<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Thermometer Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-tag/thermometer/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-tag/thermometer/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Tue, 16 Aug 2022 00:10:45 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Thermometer Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-tag/thermometer/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Extech SDL200 4-Channel Thermometer Datalogger</title>
		<link>https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/</link>
					<comments>https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Sun, 24 Apr 2016 11:02:23 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=3002</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1918" src="http://obiat.com.au/wp-content/uploads/2016/03/Extech-logo.jpg" alt="Extech logo" width="200" height="61" /></p>
<p>Four-channel data logging thermometer accepts both thermocouple and RTD probes. Data is recorded onto a standard SD memory card, instead of a built-in memory; the advantage being that when the memory is full the SD card can be simply changed out for unlimited data storage.</p>
<p>The removable SD card is easy to transport and insert into a computer’s memory card slot or SD card reader for upload. The data is provided in Excel, allowing you to easily analyze the information without the need for additional software. Data can also be streamed directly to a computer using the RS-232 port on the meter.</p>
<ul>
<li class="deck"><span class="blacktext">Records data onto an SD card in Excel® format for easy transfer to a PC for analysis</span></li>
</ul>
<ul>
<li class="bullet"><span class="blacktext">Data logging capability up to 20,000 records using a 2G SD card</span></li>
</ul>
<ul>
<li class="bullet"><span class="blacktext">User programmable sampling rate from 1 to 3600 seconds</span></li>
</ul>
<ul>
<li class="bullet"><span class="blacktext">Manual store and recall of up to 99 records</span></li>
</ul>
<ul>
<li class="bullet"><span class="blacktext">Records readings with real-time/date stamp</span></li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/04/SDL200_UM.pdf" target="_blank" rel="">Extech SDL200 User Manual</a></p>
<p>The post <a href="https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/">Extech SDL200 4-Channel Thermometer Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Extech SDL200 4-Channel Thermometer SD Logger</h4>
<p>The Extech SDL200 displays and stores temperature readings from up to four (4) Type K, J, T, E, R, or S thermocouple temperature probes and two (2) Pt100 RTD probes. Logged data readings are stored on an SD card for transfer to a PC. In addition, an RS232 port allows data streaming to a PC. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service.</p>
<h4>Extech SDL200 Features:</h4>
<ul>
<li>4-Channel datalogging with 6 Thermocouple types (J, K, E, T, R,S) and 2-Channel datalogging with RTD (Pt100Ω) probes</li>
<li>Displays [T1, T2, T3, T4] or differential [T1-T2] reading</li>
<li>Offset adjustment used for zero function to make relative measurements</li>
<li>Stores 99 readings manually and 20M readings via 2G SD card</li>
<li>Records readings with real date and time stamp</li>
<li>User programmable sampling rate: 1 to 3600 seconds</li>
<li>Min/Max and Data Hold functions</li>
<li>Auto power off with disable function</li>
<li>Built-in PC interface</li>
<li>Complete with 6 AA batteries, four general purpose Type K bead wire temperature probes, SD card, and hard carrying case</li>
</ul>
<h3>Extech SDL200 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">General Specifications</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type J</td>
<td class="speccelldata" align="center">-148 to 2192°F (-100 to 1200°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type K</td>
<td class="speccelldata" align="center">-148 to 2372°F  (-100 to 1300°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type T</td>
<td class="speccelldata" align="center">-58 to 752°F   (-50 to 400°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type E</td>
<td class="speccelldata" align="center">-58 to 1652°F   (-50 to 900°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type R</td>
<td class="speccelldata" align="center">32 to 3092°F   (0 to 1700°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Type S</td>
<td class="speccelldata" align="center">32 to 2732°F   (0 to 1500°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">RTD (Pt100)</td>
<td class="speccelldata" align="center">-327 to 1562°F   (-200 to 850°C)</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Resolution</td>
<td class="speccelldata" align="center">0.1°/1°</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Basic Accuracy</td>
<td class="speccelldata" align="center">±0.4% rdg (+1.8°F/+1°C) Types J,K,E,T, Pt100 ±0.5% rdg (+2°F/+1°C) Types R,S</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Datalogging</td>
<td class="speccelldata" align="center">20M data records using a 2G SD card</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Dimensions</td>
<td class="speccelldata" align="center">182 x 73 x 47.5mm</td>
</tr>
<tr>
<td class="speccelltitle" valign="middle">Weight</td>
<td class="speccelldata" align="center">500g</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/">Extech SDL200 4-Channel Thermometer Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/extech-sdl200-4-channel-thermometer-datalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Extech EA15 Thermocouple Datalogging Thermometer</title>
		<link>https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/</link>
					<comments>https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 22 Mar 2016 21:12:34 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1985</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-1918" src="http://obiat.com.au/wp-content/uploads/2016/03/Extech-logo.jpg" alt="Extech logo" width="200" height="61" /></p>
<ul class="featurestext">
<li><strong>Dual input accepts Types J, K, E, T, R, S, and N thermocouples</strong></li>
<li><strong>Built-in datalogger stores up to 8800 data sets</strong></li>
<li><strong>RS-232 port to transfer data to PC for analysis</strong></li>
<li><strong>Real Time Clock</strong></li>
