<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Dataloggers Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-tag/dataloggers/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-tag/dataloggers/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Thu, 05 Feb 2026 21:41:44 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Dataloggers Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-tag/dataloggers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Kyoritsu 5020 TRMS Current / Voltage Data Logger</title>
		<link>https://obiat.com.au/product/kyoritsu-5020-trms-current-voltage-data-logger/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 17 Sep 2018 02:12:49 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=17333</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p class="short-description mhide ipad-view-setting">The Kyoritsu 5020 TRMS Current/Voltage Data Logger has three input channels for the simultaneous recording of load current and voltage.</p>
<p class="short-description mhide ipad-view-setting">Various measurements are available with four recording modes: Normal, Trigger, Capture and Power Quality Analysis.</p>
<p>The Kyoritsu 5020 data logger is capable of storing up to 60,000 measurements and features non-volatile memory that allows recorded data to be retained even if power is lost.</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-5020-Datasheet.pdf" rel="noopener">Kyoritsu-5020-Datasheet</a></span></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-5020-User-Manual.pdf" rel="noopener">Kyoritsu-5020-User-Manual</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-5020-trms-current-voltage-data-logger/">Kyoritsu 5020 TRMS Current / Voltage Data Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Kyoritsu 5020 TRMS 3-Channel Current / Voltage Data Logger Features:</h3>
<div class="row"  id="row-710409086">

	<div id="col-1441911739" class="col medium-2/3 large-8"  >
				<div class="col-inner"  >
			
			
<ul>
<li>Power Quality Analysis: Reference voltage, Swell, Dip, Short power Interruptions.</li>
<li>Variation of the measured voltage and current data can be confirmed simultaneously on the PC display monitor.</li>
<li>Large capacity for storing 60,000 data points when 1 channel is used, and when all the three channels are used, 20,000 data points per channel can be recorded.</li>
<li>Lowpass Filter will filter out the harmonics (cutoff frequency = approx. 160Hz)</li>
<li>LED flickers when the preset current / voltage value is exceeded</li>
</ul>
		</div>
					</div>

	

	<div id="col-194359493" class="col medium-1/3 large-4"  >
				<div class="col-inner"  >
			
			
<a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020_01.jpg"><img decoding="async" class="alignnone wp-image-7664" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020_01.jpg" alt="" width="164" height="183" /></a><br />
		</div>
					</div>

	
</div>
<ul>
<li>The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)</li>
<li>The last 10 recorded data points including time/date can be recalled on the logger display</li>
<li>Selection of One-time mode or Endless mode:<br />
One-time on: Recording will stop when memory is used up<br />
One-time off: Overwrite the old data, and store the latest data</li>
<li>Non Volatile Memory: Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)</li>
<li>Battery power indicator: Indicates battery voltage in 4-levels (It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)</li>
<li>User-friendly PC software &#8220;KEW LOG Soft 2&#8221; is supplied</li>
<li>Permits editing, analysis and graphical display of data.</li>
<li>Recorded data is downloadable onto a PC via USB cable.</li>
<li>Simplified Power Integration: (The &#8220;KEW LOG Soft 2&#8221; uses current and voltage recorded to calculate the integral power consumption).</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes.jpg"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-7662" src="https://rapid-tech.com.au/wp-content/uploads/2018/05/Kyoritsu-5020-Recording-Modes.jpg" alt="" width="945" height="783" /></a></p>
<h4><span style="font-size: 110%;">Kyoritsu 5020 TRMS 3-Channel Data Logger Specifications:</span></h4>
<div class="editor">
<p>Normal Recording Mode<br />
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>RMS Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±2.0%rdg±0.9%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±1.5%rdg±0.7%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Crest Factor</td>
<td>2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.</td>
</tr>
</tbody>
</table>
</div>
<p>*Max, Min and Instant Peak values in Normal Recording mode are just reference values:<br />
their accuracies aren&#8217;t guaranteed.</p>
<p>Trigger Recording Mode (AC 50/60Hz sine wave)</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±3.5%rdg±2.2%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±3.0%rdg±2.0%f.s.+ Accuracy of Sensor</td>
</tr>
</tbody>
</table>
</div>
<p>Capture Recording Mode</p>
<div class="tableScroller">
<table>
<tbody>
<tr>
<th>Range</th>
<th>Accuracy</th>
</tr>
<tr>
<td>100.0mA</td>
<td>±3.0%rdg±1.7%f.s.+ Accuracy of Sensor</td>
</tr>
<tr>
<td>Other ranges</td>
<td>±2.5%rdg±1.5%f.s.+ Accuracy of Sensor</td>
</tr>
</tbody>
</table>
</div>
</div>
<section class="mb10">
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Recording mode</th>
<td>Normal, Trigger, Capture, Power Quality Analysis</td>
</tr>
<tr>
<th>Operating system</th>
<td>Successive Approximation<br />
(CH1 single synchronized sampling)</td>
</tr>
<tr>
<th>Rated max. working voltage</th>
<td>AC 9.9Vrms, 14V peak value</td>
</tr>
<tr>
<th>Number of input channel</th>
<td>3ch</td>
</tr>
<tr>
<th>Measuring method</th>
<td>True RMS</td>
</tr>
<tr>
<th>RMS measuring interval</th>
<td>approx. 100ms</td>
</tr>
<tr>
<th>Sampling interval</th>
<td>Normal/Trigger mode : approx. 1.65ms/CH<br />
Capture mode : approx. 0.55ms (waveform: at every 1.1ms)<br />
P.Q.A. mode : approx. 0.55ms</td>
</tr>
<tr>
<th>Low battery warning</th>
<td>Battery mark display (in 4 levels)</td>
</tr>
<tr>
<th>Over-range indication</th>
<td>&#8220;OL&#8221; mark is displayed when exceeding the measuring range</td>
</tr>
<tr>
<th>Auto power off</th>
<td>Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)</td>
</tr>
<tr>
<th>Possible measurement time</th>
<td>Approx. 10 days (with alkaline LR6 batteries)</td>
</tr>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1:2001 CAT III 300V Pollution degree2<br />
IEC 61326 (EMC standard)</td>
</tr>
<tr>
<th>Dimensions</th>
<td>111(L)×60(W)×42(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>Approx. 265g</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>Alkaline battery LR6×4pcs, 9118 (Carrying case)<br />
