<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SEW Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-tag/sew/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-tag/sew/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Mon, 21 May 2018 21:36:05 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>SEW Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-tag/sew/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER</title>
		<link>https://obiat.com.au/product/sew-6305in-5kv-high-voltage-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 20 May 2018 08:08:59 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8836</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<h4><span style="color: #ff0000; font-size: 110%;"><strong>SEW 6305IN Features</strong></span></h4>
<p>● High contrast OLED display<br />
● Microprocessor-controlled<br />
● Tests insulation resistance up to 10 TΩ<br />
● 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V<br />
● AC / DC Voltmeter<br />
● Short-circuit current up to 5mA<br />
● PI (Polarization Index) indication<br />
● DAR (Dielectric Absorption Ratio) indication<br />
● Auto-ranging on all insulation ranges<br />
● Optical USB to RS-232 data transmission<br />
● Well isolated from contact<br />
● Well protected from surges<br />
● 2 built-in optical LEDs for data transfer<br />
● Visual &#38; audio warning of external voltage presence (≥30Vac or ≥30Vdc)<br />
● Auto-hold function to freeze reading<br />
● Overload protection<br />
● Adjustable testing duration: 1~30 minutes<br />
● Internal memory for data storage<br />
● Displays testing duration for insulation measurement<br />
● Auto-off function<br />
● 200 measurement results can be saved in memory and recalled</p>
<p><span style="color: #0000ff;"><strong>Authorised Australian Distributor</strong></span></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-6305IN-Datasheet.pdf" rel="noopener">SEW-6305IN-Datasheet</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/sew-6305in-5kv-high-voltage-insulation-tester/">SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="color: #0000ff; font-size: 110%;">SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER SPECIAL FUNCTIONS</span></h4>
<p><strong><span style="color: #0000ff;">Voltmeter</span><br />
</strong>Conventional insulation testers are highly susceptible to damage when testing insulation resistance while voltage is present on the measured object (whether ACV or DCV). To safely prevent damage, the SEW 6305IN has the unique ability to sense voltage on a measured object. If any voltage is sensed, the tester will automatically switch to voltage detection mode and display the voltage finding on the LCD screen. This allows the user to prevent damage caused by attempting to measure insulation resistance while voltage is present.</p>
<p><strong><span style="color: #0000ff;">DAR = Dielectric Absorption Ratio</span><br />
</strong>The Dielectric Absorption Ratio is the ratio of the insulation resistance measured at 1 minute divided by the insulation resistance measured at 30 seconds. Thirty seconds after starting a test, SEW 6305IN will beep, indicating that the resistance value measured at 30 seconds has been saved. One minute after starting a test, the tester will beep again, indicating that the DAR result has been computed. The display format then changes to display the DAR result.</p>
<p><img decoding="async" class="alignnone wp-image-4647" src="http://rapid-tech.com.au/wp-content/uploads/2017/01/SEW-6305IN-B.jpg" alt="SEW 6305IN B" width="321" height="75" /></p>
<p><strong><span style="color: #0000ff;">PI = Polarization Index</span><br />
</strong>The Polarization Index is the ratio of the insulation resistance measured at 10 minutes divided by the insulation resistance measured at 1 minute. One minute after starting a test, the resistance value is saved and the DAR is displayed. The test then continues, and after 10 minutes, the SEW 6305IN will beep again, indicating that the PI result has been computed. The display format changes to display the PI result.</p>
<p><img decoding="async" class="alignnone wp-image-4648" src="http://rapid-tech.com.au/wp-content/uploads/2017/01/SEW-6305IN-C.jpg" alt="SEW 6305IN C" width="303" height="57" /></p>
<p>Note: Tests on lower insulation resistance take longer, which tends to deteriorate the test specimen. Thus, higher DAR or PI readings (closer to 1) would indicate a better grade of insulation.</p>
<h4><span style="color: #0000ff; font-size: 110%;">SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER SPECIFICATIONS:</span></h4>
<table border="0" width="606" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="xl66" width="196" height="53"><strong><span style="font-family: Arial;">Test Voltage</span></strong></td>
<td class="xl76" colspan="2" width="410"><span style="font-family: Arial;">500V, 1000V, 2500V, 5000V</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="107"><strong><span style="font-family: Arial;">Insulation resistance</span></strong></td>
<td class="xl78" colspan="2" width="410"><span style="font-family: Arial;">1TΩ / 500V<br />
2TΩ / 1000V<br />
5TΩ / 2500V<br />
10TΩ / 5000V</span></td>
</tr>
<tr>
<td class="xl83" rowspan="2" width="196" height="160"><strong><span style="font-family: Arial;">Accuracy</span></strong></td>
<td class="xl71" width="205"><span style="font-family: Arial;">0~100GΩ / 500V<br />
0~200GΩ / 1000V<br />
0~500GΩ / 2500V<br />
0~1000GΩ / 5000V</span></td>
<td class="xl69" width="205"><span style="font-family: Arial;">±(5%rdg+5dgt) </span></td>
</tr>
<tr>
<td class="xl71" width="205" height="80"><span style="font-family: Arial;">100G~1TΩ / 500V<br />
200G~2TΩ / 1000V<br />
500G~5TΩ / 2500V<br />
1000G~10TΩ / 5000V</span></td>
<td class="xl69" width="205"><span style="font-family: Arial;">±12%rdg</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="106"><strong><span style="font-family: Arial;">Resolution</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">1000MΩ: 1MΩ<br />
10GΩ: 0.01GΩ<br />
100GΩ: 0.1GΩ<br />
1TΩ: 1GΩ<br />
10TΩ: 10GΩ</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="40"><strong><span style="font-family: Arial;">Short circuit current</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">up to 5mA</span></td>
</tr>
<tr>
<td class="xl67" height="33"><strong><span style="font-family: Arial;">PI (Polarization Index)</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">V</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="53"><strong><span style="font-family: Arial;">DAR (Dielectric Absorption Ratio)</span></strong></td>
<td class="xl79" colspan="2"><span style="font-family: Arial;">V</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="107"><strong><span style="font-family: Arial;">Voltmeter</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">ACV: 30~600V (50/60Hz)<br />
DCV: 30~600V<br />
Accuracy: ±(2.0%rdg + 3dgt)<br />
Resolution: 1V</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="42"><strong><span style="font-family: Arial;">Current<br />
measurement</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">0.5nA ~ 0.55mA<br />
(Depending on the insulation resistance)</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="53"><strong><span style="font-family: Arial;">Power source</span></strong></td>
<td class="xl79" colspan="2"><span style="font-family: Arial;">Rechargeable battery</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="53"><strong><span style="font-family: Arial;">AC Adapter</span></strong></td>
<td class="xl78" colspan="2" width="410"><span style="font-family: Arial;">Input: 100-240Vac, 0.4A, 50-60Hz<br />
Output: 24Vdc, 0.62A</span></td>
</tr>
<tr>
<td class="xl68" width="196" height="53"><strong><span style="font-family: Arial;">Dimensions</span></strong></td>
