<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Insulation Testers Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-tag/insulation-testers/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-tag/insulation-testers/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Wed, 11 Sep 2019 00:47:22 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Insulation Testers Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-tag/insulation-testers/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Martindale CMi210 AC/DC TRMS Insulation Clamp Meter</title>
		<link>https://obiat.com.au/product/martindale-cmi210-ac-dc-trms-insulation-clamp-meter/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Mon, 26 Aug 2019 09:14:41 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=40964</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2019/08/Martindale_Logo.png"><img class="alignnone size-full wp-image-40509" src="https://obiat.com.au/wp-content/uploads/2019/08/Martindale_Logo.png" alt="" width="200" height="63" /></a></p>
<h3>Insulation Testing Clamp Meter !</h3>
<p>The Martindale CMi210 is a unique insulation clamp meter for the installation, testing and maintenance of domestic and industrial installations.</p>
<p>This high specification clamp meter can perform insulation tests to 6G Ohms with 5 test voltages from 50V to 1000V.</p>
<p><a href="https://mymeter.com.au/product/martindale-cmi210-ac-dc-trms-insulation-clamp-meter/"><img class="aligncenter wp-image-4095 size-full" src="https://obiat.com.au/wp-content/uploads/2017/08/Obiat-Buy-Now.png" alt="" width="250" height="116" /></a></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/08/Martindale-Mi210-Datasheet.pdf" rel="noopener noreferrer">Martindale Mi210 Datasheet</a></span></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/08/Martindale-Mi210-User-Manual.pdf" rel="noopener noreferrer">Martindale Mi210 User Manual</a></span></span></h4>
<p>The post <a href="https://obiat.com.au/product/martindale-cmi210-ac-dc-trms-insulation-clamp-meter/">Martindale CMi210 AC/DC TRMS Insulation Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Martindale CMi210 AC/DC TRMS Insulation Clamp Meter provides True RMS measurement of AC current to 1500A and AC voltage to 750V and Insulation testing to 1000V.</p>
<p>It will also measure DC current to 2000A and DC voltage to 1000V.</p>
<p><strong>Martindale CMi210 Features:</strong></p>
<ul>
<li><strong>Insulation resistance test from 50V to 1000V up to 6GΩ</strong></li>
<li><strong>Insulation resistance test to 6GΩ</strong></li>
<li>True RMS AC current 1500A</li>
<li>DC current to 2000A</li>
<li>True RMS voltage to 750V</li>
<li>DC voltage to 1000V</li>
<li>Continuity with audible indication</li>
<li>Duty cycle, resistance, capacitance , frequency, temperature</li>
<li>Tests DC voltage to 1000V</li>
<li>Test AC voltage to 750V</li>
<li>Resistance testing with range up to 60MΩ</li>
<li>Capacitance measurements to 6mF</li>
<li>Frequency testing to 10MHz</li>
<li>Duty cycle calculations</li>
<li>Temperature measurements using type K thermocouple</li>
<li>Insulation testing with selectable testing voltage of 50V, 100V, 250V, 500V and 1000V</li>
</ul>
<p>The CMi210 has all the same test functions you would expect to find on a high specification multimeter with the added benefit of temperature measurement.</p>
<p><strong>Martindale CMi210 Specifications</strong></p>
<table>
<tbody>
<tr>
<td><strong>Current AC</strong></td>
<td>True RMS 0.1A to 1500A (2 ranges)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>2.5% rdg + 10 dgt (≤ 600A) 60Hz</td>
</tr>
<tr>
<td><strong>Current DC</strong></td>
<td>0.1A to 2000A (2 ranges)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>2.0% + 5 dgt (≤600A)</td>
</tr>
<tr>
<td><strong>Voltage AC</strong></td>
<td>True RMS 0.001V to 750V, autoranging</td>
</tr>
<tr>
<td>Accuracy</td>
<td>1.5% rdg + 8 dgt</td>
</tr>
<tr>
<td><strong>Voltage DC</strong></td>
<td>0.001V to 1000V autoranging (5 ranges)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>0.5% rdg + 2 dgt</td>
</tr>
<tr>
<td><strong>Insulation resistance</strong></td>
<td>300kΩ-6GΩ depending on voltage test</td>
</tr>
<tr>
<td>Accuracy</td>
<td>250-1000V 1.5% +5</td>
</tr>
<tr>
<td><strong>Capacitance</strong></td>
<td>0.001µF to 6.6mF (4 ranges)</td>
</tr>
<tr>
<td>Frequency</td>
<td>0.01Hz to 10MHz (7 ranges)</td>
</tr>
<tr>
<td><strong>Resistance ranges</strong></td>
<td>600Ω, 6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1Ω on 600Ω</td>
</tr>
<tr>
<td>Accuracy</td>
<td>1.0% rdg + 5 dgt on 600Ω to 600kΩ</td>
</tr>
<tr>
<td><strong>Temperature</strong></td>
<td>-50°C to 1300°C (-58°F to 2372°F) K-type probes</td>
</tr>
<tr>
<td><strong>Continuity</strong></td>
<td>buzz at &lt;40Ω</td>
</tr>
<tr>
<td><strong>Maximum conductor</strong></td>
<td>55mm diameter or 70mm x 18mm bus bar</td>
</tr>
<tr>
<td><strong>Features</strong></td>
<td>Diode test, duty cycle</td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td>326 x 108 x 53mm</td>
</tr>
<tr>
<td><strong>Weight</strong></td>
<td>720g approx. incl batteries</td>
</tr>
<tr>
<td><strong>Includes</strong></td>
<td>Batteries, case, TL45 test leads, type K thermocouple and manual</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/martindale-cmi210-ac-dc-trms-insulation-clamp-meter/">Martindale CMi210 AC/DC TRMS Insulation Clamp Meter</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Metrel MI 3325 Multifunction Tester</title>
		<link>https://obiat.com.au/product/metrel-mi-3325-multifunction-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 26 Jun 2019 03:18:34 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=36812</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-Logo.gif"><img class="alignnone size-full wp-image-36307" src="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-Logo.gif" alt="" width="290" height="75" /></a></p>
<p>The Metrel MI 3325 MultiServicerXD is a top-of-the-line multifunction tester covering diverse industrial applications, where ruggedness and reliability are a must.</p>
<p>The MI 3325 features support for colour touch screen technology, advanced memory organizer including large SD card storage media and state of the art AUTOSEQUENCE®s.</p>
<h4>APPLICATIONS</h4>
<p>• Factory machinery safety testing<br />
• Test to IEC 61439-1 Standard for switchboards.<br />
• Industrial safety testing<br />
• Periodic safety testing<br />
• Production line safety testing<br />
• Portable appliances safety testing<br />
• Arc welding equipment safety testing<br />
• Switchgear, control gear (cabinets), safety testing</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://www.metrel.si/assets/Metrel/PDF_dokumentacija/Brochure/Ang/Brochure_MI_3325_MultiServicerXD_2019_Ang_Technical_info.pdf" rel="noopener noreferrer">METREL MI 3325 Datasheet</a></span></h4>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/metrel-mi-3325-multifunction-tester/">Metrel MI 3325 Multifunction Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Metrel MI 3325 Multifunction Tester features a strong data management facility enabling the user to create custom auto-tests with predefined limits for pass/fail evaluation, import predefined structure including test sequences or complete projects created in MESM.</p>
<p>Able to test to IEC 61439-1 Standard that will be mandatory by 2021 for testing Switchboards.</p>
<p>The Metrel Electrical Safety Manager (MESM) PC software enables upload of automated test sequences, projects, downloading of test results, automatic data storage into a file and printing of professional test reports specially designed for specific applications. Due to selected test functions, durable construction and accompanying PC SW package MI 3325 MultiServicerXD is the perfect instrument for electrical safety testing in the most demanding industrial environments and automated production lines or specialized workshops.</p>
<h3>Metrel MI 3325 Measuring Functions</h3>
<ul>
<li>Continuity (2-wire &amp; 4-wire), 0.2 A, 4 A, 10 A, 25 A + voltage drop @ 10 A;</li>
<li>HV AC, HV AC programmable 100 V &#8211; 5000 V;</li>
<li>Insulation resistance (Riso, Riso-S) 50 V, 100 V, 250 V, 500 V, 1000 V (DC);</li>
<li>Sub-leakage current, (Isub, Isub-S) 110 V (AC), 230 V (AC);</li>
<li>Z loop – fault loop impedance and prospective fault current (Ipsc, Ulpe, Uc(P));</li>
<li>Zs rcd – fault loop impedance and prospective fault current in system with RCD (Ipsc, pe, Uc(P));</li>