PC software &#8220;KEW LOG Soft 2&#8221;, 7148 (USB cable)<br />
Instruction manual, Quick manual, Install manual,<br />
USB Notice sheet</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>8146/8147/8148 (Leakage &amp; Load current Clamp Sensor),<br />
8121/8122/8123 (Load current Clamp Sensor),<br />
8129/8130 (Flexible Clamp Sensor),<br />
8309 (Voltage Sensor: only KEW 5020), 8320 (AC Adapter),<br />
9135 (Carrying bag), 9119 (Hard carry case),<br />
7185 (Extension cable for sensor)</td>
</tr>
</tbody>
</table>
</div>
</section>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-5020-trms-current-voltage-data-logger/">Kyoritsu 5020 TRMS Current / Voltage Data Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Extech DL160 True RMS AC Voltage/Current Datalogger</title>
		<link>https://obiat.com.au/product/extech-dl160-true-rms-ac-voltagecurrent-datalogger/</link>
					<comments>https://obiat.com.au/product/extech-dl160-true-rms-ac-voltagecurrent-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 10 Oct 2016 04:37:25 +0000</pubDate>
				<guid isPermaLink="false">http://obiat.com.au/?post_type=product&#038;p=3980</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1918" src="http://obiat.com.au/wp-content/uploads/2016/03/Extech-logo.jpg" alt="Extech logo" width="200" height="61" /></p>
<h4>Extech DL160 Features</h4>
<ul>
<li>Simultaneously measure two AC Voltages <strong>or</strong> two AC Currents <strong>or</strong> one AC Voltage and one AC Current input</li>
<li>Readings can be downloaded to your PC via the USB interface and analysed using the included software or exported to a spreadsheet</li>
<li>LCD indicates time/date, current readings and Min/Max</li>
<li>Auto Power off and battery check</li>
<li>Comes complete with 2 Current and Voltage sensor modules, two sets of test leads and alligator clips, USB cable, Windows® software, AC Adaptor and battery</li>
</ul>
<p><img class="alignnone size-full wp-image-2454" src="http://obiat.com.au/wp-content/uploads/2016/04/CAT-III.jpg" alt="CAT III" width="46" height="33" />    <img class="alignnone size-full wp-image-2451" src="http://obiat.com.au/wp-content/uploads/2016/04/Capture-2.jpg" alt="CE" width="37" height="30" />    <img class="alignnone size-full wp-image-2450" src="http://obiat.com.au/wp-content/uploads/2016/04/1-Year.jpg" alt="1 Year" width="67" height="35" /></p>
<p><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://obiat.com.au/wp-content/uploads/2016/10/DL160data.pdf">DL160 Datasheet</a></p>
<p><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <a target="_blank" href="http://obiat.com.au/wp-content/uploads/2016/10/DL160_UM.pdf">DL160 User Manual</a></p>
<p>The post <a href="https://obiat.com.au/product/extech-dl160-true-rms-ac-voltagecurrent-datalogger/">Extech DL160 True RMS AC Voltage/Current Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h5><strong>EXTECH DL160 Dual Input True RMS AC Voltage/Current Datalogger</strong></h5>
<p>The EXTECH DL160 is capable of datalogging 2 channels simultaneously — up to 256,000 readings of TRMS AC Voltage (600 volts) or Current (200 amp) or one AC Voltage and one AC Current input with a user programmable sample rate from 1 second to 24 hours.</p>
<p><strong>EXTECH DL160 Additional Features:</strong></p>
<p>LCD displays shows time/date, current reading, and min/max. Readings can be downloaded to your PC via the USB interface. Normal, peak, and capture (user specified trigger level) recording modes.</p>
<h5>Extech DL160 Specifications:</h5>
<p>&nbsp;</p>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccelltitle" width="200">Display</td>
<td class="speccelldata" colspan="2">Multi-function LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Maximum data points</td>
<td class="speccelldata" colspan="2">256,000 values</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Channels</td>
<td class="speccelldata" colspan="2">dual channel, TRMS AC voltage or Current</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Sample rate</td>
<td class="speccelldata" colspan="2">1s to 24h selectable</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Analysis software</td>
<td class="speccelldata" colspan="2">2000/XP/Vista</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Data Output</td>
<td class="speccelldata" colspan="2">USB port</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Current Clamp Jaw Opening</td>
<td class="speccelldata" colspan="2">12.7mm (0.5&#8243;)</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Open input indicatio</td>
<td class="speccelldata" colspan="2">&#8220;LO&#8221; appears on LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Low battery indication</td>
<td class="speccelldata" colspan="2">Empty battery symbol appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Power supply</td>
<td class="speccelldata" colspan="2">4 AAA Batteries and 1 CR 3V memory button battery (CR2032 or equivalent)</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Battery life</td>
<td class="speccelldata" colspan="2">5 days (approximately)</td>
</tr>
<tr>
<td class="speccelltitle" width="200">AC Adaptor</td>
<td class="speccelldata" colspan="2">9V, 0.5A</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Standards</td>
<td class="speccelldata" colspan="2">CE, CAT III 600V, for inside use, maximum height 2000 meters</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Operating Temperature</td>
<td class="speccelldata" colspan="2">0 to 50°C, -32 to 122°F</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Operating Humidity</td>
<td class="speccelldata" colspan="2">&lt;70% RH</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Storage Temperature</td>
<td class="speccelldata" colspan="2">-20°C to 60°C</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Storage Humidity</td>
<td class="speccelldata" colspan="2">&lt;80% relative humidity</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Dimensions</td>
<td class="speccelldata" colspan="2">114 x 63 x 34mm</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Weight</td>
<td class="speccelldata" colspan="2">248g</td>
</tr>
<tr>
<td class="speccellcategory" width="170">Function</td>
<td class="speccellcategory" width="200">Range</td>
<td class="speccellcategory">Accuracy</td>
</tr>
<tr>
<td class="speccelltitle" width="170">Voltage (40Hz to 1kHz)</td>
<td class="speccelldata" width="200">10VAC to 600.0VAC</td>
<td class="speccelldata">±2.0%±1V</td>
</tr>
<tr>
<td class="speccelltitle" width="170">Current (50/60Hz)</td>
<td class="speccelldata" width="200">10A to 200.0A</td>
