<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Temperature/Humidity Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-category/tenmars/temperaturehumidity/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-category/tenmars/temperaturehumidity/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Thu, 05 Feb 2026 21:52:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Temperature/Humidity Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-category/tenmars/temperaturehumidity/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Tenmars TM-183P Temperature and Humidity Meter</title>
		<link>https://obiat.com.au/product/tenmars-tm-183p-temperature-and-humidity-meter/</link>
					<comments>https://obiat.com.au/product/tenmars-tm-183p-temperature-and-humidity-meter/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-183p-temperature-and-humidity-meter/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-844" src="http://obiat.com.au/wp-content/uploads/2016/02/Tenmars_logo_05.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p>Product Description</p>
<ul>
<li>Dual display of temperature and humidity.</li>
<li>Select <span style="font-family: Verdana;">°C or °F.</span></li>
<li><span style="font-family: Verdana;"> Simultaneously hold both Temperature and Humidity readings.</span></li>
<li><span style="font-family: Verdana;"> Simultaneously hold both Minimum/Maximum/Average (Min/Max/Avg) readings with time marks.</span></li>
<li><span style="font-family: Verdana;">REL (Relative) function.</span></li>
<li><span style="font-family: Verdana;"> Alarm alert (SET) function.</span></li>
<li><span style="font-family: Verdana;"> DEW-POINT and WET-BULB temperature measurement.</span></li>
<li><span style="font-family: Verdana;"> Stores up to 200 readings.</span></li>
<li><span style="font-family: Verdana;">Low battery indication.</span></li>
<li><span style="font-family: Verdana;"> Auto Power Off.</span></li>
</ul>
<p><span style="font-family: Verdana; font-size: medium;"> Application</span></p>
<ul>
<li><span style="font-family: Verdana;">The temperature/humidity meter has a highly accurate sensor chip to measure relative humidity and temperature. It is perfect for many industrial applications, laboratory and other work locations</span></li>
</ul>
<p><strong>Authorised Australian Distributor.</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-183p-temperature-and-humidity-meter/">Tenmars TM-183P Temperature and Humidity Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5"><span style="color: #ffffff; font-size: medium;">Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Display</td>
<td bgcolor="#e7f7ff" width="70%">Dual LCD display. Max value primary display is 1999, secondary display is 9999</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Sampling Rate</td>
<td bgcolor="#e7f7ff" width="70%">One sample/second</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Temperature Measurement Range</td>
<td bgcolor="#e7f7ff" width="70%">-20<span style="font-family: Verdana;">°C to 60°C</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±0.8°C (±1.5°F)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Humidity Measurement Range</td>
<td bgcolor="#e7f7ff" width="70%">1% to 99% R.H.</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Humidity Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±3% (20% to 80% RH at 25°C), ±5% (80% at 25°C)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Operating Temperature</td>
<td bgcolor="#e7f7ff" width="70%">0<span style="font-family: Verdana;">°C to 60°C</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Storage Temperature</td>
<td bgcolor="#e7f7ff" width="70%">-10<span style="font-family: Verdana;">°C to 60°C</span></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5" width="798"><span style="color: #ffffff; font-size: medium;"> General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Power Supply</td>
<td bgcolor="#e7f7ff" width="556">9 Volt battery. NEDA 1604, IEC 6F22, JIS 006P</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Battery Life</td>
<td bgcolor="#e7f7ff" width="556">approx 200 hours</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Dimensions</td>
<td bgcolor="#e7f7ff" width="556">200mm (L) x 55mm (W) x 38mm (D)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Weight</td>
<td bgcolor="#e7f7ff" width="556">approx. 200g (excluding battery)</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">Ordering Information</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="left" bgcolor="#085aa5" width="234"><span style="color: #ffffff; font-size: medium;"> Model Name</span></td>
<td align="left" bgcolor="#085aa5" width="556"><span style="color: #ffffff; font-size: medium;"> Description</span></td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="234">Tenmars TM-183P</td>
<td align="left" bgcolor="#e7f7ff" width="556">Temperature and Humidity Meter<br />
<b>Included accessories: </b> User&#8217;s manual, 9-volt battery, Carrying case, and Temperature/Humidity probe</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<h3>Check before Using</h3>