<li>Z line – line impedance and prospective short-circuit current (Ipsc, Uln);</li>
<li>Functional test (power P/S/Q, voltage, current, cos fi, frequency, ThdU, ThdI, PF);</li>
<li>Touch leakage current;</li>
<li>RCD testing (RCD Uc, RCD t, RCD I);</li>
<li>Differential leakage current;</li>
<li>PE leakage current;</li>
<li>Polarity;</li>
<li>Clamp current;</li>
<li>Voltage, Frequency, phase rotation;</li>
<li>Varistor test;</li>
<li>Voltage drop;</li>
<li>Discharging time.</li>
</ul>
<h3>Metrel MI 3325 Key Features</h3>
<ul>
<li>Touch screen: high resolution colour touch screen, 4.3” TFT.</li>
<li>Double manipulation: keyboard and touch screen enable the user to control the instrument in any manner they like.</li>
<li>Pre-defined AUTOSEQUENCE®s: enable the user simple and quick execution of test sequence for the chosen device.</li>
<li>Support for RCD testing: A, AC, B, B+ and F RCDs.</li>
<li>Testing of welding equipment (only in combination with A 1422): MultiServicerXD support testing of welding equipment in accordance with IEC/EN 60974-4.</li>
<li>Functional inspections.</li>
<li>Visual inspections.</li>
<li>Custom inspections (visual and functional).</li>
<li>Built-in help screens for referencing on site.</li>
<li>Built-in fuse tables for automatic evaluation of the line / loop impedance result.</li>
<li>Monitoring of all 3 voltages in real-time.</li>
<li>Hi-pot: high voltage AC (5 kV @ 250 VA).</li>
<li>Continuity: 4 – wire continuity test with selectable test current (0.2 A, 4 A, 10 A, 25 A) enabling precise measurements.</li>
<li>Communication: RS-232, USB, Ethernet and Bluetooth communication ports enabling downloading, uploading and remote control over instrument.</li>
<li>Multi-system testing: the instrument can be used on TT, TN, IT and 115 V supply systems.</li>
<li>Automated RCD testing procedure (RCD AUTO).</li>
<li>Automated impedance testing procedure (Z AUTO).</li>
<li>Measurement filtering according to the selected area group.</li>
<li>Large memory: support for microSD memory cards, 8 GB card already integrated in the instrument, although that can be expanded to 32 GB.</li>
<li>PC SW Metrel ES Manager: enables creation of test structures, user-defined AUTOSEQUENCE®s, professional test reports and data transfer for archiving.</li>
</ul>
<h3>Software</h3>
<ul>
<li>PC SW Metrel ES Manager: enables creation of test structures, user-defined AUTOSEQUENCE®s, professional test reports and data transfer for archiving.</li>
</ul>
<h3>Metrel MI 3325 Standard Accessories</h3>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-11953 aligncenter" src="https://rapid-tech.com.au/wp-content/uploads/2019/06/Metrel-MI-3325-Accessories.jpg" alt="" width="400" height="300" /></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li><span style="font-size: 90%;">Instrument MI 3325 MultiServicerXD</span></li>
<li><span style="font-size: 90%;">HV test lead with test probe</span></li>
<li><span style="font-size: 90%;">HV test lead with crocodile</span></li>
<li><span style="font-size: 90%;">Mains cable</span></li>
<li><span style="font-size: 90%;">IEC test cable</span></li>
<li><span style="font-size: 90%;">Residual voltage test cable</span></li>
<li><span style="font-size: 90%;">Plug test cable</span></li>
<li><span style="font-size: 90%;">3-wire test lead, 3 m</span></li>
<li><span style="font-size: 90%;">Continuity test lead, 2.5 m, 2 pcs</span></li>
<li><span style="font-size: 90%;">Test lead, red, 1.5 m</span></li>
<li><span style="font-size: 90%;">Test probe, 4 pcs (black, red, green, blue)</span></li>
<li><span style="font-size: 90%;">Crocodile clip, green</span></li>
<li><span style="font-size: 90%;">Crocodile clip, blue</span></li>
<li><span style="font-size: 90%;">Crocodile clip, black, 3 pcs</span></li>
<li><span style="font-size: 90%;">Crocodile clip, red, 3 pcs</span></li>
<li><span style="font-size: 90%;">Calibration certificate</span></li>
<li><span style="font-size: 90%;">RS-232 cable</span></li>
<li><span style="font-size: 90%;">USB cable</span></li>
<li><span style="font-size: 90%;">Short instruction manual</span></li>
<li><span style="font-size: 90%;">CD with instruction manual (full version)</span></li>
<li><span style="font-size: 90%;">PC SW Metrel ES Manager BASIC *</span></li>
<li><span style="font-size: 90%;">Protective bag for accessories (mounted on the case)</span></li>
</ul>
</li>
</ul>
</li>
</ul>
<p style="padding-left: 80px;"><span style="font-size: 90%;"><em>* Metrel ES Manager can be downloaded free of charge from Metrel Web server.</em></span></p>
<p>The post <a href="https://obiat.com.au/product/metrel-mi-3325-multifunction-tester/">Metrel MI 3325 Multifunction Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Metrel MI 3205 5kV Insulation Resistance Tester</title>
		<link>https://obiat.com.au/product/metrel-mi-3205-5kv-insulation-resistance-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 21 Jun 2019 00:03:02 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=36341</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-Logo.gif"><img class="alignnone size-full wp-image-36307" src="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-Logo.gif" alt="" width="290" height="75" /></a></p>
<p>The Metrel MI 3205 5kV Insulation Resistance Tester is a portable battery (Li-ion) or mains powered test instrument with excellent IP protection (IP65 case closed and IP54 case open), intended for diagnosing of Insulation Resistance by using high test voltages of up to 5 kV. It is designed and produced with the extensive knowledge and experience acquired through many years of working in this field.</p>
<div id="c19361" class="csc-default">
<div class="csc-header csc-header-n1">
<h4 class="csc-firstHeader"><span style="color: #0000ff;"><strong>Metrel MI 3205 Measuring Functions:</strong></span></h4>
</div>
</div>
<div id="c19362" class="csc-default">
<ul>
<li>Insulation Measurement;</li>
<li>Diagnostic Test (PI, DAR, DD);</li>
<li>Step Voltage Test;</li>
<li>Withstanding Voltage Test (DC) up to 5 kV;</li>
<li>Voltage and frequency measurement up to 550 V TRMS.</li>
<li><strong><span style="color: #ed1c24;">Now with two year warranty !</span></strong></li>
</ul>
</div>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-MI3205-Datasheet.pdf" rel="noopener noreferrer">Metrel-MI3205-Datasheet</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-MI3205-User-Manual.pdf" rel="noopener noreferrer">Metrel-MI3205-User-Manual</a></span></h3>
<p>The post <a href="https://obiat.com.au/product/metrel-mi-3205-5kv-insulation-resistance-tester/">Metrel MI 3205 5kV Insulation Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Constructed in it&#8217;s own rugged carrying case and with the ability to be powered by both mains connection and rechargeable batteries, the Metrel MI 3205 5kV Insulation Resistance Tester gives technicians all the tools they need to check the operation of items such as power transformers, transducers, rotating machinery/cables, high voltage generators and surge arrestors/varistors.</p>
<p>The Metrel MI 3205 5kV Insulation Resistance Tester has the ability to measure many different parameters &#8211; it can test insulation, performs PI, DAR and DD diagnostic tests, step voltage tests, withstanding voltage test and voltage/frequency measurements. It can measure insulation resistance up to 15TΩ and has adjustable test voltage from 50V to 5kV in 50V and 100V steps.</p>
<p><strong>Metrel MI 3205 5kV Insulation Resistance Tester Features:</strong></p>
<ul>
<li>Insulation resistance up to 15 TΩ;</li>
<li>Adjustable test voltage (50 V&#8230;5 kV) 50 V and 100 V step;</li>
<li>Programmable timer;</li>
<li>Capacitance measurement;</li>
<li>Charging rate for capacitive load &lt; 1,5 s / µF at 5 kV;</li>
<li>Automatic discharge of test object after completion of measurement;</li>
<li>Guard terminal;</li>
<li>High voltage breakdown detection;</li>
<li>Custom defined tests;</li>
<li>Auto adjustment function;</li>
<li>Measurement results in numerical and graphical form;</li>
<li>PC software HVLink PRO for downloading and analyzing of the test results and test report printing;</li>
<li>Isolated RS232 and USB communication ports, Bluetooth interface;</li>
<li>High quality accessories including shielded test leads in standard set;</li>
<li>High EM interferences protection: Input AC current noise rejection (1 mA@300 V) and additional averaging of the result (5, 10, 30, 60);<br />