<td class="speccelldata">±2.0%±1A</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/extech-dl160-true-rms-ac-voltagecurrent-datalogger/">Extech DL160 True RMS AC Voltage/Current Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/extech-dl160-true-rms-ac-voltagecurrent-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</title>
		<link>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/</link>
					<comments>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 12 Jul 2016 08:14:50 +0000</pubDate>
				<guid isPermaLink="false">http://obiat.com.au/?post_type=product&#038;p=3846</guid>

					<description><![CDATA[<p><a href="http://obiat.com.au/wp-content/uploads/2017/10/HT-Italia-Aus-small.jpg"><img class="alignnone size-full wp-image-4270" src="http://obiat.com.au/wp-content/uploads/2017/10/HT-Italia-Aus-small.jpg" alt="HT-Italia-Aus-small" width="192" height="100" /></a></p>
<h4><strong>The GSC60 is a Multifunction Professional Electrical Analyzer.</strong></h4>
<h4><strong><span style="color: #ed1c24;">No other instrument can match it's versatility.</span></strong></h4>
<p><span style="color: #ff0000;"><strong>NOTE:</strong></span> <strong>This is the Australian version with the correct wiring colours and C Tick certification.</strong></p>
<h5><strong>The GSC60 Measures:</strong></h5>
<ul>
<li><strong>Power Quality</strong> - 9 types of Electrical Systems (both single &#38; 3 phase)</li>
<li><strong>Installation Testing</strong></li>
<li><strong>Earth Resistance</strong> - 2 or 3 Pole</li>
<li><strong>Soil Resistivity</strong> - 4 pole Wenner method</li>
<li><strong>RCD Testing</strong> - A, AC &#38; B</li>
<li><strong>Insulation Resistance</strong> - up to 1000V</li>
<li><strong>Continuity</strong> - test currents up to 200mA</li>
<li><strong>Advanced Loop Testing</strong></li>
<li><strong>Phase Sequence</strong></li>
<li><strong>Leakage Current</strong></li>
<li><strong>Cat IV Safety Rating</strong></li>
</ul>
<h5><img class="alignnone size-full wp-image-3188" src="http://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="PDF Logo" width="58" height="58" />    <span style="text-decoration: underline; color: #0000ff;"><strong><a href="http://obiat.com.au/wp-content/uploads/2016/07/GSC60-Brochure.pdf">GSC60 Brochure</a></strong></span></h5>
<h5><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />    <span style="text-decoration: underline;"><span style="color: #0000ff;"><a target="_blank" href="http://obiat.com.au/wp-content/uploads/2016/07/GSC60-User-Manual.pdf" rel="noopener noreferrer">GSC60 User Manual</a></span></span></h5>
<p>The post <a href="https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/">HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>The HT INSTRUMENTS GSC60 &#8211; One instrument for all electrical safety tests.</strong></h2>
<p><iframe width="1020" height="574" src="https://www.youtube.com/embed/7LqND-OF0jc?feature=oembed" frameborder="0" allow="accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture" allowfullscreen></iframe></p>
<h2><strong><span style="color: #f99b1c;">MEASURES:</span></strong></h2>
<p><strong>›    </strong><strong>Earth</strong> <strong>Resistance</strong> with 2- or 3-pole <strong>volt-ampere method </strong>in TT, TN and IT systems, <strong>non-trip earth loop impedance measurement</strong>, <strong>stackless earth ground resistance measurement  </strong>with T2100 (optional).</p>
<p><strong>›    </strong><strong>Soil</strong> <strong>Resistivity</strong> with <strong>4 pole </strong>Wenner method.</p>
<p><strong>›    </strong><strong>RCD</strong> <strong>Testing</strong> <strong>type</strong> A, AC, B with test current up to 10A.**</p>
<p><strong>›    </strong><strong>Insulation</strong> <strong>Resistance</strong> measurement with test voltage <strong>up</strong> <strong>to</strong> <strong>1000V</strong>.</p>
<p><strong>›    </strong><strong>Continuity </strong>measurement of protective conductors with test current <strong>up to 200mA</strong>.</p>
<p><strong>›    </strong><strong>Advanced </strong><strong>Loop </strong>Testing of MCBs, fuses and cable sizing.</p>
<p><strong>›    </strong>Measurement of <strong>phase sequence (SEQ)</strong>.</p>
<p>›    Measurement and recording of environment parameters and leakage currents through external probes.</p>
<h2><span style="color: #f99b1c;"><strong>HT INSTRUMENTS GSC60 for the Analysis of Power Quality and Energy Consumption.</strong></span></h2>
<p><strong>›    </strong><strong>9 types of electrical systems: </strong>1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.</p>
<p><strong>›    </strong><strong>632</strong> <strong>parameters</strong> <strong>can</strong> <strong>be</strong> <strong>recorded</strong> <strong>for</strong> <strong>over</strong> <strong>two</strong> <strong>months</strong>.</p>
<p><strong>›    </strong><strong>Real</strong> <strong>Time</strong>. Real-time display of all <strong>waveforms</strong>, <strong>harmonics</strong>, <strong>vector</strong> <strong>diagrams</strong> as well as <strong>summary</strong> <strong>function </strong>on phases for a <strong>quick reading </strong>of the most important parameters.</p>
<p><strong>›    </strong><strong>Voltage</strong> <strong>Anomalies</strong>. Detection of voltage anomalies with a resolution of <strong>20ms</strong>.</p>
<p><strong>›    </strong><strong>Energy</strong> <strong>Saving.</strong> <strong>One</strong> <strong>click</strong> <strong>allows</strong> <strong>you</strong> <strong>to</strong> <strong>check</strong> <strong>all</strong> <strong>the</strong> <strong>electrical</strong> <strong>absorption</strong> of all the equipment connected to the main power supply and save on energy costs.</p>
<h2><span style="color: #f99b1c;">Live. Real Time Analysis.</span></h2>
<p>Wi-Fi connection allows you to display wave forms, vector diagrams, harmonics and all electrical parameters for each phase on your tablet/smartphone/PC</p>
<p>GSC60 helps to dispel the myth that recording analysis is complex. App HTanalysis makes it simple and clear. Using ZOOM Functions you can display all the recorded quantities. JUMP Function displays harmonics in any recording step just by clicking on the quantity.</p>
<h2><span style="color: #f99b1c;"><strong>HT INSTRUMENTS GSC60 Functions:</strong></span></h2>
<div class="mm-page mm-slideout">
<div class="container-body center-block">
<div class="pg-opt prodotti">
<div class="container-fluid">
<div class="row">
<div class="col-md-12">
<section class="slice bg-greyprod">
<div class="container">
<div class="tab-content">
<div id="tab-2" class="tab-pane fade active in">
<div class="tab-body prodotti">
<div class="list-check">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr class="list-item">
