 0.1m/s2, 0.01 g, 1 ft/s2<br />
Accuracy: ±(5% + 2 dgt)</li>
<li>Circuit: Custom microprocessor LSI circuit</li>
<li>Display: 52mm x 38mm LCD with backlight</li>
<li>Frequency Range: 10Hz &#8211; 1KHz</li>
<li>Auto Sampling Time: 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds</li>
<li>Memory Card: SD memory card, 1 GB to 16 GB</li>
<li>Data Output: USB/RS232 PC computer interface</li>
<li>Temperature Range: 0-50°C (0-122°F)</li>
<li>Power Supply: 6 x 1.5V UM3/AA batteries</li>
<li>Dimensions: Main instrument: 203 x 76 x 38mm; Probe: 37 x 16mm dia, Cable Length: 1.2m</li>
<li>Weight: Main instrument: 515g; Probe: 99g</li>
</ul>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-8205-vibration-meter-data-logger/">REED SD-8205 Vibration Meter &#038; Data Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-sd-8205-vibration-meter-data-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed GD-3300 Combustible Gas Detector</title>
		<link>https://obiat.com.au/product/reed-gd-3300-combustible-gas-detector/</link>
					<comments>https://obiat.com.au/product/reed-gd-3300-combustible-gas-detector/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:53 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-gd-3300-combustible-gas-detector/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<h4>REED GD-3300 Offers</h4>
<p>The REED Combustible Gas Leak Detector is a battery operated device that is designed to transmit warnings via a series of audible and visible signals, such as alarms and flashing lights, when dangerous levels of gas vapors are detected. The GD-3300 can be used to trace leaks from natural gas lines, propane tanks, butane tanks, or any other combustible gas source and warn of a dangerous gas level.</p>
<p><strong>Features</strong></p>
<ul>
<li>Detects a wide variety of gases, including some toxic gases and nuisance vapors</li>
<li>Following is a partial list of the more common gases detected: Natural Gas; Propane; Butane; Methane; Acetone; Alcohol; Ammonia; Steam; Carbon Monoxide; Gasoline; Jet Fuel; Hydrogen Sulfide; Smoke; Industrial Solvents; Lacquer Thinner; Naphtha</li>
<li>Precision semi-conductor sensor detects even the smallest leaks</li>
<li>Audible (variable tick rate) and visible indications help to pinpoint leak sources</li>
<li>Adjustable sensitivity helps to eliminate background gas concentrations in contaminated environments</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="152" height="90" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-gd-3300-combustible-gas-detector/">Reed GD-3300 Combustible Gas Detector</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>The Combustible Gas Leak Detector has a 16” gooseneck probe to find leaks in hard-to-reach areas. It’s adjustable alarm, one-hand operation with thumb-controlled sensitivity adjustment, and impact-resistant storage case add up to value and convenience.</strong></p>
<h4>REED GD-3300 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td>Sensitivity</td>
<td>50 ppm methane</td>
</tr>
<tr>
<td>Response Time</td>
<td>&lt; 2 seconds</td>
</tr>
<tr>
<td>Alarm Limit</td>
<td>At 10% LEL for methane (can be calibrated for other</p>
<p>concentrations or gases up to 40% LEL)</td>
</tr>
<tr>
<td>Power Supply</td>
<td>3 x &#8220;C&#8221; batteries</td>
</tr>
<tr>
<td>Battery Life</td>
<td>8 hours of continuous use</td>
</tr>
<tr>
<td>Probe Length</td>
<td>16&#8243; gooseneck</td>
</tr>
</tbody>
</table>
<h4>What&#8217;s included with the REED GD-3300</h4>
<ul>
<li>GD-3300 Combustible Gas Detector</li>
<li>Batteries</li>
<li>Earphone Jack (for noisy environments)</li>
</ul>
<p><strong> Replacing the Batteries </strong></p>
<p>Replace your 1.5 volt /size R14C(B) alkaline batteries when: • The green READY light off • No light or other activity occurs upon turning the instrument on To replace the batteries: 1. Lay the instrument face-down on a back face. 2.Remove the battery cover. Apply upward pressure to the tab at the bottom of the battery cover while lifting it out. 3.Remove the batteries using a coin or screwdriver, if necessary, to pry them out. 4.Replace all three batteries with new ones.</p>
<p><strong>Replacing the Sensor </strong></p>
<p>Although the sensor is designed to offer many years of reliable service, it may become inoperable if it is submerged in liquid or otherwise physically damaged. To replace sensor: 1. Turn the instrument off 2.Remove the upper tip guard by pressing straight up from the alignment notch that separates the two halves of the tip guard. 3. This is a sturdy component, but use caution bending its leads. 4. Pull the sensor straight up from its tip housing. 5.Replace the sensor, pressing it straight in. 6.Reassemble in reverse order.</p>
<p>The post <a href="https://obiat.com.au/product/reed-gd-3300-combustible-gas-detector/">Reed GD-3300 Combustible Gas Detector</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-gd-3300-combustible-gas-detector/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed R8001 Laser Distance Meter</title>
		<link>https://obiat.com.au/product/reed-r8001-laser-distance-meter/</link>
