<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>clamp Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-tag/clamp/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-tag/clamp/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Sun, 23 Jan 2022 07:16:21 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>clamp Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-tag/clamp/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>PROVA CM-05 AC/DC Current Probe</title>
		<link>https://obiat.com.au/product/prova-cm-05-acdc-current-probe/</link>
					<comments>https://obiat.com.au/product/prova-cm-05-acdc-current-probe/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 29 May 2016 21:36:44 +0000</pubDate>
				<guid isPermaLink="false">http://obiat.com.au/?post_type=product&#038;p=3675</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-839" src="http://obiat.com.au/wp-content/uploads/2016/02/Prova_Logo.gif" alt="Prova_Logo" width="154" height="52" /></p>
<h5><span style="font-size: large;">PROVA CM-05 Features:</span></h5>
<ul>
<li>Accurate AC/DC current probe for current measurements.</li>
<li>10mA DC, and 1mA AC resolution<span style="font-family: Verdana;">.</span></li>
<li><span style="font-family: Verdana;">One touch zero for AC amps adjustment.</span></li>
<li>Jaw opening: 23mm diameter.</li>
<li>Easy single rotary switch for any function selection.</li>
<li>Connect to an oscilloscope for waveform observation.</li>
<li>Connect to a data logger or DMM for recording or measurement.</li>
<li>CAT II 600V, CAT III 300V.</li>
<li><span style="font-family: Verdana;">Accessories supplied with instrument: Two 1.5 volt batteries (installed), User's Manual, Test Leads, and Carrying Bag.</span></li>
</ul>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline;"><a href="http://obiat.com.au/wp-content/uploads/2016/05/Prova-1_CM-05_Datasheet.pdf" target="_blank">Prova CM-05 Datasheet</a></span></h5>
<p>The post <a href="https://obiat.com.au/product/prova-cm-05-acdc-current-probe/">PROVA CM-05 AC/DC Current Probe</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table width="615">
<tbody>
<tr>
<td colspan="3" width="412"><strong>PROVA CM-05 Electrical Specifications: (23℃±5℃)</strong></td>
<td width="203"></td>
</tr>
<tr>
<td width="203"><strong>Range</strong></td>
<td colspan="2" width="209"><strong>Output</strong></td>
<td width="203"><strong>Accuracy</strong></td>
</tr>
<tr>
<td width="203">DCA 0-4A</td>
<td colspan="2" width="209">DC 100mV/A</td>
<td width="203">±2.0%±0.005A</td>
</tr>
<tr>
<td width="203">DCA 0-40A</td>
<td colspan="2" width="209">DC 10mV/A</td>
<td width="203">±1.0%±0.02A</td>
</tr>
<tr>
<td width="203">DCA 0-150A</td>
<td colspan="2" width="209">DC 1mV/A</td>
<td width="203">±1.0%±0.2A</td>
</tr>
<tr>
<td width="203">DCA 150-200A</td>
<td colspan="2" width="209">DC 1mV/A</td>
<td width="203">-2.2%±0.2A</td>
</tr>
<tr>
<td width="203">ACA 0-4A</td>
<td colspan="2" width="209">AC 100mV/A</td>
<td width="203">±2.0%±0.005A (40-1KHz)</td>
</tr>
<tr>
<td width="203">ACA 0-40A</td>
<td colspan="2" width="209">AC 10mV/A</td>
<td width="203">±1.5%±0.03A (40-1KHz)</td>
</tr>
<tr>
<td width="203">ACA 0-150A</td>
<td colspan="2" width="209">AC 1mV/A</td>
<td width="203">±1.5%±0.3A (40-1KHz)</td>
</tr>
<tr>
<td width="203">ACA 150-200A</td>
<td colspan="2" width="209">AC 1mV/A</td>