<td class="function thin-font">   <span style="color: #000000;"> Touchscreen colour display</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Integrated WiFi connection and compatibility with HTANALYSIS App</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Continuity of protective circuit with 200mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Insulation with voltage 50, 100, 250, 500, 1000VDC</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Time/Current tripping of type B RCDs up to 300mA</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Line/Loop impedance with high resolution (with optional accessory IMP57)</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Percentage voltage drop on the line</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #000000;">     Measurement and recording of leakage currents and environment parameters</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><strong> Three-phase Power quality and Energy consumption analysis:</strong><br />
♦  <span style="color: #282828;"> 9 types of electrical systems:</span><br />
<span style="color: #282828;"> ♦   1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     632 parameters can be recorded for over two months</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage Anomalies (dips and peaks) with a resolution of 20ms @ 50Hz</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Active, Reactive, Apparent Power</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Active, Reactive, Apparent Energy</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/recording of Cosphi, Power Factor</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Measurement/Recording of Voltage and Current Harmonics up to 49th with THD%</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage/current vector diagram</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Voltage/current waveforms</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Tables or histograms of Harmonics and THD%</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Summary table of main electric parameters</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Help on line on the display</span></td>
</tr>
</tbody>
<tbody class="thin-font">
<tr class="list-item">
<td class="function"><span style="color: #282828;">     Protection category &#8211; CAT IV</span></td>
</tr>
</tbody>
</table>
</div>
<div></div>
<div class="list-check"><strong style="font-size: 20.16px;"><span style="color: #f99b1c;">GSC60 Standard Accessories:</span></strong></div>
</div>
</div>
</div>
<p>• HTFLEX33E AC flexible clamp for currents up to 3000A, diameter 174mm, 4 pieces<br />
• C2033X 3-banana to Shuko plug cable<br />
• UNIVERSALKITG3 Set of 4 cables, 4 alligator clips and 3 test leads<br />
• KITTERRNE Soft carrying bag containing 4 cables and 4 earth rods<br />
• PR400 Remote switch probe<br />
• PT400 Stylus<br />
• BORSA2051 Soft carrying bag<br />
• TOPVIEW2006 PC software and optical-to-USB connection cable C2006<br />
• YABAT0003000 Rechargeable NiMH battery 1.2V, AA, 6 pcs<br />
• A0060 Power Supplier\Battery Charger 100/230Vac &#8211; 15Vdc, 10W CAT IV<br />
• C7051 Power cable Shuko-Europlug ground-less 1.50mt<br />
• SP-5100 Hands Free kit<br />
• Quick user’s guide<br />
• User’s manual on CD-ROM<br />
• Calibration certificate ISO9000</p>
</div>
</section>
</div>
</div>
</div>
</div>
</div>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/">HT INSTRUMENTS GSC60 Professional Electrical Power Analyzer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-instruments-gsc60-professional-electrical-analyzer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Extech SDL200 4-Channel Thermometer Datalogger</title>
		<link>https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/</link>
					<comments>https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 24 Apr 2016 11:02:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=3002</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1918" src="http://obiat.com.au/wp-content/uploads/2016/03/Extech-logo.jpg" alt="Extech logo" width="200" height="61" /></p>
<p>Four-channel data logging thermometer accepts both thermocouple and RTD probes. Data is recorded onto a standard SD memory card, instead of a built-in memory; the advantage being that when the memory is full the SD card can be simply changed out for unlimited data storage.</p>
<p>The removable SD card is easy to transport and insert into a computer’s memory card slot or SD card reader for upload. The data is provided in Excel, allowing you to easily analyze the information without the need for additional software. Data can also be streamed directly to a computer using the RS-232 port on the meter.</p>
<ul>
<li class="deck"><span class="blacktext">Records data onto an SD card in Excel® format for easy transfer to a PC for analysis</span></li>
</ul>
<ul>
<li class="bullet"><span class="blacktext">Data logging capability up to 20,000 records using a 2G SD card</span></li>
</ul>
<ul>
<li class="bullet"><span class="blacktext">User programmable sampling rate from 1 to 3600 seconds</span></li>
</ul>
<ul>
<li class="bullet"><span class="blacktext">Manual store and recall of up to 99 records</span></li>
</ul>
<ul>
<li class="bullet"><span class="blacktext">Records readings with real-time/date stamp</span></li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/04/SDL200_UM.pdf" target="_blank" rel="">Extech SDL200 User Manual</a></p>
<p>The post <a href="https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/">Extech SDL200 4-Channel Thermometer Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Extech SDL200 4-Channel Thermometer SD Logger</h4>
<p>The Extech SDL200 displays and stores temperature readings from up to four (4) Type K, J, T, E, R, or S thermocouple temperature probes and two (2) Pt100 RTD probes. Logged data readings are stored on an SD card for transfer to a PC. In addition, an RS232 port allows data streaming to a PC. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.</p>
<h4>Extech SDL200 Features:</h4>
<ul>
<li>4-Channel datalogging with 6 Thermocouple types (J, K, E, T, R,S) and 2-Channel datalogging with RTD (Pt100Ω) probes</li>
<li>Displays [T1, T2, T3, T4] or differential [T1-T2] reading</li>
<li>Offset adjustment used for zero function to make relative measurements</li>
<li>Stores 99 readings manually and 20M readings via 2G SD card</li>
<li>Records readings with real date and time stamp</li>
<li>User programmable sampling rate: 1 to 3600 seconds</li>
<li>Min/Max and Data Hold functions</li>
<li>Auto power off with disable function</li>
<li>Built-in PC interface</li>
<li>Complete with 6 AA batteries, four general purpose Type K bead wire temperature probes, SD card, and hard carrying case</li>