CAT IV / 600 V;</li>
<li>Increased working nominal altitude to 3000 metres;</li>
<li>High power Li-ion battery pack (14.8V, 4.4Ah);</li>
<li>Mains and rechargeable battery power supply.</li>
</ul>
<h4 style="padding-left: 30px;"><strong>Metrel MI3205 Applications:</strong></h4>
<p style="padding-left: 30px;">• Power transformers;<br />
• Measuring transducers in distribution networks;<br />
• Testing insulation resistance of rotating machinery and cables;<br />
• Production line periodic testing and maintenance;<br />
• Troubleshooting and analysis of all kinds of insulation problems;<br />
• High voltage generators;<br />
• Surge arrestors and varistors.</p>
<p style="padding-left: 30px;"><a href="https://rapid-tech.com.au/wp-content/uploads/2018/02/MI3205-Accessories.jpg"><img decoding="async" class="alignnone size-full wp-image-6265" src="https://rapid-tech.com.au/wp-content/uploads/2018/02/MI3205-Accessories.jpg" alt="" width="750" height="355" /></a></p>
<p>The post <a href="https://obiat.com.au/product/metrel-mi-3205-5kv-insulation-resistance-tester/">Metrel MI 3205 5kV Insulation Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>HT ITALIA NEPTUNE Multimeter/Insulation Tester</title>
		<link>https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 19 Jun 2019 04:41:26 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=36329</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg"><img class="alignnone size-full wp-image-3842" src="https://obiat.com.au/wp-content/uploads/2016/05/HT-Italia-Logo.jpg" alt="" width="166" height="91" /></a></p>
<h4>HT ITALIA NEPTUNE Features:</h4>
<ul>
<li><span style="font-size: 90%;">Autorange function &#38; automatic detection of AC, DC for all measurements.</span></li>
<li><span style="font-size: 90%;">Insulation test voltages of 50,100,250,500,1000VDC</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS voltage up to 1000V.</span></li>
<li><span style="font-size: 90%;">Low-impedance LoZ input to eliminate “stray voltages” from the measurement</span></li>
<li><span style="font-size: 90%;">DC, AC TRMS, AC+DC TRMS current by means of an optional external current clamp</span></li>
<li><span style="font-size: 90%;">Measurement of voltage or current frequency.</span></li>
<li><span style="font-size: 90%;">Resistance and continuity with buzzer.</span></li>
<li><span style="font-size: 90%;">MAX/MIN/PEAK/HOLD functions.</span></li>
<li><span style="font-size: 90%;"> CAT IV 600V, CAT III 1000V Safety Rating</span></li>
<li><span style="font-size: 90%;">ISO 9000 Calibration Certificate included</span></li>
<li><span style="font-size: 90%;">Similar to the Fluke 1587 &#38; Fluke 1577</span></li>
</ul>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>     <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-Datasheet.pdf" rel="noopener noreferrer">NEPTUNE Datasheet</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-Brochure.pdf" rel="noopener noreferrer">NEPTUNE Brochure</a></span></h3>
<h3><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/NEPTUNE-User-Manual.pdf" rel="noopener noreferrer">NEPTUNE User Manual</a></span></h3>
<p>The post <a href="https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/">HT ITALIA NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HT ITALIA NEPTUNE Multimeter/Insulation Tester is a mix of technology that includes an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), an Harmonics analyzer and a True  RMS multimeter.</p>
<h4>HT ITALIA NEPTUNE Key Features:</h4>
<ul>
<li>it can quickly measure insulation up to 1000V, just like top-of-the-range testers.</li>
<li>50,100,250,500,1000VDC Insulation test voltages.</li>
<li>it measures continuity of protective conductors with 200mA to solve the most common problems related to masses.</li>
<li>measure Inrush currents, Harmonics and THD%, just like top-of-the-range power quality analyzers.</li>
<li>with a wide range of external clamp transducers it can measure AC TRMS, DC, AC+DC current and Inrush current, starting from 1mA up to 3000A.</li>
<li>compare each measurement with the limits prescribed by the Guidelines and I provide a clear result OK or NOT OK</li>
<li>it&#8217;s a multimeter with functions only available if using top-of-the-range instruments.</li>
<li>CAT IV 600V, CAT III 1000V Safety Rating</li>
<li>Similar to the Fluke 1587 &amp; Fluke 1577</li>
<li>ISO 9000 CALIBRATION CERTIFICATE INCLUDED</li>
</ul>
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">
<h4><strong>HT ITALIA NEPTUNE Technical Specifications</strong></h4>
</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>DC voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS, LoZ voltage</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.5V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">32Hz ÷ 1kHz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS current with flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>AC TRMS, DC, AC+DC TRMS current with standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(0.5%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Flexible clamp F3000U</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1A ÷ 3000A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Inrush current (DIRC) &#8211; Standard clamp</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV ÷ 1000mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1mV</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Response time of peak</span></td>
<td class="speccelldata"><span style="font-size: 90%;">1ms</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Max RMS response time</span></td>
<td class="speccelldata"><span style="font-size: 90%;">16.6ms, 20ms, 50ms, 100ms, 150ms, 175ms, 200ms</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Resistance and Continuity test</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.0Ω ÷ 1999Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(1.0%reading + 5digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Buzzer test</span></td>
<td class="speccelldata"><span style="font-size: 90%;">R&lt;30Ω</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Voltage / Current harmonics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Harmonic order</span></td>
<td class="speccelldata"><span style="font-size: 90%;">DC, 1st ÷ 25th + THD%</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.1V / 0.1A</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(5.0%rdg + 10digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Phase sequence with 1 terminal</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">100V ÷ 999.9V</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Frequency range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">42.5Hz ÷ 69Hz</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Insulation resistance</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test voltages</span></td>
<td class="speccelldata"><span style="font-size: 90%;">50,100,250,500,1000VDC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 999MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Resolution</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.01MΩ ÷ 1MΩ</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Basic accuracy (@ 500V)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Timer for measurements</span></td>
<td class="speccelldata"><span style="font-size: 90%;">15s, 30s, 1min, 5min, 10min</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Continuity of protective conductors</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test current</span></td>
<td class="speccelldata"><span style="font-size: 90%;">&gt;200mA DC (@ R&lt;5Ω)</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measuring range</span></td>
<td class="speccelldata"><span style="font-size: 90%;">0.00Ω ÷ 199.9Ω</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Open-circuit voltage</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 &lt; Vo &lt; 12V DC</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Accuracy</span></td>