<div> Make sure the battery is installed properly. If the LCD</div>
<div>displays</div>
<div> When turning on the thermometer, all LCD displayed</div>
<div>items will be lighted about 1 second.</div>
<div> Make sure all the function switches are positioned</div>
<div>correctly. ( Make sure the &#8220;HOLD&#8221; sign is not displayed</div>
<div>on the LCD. )</div>
<div>
<div>Measurement Method</div>
<div> Power on the Temperature / Humidity Meter. If you want</div>
<div>to disable the auto-power off function,</div>
<div> Put the Temperature / Humidity Meter into the place wait</div>
<div>for measuring.</div>
<div>Keep the thermometer still about 15 minutes to</div>
<div>achieve the best readings. ( According to measuring</div>
<div>space and the measuring temperature and humidity</div>
<div>maybe increase or decrease of readings.)</div>
<div></div>
</div>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-183p-temperature-and-humidity-meter/">Tenmars TM-183P Temperature and Humidity Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/tenmars-tm-183p-temperature-and-humidity-meter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-184 Precision Temperature and Humidity Meter Datalogger</title>
		<link>https://obiat.com.au/product/tenmars-tm-184-precision-temperature-and-humidity-meter-datalogger/</link>
					<comments>https://obiat.com.au/product/tenmars-tm-184-precision-temperature-and-humidity-meter-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-184-precision-temperature-and-humidity-meter-datalogger/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-844" src="http://obiat.com.au/wp-content/uploads/2016/02/Tenmars_logo_05.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p>Product Description</p>
<ul>
<li>High Accurate Humidity Measurement <span style="font-family: Verdana;">±1% R.H.</span></li>
<li><span style="font-family: Verdana;"> Relative Humidity range from 1% to 99%.</span></li>
<li>Dual LCD backlit display with Temperature and Humidity readings.</li>
<li>Maximum primary display: 1999.</li>
<li>Maximum secondary display: 9999.</li>
<li>Min/Max, and Data Hold function.</li>
<li>Auto power Off with disable function.</li>
<li>Low battery indication.</li>
<li>Alarm for Hi Low limit: Temperature and Humidity.</li>
<li>Dew-Point and Wet bulb.</li>
<li>USB Datalogger: 30000 records.</li>
<li>Length of wire for sensor: approx. 1 meter.</li>
<li>Real-time clock and calendar.</li>
</ul>
<p><span style="font-size: medium;"> Application</span></p>
<ul>
<li>Maintenance, Utility,</li>
<li>Technicians,</li>
<li>HVAC service.</li>
</ul>
<p><strong>Authorised Australian distributor</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-184-precision-temperature-and-humidity-meter-datalogger/">Tenmars TM-184 Precision Temperature and Humidity Meter Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Tenmars TM-184 Precision Temperature and Humidity Meter Datalogger has high Accurancy Measuremetn up to 1%RH. Light weight, pocket-sized design. Take accurate measurement for humidity, temperature, wet bulb and dew point.</p>
<p>&nbsp;</p>
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5"><span style="color: #ffffff; font-size: medium;">Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">LCD Display Character Height</td>
<td bgcolor="#e7f7ff" width="70%">42mm x 32mm (1.656&#8243; x 1.26&#8243;)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Ranges</td>
<td bgcolor="#e7f7ff" width="70%">-20<span style="font-family: Verdana;">°C to 60°C (-40°F to 140°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±0.5°C (0°C to 40°C), ±1.5°F (32°F to 104°F), other ±2.0°C/3.6°F</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Resolution</td>
<td bgcolor="#e7f7ff" width="70%">0.1<span style="font-family: Verdana;">°C and 0.1°F</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Updating Rate</td>
<td bgcolor="#e7f7ff" width="70%">One time/second</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Sensor Type</td>
<td bgcolor="#e7f7ff" width="70%">Diode</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Humidity Sensor Type</td>
<td bgcolor="#e7f7ff" width="70%">Capacitor</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Range</td>
<td bgcolor="#e7f7ff" width="70%">1.0% to 99.0%</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±1% RH (at 25°C, 15% to 90% RH) ±2.5% RH (at &lt;15% RH, &gt;90% RH)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Resolution</td>
<td bgcolor="#e7f7ff" width="70%">0.1%</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Dew Point Range</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> -30°C to 100°C (-22°F to 212°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Wet Bulb Range</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> 0°C to 80°C (32°F to 176°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Response Time</td>
<td bgcolor="#e7f7ff" width="70%">Below 10 seconds</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5" width="798"><span style="color: #ffffff; font-size: medium;"> General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Power Supply</td>