</ul>
<h3>Extech SDL200 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">General Specifications</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type J</td>
<td class="speccelldata" align="center">-148 to 2192°F (-100 to 1200°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type K</td>
<td class="speccelldata" align="center">-148 to 2372°F  (-100 to 1300°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type T</td>
<td class="speccelldata" align="center">-58 to 752°F   (-50 to 400°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type E</td>
<td class="speccelldata" align="center">-58 to 1652°F   (-50 to 900°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type R</td>
<td class="speccelldata" align="center">32 to 3092°F   (0 to 1700°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type S</td>
<td class="speccelldata" align="center">32 to 2732°F   (0 to 1500°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">RTD (Pt100)</td>
<td class="speccelldata" align="center">-327 to 1562°F   (-200 to 850°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Resolution</td>
<td class="speccelldata" align="center">0.1°/1°</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Basic Accuracy</td>
<td class="speccelldata" align="center">±0.4% rdg (+1.8°F/+1°C) Types J,K,E,T, Pt100 ±0.5% rdg (+2°F/+1°C) Types R,S</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Datalogging</td>
<td class="speccelldata" align="center">20M data records using a 2G SD card</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Dimensions</td>
<td class="speccelldata" align="center">182 x 73 x 47.5mm</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Weight</td>
<td class="speccelldata" align="center">500g</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/">Extech SDL200 4-Channel Thermometer Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</title>
		<link>https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:58:07 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2845</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<p>The XL424 is a 3 phase Voltage data logger that is capable of performing measurements and recordings of TRMS AC voltage up to 600V. It has a sophisticated memory algorithm allowing it to record for up to 90 days</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/">HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL424 can perform measurements and recording of True-Rms AC voltage up to 600 volts in a three phase three-wire system. Applications include evaluation of network voltages and unbalanced loads etc. The instrument is contained in a safety IP65 case with built-in test leads and safety alligator clips for voltage measurements. The system can record for a very long time, up to around 90 days. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<h4><span style="font-size: large;">HT Italia XL424 Functions:</span></h4>
<ul>
<li>True-rms AC voltage measurement up to 600V.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Set of two alligator clips, KITXL423C.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
<table id="table88" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">0 Volts to 600 Volts</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">0.1 Volt</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(1.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><i>Note: meter consider null readings &lt; 2 volts</i></td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
1.5 days/1 sec; 8 days/6 sec; 42 days/30 sec; 91 days/1 min;<br />
455 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">120mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Test Lead Length</td>
<td bgcolor="#C0C0C0">2.6 meters</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/">HT Italia XL424 True-Rms AC Three-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl424-true-rms-ac-three-phase-voltage-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</title>
		<link>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:52:46 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2843</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<p>The HT Italia XL423 is a single phase voltage date logger capable of performing measurements and recordings of TRMS AC voltage up to 600V. It has a sophisticated memory algorithm which allows it to record for up to 1 year.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/">HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL423 can perform measurements and recording of True-Rms AC voltage up to 600 volts in a single phase system. Applications include evaluation of network voltages and unbalanced loads etc. The instrument is contained in a safety IP65 case with built-in test leads and safety alligator clips for voltage measurements. The system can record for a very long time, up to around a year. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<table id="table77" border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td valign="top" width="42%">
<h4><span style="font-size: large;">HT Italia XL423 Functions:</span></h4>
<ul>
<li>True-rms AC voltage measurement up to 600V.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<p>&nbsp;</p>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Set of two alligator clips, KITXL423C.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
</td>
</tr>
<tr>
<td colspan="2" valign="top" width="79%">
<div align="center">
<table id="table80" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">0 Volts to 600 Volts</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">0.1 Volt</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(1.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><i>Note: meter consider null readings &lt; 2 volts</i></td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
5 days/1 sec; 34 days/6 sec; 170 days/30 sec; 364 days/1 min;<br />
1820 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">120mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Test Lead Length</td>
<td bgcolor="#C0C0C0">2.6 meters</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/">HT Italia XL423 True-Rms AC  Single-Phase Voltage Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl423-true-rms-ac-single-phase-voltage-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL421 True-Rms AC  Single-Phase Current Logger</title>
		<link>https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:45:28 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2841</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<div class="product-meta">
<div class="product-description">