					<comments>https://obiat.com.au/product/reed-r8001-laser-distance-meter/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:51 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-r8001-laser-distance-meter/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The REED R8001 is a REED Laser distance meter used to measure the distance without bulky reel-in tapes, or walking wheel distance measurement systems. The REED R8001 instrument maximises the use of laser point technology and provides measurements with ±1.5 mm (±0.06") accuracy. The REED Laser Distance Meter is used also for accurately determining the angle, slope and pitch or for area and volume calculations. Comes with battery and it is dust and splash-proof to IP54.</p>
<h4>REED R8001 Features</h4>
<ul class="gkCircle2">
<li>Area and volume calculations</li>
<li>Indirect measurement using Pythagoras</li>
<li>Addition/subtraction continuous measurement</li>
<li>Min/Max and distance tracking</li>
<li>Display illumination and multi-line display</li>
<li>Function beep</li>
<li>Multifunctional end pieces</li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/02/r8001-manual.pdf" target="_blank" rel="">REED R8001 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone  wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="113" height="67" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-r8001-laser-distance-meter/">Reed R8001 Laser Distance Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use Reed R8001 Laser Distance Meter</h4>
<p><strong>Measuring Range</strong><br />
Reed R8001&#8217;s measuring range is limited to 50m. To increase the measurement range during daylight or if the target has poor reflection properties you can use a target plate.</p>
<p><strong>Reference Level Settings</strong><br />
Press the &#8220;Reference&#8221; button to take the selection from the top of the instrument. A special beep sounds whenever the reference setting is changed.</p>
<p><strong>Distance Unit Settings</strong><br />
To change the unit of measurements just hold down the &#8220;Backlight/Unit&#8221; button for a few seconds and toggle between all units of measure. You can choose between m, ft, in, and ft + in.</p>
<p><strong>Single Distance Measurements</strong><br />
Firstly, you have to activate the laser by pressing &#8220;the On/Measure&#8221; button. Now trigger the dsitance measurement by pressing the button again. The measured value will be displayed immediately.</p>
<p><strong>Continuous (Tracking)/Max &amp; Min Measurement</strong><br />
For example, the user can move from a wall to the required distance, while the actual distance can be read continuously. To activate this function press the Max/Min button until the indicator for continuous measurements appears on the display. Press it again or press the On/Measure button to stop the function. The function is terminated after 100 continuous measurements.</p>
<p><strong>Addition/Subtraction</strong><br />
Press the &#8220;Plus button&#8221; to add the current measurement to the previous measurement. Press the &#8220;On/Measure&#8221; button to add the second measured value; the result will automatically display. Press the &#8220;Minus&#8221; button to subtract the current measurement from the previous measurement. Press the &#8220;On/Measure&#8221; button for the result to be shown in the summary line and the previous measurement will be shown in the second line. Press the &#8220;Clear&#8221; button for the last step to be cancelled. Press the &#8220;Max/Mi&#8221;n button to return to single distance measurement mode.</p>
<p><strong>Area Measurement</strong><br />
With this Laser Distance Meter you can automatically calculate the area/surface and the results will be displayed in the summary line on the display. Press the &#8220;Area/Volume&#8221; button once to enter Area Measurement mode. Start making the first measurement ( for length) by pressing the &#8220;On/Measure&#8221; button. Press the On/Measure button again to take the second measurement (width). Now the instrument will calculate the area automatically and display the summary lint on the display.</p>
<p><strong>Volume Measurement</strong><br />
Press the Area/Volume button twice to enter Area Measurement mode. Press the On/Measure button to take the first measurement (length), press the On/Measure button again to take the second measurement (width), press the On/Measure button again to take the third measurement (height). Then the volume is automatically calculated and displayed in the summary line on the display.</p>
<p><strong>Indirect Measurement</strong><br />
This is used to determine a distance using two auxiliary measurements. Press the Indirect Measurement button once, the icon will appear on the display. Aim at the highest point and press the On/Measure button to take the measurement. Holding the instrument as horizontal as possible press and hold the On/Measure button to trigger continuous measurement, the horizontal line is measured and shown in the summary and secondary lines.</p>
<p><strong>Three Point Measurement</strong><br />