<td width="203">-2.2%±0.3A (40-1KHz)</td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2" width="315"><strong>Range</strong></td>
<td colspan="2" width="300"><strong>Sensitivity</strong></td>
</tr>
<tr>
<td colspan="2" width="315">DCA 0-4A</td>
<td colspan="2" width="300">0.1mV/1mADC</td>
</tr>
<tr>
<td colspan="2" width="315">DCA 0-40A</td>
<td colspan="2" width="300">0.1mV/10mA DC</td>
</tr>
<tr>
<td colspan="2" width="315">DCA 0-200A</td>
<td colspan="2" width="300">0.1mV/100mA DC</td>
</tr>
<tr>
<td colspan="2" width="315">ACA 0-4A</td>
<td colspan="2" width="300">0.1mV/1mA AC</td>
</tr>
<tr>
<td colspan="2" width="315">ACA 0-40A</td>
<td colspan="2" width="300">0.1mV/10mA AC</td>
</tr>
<tr>
<td colspan="2" width="315">ACA 0-200A</td>
<td colspan="2" width="300">0.1mV/100mA AC</td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td colspan="2"></td>
<td></td>
<td></td>
</tr>
</tbody>
</table>
<table width="615">
<tbody>
<tr>
<td colspan="2" width="315"><strong>PROVA CM-05 General Specifications:</strong></td>
<td width="97"></td>
<td width="203"></td>
</tr>
<tr>
<td colspan="2" width="315">Conductor Size:</td>
<td colspan="2" width="300">23mm max. (approx.)</td>
</tr>
<tr>
<td colspan="2" width="315">Battery Type:</td>
<td colspan="2" width="300">two 1.5V SUM-3 AA</td>
</tr>
<tr>
<td colspan="2" width="315">Range Selection:</td>
<td colspan="2" width="300">manual</td>
</tr>
<tr>
<td colspan="2" width="315">Power Consumption:</td>
<td colspan="2" width="300">6 mA (approx.)</td>
</tr>
<tr>
<td colspan="2" width="315">Low battery Indication:</td>
<td colspan="2" width="300">red LED lights</td>
</tr>
<tr>
<td colspan="2" width="315">Operating Temperature:</td>
<td colspan="2" width="300">-10°C to 50°C</td>
</tr>
<tr>
<td colspan="2" width="315">Operating Humidity:</td>
<td colspan="2" width="300">less than 85% relative</td>
</tr>
<tr>
<td colspan="2" width="315">Altitude:</td>
<td colspan="2" width="300">up to 2000M</td>
</tr>
<tr>
<td colspan="2" width="315">Storage Temperature:</td>
<td colspan="2" width="300">-20°C to 60°C</td>
</tr>
<tr>
<td colspan="2" width="315">Storage Humidity:</td>
<td colspan="2" width="300">less than 75% relative</td>
</tr>
<tr>
<td colspan="2" width="315">Dimension:</td>
<td colspan="2" width="300">183mm (L) x 61.3mm (W) x 35.6mm (H)<br />
7.2&#8243; (L) x 2.5&#8243; (W) x 1.4&#8243; (H)</td>
</tr>
<tr>
<td colspan="2" width="315">Weight:</td>
<td colspan="2" width="300">190g (battery included)</td>
</tr>
<tr>
<td colspan="2" width="315">Accessories:</td>
<td colspan="2" width="300">Carrying bag x 1 Users manual x 1 1.5V battery x 2<br />
Test leads</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/prova-cm-05-acdc-current-probe/">PROVA CM-05 AC/DC Current Probe</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/prova-cm-05-acdc-current-probe/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>KYORITSU 2033  AC/DC 300 Amp Clampmeter</title>
		<link>https://obiat.com.au/product/kyoritsu-2033-acdc-300-amp-clampmeter/</link>
					<comments>https://obiat.com.au/product/kyoritsu-2033-acdc-300-amp-clampmeter/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 12 Apr 2016 08:08:58 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2694</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-27" src="http://obiat.com.au/wp-content/uploads/2015/12/Kyoritsu_Logo_main.gif" alt="Kyoritsu_Logo_main" width="146" height="25" /></p>