<p>The HT Italia XL421 is a single phase current data logger capable of performing TRMS AC current measurements and recordings up to 2500A. It has a sophisticated memory algorithm which permits the instrument to record for up to a year.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
</div>
</div>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/">HT Italia XL421 True-Rms AC  Single-Phase Current Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT Italia XL421 can perform measurements and recording of True-Rms AC current up to 2500 amps in a single phase system. Applications include evaluation of load consumption, verification of nominal power of transformer, etc. The instrument is contained in a safety IP65 case with built-in flexible clamp which is easily connected to a variety of cable and bus-bar sizes. The system can record for a very long time, up to around a year. With DATALINK Windows software supplied with the model, the recorded data is easily downloaded to a PC for analysis<span class="TXTSTANDARD">.</span></p>
<h4><span style="font-size: large;">HT Italia XL421 Functions:</span></h4>
<ul>
<li>True-rms AC current measurement up to 2500A.</li>
<li>Recording with sampling programmable period.</li>
<li>Manual activation of recording.</li>
<li>Low battery indication.</li>
<li>LED indication of any operation.</li>
<li>RS-232 interface.</li>
<li>Data maintained without batteries.</li>
<li>Programming with DATALINK software.</li>
</ul>
<p>&nbsp;</p>
<h4><span style="font-size: large;">Included Accessories</span></h4>
<ul>
<li>Inbuilt/integrated 3000 amp flexible current clamp, type HTFLEX33DL.</li>
<li>RS-232 serial cable, type C2004.</li>
<li>Adhesive Velcro for fixing.</li>
<li>Carrying bag, type BORSA2000.</li>
<li>User&#8217;s manual.</li>
</ul>
<table id="table72" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">2 amps to 2500 amps</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">1 amp</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(2.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Accuracy Error</td>
<td bgcolor="#C0C0C0">additional error due to not centering cable: 2% of reading</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
5 days/1 sec; 34 days/6 sec; 170 days/30 sec; 364 days/1 min;<br />
1820 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">129mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Conductor Diameter</td>
<td bgcolor="#C0C0C0">174mm</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/">HT Italia XL421 True-Rms AC  Single-Phase Current Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl421-true-rms-ac-single-phase-current-logger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HT Italia XL422 3-Phase Current Datalogger</title>
		<link>https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/</link>
					<comments>https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 17 Apr 2016 09:37:08 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2839</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-3842" src="http://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="HT Italia Logo" width="166" height="91" /></p>
<p>The XL422 is a 3 phase current data logger able to perform TRMS AC measurements and recordings of current up to 2500A. This instrument has a sophisticated memory algorithm which allows it to record for up to 1 year.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h5><img class="alignnone wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="153" height="48" /></h5>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/">HT Italia XL422 3-Phase Current Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>HT Italia XL422 Three-phase Current Data Logger</strong></p>
<p>The HT Italia XL422 performs measurements and records TRMS AC current up to 2500A in a generic three phase 3-wire system.</p>
<p>The XL422 is part of the HT Data Logger family which includes the following models: XL421, XL423 and XL424</p>
<p>These models can perform measurements and recordings of TRMS AC current up to 2500A from a generic single-phase system.</p>
<p>They can be very useful for various applications:</p>
<ul type="disc">
<li>evaluation of load consumption</li>
<li>verification of nominal power of the incoming supply</li>
</ul>
<p>The instrument is enclosed in a safe and practical case with a built-in flexible clamp enabling you to clamp-on to a cable or bar with wide dimensions.</p>
<p>Thanks to a sophisticated memory algorithm the instrument is able to record for a considerable time, up to about 1 year! (With a 60 sec integration period for single phase loggers and 5 min integration for 3 phase loggers dependant on battery life). It is also simple and straight forward to use.</p>
<p>With TOPVIEW2004 Windows software, supplied with the model, it’s possible to download and analyse all recorded data directly on your PC.</p>
<p>The high-protection (IP65) casing makes the instrument reliable to use in extreme environmental conditions.</p>
<h4><strong>HT Italia XL422 Function:</strong></h4>
<ul>
<li>TRMS AC current measure up to 2500A</li>
<li>Recording with sampling programmable period</li>
<li>Manual activation of recording</li>
<li>Low battery indication</li>
<li>LED indication of any operation</li>
<li>RS-232 interface</li>
<li>Data maintaining without batteries</li>
<li>Programming with software</li>
</ul>
<table id="table80" border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">Specifications </span>(accuracy stated at 23<span style="font-family: Verdana;">°C ±5°C ±(% of rdg + number of digits), &lt; 60% R.H.)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Measurement Range</td>
<td bgcolor="#C0C0C0">2 amps to 2500 amps</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Resolution</td>
<td bgcolor="#C0C0C0">1 amp</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Accuracy</td>
<td bgcolor="#C0C0C0"><span style="font-family: Verdana;">±(2.0% of reading + 2 digits)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Accuracy Error</td>
<td bgcolor="#C0C0C0">additional error due to not centering cable: 2% of reading</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Working Frequency</td>
<td bgcolor="#C0C0C0">50/60Hz <span style="font-family: Verdana;">±6%</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Type of Measurement</td>
<td bgcolor="#C0C0C0">True Rms</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Bandwidth</td>
<td bgcolor="#C0C0C0">3200Hz</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Crest Factor</td>
<td bgcolor="#C0C0C0">3</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td colspan="2" bgcolor="#FFFFFF"><span style="font-size: large;">General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Rate</td>