<td bgcolor="#e7f7ff" width="556">9 Volt battery. NEDA 1604, IEC 6F22, JIS 006P or AC/DC (9V/300mA) adapter.</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Dimensions</td>
<td bgcolor="#e7f7ff" width="556">130mm (L) x 56mm (W) x 38mm (D)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Weight</td>
<td bgcolor="#e7f7ff" width="556">approx. 250g</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">Ordering Information</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="left" bgcolor="#085aa5" width="234"><span style="color: #ffffff; font-size: medium;"> Model Name</span></td>
<td align="left" bgcolor="#085aa5" width="556"><span style="color: #ffffff; font-size: medium;"> Description</span></td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="234">Tenmars TM-184</td>
<td align="left" bgcolor="#e7f7ff" width="556">Precision Temperature and Humidity Meter<br />
<b>Included accessories: </b> User&#8217;s manual, 9-volt battery, Carrying case, Mini USB 4P (M) to USB &#8216;A&#8217; type cable and CD install disk.</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>Battery Replacement</p>
<p>WARNING If the LCD display “ ” symbol, please replace the battery immediately  Turn off the instrument.  Open the battery cover and remove the battery.  Replace with four-9V NEDA 1604, IEC 6F22 or JIS 006P size battery.  Install the battery cover. WARNING If you will not use this meter for a long time, please remove the battery in order to protect the meter.</p>
<p>External DC Power  External AC to DC adapter: Voltage 9VDC(8~14VDCMax)  Socket：pin Positive, Ground Casing External  Diameter 5.5mm internal Diameter 2.1 mm 24.</p>
<p>Safety Precaution  For cleaning the instrument, use a soft dry cloth. Never use a wet cloth, solvents or water, etc.  Data logging capacity with Memory Size：30000 data sets Operation Altitude: Up to 2000M. </p>
<p>Operating Environment: Indoors use only. This instrument has been designed for being used in an environment of pollution degree 2.</p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-184-precision-temperature-and-humidity-meter-datalogger/">Tenmars TM-184 Precision Temperature and Humidity Meter Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/tenmars-tm-184-precision-temperature-and-humidity-meter-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-185 LED Temperature, Humidity Monitor</title>
		<link>https://obiat.com.au/product/tenmars-tm-185-led-temperature-humidity-monitor/</link>
					<comments>https://obiat.com.au/product/tenmars-tm-185-led-temperature-humidity-monitor/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-185-led-temperature-humidity-monitor/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-844" src="http://obiat.com.au/wp-content/uploads/2016/02/Tenmars_logo_05.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p>TM-185.... Large LED Screen (23mm x 120mm)<br />
Temperature/Humidity Monitor</p>
<p><span style="font-size: medium;">Product Description</span></p>
<ul>
<li>Complete environmental monitor and alarm.</li>
<li>Wall mounted easy reading large LED display for simultaneous reading of Humidity and Temperature.</li>
<li>Dual LED display: maximum reading Primary Display is 1999, maximum reading of bottom Secondary Display is 999.</li>
<li>Time clock.</li>
<li>Alarm set for Hi and Low limit. Temperature and Humidity.</li>
<li>LED Display, displays real-time data.</li>
</ul>
<p><span style="font-size: medium;"> Applications</span></p>
<ul>
<li>Warehouses, Laboratories, Electronics Manufacturing, Refrigerators/Freezers, Hospitals Blood Supplies, Tissue Banks, Computer Rooms, Clean Rooms, Defence Environments, and other critical areas.</li>
</ul>
<p><strong>Authorised Australian distributor</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-185-led-temperature-humidity-monitor/">Tenmars TM-185 LED Temperature, Humidity Monitor</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5"><span style="color: #ffffff; font-size: medium;">Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">LCD Character Dimensions</td>
<td bgcolor="#e7f7ff" width="70%">214mm x 120mm (8.4&#8243; x 4.73&#8243;)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Ranges</td>
<td bgcolor="#e7f7ff" width="70%">-20<span style="font-family: Verdana;">°C to 60°C (-4°F to 140°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±1.0°C (-5°C to 40°C), ±1.8°F (23°F to 104°F), other ±2.0°C/3.6°F</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Resolution</td>
<td bgcolor="#e7f7ff" width="70%">0.1<span style="font-family: Verdana;">°C and 0.1°F</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Updating Rate</td>
<td bgcolor="#e7f7ff" width="70%">One time per second</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Sensor Type</td>
<td bgcolor="#e7f7ff" width="70%">Diode</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Range</td>