Press the Indirect Measurement button twice, the icon will appear on the display. Aim at the highest point (1) and press the On/Measure button to trigger the measurement. Holding the instrument as horizontal as possible press and hold the On/Measure button to trigger continuous measurement and sweep the laser up and down over the ideal target point (2), press the On/Measure button again to confirm the value. Aim at the lower point (3) and press the On/Measure button to trigger the measurement. The results are shown in the summary and secondary lines at the same time.</p>
<h4>REED R8001 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td>Measuring Range</td>
<td>5cm to 50m</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±1.5 mm</td>
</tr>
<tr>
<td>Laser</td>
<td>Class 2, 635nm, &lt;1mW</td>
</tr>
<tr>
<td>Power Supply</td>
<td>2 x 1.5V AAA batteries</td>
</tr>
<tr>
<td>Battery Life</td>
<td>Up to 5,000 measurements</td>
</tr>
<tr>
<td>Dimensions</td>
<td>110 x 45 x 27 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>135 g</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/reed-r8001-laser-distance-meter/">Reed R8001 Laser Distance Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r8001-laser-distance-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed C-383 Combustible Gas Detector</title>
		<link>https://obiat.com.au/product/reed-c-383-combustible-gas-detector/</link>
					<comments>https://obiat.com.au/product/reed-c-383-combustible-gas-detector/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:51 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-c-383-combustible-gas-detector/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The REED C-383 Handheld Gas Detector is used to detect petrol, propane, natural gas and fuel oil leaks in industrial or commercial applications. This compact size C-383 combustible gas leak detector that comes with useful features such as both audible and visual indicators (Sound buzzer and tricolor LED bar indicator) or ambient concentration reset function.</p>
<h4>REED C-383 Features</h4>
<ul class="gkCircle2">
<li>Heated semiconductor gas sensor</li>
<li>High-Low sensitivity selector</li>
<li>Detects leaks as small as 5ppm of petrol</li>
<li>Ambient concentration reset function</li>
<li>Audible and visual leak indications</li>
<li>Flexible stainless steel probe</li>
<li>Low battery indication</li>
<li>Auto Power OFF</li>
</ul>
<p><a href="http://obiat.com.au/wp-content/uploads/2016/02/c-383-manual.pdf"><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" /></a> <a href="http://obiat.com.au/wp-content/uploads/2016/02/c-383-manual.pdf" target="_blank" rel="noopener">Reed C-383 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="98" height="58" /></p>
<h4></h4>
<p>The post <a href="https://obiat.com.au/product/reed-c-383-combustible-gas-detector/">Reed C-383 Combustible Gas Detector</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The REED C-383 Refrigerant Gas Leak Detector is extremely sensitive to a variety of combustible gases such as hydrocarbons and methane. Especially designed to detect even the smallest leaks of gases in domestic and commercial systems the REED C-383 comes with flexible 400mm (15.5”) sensor probe for a maximum flexibility and safety utilization. The Reed handheld gas detector features a sound buzzer to alarm the user when the combustible gas has detected and a visual leak indicator. The meter has two sensitivity level and visual LED indicator to display which level was selected by the user.</p>
<h4 class="title">How to use Handheld Gas Detector (C-383)</h4>
<p><strong>Sensitivity Adjustment</strong><br />
You will be able to set two levels of sensitivity. By default Reed C-383 is set to high sensitivity when the instrument is switched ON. Start changing the sensitivity by pressing the &#8220;Lo Sensitivity&#8221; button. The two left green LED’s will then flash indicating low sensitivity has been selected. To switch the unit back to high sensitivity, press the &#8220;Hi Sensitivity&#8221; button. The two right red LED’s will then flash indicating that high sensitivity has been selected.</p>
<p><strong>Ambient Concentration Reset</strong><br />
This Handheld Gas Detector (C-383) comes with an <strong>ambient concentration reset function</strong>. This feature able you to set the Reed C-383&#8217;s sensors to the ambient gas concentrations presented. Start doing this by turning ON the unit’s sensor that will set the level of present combustible gas to zero. Move your instrument to a location that has clean and fresh air, such as outdoors and press the ON/OFF button.</p>
<p><strong>Measuring</strong><br />
Position the tip of the sensor probe within 1/4 inch (6 mm) of the suspected leak source. Slowly move the sensor probe past each possible leakage point. When the Gas Detector detects a leak source an audible tone will sound and visual indicators will light on the LED leak indicator display, appearing from left to right: green to orange to red (red being the highest concentration, green the lowest). Increasing levels indicates the proximity of the leak location is getting closer. When the unit signals a leakage, pull the probe away from the leak for a moment and then bring it back slowly to pinpoint the location. If the combustible leak is large setting the sensitivity switch to LOW (see sensitivity adjustment) will make it easier to find the exact site of the leak. Return the sensitivity switch to HIGH before searching for any additional leaks. When you’ve finished testing for leaks turn the unit OFF and store it in a cool, dry, clean place to protect the sensor and unit from any possible damage.</p>