<td bgcolor="#C0C0C0">64 point, 20ms for each sampling period</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Sampling Period</td>
<td bgcolor="#C0C0C0">1 sec, 6 sec, 30 sec, 1 min, 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Memory Capacity</td>
<td bgcolor="#C0C0C0">1 Mbyte<br />
Life in days (depending on batteries life):<br />
5 days/1 sec; 34 days/6 sec; 170 days/30 sec; 364 days/1 min;<br />
1820 days/ 5 min</td>
</tr>
<tr>
<td valign="top" bgcolor="#C0C0C0" width="281">Computer Interface</td>
<td bgcolor="#C0C0C0">RS-232</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Operating Temperature/Humidity</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Storage Temperature</td>
<td bgcolor="#C0C0C0">-20<span style="font-family: Verdana;">°C to 60°C; 0 to 100% R.H. (RS-232 connector closed)</span></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Insulation</td>
<td bgcolor="#C0C0C0">class 2 (double insulation)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Protection Degree</td>
<td bgcolor="#C0C0C0">IP65 (RS-232 connector closed)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Altitude</td>
<td bgcolor="#C0C0C0">2000 meters</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td rowspan="2" valign="top" bgcolor="#C0C0C0" width="281">Reference Standards</td>
<td bgcolor="#C0C0C0">LVD: IEC/EN 61010-1 CAT III 1000V (to ground), CAT IV 600V (to ground)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0">EMC: IEC/EN 61326 (1997) +A1 (1998) +A2 (2001)</td>
</tr>
<tr>
<td bgcolor="#FFFFFF" width="281"></td>
<td bgcolor="#FFFFFF"></td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Power Supply</td>
<td bgcolor="#C0C0C0">2 x 1.5 volt type &#8216;AA&#8217; alkaline batteries type LR6, AM3, MN1500</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Battery Life</td>
<td bgcolor="#C0C0C0">6 months</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Dimensions</td>
<td bgcolor="#C0C0C0">129mm (L) x 80mm (W) x 43mm (D)</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Maximum Conductor Diameter</td>
<td bgcolor="#C0C0C0">174mm</td>
</tr>
<tr>
<td bgcolor="#C0C0C0" width="281">Weight</td>
<td bgcolor="#C0C0C0">500g (with internal batteries)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/">HT Italia XL422 3-Phase Current Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/ht-italia-xl422-3-phase-current-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed R5003 Single Phase Two Channel AC Voltage/Current Datalogger</title>
		<link>https://obiat.com.au/product/reed-r5003-single-phase-two-channel-ac-voltagecurrent-datalogger/</link>
					<comments>https://obiat.com.au/product/reed-r5003-single-phase-two-channel-ac-voltagecurrent-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 13 Apr 2016 07:24:11 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2725</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p><strong><span style="font-size: large;">Reed R5003 Features:</span></strong></p>
<ul>
<li>Simultaneously measure two channels, True-Rms AC voltage or Current, or one AC voltage and one AC current input.</li>
<li>User programmable sample rates from 1 second to 24 hours.</li>
<li>Stores up to 256,000 measurements.</li>
<li>User programmable high/low alarms.</li>
<li>Auto power off and battery check.</li>
<li>LCD indicates time/date, current readings, Min/Max, peak hold and whether alarm settings have been exceeded.</li>
<li>Download collected data through the USB interface to PC.</li>
<li>Includes AC current clamp sensor and voltage sensor, USB cable, software, and batteries</li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/04/r5003-manual.pdf" target="_blank" rel="">REED R5003 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="137" height="81" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-r5003-single-phase-two-channel-ac-voltagecurrent-datalogger/">Reed R5003 Single Phase Two Channel AC Voltage/Current Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="gkLegend4">
<h4>REED R5003 Features</h4>
<ul class="gkCircle2">
<li>AC Current Range: 10 to 200A Resolution: 0.1A</li>
<li>Accuracy: ±(2% rdg. ±1A)</li>
<li>AC Voltage Range: 10 to 600V</li>
<li>Resolution: 0.1V</li>
<li>Accuracy: ±(2% rdg. ±1V)</li>
<li>Power Supply: 4 AAA batteries and 1 C R 3V</li>
<li>memory button battery (CR2032)</li>
<li>Dimensions: 114 x 63 x 34mm (4.5 x 2.5 x 1.3&#8243;)</li>
<li>Weight: 248g (8.7 lb)</li>
</ul>
</div>
<div class="gkLegend4">
<h4>REED R5003 Specifications</h4>
<ul class="gkCircle2">
<li>Simultaneously measure 2 True RMS AC voltage inputs OR 2 AC current inputs OR 1 AC voltage and 1 AC current input</li>
<li>User programmable sample rates from 1 second to 24 hours</li>
<li>Stores up to 256,000 measurements</li>
<li>User programmable high/low alarms</li>
<li>LCD indicates time/date, current readings,</li>
<li>Max/Min, Peak hold and whether alarm settings have been exceeded</li>
<li>Download collected data through USB interface</li>
<li>Auto power off and battery check</li>
<li>Includes AC current clamp sensor and voltage sensor, USB cable, software, and battery</li>
</ul>
</div>
<h4 class="title">How to use Reed Voltage/Current True RMS datalogger (R5003)</h4>
<p><strong>Using the Max and Min function</strong><br />
While taking a measurement, by pressing the &#8220;MAX/MIN&#8221; button once you will activate the Max function. The meter will display the MAX (maximum) reading. Press the button again to display the MIN (minimum) reading. A third press will exit MAX/MIN mode. The Reed R5003 datalogger will automatically exit MAX/MIN mode in 10 seconds if no button is pressed.</p>
<p><strong>Auto Power Off</strong><br />
After 5 mins of inactivity, Reed R5003 will automatically shut off. With the &#8220;Recording&#8221; function active the Auto Power Off funtion is disable.</p>
<p><strong>How to record data using &#8220;Recording&#8221; function</strong><br />
Firstly you have to setup the record mode according with the datalogging software. Pressing the &#8220;START/STOP&#8221; button for more than 4 seconds will switch the instrument into the record mode and the values will be recorded. The REC icon will display in that confirm the meter recording measurements data. To stop recording press the same button again for more than 4 seconds. The data recording will stop when the memory is full.</p>
<p>The post <a href="https://obiat.com.au/product/reed-r5003-single-phase-two-channel-ac-voltagecurrent-datalogger/">Reed R5003 Single Phase Two Channel AC Voltage/Current Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r5003-single-phase-two-channel-ac-voltagecurrent-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Extech EA15 Thermocouple Datalogging Thermometer</title>