<td bgcolor="#e7f7ff" width="70%">5% to 95%</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±2.0% RH (at 25°C, 35% to 80% RH) ±2.5% RH (at at 25°C, 10% to 35%, 80% to 90% RH) other ±5% RH (at 25°C, &lt;10% RH, &gt;90% RH)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Resolution</td>
<td bgcolor="#e7f7ff" width="70%">1.0%</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Response Time</td>
<td bgcolor="#e7f7ff" width="70%">less than 4 seconds</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Dew Point Range</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> -30°C to 100°C (-22°F to 212°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Wet Bulb Range</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> 0°C to 80°C (32°F to 176°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Response Time</td>
<td bgcolor="#e7f7ff" width="70%">Below 4 seconds</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5" width="798"><span style="color: #ffffff; font-size: medium;"> General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Power Supply</td>
<td bgcolor="#e7f7ff" width="556">AC/DC 50/60Hz adapter (9V/1A)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Battery Backup</td>
<td bgcolor="#e7f7ff" width="556">9 Volt battery enables continued measurement during power disruption</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Dimensions</td>
<td bgcolor="#e7f7ff" width="556">260mm (L) x 178mm (W) x 47mm (D)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Weight</td>
<td bgcolor="#e7f7ff" width="556">1000g</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">Ordering Information</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="left" bgcolor="#085aa5" width="234"><span style="color: #ffffff; font-size: medium;"> Model Name</span></td>
<td align="left" bgcolor="#085aa5" width="556"><span style="color: #ffffff; font-size: medium;"> Description</span></td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="234">Tenmars TM-185</td>
<td align="left" bgcolor="#e7f7ff" width="556">Temperature and Humidity Monitor<br />
<b>Included accessories: </b> User&#8217;s manual, 9-volt battery,</td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="234">Tenmars TM-185D</td>
<td align="left" bgcolor="#e7f7ff" width="556">Temperature and Humidity Monitor Datalogger<br />
<b>Included accessories: </b> User&#8217;s manual, 9-volt battery, and AC/DC adapter</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-185-led-temperature-humidity-monitor/">Tenmars TM-185 LED Temperature, Humidity Monitor</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/tenmars-tm-185-led-temperature-humidity-monitor/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-185D LED Temperature, Humidity Meter Datalogger</title>
		<link>https://obiat.com.au/product/tenmars-tm-185d-led-temperature-humidity-meter-datalogger/</link>
					<comments>https://obiat.com.au/product/tenmars-tm-185d-led-temperature-humidity-meter-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-185d-led-temperature-humidity-meter-datalogger/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-844" src="http://obiat.com.au/wp-content/uploads/2016/02/Tenmars_logo_05.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p>TM-185D.... Large LED Screen (23mm x 120mm)<br />
Temperature/Humidity Monitor &#38; Datalogger</p>
<p><span style="font-size: medium;">Product Description</span></p>
<ul>
<li>Complete environmental monitor and alarm.</li>
<li>Wall mounted easy reading large LED display for simultaneous reading of Humidity and Temperature.</li>
<li>Dual LED display: maximum reading Primary Display is 1999, maximum reading of bottom Secondary Display is 999.</li>
<li>Time clock.</li>
<li>Alarm set for Hi and Low limit. Temperature and Humidity.</li>
<li>Datalogging Capacity 30000 records</li>
<li>LED Display, displays real-time data.</li>
</ul>
<p><span style="font-size: medium;"> Applications</span></p>
<ul>
<li>Warehouses, Laboratories, Electronics Manufacturing, Refrigerators/Freezers, Hospitals Blood Supplies, Tissue Banks, Computer Rooms, Clean Rooms, Defence Environments, and other critical areas.</li>
</ul>
<p><strong>Authorised Australian distributor</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-185d-led-temperature-humidity-meter-datalogger/">Tenmars TM-185D LED Temperature, Humidity Meter Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5"><span style="color: #ffffff; font-size: medium;">Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">LCD Character Dimensions</td>
<td bgcolor="#e7f7ff" width="70%">214mm x 120mm (8.4&#8243; x 4.73&#8243;)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Ranges</td>
<td bgcolor="#e7f7ff" width="70%">-20<span style="font-family: Verdana;">°C to 60°C (-4°F to 140°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±1.0°C (-5°C to 40°C), ±1.8°F (23°F to 104°F), other ±2.0°C/3.6°F</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Resolution</td>
<td bgcolor="#e7f7ff" width="70%">0.1<span style="font-family: Verdana;">°C and 0.1°F</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Updating Rate</td>