<td class="speccelldata"><span style="font-size: 90%;">±(2.0%reading + 2digits)</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>General characteristics</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Instrument safety</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN61010-1, IEC/EN61010-2-030, IEC/EN61010-2-033</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">EMC</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61326-1</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test MΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Test LoΩ</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CEI 64-8, IEC/EN61557-4</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Phase sequence</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IEC/EN 61557-7</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Insulation</span></td>
<td class="speccelldata"><span style="font-size: 90%;">double insulation</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Pollution level</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Measurement category</span></td>
<td class="speccelldata"><span style="font-size: 90%;">CAT IV 600V, CAT III 1000V to earth and between inputs</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Mechanical characteristics</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Size (L x W x H)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">175 x 85 x 55mm</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Weight (batteries included)</span></td>
<td class="speccelldata"><span style="font-size: 90%;">420g</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Mechanical protection</span></td>
<td class="speccelldata"><span style="font-size: 90%;">IP40</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;"><strong>Power supply</strong></span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Battery type</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4&#215;1.5V batteries type AAA IEC LR03</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Auto power off</span></td>
<td class="speccelldata"><span style="font-size: 90%;">after 15 minutes’ idling</span></td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><span style="font-size: 90%;">Display</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Type of display</span></td>
<td class="speccelldata"><span style="font-size: 90%;">4 dgt LCD, max 9999 dots, decimal sign, point, backlight and bargraph, indication of polarity</span></td>
</tr>
<tr>
<td class="speccelltitle" width="125"><span style="font-size: 90%;">Updating frequency</span></td>
<td class="speccelldata"><span style="font-size: 90%;">2 times/s</span></td>
</tr>
</tbody>
</table>
<h3>HT ITALIA NEPTUNE  Included Accessories:</h3>
<p>• 4324-2 Pair of Red/Black banana connectors with 2/4mm tip<br />
• YAAMK0001HT0 Pair of Red/Black alligator clips<br />
• YABAT0001HT0 Alkaline battery type AAA IEC LR03 1.5V, 4 pieces<br />
• YABRS0002HT0 Carrying bag<br />
• YAMUM0068HT0 User manual on CD-ROM<br />
• YAMUM0067HT0 Quick user guide<br />
• Calibration certificate ISO9000</p>
<h3>Optional Accessories:</h3>
<p>• F3000U Flexible clamp with full scale 30/300/3000A AC and banana connectors<br />
• HT96U* Standard clamp with full scale 1/100/1000A AC and Hypertac connector<br />
• HT97U* Standard clamp with full scale 10/100/1000A AC and Hypertac connector<br />
• HT98U* Standard clamp with full scale 1000A DC and Hypertac connector<br />
• HT4006 Standard clamp with full scale 40/400A AC/DC and banana connectors<br />
• NOCANBA Adapter for clamp connection with Hypertac connector<br />
• 5004-IECR Red alligator clip<br />
• 5004-IECN Black alligator clip<br />
• C2065 3-wire cable Red, Black and Green with Schuko plug</p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-neptune-multimeter-insulation-tester/">HT ITALIA NEPTUNE Multimeter/Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Metrel MI 3210 10kv Insulation Resistance Tester</title>
		<link>https://obiat.com.au/product/metrel-mi-3210-10kv-insulation-resistance-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 18 Jun 2019 06:44:16 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=36320</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-Logo.gif"><img class="alignnone size-full wp-image-36307" src="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-Logo.gif" alt="" width="290" height="75" /></a></p>
<p>The Metrel MI 3210 TeraOhm XA 10kV is a portable, battery or mains powered test instrument with excellent IP protection (IP65), intended for diagnosing of Insulation Resistance by using high DC test voltages of up to 10kV. Because of its robustness (CAT IV protection) and high immunity to radiated RF fields it is best suited for industrial environment.</p>
<div id="c18172" class="csc-default">
<div class="csc-header csc-header-n1">
<h3 class="csc-firstHeader">METREL MI 3210 MEASURING FUNCTIONS</h3>
</div>
</div>
<div id="c18173" class="csc-default">
<ul>
<li>Insulation Measurement</li>
<li>Diagnostic Test (PI, DAR, DD)</li>
<li>Step Voltage Test</li>
<li>Withstanding Voltage Test (DC) up to 10kV</li>
<li>Voltage and frequency measurement up to 550V TRMS</li>
<li>
<h4><span style="color: #ff0000;">Now with two year warranty !</span></h4>
</li>
</ul>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a><span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/Metrel_MI_3210_Datasheet.pdf" rel="noopener noreferrer">Metrel_MI_3210_Datasheet</a></span><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"></a></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/06/Metrel-MI3210-User-Manual.pdf" rel="noopener noreferrer">Metrel-MI3210-User-Manual</a><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"></a></h4>
</div>
<p>The post <a href="https://obiat.com.au/product/metrel-mi-3210-10kv-insulation-resistance-tester/">Metrel MI 3210 10kv Insulation Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="csc-header csc-header-n3">
<h2>Metrel MI 3210 10kv Insulation Resistance Tester Features:</h2>
</div>
<ul>
<li>Insulation resistance up to 20 TΩ;</li>
<li>Adjustable test voltage (50V&#8230;10kV) 50V and 100V step;</li>
<li>Programmable timer;</li>
<li>Capacitance measurement;</li>
<li>Charging rate for capacitive load &lt; 3 s / µF at 10kV;</li>
<li>Automatic discharge of test object after completion of measurement;</li>
<li>Guard terminal</li>
<li>High voltage breakdown detection;</li>
<li>Custom defined tests</li>
<li>Auto adjustment function</li>
<li>Measurement  results in numerical and graphical form;</li>
<li>PC software HVLink PRO for downloading and analyzing of the test results and test report printing;</li>
<li>Isolated RS232 and USB communication ports, BT interface;</li>
<li>High quality accessories including shielded test leads in standard set;</li>
<li>High EM interferences protection: Input AC current noise rejection (1 mA∞600V) and additional averaging of the result (5, 10, 30, 60);</li>
<li>CAT IV / 600V;</li>
<li>Mains and rechargeable battery power supply.</li>
</ul>
<h4>Metrel MI 3210 Applications:</h4>
<ul>
<li>Testing of LV/MV/HV cables and equipment</li>
<li>Testing LV/MV/HV transformers</li>
<li>Tetsing LV/MV/HV motors and generators</li>
<li>Surge arrestors</li>
<li>Troubleshooting and analysis of all kinds of insulation problems</li>
</ul>
<h3 class="clear">Standard Accessories:<a href="http://www.metrel.si/index.php?eID=tx_cms_showpic&amp;file=uploads%2Fpics%2FMI_3210_TeraOhmXA_10_kV_standard-set_01.jpg&amp;md5=11d23cff8f1500b84dfb5de482ad882e8d8a219c&amp;parameters[0]=YTozOntzOjU6IndpZHRoIjtzOjM6IjQwMCI7czo3OiJib2R5VGFnIjtzOjIwOiI8&amp;parameters[1]=Qk9EWSBiZ0NvbG9yPWJsYWNrPiI7czo0OiJ3cmFwIjtzOjM3OiI8QSBocmVmPSJq&amp;parameters[2]=YXZhc2NyaXB0OmNsb3NlKCk7Ij4gfCA8L0E%2BIjt9"><img decoding="async" src="http://www.metrel.si/typo3temp/pics/1cfc1a0a37.jpg" alt="" width="200" height="150" /></a><img decoding="async" src="http://www.metrel.si/products/high-voltage-insulation-continuity-earth/hv-insulation-testers/clear.gif" width="100" height="1" /></h3>
<div class="order_description">
<ul>
<li>Instrument MI 3210 TeraOhmXA 10kV</li>
<li>10 kV shielded test lead with probe, 2 m</li>
<li>10 kV shielded test lead, 2 m, 2 pcs (black, red)</li>
<li>10 kV crocodile clip, 2 pcs (black, red)</li>
<li>Guard test lead, green, 2 m</li>
<li>Crocodile clip, green</li>
<li>Mains cable</li>
<li>PC SW HVLink PRO with USB and RS 232 cable</li>
<li>Handbook “Guide to modern insulation testing” on CD</li>
<li>Instruction manual on CD</li>
</ul>
<h4>Metrel MI 3210 Specifications:</h4>
<table width="504">
<tbody>
<tr>
<td width="302">Minimum Test Voltage</td>
<td width="202">50V</td>
</tr>
<tr>
<td width="302">Maximum Test Voltage</td>
<td width="202">10kV</td>
</tr>
<tr>