		<link>https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/</link>
					<comments>https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 22 Mar 2016 21:12:34 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1985</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1918" src="http://obiat.com.au/wp-content/uploads/2016/03/Extech-logo.jpg" alt="Extech logo" width="200" height="61" /></p>
<ul class="featurestext">
<li><strong>Dual input accepts Types J, K, E, T, R, S, and N thermocouples</strong></li>
<li><strong>Built-in datalogger stores up to 8800 data sets</strong></li>
<li><strong>RS-232 port to transfer data to PC for analysis</strong></li>
<li><strong>Real Time Clock</strong></li>
<li><strong>Includes Windows® 95/98/NT/2000/ME/XP compatible software and cable</strong></li>
<li>Compact and rugged design features large backlit display</li>
<li>Displays [T1 plus T2] or [T1-T2 plus T1] or [T1-T2 plus T2]</li>
<li>Selectable units of °F, °C, K (Kelvin)</li>
<li>Wide temperature range with 0.1°/1° resolution</li>
<li>Timer function displays elapsed time plus the time when MIN and MAX readings are taken</li>
<li>OFFSET key used for zero function to make relative measurements</li>
<li>Data Hold function freezes reading on display</li>
<li>Auto Power off to save battery life</li>
<li>Low battery and overrange indication</li>
<li>Records Max/Min readings for later recall</li>
<li>Complete with built-in stand, protective holster, two Type K bead wire temperature probes (-20 to 250°C), and 6 AAA batteries</li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/03/EA15_UM.pdf" target="_blank" rel="">Extech EA15 User Manual</a></p>
<h4>Authorised Australian Distributor</h4>
<p><img class="alignnone size-full wp-image-2451" src="http://obiat.com.au/wp-content/uploads/2016/04/Capture-2.jpg" alt="CE" width="37" height="30" />   <img class="alignnone size-full wp-image-2450" src="http://obiat.com.au/wp-content/uploads/2016/04/1-Year.jpg" alt="1 Year" width="67" height="35" /></p>
<p>The post <a href="https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/">Extech EA15 Thermocouple Datalogging Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Extech EA15 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">Measurement Ranges</td>
</tr>
<tr>
<td class="speccelltitle" width="250"> K &#8211; Type</td>
<td class="speccelldata">-150.0°C to +1370.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J &#8211; Type</td>
<td class="speccelldata">-150.0°C to +1090.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">T &#8211; Type</td>
<td class="speccelldata">-150.0°C to +400.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">E &#8211; Type</td>
<td class="speccelldata">-150.0°C to +870.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">R &#8211; Type</td>
<td class="speccelldata">0.0°C to +1767.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">S &#8211; Type</td>
<td class="speccelldata">0.0°C to +1767.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">N &#8211; Type</td>
<td class="speccelldata">-150.0°C to +1300.0°C</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Resolution</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J, K, T, E, N &#8211; Type</td>
<td class="speccelldata">0.1°F/°C/K</td>
</tr>
<tr>
<td class="speccelltitle" width="250">R, S &#8211; Type</td>
<td class="speccelldata">1.0°F/°C/K (0.1° for reference only)</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Accuracy</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J, K, T, E, N &#8211; Type</td>
<td class="speccelldata">±(0.05% reading + 1.5°F(0.75°C)) below -148°F (-100°C)</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J, K, E, N &#8211; Type</td>
<td class="speccelldata">add ±0.15%</td>
</tr>
<tr>
<td class="speccelltitle" width="250">T &#8211; Type</td>
<td class="speccelldata">add ±0.45%</td>
</tr>
<tr>
<td class="speccelltitle" width="250">R, S &#8211; Type</td>
<td class="speccelldata">add ±(0.05 of reading +2°F(1°C))</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Temperature Coefficient</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Outside the specified range<br />
+18°C to 28°C</td>
<td class="speccelldata">±(0.01% of reading +0.06°F per °F (+0.03 °C))</td>
</tr>
<tr>
<td class="speccelldata" colspan="2" align="center">Below -100°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J, K, E, N &#8211; Type</td>
<td class="speccelldata">0.04% of reading</td>
</tr>
<tr>
<td class="speccelltitle" width="250">T &#8211; Type</td>
<td class="speccelldata">0.08% of reading</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">General</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Display</td>
<td class="speccelldata">Dual Display Multi-function LCD with Backlight</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Input Protection</td>
<td class="speccelldata">60VDC, 24VAC rms</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Measurement Rate</td>
<td class="speccelldata">1 time per 1.5 second</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Over range indication</td>
<td class="speccelldata">&#8220;OL&#8221; appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Open input indication</td>
<td class="speccelldata">&#8220;OL&#8221; appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Low battery indication</td>
<td class="speccelldata">“BT” appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Manual Memory Capacity</td>
<td class="speccelldata">98 sets</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Datalogging Memory Capacity</td>
<td class="speccelldata">8800 sets</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Power supply</td>
<td class="speccelldata">6 ‘AAA’ Batteries</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Battery life</td>
<td class="speccelldata">Approximately 200 hours with alkaline batteries</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Operating Temperature</td>
<td class="speccelldata">0 to 50°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Operating Humidity</td>
<td class="speccelldata">&lt; 80% RH</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Storage Temperature</td>
<td class="speccelldata">-10 to 60°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Storage Humidity</td>
<td class="speccelldata">10 to 80% RH</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Dimensions</td>
<td class="speccelldata">150 x 72 x 35mm</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Weight Approx.</td>
<td class="speccelldata">235g with batteries</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/">Extech EA15 Thermocouple Datalogging Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>