<td bgcolor="#e7f7ff" width="70%">One time per second</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Temperature Sensor Type</td>
<td bgcolor="#e7f7ff" width="70%">Diode</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Range</td>
<td bgcolor="#e7f7ff" width="70%">5% to 95%</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±2.0% RH (at 25°C, 35% to 80% RH) ±2.5% RH (at at 25°C, 10% to 35%, 80% to 90% RH) other ±5% RH (at 25°C, &lt;10% RH, &gt;90% RH)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Resolution</td>
<td bgcolor="#e7f7ff" width="70%">1.0%</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Response Time</td>
<td bgcolor="#e7f7ff" width="70%">less than 4 seconds</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Dew Point Range</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> -30°C to 100°C (-22°F to 212°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Wet Bulb Range</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> 0°C to 80°C (32°F to 176°F)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Relative Humidity Response Time</td>
<td bgcolor="#e7f7ff" width="70%">Below 4 seconds</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5" width="798"><span style="color: #ffffff; font-size: medium;"> General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Power Supply</td>
<td bgcolor="#e7f7ff" width="556">AC/DC 50/60Hz adapter (9V/1A)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Battery Backup</td>
<td bgcolor="#e7f7ff" width="556">9 Volt battery enables continued measurement during power disruption</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Dimensions</td>
<td bgcolor="#e7f7ff" width="556">260mm (L) x 178mm (W) x 47mm (D)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Weight</td>
<td bgcolor="#e7f7ff" width="556">1000g</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">Ordering Information</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="left" bgcolor="#085aa5" width="234"><span style="color: #ffffff; font-size: medium;"> Model Name</span></td>
<td align="left" bgcolor="#085aa5" width="556"><span style="color: #ffffff; font-size: medium;"> Description</span></td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="234">Tenmars TM-185</td>
<td align="left" bgcolor="#e7f7ff" width="556">Temperature and Humidity Monitor<br />
<b>Included accessories: </b> User&#8217;s manual, 9-volt battery,</td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="234">Tenmars TM-185D</td>
<td align="left" bgcolor="#e7f7ff" width="556">Temperature and Humidity Monitor Datalogger<br />
<b>Included accessories: </b> User&#8217;s manual, 9-volt battery, and AC/DC adapter</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>Maintenance</p>
<p> Do not use the meter in an environment with severe change; do not store the unit in an environment with high temperature, high humidity, and high vibration  Take battery off if the meter has not been used for a long period of time  The Diode temperature probe is used to measure temperature and the capacitive humidity sensor is used to measure take humidity  The thermocouple and humidity sensor will start aging under the influence of oxidation, reduction, corrosion, pollution, vaporization, diffusion or other metallurgy. The aging process will affect its precision seriously.  Cleaning and inspection of temperature probe: The smoke, coal, dust, grease attached on the protective tube of temperature probe will slow down the heat conduction of the thermocouple and cause measuring error. Therefore, it should be cleaned periodically. The metal coating of thin thermocouple should be replaced properly upon the occurrence of corrosion.  Cleaning and inspection of humidity sensor: The smoke and dust attached on the humidity sensor will slow down the function of humidity sensor and cause measuring error. Therefore, it should be cleaned periodically. Blow off the dust with mild compressed air instead of water or alcohol. The aluminum plate inside the humidity sensor should be replaced upon the occurrence of corrosion.</p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-185d-led-temperature-humidity-meter-datalogger/">Tenmars TM-185D LED Temperature, Humidity Meter Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/tenmars-tm-185d-led-temperature-humidity-meter-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-182 Temperature, Humidity Meter with Datalogging function</title>
		<link>https://obiat.com.au/product/tenmars-tm-182-temperature-humidity-with-datalogging-function/</link>
					<comments>https://obiat.com.au/product/tenmars-tm-182-temperature-humidity-with-datalogging-function/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-182-temperature-humidity-with-datalogging-function/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-844" src="http://obiat.com.au/wp-content/uploads/2016/02/Tenmars_logo_05.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p>Tenmars TM-182 Temperature, Humidity Meter with Datalogging Features:</p>
<ul>
<li>Dual Liquid Crystal Display with Backlight; Humidity up to 999, and Temperature up to 1999.</li>