<p><span style="font-size: large;">Features</span></p>
<ul>
<li>The smallest clampmeter in the Kyoritsu range capable of AC and DC current measurements.</li>
<li>300 Amp auto ranging has minimum resolution of<br />
0.01A AC/DC.</li>
<li>Auto-zero function to allow one touch zero adjustment.</li>
<li>Included Accessories: Two (2) type LR44 1.5V Alkaline Batteries, Instruction Manual and Carrying Case.</li>
</ul>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2033-acdc-300-amp-clampmeter/">KYORITSU 2033  AC/DC 300 Amp Clampmeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table id="table49" border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td><span style="font-size: large;">KYORITSU 2033 Specification:</span></td>
</tr>
<tr>
<td>
<div align="center">
<table id="table51" border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td rowspan="2" valign="top" width="260"><b>AC Current</b></p>
<p>&nbsp;</td>
<td valign="top" width="111">0A to 40A<br />
20A to 200A<br />
200A to 300A</td>
<td width="110">50/60Hz</td>
<td valign="top">±1% of rdg ±4 dgts<br />
±1.5% of rdg ±4 dgts<br />
±3.5% of rdg</td>
</tr>
<tr>
<td width="111">0A to 40A<br />
20A to 200A<br />
200A to 300A</td>
<td width="110">20Hz to 1kHz</td>
<td>±2.5% of rdg ±4 dgts<br />
±2.5% of rdg ±4 dgts<br />
±4.0% of rdg</td>
</tr>
<tr>
<td valign="top" width="260"><b>DC Current</b></td>
<td width="111">0A to 40A<br />
20A to 200A<br />
200A to 300A</td>
<td width="110"></td>
<td valign="top">±1% of rdg ±4 dgts<br />
±1.5% of rdg ±4 dgts<br />
±3.0% of rdg</td>
</tr>
<tr>
<td width="260"><b>Conductor Size</b></td>
<td colspan="3">24mm maximum</td>
</tr>
<tr>
<td valign="top" width="260"><b>Safety Standard</b></td>
<td colspan="3">IEC 61010-1 CAT III 300V<br />
IEC 61010-2-032</td>
</tr>
<tr>
<td width="260"><b>Frequency Response</b></td>
<td colspan="3">DC, 20Hz to 1kHz</td>
</tr>
<tr>
<td width="260"><b>Withstand Voltage</b></td>
<td colspan="3">3700V AC for 1 minute</td>
</tr>
<tr>
<td width="260"><b>Power Source</b></td>
<td colspan="3">Two (2) type &#8216;AA&#8217; LR44 Alkaline 1.5V batteries</td>
</tr>
<tr>
<td width="260"><b>Dimensions</b></td>
<td colspan="3">147mm (L) x 59mm (W) x 25mm (D)</td>
</tr>
<tr>
<td width="260"><b>Weight</b></td>
<td colspan="3">100g approx.</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Note</strong> : ◇During current measurement, keep the KYORITSU 2033 transformer jaws fully closed. Otherwise,accurate measurement cannot be made. The maximum measurable conductor size is approx. 24mm in diameter. ◇Unlike in DC current measurement, zero adjustment is not necessary in AC current measurement. There is no polarity in the reading either.</p>
<p><strong> KYORITSU 2033 Sleep Function.</strong></p>
<p>This is a function to prevent the instrument from being left powered on in order to conserve battery life. This function causes the instrument to go into the Sleep (powered-down) mode about 5 minutes after the last switch or button operation. To exit the Sleep mode, turn the Function Selector switch back to &#8220;OFF&#8221;, then to any other position, or press any button.</p>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-2033-acdc-300-amp-clampmeter/">KYORITSU 2033  AC/DC 300 Amp Clampmeter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/kyoritsu-2033-acdc-300-amp-clampmeter/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
