<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LCR Meter Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/reed/lcr-meter/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/reed/lcr-meter/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Fri, 20 May 2016 04:15:22 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>LCR Meter Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/reed/lcr-meter/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Reed R5001 LCR Meter</title>
		<link>https://obiat.com.au/product/reed-r5001-lcr-meter/</link>
					<comments>https://obiat.com.au/product/reed-r5001-lcr-meter/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:48 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-r5001-lcr-meter/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The Reed R5001 LCR meter with Data Hold and Autoranging operation for AC impedance and DE resistance measurement feature allowing you to conduct Inductance (F=1kHz) and Resistance (F=1kHz) tests.</p>
<h4>Reed R5001 Features:</h4>
<ul class="gkCircle2">
<li>Measure inductance/capacitance/resistance with secondary parameters including dissipation<br />
factor (D), quality factor (Q), phase angle (Ø), equivalent series/parallel resistance (ESR or Rp)</li>
<li>Autoranging operation for AC impedance and DE resistance measurement</li>
<li>Auto LCR smart check and measurement</li>
<li>Series/Parallel modes</li>
<li>Ls/Lp/Cp with D/Q/Ø/ESR parameters</li>
<li>Support DCR mode 200 to 200MΩ</li>
<li>High accuracy with 4 or 5 terminal Kelvin measurement</li>
<li>Testing frequency is up to 10kHz and output frequency is up to 100kHz</li>
<li>Dual display with backlight</li>
<li>Data hold function</li>
<li>Low battery indication with auto power off</li>
<li>Dust and waterproof to IP67</li>
<li>Includes test leads and batteries.</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone  wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="106" height="63" /></p>
<p>&#160;</p>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/reed-r5001-lcr-meter/">Reed R5001 LCR Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use Reed R5001 Data hold LCR meter</h4>
<p>&nbsp;</p>
<p><strong>Test Frequency Functions</strong><br />
When <strong>measuring capacitance</strong>, commonly a 1kHz test frequency is used to measure capacitors that are 0.01μF or smaller. For capacitors that are 10μF or larger, a lower frequency of 120Hz is used. Based on this settings, a high-test frequencies are best for testing very low capacitance components. For large capacitance components, low frequency would be optimal.</p>
<p>When you use this instrument for <strong>measuring inductance</strong>inductors below 2 mH should be measured at 1kHz frequency while inductors above 200H should be measured at 120Hz.</p>
<p><strong>Test Frequency Select</strong><br />
The test frequency can affect the accuracy of the results depending on what frequency is selected and what type and value of a component is being measured or tested. The meter has five test frequencies: 100Hz/120Hz/1kHz/10kHz/100kHz. To set the <strong>&#8220;Test Frequency&#8221;</strong>press the Frequency Button to scroll through the five frequencies sequentially.</p>
<p><strong>Primary Impedance with Secondary Parameter Test</strong><br />
&#8220;Auto-LCR Mode&#8221;, will check the type of impedance and automatically. To switch from &#8220;Auto-LCR&#8221; Mode to &#8220;Auto-&#8220;L Mode, &#8220;Auto-C&#8221; Mode, &#8220;Auto-R&#8221; Mode, and &#8220;DCR&#8221; Mode, Press the Function Button. When Auto-L or Auto-C Mode are selected, the impedance measurement is auto ranging.The Reed R5001&#8217;s primary LCD display will show the inductance or capacitance of DUT (device under test); the secondary LCD display will show the quality or dissipation factor. Press the Secondary Display/Left Button to display the D/Q/ θ/ESR value. When Auto-R (ACR mode) or DCR mode is selected the secondary parameter is omitted.</p>
<p><strong>Series or Parallel Functions</strong><br />
Most <strong>capacitance measurements</strong> will obtain best results with parallel mode selected. Most <strong>inductance measurements</strong> will obtain best results with series mode selected.</p>
<p><strong>Series/Parallel Measurements</strong><br />
When any L/C/R function is selected, the default measurement will be automatically selected. If the impedance is greater than 10kΩ, the meter will select the parallel mode and “Lp/Cp/Rp” icon will be displayed on the LCD screen. The meter will automatically select the &#8220;series mode&#8221; in case of 10kΩ less impedance. “Ls/ Cs/Rs” icon will display on the LCD. You can set the impedance measurement in series mode or in parallel mode sequentially by pressing the Parallel/Series/Right Button.</p>
<p><strong>Data Hold</strong><br />
Press the Hold Button to activate data hold function and &#8220;freeze&#8221; the current measurement on the display. Press the Hold Button again to deactivate it.</p>
<p><strong>Relative mode</strong><br />
This function able you to reserve the current DUT readings (DCUR) on the primary display as a reference value (DREF). To activate this, press the Relative/Down Button.The secondary display will show the percentage of the relative value (REL%). Press the Relative/ Down Button again to show the reference value (DREF) on the primary display;The percentage range is -99.9% to 99.9%. When the relative value is larger than double the reference value (DREF), the symbol “OL%” will appear on the secondary display.</p>
<h4>REED R5001 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td colspan="2"><strong>Inductance (F=1kHz)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>2000.0µH<br />
20.000/200.0/2000.0mH<br />
20.000/200.00/2000.0H</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1/1µH<br />
0.01/0.1/1mH<br />
0.01/1H</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.5% +15 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>Capacitance (F=1kHz)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>2000.0pF<br />
20.000/200.00/2000.0nF<br />
20.00/200.00/2000µF</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.01/0.1/1pF<br />
0.01/0.1/1nF<br />
0.1µF</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.0% +10 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>Resistance (F=1kHz)</strong></td>
</tr>
<tr>
<td>Range</td>
<td>20.000/200.00Ω<br />
2.0000/20.000/200.00kΩ<br />
2.0000/20.000/200.0MΩ</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.01/0.1/1Ω<br />
0.01/0.1/1kΩ<br />
0.1MΩ</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(1.5% +5 dgt.)</td>
</tr>
<tr>
<td colspan="2"><strong>General Specifications</strong></td>
</tr>
<tr>
<td>Test Frequencies</td>
<td>100/120/1k Hz<br />
10k Hz<br />
100k Hz</td>
</tr>
<tr>
<td>Test Signal Level</td>
<td>0.5V AC RMS typical</td>
</tr>
<tr>
<td>Power Supply</td>
<td>6 x 1.5V AA batteries</td>
</tr>
<tr>
<td>Dimensions</td>
<td>220 x 96 x 60mm</td>
</tr>
<tr>
<td>Weight</td>
<td>360g</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/reed-r5001-lcr-meter/">Reed R5001 LCR Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r5001-lcr-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