<td class="xl74" colspan="2" width="410"><span style="font-family: Arial;">330(L) × 260(W) × 160(D)mm</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="40"><strong><span style="font-family: Arial;">Weight</span></strong></td>
<td class="xl81" colspan="2"><span style="font-family: Arial;">Approx : 3760g</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-6305in-5kv-high-voltage-insulation-tester/">SEW 6305IN 5kV HIGH VOLTAGE INSULATION TESTER</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 8012EL Microprocessor Controlled RCD Tester</title>
		<link>https://obiat.com.au/product/sew-8012el-microprocessor-controlled-rcd-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 10:17:12 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8832</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>The SEW 8012EL is a full featured Microprocessor-controlled RCD tester at a realistic price.</p>
<p>The SEW 8012EL has a wiring polarity indicator and can measure voltage between Line and Earth before testing as well as indicating line frequency.</p>
<p>With it's easy to see extra large backlit LCD (78 × 67mm) and low power consumption make the SEW 8012EL ideal for domestic and commercial environments.</p>
<p><span style="color: #0000ff;"><strong>Authorised Australian Distributor</strong></span></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-8012EL-Datasheet.pdf" rel="noopener"><span style="font-size: 110%;">SEW-8012EL-Datasheet</span></a></h4>
<p>The post <a href="https://obiat.com.au/product/sew-8012el-microprocessor-controlled-rcd-tester/">SEW 8012EL Microprocessor Controlled RCD Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The majority of electrical fatalities could have been prevented by the use of a properly installed Residual Current Device (RCD) , and regular testing to ensure they are working correctly.</p>
<p>RCD’s also protect against fire caused by faults in appliance, tools and wiring. If these faults go undetected they could cause a fire or personal injury. RCD’s provide a means of early fault detection.</p>
<h4><span style="color: #0000ff; font-size: 110%;">SEW 8012EL Microprocessor Controlled RCD Tester Features:</span></h4>
<p>● Menu-driven.<br />
● Accurate digital readout of disconnection time.<br />
● Over temperature protection.<br />
● Over voltage protection.<br />
● Fuse protection.<br />
● Zero crossing circuitry permit testing at 0° or 180°.<br />
●Extra large LCD(78 × 67mm).<br />
● Very low consumption.<br />
● 50Hz and 60Hz operation<br />
● Auto power off.<br />
● Auto off and off override.<br />
● Wiring polarity indicator.<br />
● Measure voltage between Line and Earth before testing.<br />
●Frequency measurement indication.</p>
<h4><span style="color: #0000ff; font-size: 110%;">SEW 8012EL Microprocessor Controlled RCD Tester Specifications:</span></h4>
<table border="0" width="589" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="xl66" width="227" height="93"><strong><span style="font-family: Arial;">Operating voltage (L-E)<br />
(50Hz or 60 Hz)</span></strong></td>
<td class="xl76" colspan="2" width="362"><span style="font-family: Arial;"> Version A : 240 Vac<br />
Version B : 230 Vac<br />
Version C : 220 Vac<br />
Version D : 110 Vac</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="53"><strong><span style="font-family: Arial;"> Current settings</span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> 3mA, 5mA, 10mA, 15mA, 20mA, 30mA, 50mA,  100mA,  150mA, 250mA, 300mA,  500mA.</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="33"><strong><span style="font-family: Arial;"> Current selection</span></strong></td>
<td class="xl78" colspan="2"><span style="font-family: Arial;"> Rotary switch selector</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="33"><strong><span style="font-family: Arial;"> Phase angle setting</span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> 0° and 180° selectable</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="53"><strong><span style="font-family: Arial;">Wiring correctness indication</span></strong></td>
<td class="xl78" colspan="2"><span style="font-family: Arial;"> Yes (LEDs)</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="33"><strong><span style="font-family: Arial;"> Trip indicator</span></strong></td>
<td class="xl78" colspan="2"><span style="font-family: Arial;"> Yes (LCD)</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="53"><strong><span style="font-family: Arial;"> Over-temperature protection</span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> Yes </span></td>
</tr>
<tr>
<td class="xl71" width="227" height="53"><strong><span style="font-family: Arial;"> Voltmeter (L-E)</span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> 10Vac ~ 280Vac<br />
(50Hz or 60Hz)</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="53"><strong><span style="font-family: Arial;"> Timer resolution</span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> 1ms (Max. Time=2.999s)</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="33"><strong><span style="font-family: Arial;"> Timer accuracy</span></strong></td>
<td class="xl78" colspan="2"><span style="font-family: Arial;"> ±2ms</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="33"><strong><span style="font-family: Arial;"> Current accuracy</span></strong></td>
<td class="xl78" colspan="2"><span style="font-family: Arial;"> ±5% ±1mA</span></td>
</tr>
<tr>
<td class="xl71" width="227" height="33"><strong><span style="font-family: Arial;"> Voltmeter resolution</span></strong></td>
<td class="xl78" colspan="2"><span style="font-family: Arial;"> 1Vac</span></td>
</tr>
<tr>
<td class="xl67" height="33"><strong><span style="font-family: Arial;"> Voltmeter accuracy </span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> ±2%±1Vac</span></td>
</tr>
<tr>
<td class="xl69" width="227" height="33"><strong><span style="font-family: Arial;"> Operating temperature</span></strong></td>
<td class="xl77" colspan="2" width="362"><span style="font-family: Arial;"> -0°C ~ 40°C</span></td>
</tr>
<tr>
<td class="xl69" width="227" height="33"><strong><span style="font-family: Arial;"> Storage temperature</span></strong></td>
<td class="xl77" colspan="2" width="362"><span style="font-family: Arial;"> -10°C ~ 50°C</span></td>
</tr>
<tr>
<td class="xl69" width="227" height="33"><strong><span style="font-family: Arial;"> Dimensions</span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> 221(L) × 110(W) × 57(D)mm</span></td>
</tr>
<tr>
<td class="xl69" width="227" height="46"><strong><span style="font-family: Arial;"> Weight<br />
(battery included)</span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> Approx. 695g</span></td>
</tr>
<tr>
<td class="xl69" width="227" height="53"><strong><span style="font-family: Arial;"> Power source</span></strong></td>
<td class="xl73" colspan="2" width="362"><span style="font-family: Arial;"> 1.5V (AA) × 6<br />
(Alkaline battery)</span></td>
</tr>
<tr>
<td class="xl68" height="53"><strong><span style="font-family: Arial;"> Safety standard</span></strong></td>
<td class="xl72" colspan="2" width="362"><span style="font-family: Arial;"> EN 61010-1 CAT III 300V<br />
EN 61326-1</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-8012el-microprocessor-controlled-rcd-tester/">SEW 8012EL Microprocessor Controlled RCD Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 8025LP LOOP &#038; PSC TESTER</title>
		<link>https://obiat.com.au/product/sew-8025lp-loop-psc-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 09:59:38 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8828</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>● 3 ½ digit LCD (2000-count).<br />
● Backlight function.<br />
● 15mA loop measurement which will not trip ELCBs.<br />
● Convenient and easy for users to measure the loop impedance directly without bypassing the wires.<br />