<td width="302">Maximum Insulation Resistance Measurement</td>
<td width="202">20TΩ</td>
</tr>
<tr>
<td width="302">Display Type</td>
<td width="202">LCD</td>
</tr>
<tr>
<td width="302">Test Current</td>
<td width="202">5mA</td>
</tr>
<tr>
<td width="302">Battery Life</td>
<td width="202">4 h @ 10 kV</td>
</tr>
<tr>
<td width="302">Minimum Operating Temperature</td>
<td width="202">-10°C</td>
</tr>
<tr>
<td width="302">Maximum Operating Temperature</td>
<td width="202">+50°C</td>
</tr>
<tr>
<td width="302">Power Source</td>
<td width="202">Battery, Mains</td>
</tr>
<tr>
<td width="302">Safety Category Level</td>
<td width="202">CAT IV</td>
</tr>
<tr>
<td width="302">Safety Category Voltage</td>
<td width="202">600V</td>
</tr>
<tr>
<td width="302">Safety Category</td>
<td width="202">CAT IV 600 V</td>
</tr>
<tr>
<td width="302">Height</td>
<td width="202">160mm</td>
</tr>
<tr>
<td width="302">Width</td>
<td width="202">330mm</td>
</tr>
<tr>
<td width="302">Model Number p</td>
<td width="202">MI 3210</td>
</tr>
<tr>
<td width="302">Length</td>
<td width="202">360mm</td>
</tr>
<tr>
<td width="302">Battery Type</td>
<td width="202">LC-R123R4PG, Lead Acid</td>
</tr>
<tr>
<td width="302">Weight</td>
<td width="202">6.5kg</td>
</tr>
<tr>
<td width="302">Dimensions</td>
<td width="202">360 x 330 x 160mm</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/metrel-mi-3210-10kv-insulation-resistance-tester/">Metrel MI 3210 10kv Insulation Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>KYORITSU 3023A Digital Insulation &#038; Continuity Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-3023a-digital-insulation-continuity-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 19 Feb 2019 06:32:07 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=28103</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu 3023A is the ideal insulation tester for any electrician. It's Digital Display allows better accuracy, easier reading of results and faster testing. It is the perfect instrument if you are upgrading from an analogue insulation tester.</p>
<h4>Main Features:</h4>
<p>• 100/250/500/1000V Test Voltages<br />
• Fast response and quick insulation test. (1 second result display)<br />
• Three functions in one unit, insulation test with 4 voltage ranges, continuity test, AC voltage measurement<br />
• 200mA measuring current on continuity testing</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 105%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/02/Kyoritsu-3023A-Datasheet.pdf" rel="noopener">Kyoritsu 3023A Datasheet</a></span></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><span style="font-size: 105%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2019/02/Kyoritsu-3023A-User-Manual.pdf" rel="noopener">Kyoritsu 3023A User Manual</a></span></span></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-3023a-digital-insulation-continuity-tester/">KYORITSU 3023A Digital Insulation &#038; Continuity Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<section class="mb10">
<h4>KYORITSU 3023A Digital Insulation &amp; Continuity Tester</h4>
<p>KYORITSU 3023A is a 4-range digital insulation resistance tester with 100/250/500/1000V Test Voltages. The 100V range is suitable for the testing of telecommunication cables. Resistance measurement with audible Continuity check function are also available.</p>
<h4>KYORITSU 3023A Features:</h4>
<p>• Fast response and quick insulation test.<br />
• Fast Result Display in one second<br />
• 100/250/500/1000V Test Voltages<br />
• Three functions in one unit, insulation test with 4 voltage ranges, continuity test, AC voltage measurement<br />
• 200mA measuring current on continuity testing<br />
• Comparator function with PASS / FAIL and buzzer<br />
• 0Ω adjustment at continuity measuring range<br />
• Memory function up to 99 data<br />
• Backlight LCD provides easy reading in dark locations<br />
• Safety lock system prevents an erroneous operation on 500 and 1000 Volt ranges<br />
• Safety standard IEC 61010-01 CAT III 600V</p>
<h4>KYORITSU 3023A Specifications:</h4>
<h4 class="headLine4 mb10">Insulation resistance</h4>
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Test voltage</th>
<td>100/250/500/1000V</td>
</tr>
<tr>
<th>Measuring range<br />
(Auto range)</th>
<td>4.000/40.00/200.0MΩ (100V)<br />
4.000/40.00/400.0/2000MΩ (250/500/1000V)</td>
</tr>
<tr>
<th>Mid-scale value</th>
<td>5MΩ (100/250V)<br />
50MΩ (500/1000V)</td>
</tr>
<tr>
<th>First effective measuring range</th>
<td>0.2 &#8211; 20MΩ (100V)<br />
0.2 &#8211; 40MΩ (250V)<br />
0.2 &#8211; 200MΩ (500V)<br />
0.2 &#8211; 1000MΩ (1000V)</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±2%rdg±6dgt</td>
</tr>
<tr>
<th>Second effective measuring range lower</th>
<td>0.110 &#8211; 0.199MΩ</td>
</tr>
<tr>
<th>Second effective measuring range upper</th>
<td>20.01 &#8211; 200.0MΩ (100V)<br />
40.01 &#8211; 2000MΩ (250V)<br />
200.1 &#8211; 2000MΩ (500V)<br />
1001 &#8211; 2000MΩ (1000V)</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±5%rdg±6dgt</td>
</tr>
<tr>
<th>Rated current</th>
<td>DC 1 &#8211; 1.2mA</td>
</tr>
<tr>
<th>Output short circuit current</th>
<td>1.5mA max</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="mb10">
<h4 class="headLine4 mb10">Ω/Continuity</h4>
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Auto range</th>
<td>40.00/400.0Ω</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±2%rdg±8dgt</td>
</tr>
<tr>
<th>Output voltage on open circuit</th>
<td>5V±20%</td>
</tr>
<tr>
<th>Output short circuit current</th>
<td>DC 220±20mA</td>
</tr>
<tr>
<th>Fuse</th>
<td>Quick acting ceramic fuse 0.5A/600V (Ø6.35×32mm)</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="mb10">
<h4 class="headLine4 mb10">AC Voltage</h4>
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>AC voltage range</th>
<td>AC 20 &#8211; 600V (50/60Hz)<br />
DC -20 &#8211; -600V/+20 &#8211; +600V</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±3%rdg±6dgt</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="mb10">
<h4 class="headLine4 mb10">General</h4>
<div class="tableScroller">
<table class="specTable mb0">
<tbody>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT III 600V, IEC 61557-1,2,4, IEC 61326-1 (EMC), IEC 60529 (IP40)</td>
</tr>
<tr>
<th>Power source</th>
<td>R6 × 6 or LR6 × 6</td>
</tr>
<tr>
<th>Dimensions / Weight</th>
<td>105(L) × 158(W) × 70(D)mm / 600g approx.</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7150A (Remote control switch set),<br />
9121 (Shoulder strap), R6 (AA) × 6, Instruction Manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7115 (Extension Probe), 8016 (Hook type prod),<br />
8923 (Fuse [0.5A/600V]), 9089 (Carrying Case)</td>
</tr>
</tbody>
</table>
</div>
</section>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-3023a-digital-insulation-continuity-tester/">KYORITSU 3023A Digital Insulation &#038; Continuity Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Kyoritsu 3128 12kV High Voltage Insulation Tester</title>
		<link>https://obiat.com.au/product/kyoritsu-3128-12kv-high-voltage-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Wed, 12 Sep 2018 06:44:35 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=16860</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg"><img class="alignnone size-full wp-image-16861" src="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-Authorised.jpg" alt="" width="250" height="69" /></a></p>
<p>The Kyoritsu <span class="highlight">3128</span> is a digital CAT IV High Voltage Insulation Tester with capabilities of testing insulation resistance up to 35TΩ at test voltages up to 12kV. The Kyoritsu <span class="highlight">3128</span> model is designed for field use with an IP64 rating and features a large backlit LCD display.</p>
<p>• Microprocessor controlled high voltage insulation resistance tester with Diagnostic functions.<br />
• Suitable for analyzing the insulation characteristics of cables, transformers, motors, generators, high-pressure switches, insulators, wiring installations, etc.<br />
• 6 ranges: 500V, 1000V, 2500V, 5000V, 10000V, 12000V<br />
Fine adjustment of voltage setting at each range is also possible<br />
• Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight.<br />
• Can be operated from built-in rechargeable battery or from AC line.<br />
• Automatic discharge after test with monitoring of the discharge voltage.<br />
• Internal memory can store about 43,000 data (max).<br />