<li><span style="font-family: Verdana;">°C or °F switchable.</span></li>
<li><span style="font-family: Verdana;"> Real time data.</span></li>
<li><span style="font-family: Verdana;"> Data Hold function.</span></li>
<li><span style="font-family: Verdana;"> Alarm function.</span></li>
<li><span style="font-family: Verdana;"> Auto Power Off.</span></li>
<li><span style="font-family: Verdana;"> Dew-point and Wet-bulb temperature.</span></li>
<li><span style="font-family: Verdana;"> Overload display.</span></li>
<li><span style="font-family: Verdana;">Low battery indication.</span></li>
<li><span style="font-family: Verdana;">USB PC interface.</span></li>
</ul>
<p><span style="font-family: Verdana; font-size: medium;"> Application</span></p>
<ul>
<li><span style="font-family: Verdana;"> HVAC Inspection.</span></li>
</ul>
<p><strong>Authorised Australian Distributor.</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-182-temperature-humidity-with-datalogging-function/">Tenmars TM-182 Temperature, Humidity Meter with Datalogging function</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Tenmars TM-182 Temperature, Humidity Meter with Datalogging</h3>
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5"><span style="color: #ffffff; font-size: medium;">Specifications</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Measurement Range</td>
<td bgcolor="#e7f7ff" width="70%">Humidity: 1% to 99%<br />
Temperature: -20°C to 60°C (-4.0°F to 140.0°F)</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Temperature Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±0.8°C/±1.5°F (0.0°C to 40.0°C/32°F to 104°F); other ±2.0°C/3.6°F</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Humidity Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±3.0% RH (20% RH to 80% RH),<br />
±5.0% RH (80% RH)</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Resolution</td>
<td bgcolor="#e7f7ff" width="70%">0.1 RH, 0.1<span style="font-family: Verdana;">°C and 0.1°F</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±(0.05% + 0.7°C)<br />
±(0.05% + 1.4°F)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Temperature Sensor</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> Diode</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Humidity Sensor</td>
<td bgcolor="#e7f7ff" width="70%">Capacitor</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Sampling Time</td>
<td bgcolor="#e7f7ff" width="70%">1/second</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Data Logging Memory Size</td>
<td bgcolor="#e7f7ff" width="70%">30,000 data sets</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Operating Temperature</td>
<td bgcolor="#e7f7ff" width="70%">-20°C to 60°C</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Storage Temperature/Humidity</td>
<td bgcolor="#e7f7ff" width="70%">-10°C to 60°C</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5" width="798"><span style="color: #ffffff; font-size: medium;"> General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Power Supply</td>
<td bgcolor="#e7f7ff" width="556">9 Volt battery. NEDA 1604, IEC 6F22, JIS 006P or AC/DC adapter (9V/300mA)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Current Consumption</td>
<td bgcolor="#e7f7ff" width="556">approx 10mA</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Dimensions</td>
<td bgcolor="#e7f7ff" width="556">130mm (L) x 56mm (W) x 38mm (D)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Weight</td>
<td bgcolor="#e7f7ff" width="556">approx. 250g</td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"><span style="font-size: medium;">Ordering Information</span></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td align="left" bgcolor="#085aa5" width="234"><span style="color: #ffffff; font-size: medium;"> Model Name</span></td>
<td align="left" bgcolor="#085aa5" width="556"><span style="color: #ffffff; font-size: medium;"> Description</span></td>
</tr>
<tr>
<td align="left" valign="top" bgcolor="#e7f7ff" width="234">Tenmars TM-182</td>
<td align="left" bgcolor="#e7f7ff" width="556">Temperature and Humidity Meter with Datalogging Function<br />
<b>Included accessories: </b> User&#8217;s manual, 9-volt battery, Carrying case, Mini USB 4P (M) to USB A-type Cable and install CD disk.</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-182-temperature-humidity-with-datalogging-function/">Tenmars TM-182 Temperature, Humidity Meter with Datalogging function</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/tenmars-tm-182-temperature-humidity-with-datalogging-function/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-186D CO2 Meter with Temperature and Data Logging</title>
		<link>https://obiat.com.au/product/tenmars-tm-186d-co2-meter-with-temperature-and-data-logging/</link>