<h4>REED C-383 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td>Sensitivity</td>
<td>Variable, as low as 5 ppm (petrol)</td>
</tr>
<tr>
<td>Alarm Settings</td>
<td>7 LED tricolour bar indicator; variable intensity audible alarm</td>
</tr>
<tr>
<td>Warm-up Time</td>
<td>90 seconds</td>
</tr>
<tr>
<td>Power Supply</td>
<td>4 x 1.5V AA alkaline batteries</td>
</tr>
<tr>
<td>Battery Life</td>
<td>Approx. 40 hours continuous use</td>
</tr>
<tr>
<td>Probe Length</td>
<td>400mm</td>
</tr>
<tr>
<td>Dimensions</td>
<td>21.7 x 6.6 x 5.6cm</td>
</tr>
<tr>
<td>Weight</td>
<td>400 g</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/reed-c-383-combustible-gas-detector/">Reed C-383 Combustible Gas Detector</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-c-383-combustible-gas-detector/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed R5004 Phase Sequence/Motor Rotation Tester4</title>
		<link>https://obiat.com.au/product/reed-r5004-phase-sequencemotor-rotation-tester4/</link>
					<comments>https://obiat.com.au/product/reed-r5004-phase-sequencemotor-rotation-tester4/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:46 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-r5004-phase-sequencemotor-rotation-tester4/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The Reed R5004 Phase Sequence/Motor Rotation Tester is highly accurate and has an extremely fast response, great features that recommend it as a versatile tester when you need to check a motor's rotation direction without any contact.</p>
<h4>REED R5004 Features</h4>
<ul class="gkCircle2">
<li>Tests phase orientation of 3-phase power sources</li>
<li>Indicates phase orientation (clockwise or counter-clockwise and whether each of the<br />
three phases is live)</li>
<li>Also indicates direction of motor rotation</li>
<li>Determines motor rotation without contact</li>
<li>Easy to open alligator clips with wide jaws</li>
<li>Double molded housing</li>
<li>Cat. III 600V safety rating</li>
<li>Complete with cables with 3 colour-coded alligator clips, 9V battery and carrying case</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="118" height="70" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-r5004-phase-sequencemotor-rotation-tester4/">Reed R5004 Phase Sequence/Motor Rotation Tester4</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use Reed R5004 Motor Rotation Tester</h4>
<p><strong>Determining the Rotary Field Direction</strong><br />
Make sure the L1,L2, and L3 test leads are connected to the corresponding input jacks. Connect the test probes to the other end of the test leads. Connect the test probes to the three main phases. Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. Either the Clockwise or Counter Clockwise Rotary indicator will illuminate showing the type of rotary field direction present. The rotary indicator will light up even if the neutral conductor, N, is connected instead of the test lead input jack. See Phase Indication Table for more information (User manual).</p>
<p><strong>Determining the Motor Connection</strong><br />
Connect one end of the test leads to the unit and the alligator clamps to the other end of the test leads. Connect the alligator clamps to the motor connections.Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. Turn the motor shaft half a revolution towards the right. The bottom of this unit should be oriented towards the drive shaft. Either the Clockwise or Counter Clockwise Rotary indicator will illuminate showing the type of rotary field direction present.</p>
<p><strong>Non-contact Rotary Field Indication</strong><br />
Put the Motor Rotation Tester on the motor so that it is parallel to the length of the motor shaft. The unit should be one inch or closer to the motor, and the bottom of the unit should be oriented towards the drive shaft. Press the ON/OFF button. The green ON indicator shows that the instrument is ready for testing. Either the Clockwise or Counter Clockwise Rotary indicator will illuminate showing the type of rotary field direction present.</p>
<p><strong>Magnetic Field Detection</strong><br />
To detect a magnetic field, place this unit to a solenoid valve. A magnetic field is present if either the Clockwise or the Counter Clockwise Rotary indicator illuminates.</p>
<h4>REED R5004 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td>Input Voltage</td>
<td>40 to 600 VAC</td>
</tr>
<tr>
<td>Operating Frequency</td>
<td>2 to 400 Hz</td>
</tr>
<tr>
<td>Power Supply</td>
<td>9V Alkaline battery</td>
</tr>
<tr>
<td>Dimensions</td>
<td>28 x 68 x 30mm</td>
</tr>
<tr>
<td>Weight</td>
<td>185g</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/reed-r5004-phase-sequencemotor-rotation-tester4/">Reed R5004 Phase Sequence/Motor Rotation Tester4</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r5004-phase-sequencemotor-rotation-tester4/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
