<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Safety Tester Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-tag/safety-tester/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-tag/safety-tester/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Fri, 28 Aug 2020 08:32:09 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Safety Tester Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-tag/safety-tester/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HT ITALIA FULLTEST3 Professional Multifunction Safety Tester</title>
		<link>https://obiat.com.au/product/ht-italia-fulltest3-professional-multifunction-safety-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 28 Aug 2020 08:32:09 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=60145</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2016/05/HTI-Auth-Large.jpg"><img class="alignnone size-full wp-image-4283" src="https://obiat.com.au/wp-content/uploads/2016/05/HTI-Auth-Large.jpg" alt="" width="350" height="160" /></a></p>
<p><span style="font-size: 110%;"><strong>The HT Instruments FULLTEST3 effects all tests required by IEC/EN60204-1:2006 and IEC/EN61439 in a simple, reliable and fast way.</strong></span></p>
<p>The FULLTEST3 also carries out a considerable number of safety tests that makes it as a flexible solution also in compliance with other standards.</p>
<p>Besides continuity of protection conductors, insulation and withstanding, FULLTEST3 tests type A, AC, and B general, selective and delayed RCDs, curve B, C, D, and K MCBs and type gG and aM fuses, line/fault impedance with standard or high resolution, non-trip earth loop impedance, leakage current, etc.</p>
<p>FULLTEST3 is provided with innovative interfaces such as a colour touch-screen graphical display, 3 USB ports for PC connection, a USB memory stick, a USB printer and bar code readers.</p>
<p style="text-align: center;"><span style="text-decoration: underline;"><span style="font-size: 110%;"><strong>The FULLTEST3 is the ideal partner for designers, manufacturers and installers.</strong></span></span></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://obiat.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Datasheet.pdf" rel="noopener noreferrer">HT FULLTEST3 Datasheet</a></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Brochure.pdf" rel="noopener noreferrer">HT FULLTEST3 Brochure</a></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="text-decoration: underline;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-User-Manual.pdf" rel="noopener noreferrer">HT FULLTEST3 User Manual</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/ht-italia-fulltest3-professional-multifunction-safety-tester/">HT ITALIA FULLTEST3 Professional Multifunction Safety Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><b>FULLTEST 3 is the Most Advanced Solution for a Complete Compliance with the Actual Guidelines</b></p>
<p>Multifunction Tester for safety of machinery IEC/EN60204-1:2016 and low voltage switchgears and controlgears IEC/EN61439-1-2:2011</p>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel.jpg"><img fetchpriority="high" decoding="async" class="wp-image-16402 alignnone" src="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST5-Front-Panel-300x213.jpg" alt="" width="500" height="355" /></a></p>
<p><strong>IEC/EN60204-1:2016 Measuments:</strong></p>
<p><strong>Power Frequency Dielectric withstand voltage</strong> with test voltage of <strong>1000VAC</strong></p>
<p><strong>Testing protection against indirect contact:</strong></p>
<ul>
<li>Continuity of protective conductors with test current 200mA</li>
<li>Automatic disconnection of the supply (RCD, MCB, Fuse)​</li>
<li>RCD tripping (RCD AC, A, B) up to 1A on TT Systems</li>
<li>Magneto-thermal protections (MCB curve verificaiton on B, C, D, K) and fuses (gG, aM) on TN Systems</li>
</ul>
<p><strong>​Insulation resistance measurement with test voltage of 500VDC</strong></p>
<p><strong>Discharging of residual voltage V&lt;60V in 5sec/1sec</strong></p>
<p><strong>IEC/EN61439-1-2:2011 Measurements:</strong></p>
<p><strong>Clearances and Creepage distances:</strong></p>
<ul>
<li>Dielectric withstand voltage with test voltage of up to 3400/5100VAC</li>
</ul>
<p><strong>Continuity of earth system and protective conductors</strong> ≥10A</p>
<p><strong>Power Frequency Dielectric withstand voltage</strong> with test voltage of <strong>1800VAC</strong></p>