• Robust design for field use with IP64 rating (with lid closed)</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/09/Kyoritsu-3128-Datasheet.pdf" rel="noopener"><span style="text-decoration: underline;"><span style="font-size: 105%;">Kyoritsu-3128-Datasheet</span></span></a></h4>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-3128-12kv-high-voltage-insulation-tester/">Kyoritsu 3128 12kV High Voltage Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Kyoritsu 3128 12kV High Voltage Insulation Tester is a microprocessor controlled tester and includes various diagnostic functions that provide the ability to test the polarization index (PI), the dielectric absorption ratio (DAR) and the dielectric discharge (DD). Step voltage (SV) measurements can be made where successive voltage increments are implemented to test the degradation of insulation.7</p>
<p>Using the Kyoritsu 3128 High Voltage Insulation Tester insulation resistances can be measured up to 35TΩ, with test voltages up to 12kV</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-3128-Display.jpg"><img decoding="async" class="alignnone size-full wp-image-5854" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-3128-Display.jpg" alt="" width="824" height="471" /></a></p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-Measurement.jpg"><img decoding="async" class="alignnone size-full wp-image-5855" src="https://rapid-tech.com.au/wp-content/uploads/2017/11/Kyoritsu-Measurement.jpg" alt="" width="828" height="785" /></a></p>
<h3>Kyoritsu 3128 12kV High Voltage Insulation Tester Specifications:</h3>
<div class="editor">
<p class="tm3"><em>Insulation resistance (*): Accuracy is not guaranteed with setting of 250V or less</em></p>
<table>
<tbody>
<tr>
<th>Rated voltage</th>
<td>500V</td>
<td>1000V</td>
<td>2500V</td>
<td>5000V</td>
<td>10000V</td>
<td>12000V</td>
</tr>
<tr>
<th>Max measurement value</th>
<td>500GΩ</td>
<td>1TΩ</td>
<td>2.5TΩ</td>
<td>5TΩ</td>
<td colspan="2">35TΩ</td>
</tr>
<tr>
<th rowspan="3">Accuracy</th>
<td>400k～50GΩ ±5%rdg±3dgt<br />
(*)</td>
<td>800k～100GΩ 5%rdg±3dgt</td>
<td>2M～250GΩ ±5%rdg±3dgt</td>
<td>4M～500GΩ ±5%rdg±3dgt</td>
<td colspan="2">8M～1TΩ ±5%rdg±3dgt</td>
</tr>
<tr>
<td rowspan="2">50G～500GΩ<br />
±20%rdg<br />
(*)</td>
<td rowspan="2">100G～1TΩ<br />
±20%rdg</td>
<td rowspan="2">250G～2.5TΩ<br />
±20%rdg</td>
<td rowspan="2">500G～5TΩ<br />
±20%rdg</td>
<td colspan="2">1T～10TΩ<br />
±20%rdg</td>
</tr>
<tr>
<td colspan="2">10T &#8211; 35TΩ<br />
Values are displayed, but accuracy isn&#8217;t guaranteed</td>
</tr>
<tr>
<th>Short circuit current</th>
<td colspan="6">Max 5.0mA</td>
</tr>
<tr>
<th>Load resistor to output rated voltage</th>
<td>0.5MΩ or more</td>
<td>1MΩ or more</td>
<td>2.5MΩ or more</td>
<td>5MΩ or more</td>
<td>20MΩ or more</td>
<td>24MΩ or more</td>
</tr>
</tbody>
</table>
<h4 class="tm3">Output voltage</h4>
<table>
<tbody>
<tr>
<th>Rated voltage</th>
<td>500V</td>
<td>1000V</td>
<td>2500V</td>
<td>5000V</td>
<td>10000V</td>
<td>12000V</td>
</tr>
<tr>
<th>Monitor accuracy</th>
<td>±10%±20V</td>
<td>±10%±20V</td>
<td>±10%±20V</td>
<td>±10%±20V</td>
<td>±10%±20V</td>
<td>±10%±20V</td>
</tr>
<tr>
<th>Output accuracy</th>
<td>0 &#8211; +20%</td>
<td>0 &#8211; +10%</td>
<td>0 &#8211; +10%</td>
<td>0 &#8211; +10%</td>
<td>-5 &#8211; +5%</td>
<td>-5 &#8211; +5%</td>
</tr>
<tr>
<th>Selectable range</th>
<td>50 &#8211; 600V<br />
(in steps of 5V)</td>
<td>610 &#8211; 1200V (in steps of 10V)</td>
<td>1225 &#8211; 3000V <span class="s1">(in steps of 25V)</span></td>
<td>3050 &#8211; 6000V <span class="s1">(in steps of 50V)</span></td>
<td>6100 &#8211;<br />
10000V <span class="s1">(in steps of 100V)</span></td>
<td>10100 &#8211; 12000V <span class="s1">(in steps of 100V)</span></td>
</tr>
</tbody>
</table>
<h4 class="tm3"><b>Voltage measurement</b></h4>
<table>
<tbody>
<tr>
<th>Measuring range</th>
<td>DCV：±30 ～ ±600V、ACV：30 ～ 600V （50/60Hz）</td>
</tr>
<tr>
<th>Accuracy</th>
<td>±2%rdg±3dgt</td>
</tr>
</tbody>
</table>
<h4 class="tm3">Current measurement</h4>
<table>
<tbody>
<tr>
<th>Measuring range</th>
<td>5.00nA &#8211; 2.40mA (Depending on the insulation resistance)</td>
</tr>
</tbody>
</table>
<h4 class="tm3">Capacitance measurement</h4>
<table>
<tbody>
<tr>
<th>Measuring range</th>
<td>5.0nF ～ 50.0μF<br />
(500V/1000V/2500V/5000V)</td>
<td>5.0nF &#8211; 1.0µF (display range: 5.0nF &#8211; 50.0µF) (10000V/12000V)</td>
</tr>
<tr>
<th>Accuracy</th>
<td colspan="2">±5%rdg±5dgt</td>
</tr>
</tbody>
</table>
</div>
<section class="mb10">
<h4 class="headLine4 mb10">General</h4>
<table class="specTable mb0">
<tbody>
<tr>
<th>Applicable standards</th>
<td>IEC 61010-1 CAT IV 600V Pollution degree 2,<br />
IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed.</td>
</tr>
<tr>
<th>Operating temperature &amp; humidity range</th>
<td>-10ºC &#8211; Relative humidity 85% or less<br />
50ºC /(when operating with an external power supply, no condensation)<br />
0ºC &#8211; 40ºC /Relative humidity 85% or less<br />
(when operating with battery, no condensation)</td>
</tr>
<tr>
<th>Storage temperature &amp; humidity range</th>
<td>-20ºC &#8211; 60ºC / Relative humidity 75% or less (no condensation)</td>
</tr>
<tr>
<th>Power source</th>
<td>Rechargeable Lead storage battery (12V)*<br />
Charging time: approx. 8 hours / AC Power supply (100V &#8211; 240V, 50/60Hz)<br />
* Continuous measuring time:<br />
approx. 4 hours<br />
(a load of 100MΩ at the Insulation resistance 12000V Range.)<br />
approx. 2 hours<br />
(Max current consumption in range while rated currents are maintained.)</td>
</tr>
<tr>
<th>Dimensions</th>
<td>330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case</td>
</tr>
<tr>
<th>Weight</th>
<td>9kg approx. (including battery) *Instrument and Hard case</td>
</tr>
<tr>
<th>Included Accessories</th>
<td>7170 (Main cord), 7224A (Earth cord), 7225A (Guard cord), 7226A (Line probe),<br />
7227A (Line probe with alligator clip), 8029 (Extension prod),<br />
8212-USB-W (USB adaptor with KEW Windows (Software)),<br />
Instruction manual</td>
</tr>
<tr>
<th>Optional Accessories</th>
<td>7254 (Longer Line probe with alligator clip)</td>
</tr>
</tbody>
</table>
</section>
<p>The post <a href="https://obiat.com.au/product/kyoritsu-3128-12kv-high-voltage-insulation-tester/">Kyoritsu 3128 12kV High Voltage Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER</title>
		<link>https://obiat.com.au/product/sew-6305in-5kv-high-voltage-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 20 May 2018 08:08:59 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8836</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<h4><span style="color: #ff0000; font-size: 110%;"><strong>SEW 6305IN Features</strong></span></h4>
<p>● High contrast OLED display<br />
● Microprocessor-controlled<br />
● Tests insulation resistance up to 10 TΩ<br />
● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V<br />
● AC / DC Voltmeter<br />
● Short-circuit current up to 5mA<br />
● PI (Polarization Index) indication<br />
● DAR (Dielectric Absorption Ratio) indication<br />
● Auto-ranging on all insulation ranges<br />
● Optical USB to RS-232 data transmission<br />
● Well isolated from contact<br />
● Well protected from surges<br />
● 2 built-in optical LEDs for data transfer<br />
● Visual &#38; audio warning of external voltage presence (≥30Vac or ≥30Vdc)<br />
● Auto-hold function to freeze reading<br />
● Overload protection<br />
● Adjustable testing duration: 1~30 minutes<br />
● Internal memory for data storage<br />
● Displays testing duration for insulation measurement<br />
● Auto-off function<br />
● 200 measurement results can be saved in memory and recalled</p>
<p><span style="color: #0000ff;"><strong>Authorised Australian Distributor</strong></span></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-6305IN-Datasheet.pdf" rel="noopener">SEW-6305IN-Datasheet</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/sew-6305in-5kv-high-voltage-insulation-tester/">SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="color: #0000ff; font-size: 110%;">SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER SPECIAL FUNCTIONS</span></h4>
<p><strong><span style="color: #0000ff;">Voltmeter</span><br />