● Wiring check function.<br />
● Over temperature protection.<br />
● Over voltage protection.<br />
● Built-in voltmeter.<br />
● Built-in earth tester.<br />
● Built-in loop/psc tester.<br />
● Includes the TNT-EL Mains Lead<br />
● Safety standard :<br />
EN 61010-1 CAT III 300V<br />
EN 61326-1</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-8025LP-Datasheet.pdf" rel="noopener"><span style="font-size: 110%;">SEW 8025LP Datasheet</span></a></h4>
<p>The post <a href="https://obiat.com.au/product/sew-8025lp-loop-psc-tester/">SEW 8025LP LOOP &#038; PSC TESTER</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><strong>SEW 8025LP Earth fault loop impedance testing</strong></h4>
<p>Earth fault loop impedance is the path followed by fault current when a low impedance fault occurs between the phase conductor and earth, i.e. “earth fault loop”. Fault current is driven round the loop by the supply voltage. The higher the impedance, the lower the fault current will be and the longer it will take for the circuit protection to operate.</p>
<p>To make sure the protection operates fast enough, the loop impedance must be low. Every circuit must be tested to make sure that the actual loop impedance does not exceed that specified for the protective device concerned.</p>
<h4><strong>Prospective short circuit current (PSC) testing</strong></h4>
<p>The prospective short circuit or fault current at any point in an electrical installation is the current that would flow in the circuit if no circuit protection operated and a complete (very low impedance) short circuit occurred. The value of this fault current is determined by the supply voltage and the impedance of the path taken by the fault current. Measurement of PSC can be used to check that protective devices within the system will operate within safety limits and as per the safe design of the installation. PSC is normally measured between the phase and neutral.</p>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-4665" src="http://rapid-tech.com.au/wp-content/uploads/2017/01/8025LP-Layout.jpg" alt="8025LP Layout" width="395" height="458" /></p>
<p><img decoding="async" class="alignnone wp-image-4668" src="http://rapid-tech.com.au/wp-content/uploads/2017/01/SEW-TNT-EL.jpg" alt="SEW TNT-EL" width="190" height="145" /><br />
<strong>The TNT-EL mains lead supplied with SEW 8025LP</strong></p>
<h4><span style="color: #0000ff; font-size: 110%;">SEW 8025LP Specifications:</span></h4>
<table border="0" width="684" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="xl107" width="170" height="40"><strong><span style="font-family: Arial;">Loop Impedance</span></strong></td>
<td class="xl107" width="145"></td>
<td class="xl72" width="188"></td>
<td class="xl70" width="181"></td>
</tr>
<tr>
<td class="xl75" width="170" height="66">
<p align="center"><strong><span style="font-family: Arial;">Range</span></strong></p>
</td>
<td class="xl76" width="145">
<p align="center"><strong><span style="font-family: Arial;">Measuring<br />
range</span></strong></p>
</td>
<td class="xl80" width="188">
<p align="center"><strong><span style="font-family: Arial;">Nominal test current at 0 Ω external loop</span></strong></p>
</td>
<td class="xl77">
<p align="center"><strong><span style="font-family: Arial;">Accuracy</span></strong></p>
</td>
</tr>
<tr>
<td class="xl78" width="170" height="33">
<p align="center"><span style="font-family: Arial;">20 Ω</span></p>
</td>
<td class="xl79" width="145">
<p align="center"><span style="font-family: Arial;">0.00~19.99 Ω</span></p>
</td>
<td class="xl66" width="188">
<p align="center"><span style="font-family: Arial;">23A / 40ms</span></p>
</td>
<td class="xl91" rowspan="3">
<p align="center"><span style="font-family: Arial;">(2%rdg + 4dgt)</span></p>
</td>
</tr>
<tr>
<td class="xl78" width="170" height="33">
<p align="center"><span style="font-family: Arial;">200 Ω</span></p>
</td>
<td class="xl79" width="145">
<p align="center"><span style="font-family: Arial;">0.0~199.9 Ω</span></p>
</td>
<td class="xl66" width="188">
<p align="center"><span style="font-family: Arial;">2.3A / 40ms</span></p>
</td>
</tr>
<tr>
<td class="xl81" width="170" height="33">
<p align="center"><span style="font-family: Arial;">2000 Ω</span></p>
</td>
<td class="xl82" width="145">
<p align="center"><span style="font-family: Arial;">0~1999 Ω</span></p>
</td>
<td class="xl85">
<p align="center"><span style="font-family: Arial;">15mA / 400ms</span></p>
</td>
</tr>
<tr>
<td class="xl108" colspan="4" width="684" height="46"><strong><span style="font-family: Arial;">Prospective Short-circuit Current</span></strong></td>
</tr>
<tr>
<td class="xl75" width="170" height="66">
<p align="center"><strong><span style="font-family: Arial;">Range</span></strong></p>
</td>
<td class="xl76" width="145">
<p align="center"><strong><span style="font-family: Arial;">Measuring<br />
range</span></strong></p>
</td>
<td class="xl80" width="188">
<p align="center"><strong><span style="font-family: Arial;">Nominal test current at 0 Ω external loop</span></strong></p>
</td>
<td class="xl77">
<p align="center"><strong><span style="font-family: Arial;">Accuracy</span></strong></p>
</td>
</tr>
<tr>
<td class="xl78" width="170" height="33">
<p align="center"><span style="font-family: Arial;">20 KA</span></p>
</td>
<td class="xl79" width="145">
<p align="center"><span style="font-family: Arial;">0.00~4.00 KA</span></p>
</td>
<td class="xl66" width="188">
<p align="center"><span style="font-family: Arial;">23A / 40ms</span></p>
</td>
<td class="xl100" rowspan="3" width="181">
<p align="center"><span style="font-family: Arial;">Consider accuracy of loop impedance</span></p>
</td>
</tr>
<tr>
<td class="xl78" width="170" height="33">
<p align="center"><span style="font-family: Arial;">2000 A</span></p>
</td>
<td class="xl79" width="145">
<p align="center"><span style="font-family: Arial;">0~1999 A</span></p>
</td>
<td class="xl66" width="188">
<p align="center"><span style="font-family: Arial;">23A / 40ms</span></p>
</td>
</tr>
<tr>
<td class="xl81" width="170" height="33">
<p align="center"><span style="font-family: Arial;">200 A</span></p>
</td>
<td class="xl82" width="145">
<p align="center"><span style="font-family: Arial;">0.0~199.9 A</span></p>
</td>
<td class="xl85">
<p align="center"><span style="font-family: Arial;">2.3A / 40ms</span></p>
</td>
</tr>
<tr>
<td class="xl108" width="170" height="46"><strong><span style="font-family: Arial;">Voltage Display</span></strong></td>
<td class="xl104" width="145"><strong><span style="font-family: Arial;">　</span></strong></td>
<td class="xl83" width="188"><span style="font-family: Arial;">　</span></td>
<td class="xl105"><span style="font-family: Arial;">　</span></td>
</tr>
<tr>
<td class="xl84" width="170" height="66">
<p align="center"><strong><span style="font-family: Arial;">Measuring range</span></strong></p>
</td>
<td class="xl106" width="145">
<p align="center"><strong><span style="font-family: Arial;">Accuracy</span></strong></p>
</td>
<td class="xl80" colspan="2" width="369">
<p align="center"><strong><span style="font-family: Arial;">Remark</span></strong></p>
</td>
</tr>
<tr>
<td class="xl81" width="170" height="33">
<p align="center"><span style="font-family: Arial;">150~260 V</span></p>
</td>
<td class="xl82" width="145">
<p align="center"><span style="font-family: Arial;">(2%rdg + 4dgt)</span></p>
</td>
<td class="xl85" colspan="2">
<p align="center"><span style="font-family: Arial;">at 0 Ω external loop</span></p>
</td>
</tr>
<tr>
<td class="xl111" height="46"><strong><span style="font-family: Arial;">General</span></strong></td>
<td class="xl110"><strong><span style="font-family: Arial;">　</span></strong></td>
<td class="xl83" width="188"><span style="font-family: Arial;">　</span></td>
<td class="xl105"><span style="font-family: Arial;">　</span></td>
</tr>
<tr>