<p><strong>Alternative power-frequency voltage test up to 5100VAC</strong></p>
<p><strong>Test on enclosures of insulating material:</strong></p>
<ul>
<li><strong>​</strong>Dielectric Withstand voltage with test voltage up to <strong>2835V</strong></li>
</ul>
<p><strong>Discharging of residual voltage V&lt;60V in 5sec/1sec</strong></p>
<p>FULLTEST3 is designed to satisfy the requirements of the IEC/EN60204-1:2006 guideline (electrical equipment of industrial machines) and for the new series of prescriptions relative to the IEC/EN61439-1 guideline (Switchgear panels). This last guideline require, among other tests, the Dielectric tests with a test voltage up to 5100V!</p>
<h3><strong>FULLTEST3 Features:</strong></h3>
<ul>
<li>Continuity of protection conductors with 200mA</li>
<li>Continuity of protection conductors with I&gt;10A, V&lt;12V AC</li>
<li>Continuity of protection conductors with I&gt;25A, V&lt;12V AC</li>
<li>Insulation Resistance with 100,250,500,1000VDC test voltage</li>
<li>Withstanding test with test voltage programmable from 250V to 5100V AC</li>
<li>Discharging time test on internal capacitance and on power supply plug</li>
<li>Leakage/absorbed and power on the test socket</li>
<li>Leakage current with external clamp (HT96U optional accessories)</li>
<li>Test on RCDs type A, AC, B General, Selective, Delayed up to 1000mA</li>
<li>Line/Loop impedance and Ipsc calculation</li>
<li>Line/Loop impedance with high resolution (with IMP57 optional accessories)</li>
<li>Test on MCB protection with curve B, C, D, K and Fuse type gG and aM</li>
<li>Selection of length, cable type, insulation of cable, tripping time of protection device</li>
<li>Global earth resistance without RCD tripping</li>
<li>Phase sequence indication</li>
<li>TFT display with touch-screen</li>
<li>Programmable timer on tests</li>
<li>Programmable thresholds on measurement</li>
<li>Internal memory</li>
<li>USB interface for PC connection</li>
<li>USB interface for keyboard, printer and barcode reader connection</li>
</ul>
<h3>Test to Guidelines:</h3>
<div class="col-sx-12 col-md-12 col-lg-12 nopadding_right nopadding_left">
<ul>
<li><i class="fa fa-check"></i> CEI 64-8</li>
<li><i class="fa fa-check"></i> CEI 64-8/7</li>
<li><i class="fa fa-check"></i> CE MARK</li>
<li><i class="fa fa-check"></i> EMC 2014/30/EU</li>
<li><i class="fa fa-check"></i> EMC: IEC/EN61326</li>
<li><i class="fa fa-check"></i> EN50106</li>
<li><i class="fa fa-check"></i> IEC/EN60204-1</li>
<li><i class="fa fa-check"></i> IEC/EN60598-1</li>
<li><i class="fa fa-check"></i> IEC/EN61010-1</li>
<li><i class="fa fa-check"></i> IEC/EN61187</li>
<li><i class="fa fa-check"></i> IEC/EN61335-1</li>
<li><i class="fa fa-check"></i> IEC/EN61439-1</li>
<li><i class="fa fa-check"></i> IEC/EN61439-2</li>
<li><i class="fa fa-check"></i> IEC/EN61557-1</li>
<li><i class="fa fa-check"></i> IEC/EN61557-13</li>
<li><i class="fa fa-check"></i> IEC/EN61557-14</li>
<li><i class="fa fa-check"></i> IEC/EN61557-2</li>
<li><i class="fa fa-check"></i> IEC/EN61557-3</li>
<li><i class="fa fa-check"></i> IEC/EN61557-4</li>
<li><i class="fa fa-check"></i> IEC/EN61557-6</li>
<li><i class="fa fa-check"></i> IEC/EN61557-7</li>
<li><i class="fa fa-check"></i> LVD 2014/35/EU</li>
<li><i class="fa fa-check"></i> UNE20460</li>
</ul>
</div>
<h3>Standard Accessories:</h3>
<ul>
<li>Australian Power cord</li>
<li>Test cable red, 3 metre, 2 pcs</li>
<li>Test cable blue, 3 metre</li>
<li>Test cable green, 3 metre</li>
<li>C2033X : Cable 3 wires with Shuko plug</li>
<li>Cable with 5kV safety, 2 pcs</li>
<li>Test lead CAT III, 3 pcs</li>
<li>Test lead CAT II, 3 pcs</li>
<li>Alligator clip, 3pcs</li>
<li>TOPVIEW2007 : Windows software + USB cable C2007</li>
<li>Carry bag for accessories</li>
<li>ISO9000 calibration certificate</li>
</ul>
<h3>Optional Accessories:</h3>
<ul>
<li>IMP57 : Accessory for high resolution Loop/Line Impedance</li>
<li>HT96U : Rigid clamp 1-100-1000A AC, diameter 54mm</li>
</ul>
<p><a href="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner.jpg"><img decoding="async" class="aligncenter wp-image-16404 size-large" src="https://rapid-tech.com.au/wp-content/uploads/2020/08/HT-FULLTEST3-Accesories-banner-1024x283.jpg" alt="" width="1020" height="282" /></a></p>
<p>The post <a href="https://obiat.com.au/product/ht-italia-fulltest3-professional-multifunction-safety-tester/">HT ITALIA FULLTEST3 Professional Multifunction Safety Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		