</strong>Conventional insulation testers are highly susceptible to damage when testing insulation resistance while voltage is present on the measured object (whether ACV or DCV). To safely prevent damage, the SEW 6305IN has the unique ability to sense voltage on a measured object. If any voltage is sensed, the tester will automatically switch to voltage detection mode and display the voltage finding on the LCD screen. This allows the user to prevent damage caused by attempting to measure insulation resistance while voltage is present.</p>
<p><strong><span style="color: #0000ff;">DAR = Dielectric Absorption Ratio</span><br />
</strong>The Dielectric Absorption Ratio is the ratio of the insulation resistance measured at 1 minute divided by the insulation resistance measured at 30 seconds. Thirty seconds after starting a test, SEW 6305IN will beep, indicating that the resistance value measured at 30 seconds has been saved. One minute after starting a test, the tester will beep again, indicating that the DAR result has been computed. The display format then changes to display the DAR result.</p>
<p><img decoding="async" class="alignnone wp-image-4647" src="http://rapid-tech.com.au/wp-content/uploads/2017/01/SEW-6305IN-B.jpg" alt="SEW 6305IN B" width="321" height="75" /></p>
<p><strong><span style="color: #0000ff;">PI = Polarization Index</span><br />
</strong>The Polarization Index is the ratio of the insulation resistance measured at 10 minutes divided by the insulation resistance measured at 1 minute. One minute after starting a test, the resistance value is saved and the DAR is displayed. The test then continues, and after 10 minutes, the SEW 6305IN will beep again, indicating that the PI result has been computed. The display format changes to display the PI result.</p>
<p><img decoding="async" class="alignnone wp-image-4648" src="http://rapid-tech.com.au/wp-content/uploads/2017/01/SEW-6305IN-C.jpg" alt="SEW 6305IN C" width="303" height="57" /></p>
<p>Note: Tests on lower insulation resistance take longer, which tends to deteriorate the test specimen. Thus, higher DAR or PI readings (closer to 1) would indicate a better grade of insulation.</p>
<h4><span style="color: #0000ff; font-size: 110%;">SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER SPECIFICATIONS:</span></h4>
<table border="0" width="606" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="xl66" width="196" height="53"><strong><span style="font-family: Arial;">Test Voltage</span></strong></td>
<td class="xl76" colspan="2" width="410"><span style="font-family: Arial;">500V, 1000V, 2500V, 5000V</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="107"><strong><span style="font-family: Arial;">Insulation resistance</span></strong></td>
<td class="xl78" colspan="2" width="410"><span style="font-family: Arial;">1TΩ / 500V<br />
2TΩ / 1000V<br />
5TΩ / 2500V<br />
10TΩ / 5000V</span></td>
</tr>
<tr>
<td class="xl83" rowspan="2" width="196" height="160"><strong><span style="font-family: Arial;">Accuracy</span></strong></td>
<td class="xl71" width="205"><span style="font-family: Arial;">0~100GΩ / 500V<br />
0~200GΩ / 1000V<br />
0~500GΩ / 2500V<br />
0~1000GΩ / 5000V</span></td>
<td class="xl69" width="205"><span style="font-family: Arial;">±(5%rdg+5dgt) </span></td>
</tr>
<tr>
<td class="xl71" width="205" height="80"><span style="font-family: Arial;">100G~1TΩ / 500V<br />
200G~2TΩ / 1000V<br />
500G~5TΩ / 2500V<br />
1000G~10TΩ / 5000V</span></td>
<td class="xl69" width="205"><span style="font-family: Arial;">±12%rdg</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="106"><strong><span style="font-family: Arial;">Resolution</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">1000MΩ: 1MΩ<br />
10GΩ: 0.01GΩ<br />
100GΩ: 0.1GΩ<br />
1TΩ: 1GΩ<br />
10TΩ: 10GΩ</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="40"><strong><span style="font-family: Arial;">Short circuit current</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">up to 5mA</span></td>
</tr>
<tr>
<td class="xl67" height="33"><strong><span style="font-family: Arial;">PI (Polarization Index)</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">V</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="53"><strong><span style="font-family: Arial;">DAR (Dielectric Absorption Ratio)</span></strong></td>
<td class="xl79" colspan="2"><span style="font-family: Arial;">V</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="107"><strong><span style="font-family: Arial;">Voltmeter</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">ACV: 30~600V (50/60Hz)<br />
DCV: 30~600V<br />
Accuracy: ±(2.0%rdg + 3dgt)<br />
Resolution: 1V</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="42"><strong><span style="font-family: Arial;">Current<br />
measurement</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">0.5nA ~ 0.55mA<br />
(Depending on the insulation resistance)</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="53"><strong><span style="font-family: Arial;">Power source</span></strong></td>
<td class="xl79" colspan="2"><span style="font-family: Arial;">Rechargeable battery</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="53"><strong><span style="font-family: Arial;">AC Adapter</span></strong></td>
<td class="xl78" colspan="2" width="410"><span style="font-family: Arial;">Input: 100-240Vac, 0.4A, 50-60Hz<br />
Output: 24Vdc, 0.62A</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="53"><strong><span style="font-family: Arial;">Dimensions</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">330(L) × 260(W) × 160(D)mm</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="40"><strong><span style="font-family: Arial;">Weight</span></strong></td>
<td class="xl81" colspan="2"><span style="font-family: Arial;">Approx : 3760g</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-6305in-5kv-high-voltage-insulation-tester/">SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 1131IN 1kV Insulation Continuity Tester</title>
		<link>https://obiat.com.au/product/sew-1131in-1-kv-insulation-continuity-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 09:11:02 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8823</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>The SEW 1131IN is a highly compact and easy to use 1000V Analogue Insulation &#38; Continuity Tester.</p>
<h4>Features:</h4>
<ul>
<li>Rugged Taut Band meter movement</li>
<li>Designed toCAT III 600V safety standards</li>
<li>Similar to the Kyoritsu 3132A</li>
</ul>
<p><strong><span style="color: #0000ff;">Authorised Australian Distributor</span></strong></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-1131IN-Datasheet.pdf" rel="noopener">SEW-1131IN-Datasheet</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/sew-1131in-1-kv-insulation-continuity-tester/">SEW 1131IN 1kV Insulation Continuity Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="color: #0000ff; font-size: 110%;">SEW 1131IN 1kV Insulation Continuity Tester Features:</span></h4>
<p>● High quality Taut Band Meter movement.<br />
● Three insulation test voltages (DC) : 250V, 500V, 1000V.<br />
● Two ranges for continuity test : 2Ω &amp; 20Ω.<br />
● Compact and lightweight.<br />
● AC voltmeter with linear scale up to 600Vac.<br />
● 200mA continuity short-circuit current.<br />
● 1mA test current on insulation test at nominal voltage.<br />
● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.<br />
● Live warning and display of external voltage presence.<br />
● Fuse, air gap, crowbar and overload protected.<br />
● On line battery monitoring shows if battery is ok.<br />
● Manual zero ohm adjustment.<br />
● Low battery consumption.<br />
● Mirror scale.<br />
● Push and turn locking switch for continuous and hand free testing.</p>
<h4><span style="color: #0000ff; font-size: 110%;">SEW 1131IN Insulation-Continuity Tester Specifications:</span></h4>
<table width="636">
<tbody>
<tr>
<td width="216"><strong>Insulation Resistance</strong></td>
<td width="181"></td>
<td width="181"></td>
</tr>
<tr>
<td width="216"><strong>Test voltage (DC V)</strong></td>
<td colspan="2" width="362">250V     /   500V   /   1000V</td>
</tr>
<tr>
<td width="216"><strong>Output voltage on open circuit</strong></td>
<td colspan="2" width="362">Rated test voltage +10%</td>
</tr>
<tr>
<td width="216"><strong>Measuring ranges</strong></td>
<td colspan="2" width="362">0-100MΩ / 0-200MΩ / 0-400MΩ</td>
</tr>
<tr>
<td width="216"><strong>Mid-scale value</strong></td>
<td colspan="2" width="362">1MΩ     /   2MΩ     /     4MΩ</td>
</tr>
<tr>
<td width="216"><strong>Scale multiplier</strong></td>