<td class="xl74" width="170" height="33"><strong><span style="font-family: Arial;">Temperature</span></strong></td>
<td class="xl88" colspan="3" width="514"><span style="font-family: Arial;">0 ~ 40 °C</span></td>
</tr>
<tr>
<td class="xl73" rowspan="2" height="66"><strong><span style="font-family: Arial;">System voltage</span></strong></td>
<td class="xl115" rowspan="2"><span style="font-family: Arial;">230V</span></td>
<td class="xl86" colspan="2" width="369"><span style="font-family: Arial;">+13%</span></td>
</tr>
<tr>
<td class="xl86" colspan="2" width="369" height="33"><span style="font-family: Arial;">-15%<br />
</span></td>
</tr>
<tr>
<td class="xl73" height="33"><strong><span style="font-family: Arial;">System frequency </span></strong></td>
<td class="xl117" colspan="3"><span style="font-family: Arial;">50Hz</span></td>
</tr>
<tr>
<td class="xl68" width="170" height="53"><strong><span style="font-family: Arial;">None Battery system voltage</span></strong></td>
<td class="xl117" colspan="3"><span style="font-family: Arial;">150V ~ 260V</span></td>
</tr>
<tr>
<td class="xl68" width="170" height="53"><strong><span style="font-family: Arial;">Over Temperature Protection</span></strong></td>
<td class="xl89" colspan="3" width="514"><span style="font-family: Arial;">When overheating,the &#8221; <img decoding="async" class="" src="http://www.sew.com.tw/ezfiles/sew1/img/img/174697/8025LP03252015.jpg" width="36" height="29" border="0" /> &#8221;  symbol will show on the LCD, and the 8025LP stop measuring.<br />
</span></td>
</tr>
<tr>
<td class="xl73" rowspan="3" height="119"><strong><span style="font-family: Arial;">Wiring check</span></strong></td>
<td class="xl112"><span style="font-family: Arial;">P-E</span></td>
<td class="xl102" colspan="2" rowspan="2" width="369"><span style="font-family: Arial;">LEDs illuminate when the wiring polarity of circuit under test is correct</span></td>
</tr>
<tr>
<td class="xl112" height="33"><span style="font-family: Arial;">P-N</span></td>
</tr>
<tr>
<td class="xl112" height="53"><span style="font-family: Arial;">N-E</span></td>
<td class="xl86" colspan="2" width="369"><span style="font-family: Arial;">LED is light when P and N are reversed or the Earth is not connected.</span></td>
</tr>
<tr>
<td class="xl67" width="170" height="80"><strong><span style="font-family: Arial;">15mA Loop measurement </span></strong></td>
<td class="xl97" colspan="3" width="514"><span style="font-family: Arial;">Loop impedance 2000Ω range measurement is carried out with low test current (15mA).<br />
The current will not cause tripping out for ELCBs.</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-8025lp-loop-psc-tester/">SEW 8025LP LOOP &#038; PSC TESTER</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 1131IN 1kV Insulation Continuity Tester</title>
		<link>https://obiat.com.au/product/sew-1131in-1-kv-insulation-continuity-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 09:11:02 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8823</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>The SEW 1131IN is a highly compact and easy to use 1000V Analogue Insulation &#38; Continuity Tester.</p>
<h4>Features:</h4>
<ul>
<li>Rugged Taut Band meter movement</li>
<li>Designed toCAT III 600V safety standards</li>
<li>Similar to the Kyoritsu 3132A</li>
</ul>
<p><strong><span style="color: #0000ff;">Authorised Australian Distributor</span></strong></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-1131IN-Datasheet.pdf" rel="noopener">SEW-1131IN-Datasheet</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/sew-1131in-1-kv-insulation-continuity-tester/">SEW 1131IN 1kV Insulation Continuity Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="color: #0000ff; font-size: 110%;">SEW 1131IN 1kV Insulation Continuity Tester Features:</span></h4>
<p>● High quality Taut Band Meter movement.<br />
● Three insulation test voltages (DC) : 250V, 500V, 1000V.<br />
● Two ranges for continuity test : 2Ω &amp; 20Ω.<br />
● Compact and lightweight.<br />
● AC voltmeter with linear scale up to 600Vac.<br />
● 200mA continuity short-circuit current.<br />
● 1mA test current on insulation test at nominal voltage.<br />
● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.<br />
● Live warning and display of external voltage presence.<br />
● Fuse, air gap, crowbar and overload protected.<br />
● On line battery monitoring shows if battery is ok.<br />
● Manual zero ohm adjustment.<br />
● Low battery consumption.<br />
● Mirror scale.<br />
● Push and turn locking switch for continuous and hand free testing.</p>
<h4><span style="color: #0000ff; font-size: 110%;">SEW 1131IN Insulation-Continuity Tester Specifications:</span></h4>
<table width="636">
<tbody>
<tr>
<td width="216"><strong>Insulation Resistance</strong></td>
<td width="181"></td>
<td width="181"></td>
</tr>
<tr>
<td width="216"><strong>Test voltage (DC V)</strong></td>
<td colspan="2" width="362">250V     /   500V   /   1000V</td>
</tr>
<tr>
<td width="216"><strong>Output voltage on open circuit</strong></td>
<td colspan="2" width="362">Rated test voltage +10%</td>
</tr>
<tr>
<td width="216"><strong>Measuring ranges</strong></td>
<td colspan="2" width="362">0-100MΩ / 0-200MΩ / 0-400MΩ</td>
</tr>
<tr>
<td width="216"><strong>Mid-scale value</strong></td>
<td colspan="2" width="362">1MΩ     /   2MΩ     /     4MΩ</td>
</tr>
<tr>
<td width="216"><strong>Scale multiplier</strong></td>
<td colspan="2" width="362">×1/2     /     ×1       /       ×2</td>
</tr>
<tr>
<td width="216"><strong>Accuracy</strong></td>
<td colspan="2" width="362">± 5% of indicated value</td>
</tr>
<tr>
<td width="216"><strong>Output short- circuit current</strong></td>
<td colspan="2" width="362">≥ 1.0mA</td>
</tr>
<tr>
<td><strong>Continuity</strong></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Measuring ranges</strong></td>
<td colspan="2">2Ω / 20Ω</td>
</tr>
<tr>
<td><strong>zero Ω adjustment by knob</strong></td>
<td colspan="2">ˇ</td>
</tr>
<tr>
<td width="216"><strong>Output short- circuit current</strong></td>
<td colspan="2"> ≥ 200 mA</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td colspan="2">± 1.5% of scale length</td>
</tr>
<tr>
<td><strong>AC Voltage</strong></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Range</strong></td>
<td colspan="2">0-600V AC</td>
</tr>
<tr>
<td><strong>Accuracy</strong></td>
<td colspan="2">± 3% of scale length</td>
</tr>
<tr>
<td><strong>General</strong></td>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Voltage warning</strong></td>
<td colspan="2" width="362">Warning light circuit live lit From 90Vdc / 70Vac, Buzzer beep from 24V ac/dc</td>
</tr>
<tr>
<td><strong>Battery check</strong></td>
<td colspan="2" width="362">Battery check indicate good batteries from 8.5Vdc to 13Vdc during a load test of 250mA.</td>
</tr>
<tr>
<td><strong>Battery OK</strong></td>
<td colspan="2" width="362">Battery OK LED lit from 8.5Vdc and is operative while testing.</td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td colspan="2">175(L) × 85(W) × 75(D)mm</td>
</tr>
<tr>
<td width="216"><strong>Weight (battery included)</strong></td>
<td colspan="2">Approx. 650g</td>
</tr>
<tr>
<td width="216"><strong>Power source</strong></td>
<td colspan="2">1.5V (AA) × 8</td>
</tr>
<tr>
<td><strong>Safety standard</strong></td>
<td colspan="2" width="362">EN 61010-1 CAT III 600V EN 61326-1</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-1131in-1-kv-insulation-continuity-tester/">SEW 1131IN 1kV Insulation Continuity Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW PD-28 HIGH VOLTAGE PROBE 40kVDC-28kVAC</title>
		<link>https://obiat.com.au/product/sew-pd-28-high-voltage-probe-40kvdc-28kvac/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 08:51:26 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8816</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p><strong>SEW PD-28 High Voltage Probe (40kV DC or 28kV AC)</strong></p>