					<comments>https://obiat.com.au/product/tenmars-tm-186d-co2-meter-with-temperature-and-data-logging/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:05 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-186d-co2-meter-with-temperature-and-data-logging/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-928" src="http://obiat.com.au/wp-content/uploads/2016/02/Tenmars_logo_05-1.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p>The Tenmars TM-186D monitor can be mounted on a wall or sat upon a desk, and has a unique, large LED display that makes it easy to see the readings, it's ideal for CO2 and temperature monitoring, and control in labs and other areas:</p>
<ul>
<li>Hospitals blood/Tissue banks</li>
<li>Warehouses</li>
<li>Laboratories</li>
<li>Computer rooms</li>
<li>Chambers /incubator</li>
<li>Clean rooms</li>
<li>Green house</li>
<li>Electronics manufacturing</li>
<li>Defense</li>
<li>Refrigerators/Freezers</li>
<li>Other Critical areas</li>
</ul>
<p><strong>Authorised Australian distributor</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-186d-co2-meter-with-temperature-and-data-logging/">Tenmars TM-186D CO2 Meter with Temperature and Data Logging</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Tenmars TM-186D Meter Features:</h4>
<div class="pDetailsBody">Large LED display<br />
Measurement: CO2, temperature<br />
The selection of oC or oF<br />
Real time data<br />
Data Hold function<br />
Alarm function</div>
<div class="pDetailsBody"></div>
<div class="pDetailsBody">
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="800" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085AA5"><span style="color: #ffffff; font-size: medium;">Tenmars TM-186D Specifications</span></td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Display</td>
<td bgcolor="#E7F7FF">Large LED dual display</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">CO2 Maximum Reading</td>
<td bgcolor="#E7F7FF">9999</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Temperature Maximum Reading</td>
<td bgcolor="#E7F7FF">999</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">CO2 Sensor</td>
<td bgcolor="#E7F7FF">Infrared</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Temperature Sensor</td>
<td bgcolor="#E7F7FF">Diode</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Sampling Rate</td>
<td bgcolor="#E7F7FF">1 reading per second</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Resolution</td>
<td bgcolor="#E7F7FF">1ppm, 0.1<span style="font-family: Verdana;">°C, 0.1°F</span></td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<div align="center">
<table border="1" width="800" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085AA5"><span style="color: #ffffff; font-size: medium;">Tenmars TM-186D General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Power Supply</td>
<td bgcolor="#E7F7FF">9 Volt battery and or AC to DC adapter</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Backup Power</td>
<td bgcolor="#E7F7FF">9 Volt battery, NEDA 1604, IEC 6F22 or JIS 006P (for Datalogger use)</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Operating Temperature</td>
<td bgcolor="#E7F7FF">-20<span style="font-family: Verdana;">°C to 70°C</span></td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Storage Temperature</td>
<td bgcolor="#E7F7FF">-10<span style="font-family: Verdana;">°C to 60°C</span></td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Dimensions</td>
<td bgcolor="#E7F7FF">260mm (L) x 178mm (W) x 47mm (D)</td>
</tr>
<tr>
<td bgcolor="#E7F7FF" width="231">Weight</td>
<td bgcolor="#E7F7FF">100g</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>Maintenance</p>
<p>a Do not use the meter in an environment with severe change; do not store the unit in an environment with high temperature, high humidity, and high vibration. Take the battery off if the meter has not been used for a long period of time. The Diode temperature probe is used to measure temperature and the capacitive humidity sensor is used to measure take humidity. The thermocouple and humidity sensor will start aging under the influence of oxidation, reduction, corrosion, pollution, vaporization, diffusion or other metallurgy. The aging process will affect its precision seriously. Cleaning and inspection of temperature probe: The smoke, coal, dust, grease attached on the protective tube of temperature probe will slow down the heat conduction of the thermocouple and cause measuring error. Therefore, it should be cleaned periodically. The metal coating of thin thermocouple should be replaced properly upon the occurrence of corrosion.</p>
<p>Cleaning and inspection of humidity sensor: The smoke and dust attached on the humidity sensor will slow down the function of humidity sensor and cause measuring error. Therefore, it should be cleaned periodically. Blow off the dust with mild compressed air instead of water or alcohol. The aluminum plate inside the humidity sensor should be replaced upon the occurrence of corrosion.</p>
</div>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-186d-co2-meter-with-temperature-and-data-logging/">Tenmars TM-186D CO2 Meter with Temperature and Data Logging</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/tenmars-tm-186d-co2-meter-with-temperature-and-data-logging/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>