<td colspan="2" width="362">×1/2     /     ×1       /       ×2</td>
</tr>
<tr>
<td width="216"><strong>Accuracy</strong></td>
<td colspan="2" width="362">± 5% of indicated value</td>
</tr>
<tr>
<td width="216"><strong>Output short- circuit current</strong></td>
<td colspan="2" width="362">≥ 1.0mA</td>
</tr>
<tr>
<td><strong>Continuity</strong></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Measuring ranges</strong></td>
<td colspan="2">2Ω / 20Ω</td>
</tr>
<tr>
<td><strong>zero Ω adjustment by knob</strong></td>
<td colspan="2">ˇ</td>
</tr>
<tr>
<td width="216"><strong>Output short- circuit current</strong></td>
<td colspan="2"> ≥ 200 mA</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td colspan="2">± 1.5% of scale length</td>
</tr>
<tr>
<td><strong>AC Voltage</strong></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Range</strong></td>
<td colspan="2">0-600V AC</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td colspan="2">± 3% of scale length</td>
</tr>
<tr>
<td><strong>General</strong></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Voltage warning</strong></td>
<td colspan="2" width="362">Warning light circuit live lit From 90Vdc / 70Vac, Buzzer beep from 24V ac/dc</td>
</tr>
<tr>
<td><strong>Battery check</strong></td>
<td colspan="2" width="362">Battery check indicate good batteries from 8.5Vdc to 13Vdc during a load test of 250mA.</td>
</tr>
<tr>
<td><strong>Battery OK</strong></td>
<td colspan="2" width="362">Battery OK LED lit from 8.5Vdc and is operative while testing.</td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td colspan="2">175(L) × 85(W) × 75(D)mm</td>
</tr>
<tr>
<td width="216"><strong>Weight (battery included)</strong></td>
<td colspan="2">Approx. 650g</td>
</tr>
<tr>
<td width="216"><strong>Power source</strong></td>
<td colspan="2">1.5V (AA) × 8</td>
</tr>
<tr>
<td><strong>Safety standard</strong></td>
<td colspan="2" width="362">EN 61010-1 CAT III 600V EN 61326-1</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-1131in-1-kv-insulation-continuity-tester/">SEW 1131IN 1kV Insulation Continuity Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 7015IN 15kV Digital High Voltage Insulation Tester</title>
		<link>https://obiat.com.au/product/sew-7015in-15kv-digital-high-voltage-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 07:49:28 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8813</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>The SEW 7015N Digital Cat IV (600 V) High Voltage Tester has thirty insulation test voltage levels ranging from 500 Volts to 15,000 Volts DC.</p>
<p>The SEW 7015IN suited for testing LV and MV electrical assets including high voltage motors. Insulation resistance can be measured to 2000 G-ohms, and other standard insulation tests include Dielectric Absorption Ratio (DAR) and Polarization Index (PI).</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-7015N.pdf">SEW 7015N Datasheet</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/sew-7015in-15kv-digital-high-voltage-insulation-tester/">SEW 7015IN 15kV Digital High Voltage Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>SEW 7015IN 15kV Digital High Voltage Insulation Tester is provided with a guard rail to eliminate surface leakage when testing insulation resistance of assets such as PILC cables. Internal data storage can hold 200 measurements, and the instrument’s optical USB to RS-232 transmission<br />
port allows data export to PCs via SEW’s standard CD-supplied software.</p>
<p>Standard features of the SEW 7015IN 15kV Digital High Voltage Insulation Tester include an AC/DC voltmeter as well as audible alarm for live circuits, auto ranging on all insulation resistance ranges with auto hold to freeze readings, bar graph display allowing visual observation of charging patterns, overload protection, calendar and auto-power off.</p>
<p><span style="color: #ff0000;"><strong>SEW 7015IN Features:</strong></span></p>
<p>● Test Insulation Resistance up to 2 TΩ (2000GΩ).<br />
● Short-circuit current up to 5mA.<br />
● Microprocessor controlled.<br />
● 30 insulation test voltages :<br />
500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,<br />
3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV,<br />
6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV,<br />
9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV,<br />
12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV<br />
● AC/DC Voltmeter.<br />
● PI (Polarization Index) indication.<br />
● DAR (Dielectric Absorption ratio) indication.<br />
● Auto-ranging on all insulation ranges.<br />
● Backlight function.<br />
● Bargraph indicates test voltage, rise and decay<br />
can be observed.<br />
● Menu driven.<br />
● Visual and audible warning if external voltage is<br />
present. (≥30Vac or ≥30Vdc).<br />
● Auto-hold function to freeze the reading.<br />
● Overload protection.<br />
● Adjustment for testing time (duration) : 1~30 minutes.<br />
● Auto-off.<br />
● Calendar.<br />
● Optical USB to RS-232 data transmission.<br />
● 200 measurement results can be saved in the<br />
memory and recalled on the display.<br />
● Safety standard: EN 61010-1   CAT IV 600V<br />
EN 61010-2-030<br />
EN 61326-1</p>
<h5><span style="color: #ff0000;"><strong>SEW 7015IN Specifications:</strong></span></h5>
<table border="0" width="506" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="xl66" width="196" height="53"><strong><span style="font-family: Arial;"> Test Voltage</span></strong></td>
<td class="xl67" width="310"><span style="font-family: Arial;"> From 500Vdc to 15kVdc<br />
Adjustable in 500V steps</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="33"><strong><span style="font-family: Arial;"> Preset buttons</span></strong></td>
<td class="xl73" width="310"><span style="font-family: Arial;"> 1kV, 5kV, 10kV, 15kV</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> Insulation resistance</span></strong></td>
<td class="xl73" width="310"><span style="font-family: Arial;"> 70GΩ/0.5kV<br />
70GΩ at 0.5kV~2TΩ at 15kV</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="33"><strong><span style="font-family: Arial;"> Accuracy</span></strong></td>
<td class="xl71" width="310"><span style="font-family: Arial;"> ±(5.0%rdg+5dgt) </span></td>
</tr>
<tr>
<td class="xl70" width="196" height="106"><strong><span style="font-family: Arial;"> Resolution</span></strong></td>
<td class="xl71" width="310"><span style="font-family: Arial;"> 2GΩ : 0.001GΩ<br />
20GΩ : 0.01GΩ<br />
200GΩ : 0.1GΩ<br />
2TΩ : 1GΩ</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="40"><strong><span style="font-family: Arial;"> Short circuit current</span></strong></td>
<td class="xl71" width="310"><span style="font-family: Arial;"> up to 5mA</span></td>
</tr>
<tr>
<td class="xl68" height="33"><strong><span style="font-family: Arial;"> PI (Polarization Index)</span></strong></td>
<td class="xl71" width="310"><span style="font-family: Arial;"> V</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> DAR (Dielectric  </span></strong><strong><span style="font-family: Arial;">  Absorption Ratio)</span></strong></td>
<td class="xl72"><span style="font-family: Arial;"> V</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="106"><strong><span style="font-family: Arial;"> Voltmeter</span></strong></td>
<td class="xl73" width="310"><span style="font-family: Arial;"> ACV : 0~600V (50/60Hz)<br />
DCV : 0~600V<br />
Accuracy : ±(2.0%rdg+3dgt)<br />
Resolution : 1V</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> Power source</span></strong></td>
<td class="xl72"><span style="font-family: Arial;"> Rechargeable battery</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> AC Adapter</span></strong></td>
<td class="xl73" width="310"><span style="font-family: Arial;"> Input : 100-240V~ ,0.4A ,50-60Hz<br />
Output : 24V &#8230; 0.62A</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> Dimensions</span></strong></td>
<td class="xl72"><span style="font-family: Arial;"> 430(L) x 324(W) x 127(D)mm</span></td>
</tr>
<tr>
<td class="xl74" width="196" height="40"><strong><span style="font-family: Arial;"> Weight</span></strong></td>
<td class="xl69"><span style="font-family: Arial;"> Approx : 5kg</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-7015in-15kv-digital-high-voltage-insulation-tester/">SEW 7015IN 15kV Digital High Voltage Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>