<ul>
<li>Measures both AC and DC voltages with digital multimeters that have a 10 MΩ input impedance (similar to the FLUKE 80K-40)</li>
<li>Is typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.</li>
<li>Intended for low energy applications only.</li>
<li>Lightweight and rugged. 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.</li>
</ul>
<p><span style="color: #ff0000;">Authorised Australian Distributor</span></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-PD-28.pdf" rel="noopener"><span style="font-size: 110%;">SEW-PD-28 Datasheet</span></a></h4>
<p>The post <a href="https://obiat.com.au/product/sew-pd-28-high-voltage-probe-40kvdc-28kvac/">SEW PD-28 HIGH VOLTAGE PROBE 40kVDC-28kVAC</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><span style="color: #000080; font-size: 110%;">SEW PD-28 High Voltage Probe (40kV DC or 28kV AC)</span></h4>
<p>The SEW PD-28 high voltage probe is designed to extend the voltage measuring capability of an AC/DC voltmeters to 40,000 volts peak AC or DC Overvoltage Category I. This means the probe can only be used to make measurements on energy limited circuits within equipment. Examples include high voltage within televisions or photo copy machines. <span style="font-size: 105%; color: #ff0000;"><strong>DO NOT</strong> </span>use this probe to measure high voltages on power distribution systems. The probe stated accuracy is when used with a voltmeter having 10 Megohm input impedance.</p>
<p>The probe is a precision 1000:1 voltage divider that is formed by two matched resistors. The unusually high input impedance offered by these resistors minimizes circuit loading and optimises measurement accuracy. A special plastic body houses the divider and provides the user with isolation and protection from the voltage being measured</p>
<ul>
<li>Measures both AC and DC voltages with digital multimeters that have a 10 MΩ input impedance.</li>
<li>Is typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.</li>
<li>Intended for low energy applications only.</li>
<li>Lightweight and rugged. 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.</li>
</ul>
<h4><span style="font-size: 110%;">SEW PD-28 HIGH VOLTAGE PROBE SPECIFICATIONS:</span></h4>
<table border="0" cellspacing="1" cellpadding="1">
<tbody>
<tr>
<td>Input impedance</td>
<td>1000 MΩ</td>
</tr>
<tr>
<td>Attenuation ratio</td>
<td>1000 : 1</td>
</tr>
<tr>
<td>Accuracy</td>
<td>DCV (0 ~ 20kV) ± 1%,<br />
DCV (20kV ~ 40kV) ± 2%,<br />
ACV (0 ~ 28kV) typically ± 5% at 50/60 Hz</td>
</tr>
<tr>
<td>Max. working voltage</td>
<td>40kV DC or 28kV AC</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>0°C ~ 40°C</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>-10°C ~ 50°C</td>
</tr>
<tr>
<td>Cable length</td>
<td>1 m</td>
</tr>
<tr>
<td>Weight</td>
<td>Approx. 260g</td>
</tr>
<tr>
<td>Safety standards</td>
<td>EN 61010-1, EN 61010-031, EN 61326-1</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-pd-28-high-voltage-probe-40kvdc-28kvac/">SEW PD-28 HIGH VOLTAGE PROBE 40kVDC-28kVAC</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 7015IN 15kV Digital High Voltage Insulation Tester</title>
		<link>https://obiat.com.au/product/sew-7015in-15kv-digital-high-voltage-insulation-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 07:49:28 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8813</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>The SEW 7015N Digital Cat IV (600 V) High Voltage Tester has thirty insulation test voltage levels ranging from 500 Volts to 15,000 Volts DC.</p>
<p>The SEW 7015IN suited for testing LV and MV electrical assets including high voltage motors. Insulation resistance can be measured to 2000 G-ohms, and other standard insulation tests include Dielectric Absorption Ratio (DAR) and Polarization Index (PI).</p>
<p><strong>Authorised Australian Distributor</strong></p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-7015N.pdf">SEW 7015N Datasheet</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/sew-7015in-15kv-digital-high-voltage-insulation-tester/">SEW 7015IN 15kV Digital High Voltage Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>SEW 7015IN 15kV Digital High Voltage Insulation Tester is provided with a guard rail to eliminate surface leakage when testing insulation resistance of assets such as PILC cables. Internal data storage can hold 200 measurements, and the instrument’s optical USB to RS-232 transmission<br />
port allows data export to PCs via SEW’s standard CD-supplied software.</p>
<p>Standard features of the SEW 7015IN 15kV Digital High Voltage Insulation Tester include an AC/DC voltmeter as well as audible alarm for live circuits, auto ranging on all insulation resistance ranges with auto hold to freeze readings, bar graph display allowing visual observation of charging patterns, overload protection, calendar and auto-power off.</p>
<p><span style="color: #ff0000;"><strong>SEW 7015IN Features:</strong></span></p>
<p>● Test Insulation Resistance up to 2 TΩ (2000GΩ).<br />
● Short-circuit current up to 5mA.<br />
● Microprocessor controlled.<br />
● 30 insulation test voltages :<br />
500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,<br />
3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV,<br />
6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV,<br />
9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV,<br />
12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV<br />
● AC/DC Voltmeter.<br />
● PI (Polarization Index) indication.<br />
● DAR (Dielectric Absorption ratio) indication.<br />
● Auto-ranging on all insulation ranges.<br />
● Backlight function.<br />
● Bargraph indicates test voltage, rise and decay<br />
can be observed.<br />
● Menu driven.<br />
● Visual and audible warning if external voltage is<br />
present. (≥30Vac or ≥30Vdc).<br />
● Auto-hold function to freeze the reading.<br />
● Overload protection.<br />
● Adjustment for testing time (duration) : 1~30 minutes.<br />
● Auto-off.<br />
● Calendar.<br />
● Optical USB to RS-232 data transmission.<br />
● 200 measurement results can be saved in the<br />
memory and recalled on the display.<br />
● Safety standard: EN 61010-1   CAT IV 600V<br />
EN 61010-2-030<br />
EN 61326-1</p>
<h5><span style="color: #ff0000;"><strong>SEW 7015IN Specifications:</strong></span></h5>
<table border="0" width="506" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="xl66" width="196" height="53"><strong><span style="font-family: Arial;"> Test Voltage</span></strong></td>
<td class="xl67" width="310"><span style="font-family: Arial;"> From 500Vdc to 15kVdc<br />
Adjustable in 500V steps</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="33"><strong><span style="font-family: Arial;"> Preset buttons</span></strong></td>
<td class="xl73" width="310"><span style="font-family: Arial;"> 1kV, 5kV, 10kV, 15kV</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> Insulation resistance</span></strong></td>
<td class="xl73" width="310"><span style="font-family: Arial;"> 70GΩ/0.5kV<br />
70GΩ at 0.5kV~2TΩ at 15kV</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="33"><strong><span style="font-family: Arial;"> Accuracy</span></strong></td>
<td class="xl71" width="310"><span style="font-family: Arial;"> ±(5.0%rdg+5dgt) </span></td>
</tr>
<tr>
<td class="xl70" width="196" height="106"><strong><span style="font-family: Arial;"> Resolution</span></strong></td>
<td class="xl71" width="310"><span style="font-family: Arial;"> 2GΩ : 0.001GΩ<br />
20GΩ : 0.01GΩ<br />
200GΩ : 0.1GΩ<br />
2TΩ : 1GΩ</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="40"><strong><span style="font-family: Arial;"> Short circuit current</span></strong></td>
<td class="xl71" width="310"><span style="font-family: Arial;"> up to 5mA</span></td>
</tr>
<tr>
<td class="xl68" height="33"><strong><span style="font-family: Arial;"> PI (Polarization Index)</span></strong></td>
<td class="xl71" width="310"><span style="font-family: Arial;"> V</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> DAR (Dielectric  </span></strong><strong><span style="font-family: Arial;">  Absorption Ratio)</span></strong></td>
<td class="xl72"><span style="font-family: Arial;"> V</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="106"><strong><span style="font-family: Arial;"> Voltmeter</span></strong></td>
<td class="xl73" width="310"><span style="font-family: Arial;"> ACV : 0~600V (50/60Hz)<br />
DCV : 0~600V<br />
Accuracy : ±(2.0%rdg+3dgt)<br />
Resolution : 1V</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> Power source</span></strong></td>
<td class="xl72"><span style="font-family: Arial;"> Rechargeable battery</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> AC Adapter</span></strong></td>
<td class="xl73" width="310"><span style="font-family: Arial;"> Input : 100-240V~ ,0.4A ,50-60Hz<br />
Output : 24V &#8230; 0.62A</span></td>
</tr>
<tr>
<td class="xl70" width="196" height="53"><strong><span style="font-family: Arial;"> Dimensions</span></strong></td>
<td class="xl72"><span style="font-family: Arial;"> 430(L) x 324(W) x 127(D)mm</span></td>
</tr>
<tr>
<td class="xl74" width="196" height="40"><strong><span style="font-family: Arial;"> Weight</span></strong></td>
<td class="xl69"><span style="font-family: Arial;"> Approx : 5kg</span></td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-7015in-15kv-digital-high-voltage-insulation-tester/">SEW 7015IN 15kV Digital High Voltage Insulation Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 8020ER Earth Resistance Tester</title>
		<link>https://obiat.com.au/product/sew-8020er-earth-resistance-tester/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 07:20:47 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8809</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<h3>SEW 8020ER Earth Resistance Tester Features:</h3>
<ul>
<li>Capable of measuring earth resistance and earth voltage</li>
<li>2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test</li>
<li>Frequency: 820Hz; 0Ω adjustment function</li>
<li>Battery operated. Data hold function</li>
<li>Low battery indication. Calibration performed with supplied test leads</li>
<li>Simplified measurement probe is also provided for two-wire measuring method</li>
</ul>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a target="_blank" href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-8020-ER-Datasheet.pdf" rel="noopener">SEW-8020-ER-Datasheet</a></span></h4>
<p>The post <a href="https://obiat.com.au/product/sew-8020er-earth-resistance-tester/">SEW 8020ER Earth Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The SEW 8020ER Earth Resistance Tester is a handheld device which allows fast and easy determination of the earth resistance. The grounding resistance is determined with this earth tester in three measuring ranges up to 2000 Ω using three-wire technology also simplified measurement probe is also provided for two-wire measuring method.</p>
<h4><strong>SEW 8020ER Earth Resistance Tester Specifications:</strong></h4>
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td rowspan="2" width="50%">Measuring ranges</td>
<td width="50%">Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω</td>
</tr>
<tr>
<td>Earth voltage 0-200 Vac (40-500Hz)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>Earth resistance ±(1.5%rdg+2dgt) or ±0.1Ω, which is greater<br />
Earth voltage ±(1%rdg+2dgt)</td>
</tr>
<tr>
<td>Earth resistance resolution</td>
<td>0-20Ω : 0.01Ω<br />
0-200Ω : 0.1Ω<br />
0-2000Ω : 1Ω</td>
</tr>
<tr>
<td>Testing frequency</td>
<td>820 Hz</td>
</tr>
<tr>
<td>Measuring system</td>
<td>Earth resistance by constant current inverter 820Hz approx 2mA.</td>
</tr>
<tr>
<td>Display</td>
<td>3½ digit (2000 counts)</td>
</tr>
<tr>
<td>0Ω adjustment function</td>
<td>Yes</td>
</tr>
<tr>
<td>Open circuit indication</td>
<td>LED will be unlit</td>
</tr>
<tr>
<td>Low battery indication</td>
<td>Yes</td>
</tr>
<tr>
<td>Data hold indication</td>
<td>Yes</td>
</tr>
<tr>
<td>Over range Indication</td>
<td>“1”(MSD)</td>
</tr>
<tr>
<td>Dimensions</td>
<td>221(L) x 110(W) x 57(D)mm</td>
</tr>
<tr>
<td>Weight (battery included)</td>
<td>Approx. 600g</td>
</tr>
<tr>
<td>Power source</td>
<td>1.5V (AA) × 6</td>
</tr>
<tr>
<td>Safety standard</td>
<td>IEC/EN 61010-1 CAT IV 200V<br />
EN 61557-1 EN 61557-5<br />
EN 61326-1</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-8020er-earth-resistance-tester/">SEW 8020ER Earth Resistance Tester</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW ITC8 Insulation Resistance Tester Check Box</title>
		<link>https://obiat.com.au/product/sew-itc8-insulation-resistance-tester-check-box/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sat, 19 May 2018 06:18:17 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8806</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>SEW ITC8 Insulation Resistance Tester Check Box is used to check the resistance reading of insulation tester or any test instrument which uses resistance as part of it's measurement capability i.e. multimeters, clampmeters etc;</p>
<div id="yt_tab_products" class="tab-product-detail">
<div class="yt-tab-content tab-content">
<div id="yt_tab_decription" class="tab-pane fade in active">
<div class="std">
<h4>Features:</h4>
<ul>
<li>Portable and lightweight</li>
<li>Resistance Settings: 0.5Ω, 1Ω, 2Ω, 20Ω, 200Ω, 1kΩ, 10kΩ, 20kΩ, 100kΩ, 1MΩ, 2MΩ, 10MΩ</li>
<li>Maximum Voltage Input: 1000V DC</li>
<li>Can be used to check any meter using resistance ranges and standard probes</li>
<li>Quick and easy to use</li>
</ul>
</div>
</div>
</div>
</div>
<div class="category-products sm-slider related"> <span style="color: #ff0000;"><strong>Authorised Australian Distributor</strong></span></div>
<p>The post <a href="https://obiat.com.au/product/sew-itc8-insulation-resistance-tester-check-box/">SEW ITC8 Insulation Resistance Tester Check Box</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>SEW ITC8 Insulation Resistance Tester Check Box has a range of user selectable resistances chosen by it&#8217;s rotary dial. The insulation tester connected to it and the resistance reading on the screen is compared to the known resistance on the SEW ITC8. This gives an indication of the accuracy of the instrument and if there is a need to re-calibrate.</p>
<p>This SEW ITC8 Insulation Resistance Tester Check Box with it&#8217;s 12 resistance settings ranging from 0.5 Ohms to 10MOhms allows the user to regularly verify that their instrument are accurate (within the tolerance of theSEW ITC8).</p>
<p>The SEW ITC8 Insulation Resistance Tester Check Box is useful not only on the test bench but also in the field.</p>
<h4><strong>SEW ITC8 Insulation Resistance Tester Check Box Features:</strong></h4>
<ul>
<li>A range of user selectable resistances from 500 milliohms to 10 megohms</li>
<li>Portable and lightweight</li>
<li>Suitable for use on the bench and in the field</li>
<li>Gives the user confidence in meter accuracy</li>
<li>Quick and easy to use</li>
<li>Input voltage up to 1000VDC</li>
</ul>
<h4><strong>SEW ITC8 Insulation Resistance Tester Check Box S</strong><strong>pecifications:</strong></h4>
<ul>
<li>Resistance Settings: 0.5Ω, 1Ω, 2Ω, 20Ω, 200Ω, 1kΩ, 10kΩ, 20kΩ, 100kΩ, 1MΩ, 2MΩ, 10MΩ</li>
<li>Accuracy: 0.5Ω &#8211; 2Ω ± 0.05Ω,<br />
20Ω &#8211; 10Ω ± 2%</li>
<li>Maximum Voltage Input: 1000V DC</li>
<li>Case: Impact Resistant ABS</li>
</ul>
<p>The post <a href="https://obiat.com.au/product/sew-itc8-insulation-resistance-tester-check-box/">SEW ITC8 Insulation Resistance Tester Check Box</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 5500CB Cable Locator</title>
		<link>https://obiat.com.au/product/sew-5500cb-cable-locator/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 18 May 2018 02:46:13 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8800</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>The SEW 5500CB is a professional general purpose cable locator. It is ideal for tracing cables in walls and underground and for locating fuses &#38; breakers on their circuits.</p>
<p>The SEW 5500CB can also locate interruptions and short-circuits in cables and electrical floor heating systems. It can also be used for tracing metal water and heating pipes.</p>
<p>The unit is supplied as a complete kit comprising of a transmitter and receiver in a  carry case. The Transmitter &#38; the Receiver both also have an inbuilt torch for working in poorly lit locations.</p>
<p><strong>SEW 5500CB Features:</strong></p>
<ul>
<li><span class="notranslate">Can be used on cables without voltage or voltage</span></li>
<li><span class="notranslate">Set includes transmitter and receiver</span></li>
<li><span class="notranslate">Set allows locating fuses, short circuits and cord interruptions, searching for metal installations in the wall and ground, ...</span></li>
<li><span class="notranslate">Digital encoded transmitter signal</span></li>
<li><span class="notranslate">Signal detection;</span> <span class="notranslate">Automatic mode or manual mode (9 levels of choice)</span></li>
<li><span class="notranslate">Receiver with LCD display and level display of received signal, transmitted transmitter code and external voltage</span></li>
<li><span class="notranslate">Transmitter with the option of setting the triplets of the transmitted signal</span></li>
<li><span class="notranslate">The choice of the signal code on the transmitter.</span></li>
<li><span class="notranslate">Measurement of the AC / DC voltage on the receiver from 12 to 300 V</span></li>
<li><span class="notranslate">Built-in light in the transmitter and receiver for illumination of the workplace</span></li>
<li><span class="notranslate">Automatic switch off the instrument</span></li>
</ul>
<p><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <a href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-5500CB-Datasheet.pdf">SEW-5500CB-Datasheet</a></p>
<p>The post <a href="https://obiat.com.au/product/sew-5500cb-cable-locator/">SEW 5500CB Cable Locator</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The SEW 5500CB is a very versatile general purpose cable locator that is ideal for tracing cables in walls and underground and for locating fuses &amp; breakers at the switchboard for these cables.</p>
<p><span style="font-size: large; color: #ff0000;"><strong>SEW 5500CB Transmitter Features:</strong></span><u><span style="font-size: large;"><br />
</span></u>● The SEW 5500CB transmitter is the ideal tool for locating and identifying cables and individual conductors.<br />
● Designed for locating unenergized cables and powered cables.<br />
● Voltage measurement for cables :<br />
ACV 12V~300V<br />
DCV 12V~300V<br />
● Signal Transmission<br />
●Transmission Power Level Selection (includes 1, 2, 3)<br />
● Transmission Signal Code Selection (includes F, E, H, d, L, C, O, A)<br />
● Flashlight &amp; Back Light function.<br />
● The Silent Mode (Disable Button Beep).<br />
● The Level Bar Display on the LCD Screen (the transmission power level indication).<br />
● The Action Wave Display on the LCD Screen (when the signal is transmitted).<br />
● Auto power off function.</p>
<p><strong><span style="font-size: 110%; color: #ff0000;">SEW 5500CB Receiver Features:</span><u><span style="font-size: large;"><br />
</span></u></strong>● The SEW 5500CB receiver is designed to identify and trace wires or cables.<br />
● Designed for locating unenergized cables and powered cables.<br />
● Signal Detection (includes Level, Code, Value)<br />
● Automatic Mode<br />
● Manual Mode (There are 9 levels to select).<br />
● UAC Mode (AC Power Line Detection)<br />
● Flashlight &amp; Back Light function.<br />
● The Silent Mode (Disable Button Beep &amp; Frequency Tone)<br />
● The Danger Symbol is to indicate the AC voltage on the Line.<br />
● The Level Bar Display on the LCD Screen for the signal value &amp; the UAC power value.<br />
● Auto power off function.</p>
<h4><strong><span style="color: #ff0000; font-size: 110%;">SEW5500CB SPECIFICATIONS:</span></strong></h4>
<table width="651">
<tbody>
<tr>
<td width="396">
<h4><strong> Transmitter</strong></h4>
</td>
<td width="64"></td>
<td width="191"></td>
</tr>
<tr>
<td width="396">  Output signal frequency</td>
<td colspan="2" width="255"> 125kHz</td>
</tr>
<tr>
<td width="396">  Voltage measurement range</td>
<td colspan="2" width="255"> 12~300V AC / DC</td>
</tr>
<tr>
<td width="396">  Accuracy</td>
<td colspan="2" width="255">±(2%rdg+2dgt)</td>
</tr>
<tr>
<td width="396">  Display</td>
<td colspan="2" width="255"> LCD shows function and bargraph</td>
</tr>
<tr>
<td width="396">  Power source</td>
<td colspan="2" width="255"> 1.5V (AAA) battery × 6</td>
</tr>
<tr>
<td width="396">  Fuse</td>
<td colspan="2" width="255"> 690V/0.5A (6.3 × 32mm)</td>
</tr>
<tr>
<td width="396">  Operating temperature</td>
<td colspan="2" width="255"> 0°C~40°C</td>
</tr>
<tr>
<td width="396">  &amp; humidity</td>
<td colspan="2" width="255">80% R.H. Max.</td>
</tr>
<tr>
<td width="396">  Storage temperature</td>
<td colspan="2" width="255"> -10°C~50°C</td>
</tr>
<tr>
<td width="396">  &amp; humidity</td>
<td colspan="2" width="255">80% R.H. Max.</td>
</tr>
<tr>
<td width="396">  Dimensions</td>
<td colspan="2" width="255"> 188(L)×90(W)×47(D)mm</td>
</tr>
<tr>
<td width="396">  Weight</td>
<td colspan="2" rowspan="2" width="255"> Approx. 389g</td>
</tr>
<tr>
<td width="396">  (battery Included)</td>
</tr>
<tr>
<td width="396"></td>
<td width="64"></td>
<td width="191"></td>
</tr>
<tr>
<td width="396">
<h4><strong> Receiver</strong></h4>
</td>
<td width="64"></td>
<td width="191"></td>
</tr>
<tr>
<td width="396"> Detection depth</td>
<td colspan="2" width="255"> &lt; 50cm</td>
</tr>
<tr>
<td width="396"> Display</td>
<td colspan="2" width="255"> LCD shows function and bargraph</td>
</tr>
<tr>
<td width="396"> Power source</td>
<td colspan="2" width="255"> 1.5V (AAA) battery × 6</td>
</tr>
<tr>
<td width="396"> Operating temperature</td>
<td colspan="2" width="255"> 0°C~40°C</td>
</tr>
<tr>
<td width="396"> &amp; humidity</td>
<td colspan="2" width="255">80% R.H. Max.</td>
</tr>
<tr>
<td width="396"> Storage temperature</td>
<td colspan="2" width="255"> -10°C~50°C</td>
</tr>
<tr>
<td width="396"> &amp; humidity</td>
<td colspan="2" width="255">80% R.H. Max.</td>
</tr>
<tr>
<td width="396"> Dimensions</td>
<td colspan="2" width="255"> 247(L)×78(W)×45(D)mm</td>
</tr>
<tr>
<td width="396"> Weight (battery included)</td>
<td colspan="2" width="255"> Approx. 324g</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/sew-5500cb-cable-locator/">SEW 5500CB Cable Locator</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SEW 6280TB Professional Instrument Calibration Check Box</title>
		<link>https://obiat.com.au/product/sew-6280tb-professional-instrument-calibration-check-box/</link>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Fri, 18 May 2018 02:28:07 +0000</pubDate>
				<guid isPermaLink="false">https://obiat.com.au/?post_type=product&#038;p=8796</guid>

					<description><![CDATA[<p><a href="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg"><img class="alignnone size-full wp-image-4126" src="https://obiat.com.au/wp-content/uploads/2017/09/SEW-Logo.jpg" alt="" width="120" height="70" /></a></p>
<p>The SEW 6280TB is designed for field or workshop use and can test a wide range of instrumentation.  The control panel on the SEW 6280TB is divided into three sections with each function having its own section.</p>
<p>To operate the test box, the user simply plugs the power cable of the SEW 6280TB into a standard power outlet and plugs the instrument to be tested into the SEW 6280TB.</p>
<p>The image shows a "multifunction" power socket on the instrument but all instruments delivered in Australia will be fitted with the correct 3 pin Australian socket.</p>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-6280TB-Datasheet.pdf">SEW-6280TB-Datasheet</a></span></h4>
<h4><a href="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg"><img class="alignnone size-full wp-image-3188" src="https://obiat.com.au/wp-content/uploads/2016/05/PDF-Logo.jpg" alt="" width="58" height="58" /></a>    <span style="font-size: 110%;"><a href="https://obiat.com.au/wp-content/uploads/2018/05/SEW-6280-TB-Application-Note.pdf">SEW-6280-TB-Application-Note</a></span></h4>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/sew-6280tb-professional-instrument-calibration-check-box/">SEW 6280TB Professional Instrument Calibration Check Box</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The SEW 6280TB Calibration Test Box is used for checking the integrity and calibration of insulation resistance testers, loop impedance testers and RCD testers, as well as multifunction electrical testers, which may have all three functions in one instrument. The SEW 6280 TB comes in a hard case for protection in the field.</p>
<p>For RCD tester verification, the SEW 6280 TB can simulate a 10mA, 30mA and 150mA RCD with trip times of 150ms or 30ms (in the case of a 150mA simulation). Loop impedance is checked by plugging the meter being tested into the loop tester section of the test box and operating the meter being tested. The bi-directional switch on the SEW 6280TB allows the operator to measure the local supply loop, and then by changing the switch the test box can simulate a loop impedance value (supply loop + 1 Ohm) to verify the accuracy of the loop impedance tester being checked. Finally the SEW 6280TB can check insulation resistance testers, in both insulation resistance mode as well as continuity mode with a number of pre-set values and test voltages.</p>
<h3><span style="color: #ff0000;"><strong>SEW 6280TB Check Box Features:</strong></span></h3>
<ul>
<li>Wide range of operating voltages from AC 210V/50Hz to 250V/50Hz</li>
<li>Calibration check of: RCD Testers, Loop Testers and Insulation Testers</li>
<li>Simulate 3 RCD Test currents and Trip times</li>
<li>Wiring checks: Phase, Neutral, Earth</li>
<li>Fuse protected</li>
<li>Supplied with test leads and plugs</li>
<li>Plugs into main supply outlets for power</li>
</ul>
<table border="0" summary="My Summary" width="100%" cellspacing="1" cellpadding="1" align="left">
<tbody>
<tr>
<td>
<table border="1" width="428" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="100%">
<table border="0" width="748" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td bgcolor="#ff0000" height="28"><span style="color: #ffffff; font-family: 微軟正黑體; font-size: medium;"><strong> SEW 6280TB FEATURES:</strong></span></td>
</tr>
<tr>
<td><span style="font-size: medium;">● For checking AC voltage.<br />
● For checking a RCD tester&#8217;s test current &amp; time in mA(ms).<br />
● For checking a loop tester.<br />
● For wiring check (Phase, Neutral, Earth).<br />
● For checking continuity.<br />
● For checking insulation (The maximum is 1.2kV).<br />
● For checking UK16th edition.<br />
</span></td>
</tr>
<tr>
<td height="30"></td>
</tr>
<tr>
<td bgcolor="#ff0000" height="28"><span style="color: #ffffff; font-family: 微軟正黑體; font-size: medium;"><strong>  SEW 6280TB SPECIFICATIONS:</strong></span></td>
</tr>
<tr>
<td>
<table border="1" width="428" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="100%">
<table border="0" width="748" cellspacing="0" cellpadding="0">
<colgroup>
<col width="205" />
<col span="3" width="181" /></colgroup>
<tbody>
<tr>
<td class="xl26" width="205" height="33"><span style="font-size: large;"><strong><span style="font-family: Arial;">  RCD Testing</span></strong></span></td>
<td class="xl24" width="181"></td>
<td class="xl24" width="181"></td>
<td class="xl24" width="181"></td>
</tr>
<tr>
<td class="xl32" width="205" height="80"><strong><span style="font-family: Arial;">  Range</span></strong></td>
<td class="xl45" colspan="3" width="543"><span style="font-family: Arial;">  10mA @ 150ms<br />
30mA @ 150ms<br />
150mA @ 30ms</span></td>
</tr>
<tr>
<td class="xl30" width="205" height="53"><strong><span style="font-size: large;"><span style="font-family: Arial;">  Insulation Testing</span></span></strong></td>
<td class="xl42" colspan="3" width="543"><span style="font-family: Arial;">　</span></td>
</tr>
<tr>
<td class="xl29" width="205" height="53"><strong><span style="font-family: Arial;">  Range</span></strong></td>
<td class="xl39" colspan="3" width="543"><span style="font-family: Arial;">  1M</span><span class="font7" style="font-family: 標楷體;">Ω</span><span class="font6" style="font-family: Arial;"> / 9.9M</span><span class="font7" style="font-family: 標楷體;">Ω</span><span class="font6" style="font-family: Arial;"> / 99M</span><span class="font7" style="font-family: 標楷體;">Ω</span></td>
</tr>
<tr>
<td class="xl29" width="205" height="53"><strong><span style="font-family: Arial;">  Accuracy</span></strong></td>
<td class="xl34" colspan="3" width="543"><span style="font-family: Arial;"> ± 1%</span></td>
</tr>
<tr>
<td class="xl27" width="205" height="53"><strong><span style="font-family: Arial;">  Max. Testing</span></strong></td>
<td class="xl33" colspan="3" width="543"><span style="font-family: Arial;">  1.2kV</span></td>
</tr>
<tr>
<td class="xl26" height="53"><span style="font-size: large;"><strong><span style="font-family: Arial;">  Continuity Testing</span></strong></span></td>
<td class="xl24"></td>
<td class="xl24"></td>
<td class="xl24"></td>
</tr>
<tr>
<td class="xl28" width="205" height="53"><strong><span style="font-family: Arial;">  Range</span></strong></td>
<td class="xl37" colspan="3" width="543"><span style="font-family: Arial;">  0.5Ω / 2Ω / 10Ω</span></td>
</tr>
<tr>
<td class="xl29" width="205" height="53"><strong><span style="font-family: Arial;">  Accuracy</span></strong></td>
<td class="xl34" colspan="3" width="543"><span style="font-family: Arial;">  ± 0.05Ω / ± 0.1Ω / ± 0.2Ω</span></td>
</tr>
<tr>
<td class="xl27" width="205" height="53"><strong><span style="font-family: Arial;">  Max. Current</span></strong></td>
<td class="xl33" colspan="3" width="543"><span style="font-family: Arial;">  300mA</span></td>
</tr>
<tr>
<td class="xl26" height="53"><span style="font-size: large;"><strong><span style="font-family: Arial;">  LOOP Testing</span></strong></span></td>
<td class="xl24"></td>
<td class="xl24"></td>
<td class="xl24"></td>
</tr>
<tr>
<td class="xl28" width="205" height="53"><strong><span style="font-family: Arial;">  Range</span></strong></td>
<td class="xl37" colspan="3" width="543"><span style="font-family: Arial;"> Supply Loop / Supply Loop +1Ω</span></td>
</tr>
<tr>
<td class="xl27" width="205" height="53"><strong><span style="font-family: Arial;">  Accuracy</span></strong></td>
<td class="xl33" colspan="3" width="543"><span style="font-family: Arial;">  0.45Ω ± 0.05Ω / 1.45Ω ± 0.05Ω</span></td>
</tr>
<tr>
<td class="xl25" colspan="2" height="53"><strong><span style="font-family: Arial;">• Dimension: 330(L)x260(W)x160(D)mm</span></strong></td>
<td class="xl24"></td>
<td class="xl24"></td>
</tr>
<tr>
<td class="xl25" height="53"><strong><span style="font-family: Arial;">• Weight: Approx. 2570g</span></strong></td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/sew-6280tb-professional-instrument-calibration-check-box/">SEW 6280TB Professional Instrument Calibration Check Box</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