<li><strong>Includes Windows® 95/98/NT/2000/ME/XP compatible software and cable</strong></li>
<li>Compact and rugged design features large backlit display</li>
<li>Displays [T1 plus T2] or [T1-T2 plus T1] or [T1-T2 plus T2]</li>
<li>Selectable units of °F, °C, K (Kelvin)</li>
<li>Wide temperature range with 0.1°/1° resolution</li>
<li>Timer function displays elapsed time plus the time when MIN and MAX readings are taken</li>
<li>OFFSET key used for zero function to make relative measurements</li>
<li>Data Hold function freezes reading on display</li>
<li>Auto Power off to save battery life</li>
<li>Low battery and overrange indication</li>
<li>Records Max/Min readings for later recall</li>
<li>Complete with built-in stand, protective holster, two Type K bead wire temperature probes (-20 to 250°C), and 6 AAA batteries</li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/03/EA15_UM.pdf" target="_blank" rel="">Extech EA15 User Manual</a></p>
<h4>Authorised Australian Distributor</h4>
<p><img class="alignnone size-full wp-image-2451" src="http://obiat.com.au/wp-content/uploads/2016/04/Capture-2.jpg" alt="CE" width="37" height="30" />   <img class="alignnone size-full wp-image-2450" src="http://obiat.com.au/wp-content/uploads/2016/04/1-Year.jpg" alt="1 Year" width="67" height="35" /></p>
<p>The post <a href="https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/">Extech EA15 Thermocouple Datalogging Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Extech EA15 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2">Measurement Ranges</td>
</tr>
<tr>
<td class="speccelltitle" width="250"> K &#8211; Type</td>
<td class="speccelldata">-150.0°C to +1370.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J &#8211; Type</td>
<td class="speccelldata">-150.0°C to +1090.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">T &#8211; Type</td>
<td class="speccelldata">-150.0°C to +400.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">E &#8211; Type</td>
<td class="speccelldata">-150.0°C to +870.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">R &#8211; Type</td>
<td class="speccelldata">0.0°C to +1767.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">S &#8211; Type</td>
<td class="speccelldata">0.0°C to +1767.0°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">N &#8211; Type</td>
<td class="speccelldata">-150.0°C to +1300.0°C</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Resolution</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J, K, T, E, N &#8211; Type</td>
<td class="speccelldata">0.1°F/°C/K</td>
</tr>
<tr>
<td class="speccelltitle" width="250">R, S &#8211; Type</td>
<td class="speccelldata">1.0°F/°C/K (0.1° for reference only)</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Accuracy</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J, K, T, E, N &#8211; Type</td>
<td class="speccelldata">±(0.05% reading + 1.5°F(0.75°C)) below -148°F (-100°C)</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J, K, E, N &#8211; Type</td>
<td class="speccelldata">add ±0.15%</td>
</tr>
<tr>
<td class="speccelltitle" width="250">T &#8211; Type</td>
<td class="speccelldata">add ±0.45%</td>
</tr>
<tr>
<td class="speccelltitle" width="250">R, S &#8211; Type</td>
<td class="speccelldata">add ±(0.05 of reading +2°F(1°C))</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">Temperature Coefficient</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Outside the specified range<br />
+18°C to 28°C</td>
<td class="speccelldata">±(0.01% of reading +0.06°F per °F (+0.03 °C))</td>
</tr>
<tr>
<td class="speccelldata" colspan="2" align="center">Below -100°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">J, K, E, N &#8211; Type</td>
<td class="speccelldata">0.04% of reading</td>
</tr>
<tr>
<td class="speccelltitle" width="250">T &#8211; Type</td>
<td class="speccelldata">0.08% of reading</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2">General</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Display</td>
<td class="speccelldata">Dual Display Multi-function LCD with Backlight</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Input Protection</td>
<td class="speccelldata">60VDC, 24VAC rms</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Measurement Rate</td>
<td class="speccelldata">1 time per 1.5 second</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Over range indication</td>
<td class="speccelldata">&#8220;OL&#8221; appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Open input indication</td>
<td class="speccelldata">&#8220;OL&#8221; appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Low battery indication</td>
<td class="speccelldata">“BT” appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Manual Memory Capacity</td>
<td class="speccelldata">98 sets</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Datalogging Memory Capacity</td>
<td class="speccelldata">8800 sets</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Power supply</td>
<td class="speccelldata">6 ‘AAA’ Batteries</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Battery life</td>
<td class="speccelldata">Approximately 200 hours with alkaline batteries</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Operating Temperature</td>
<td class="speccelldata">0 to 50°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Operating Humidity</td>
<td class="speccelldata">&lt; 80% RH</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Storage Temperature</td>
<td class="speccelldata">-10 to 60°C</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Storage Humidity</td>
<td class="speccelldata">10 to 80% RH</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Dimensions</td>
<td class="speccelldata">150 x 72 x 35mm</td>
</tr>
<tr>
<td class="speccelltitle" width="250">Weight Approx.</td>
<td class="speccelldata">235g with batteries</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/">Extech EA15 Thermocouple Datalogging Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/extech-ea15-thermocouple-datalogging-thermometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Extech EA10 Dual Input K Type Thermometer</title>
		<link>https://obiat.com.au/product/extech-ea10-easyview-type-k-dual-input-thermometer-dual-readings/</link>
					<comments>https://obiat.com.au/product/extech-ea10-easyview-type-k-dual-input-thermometer-dual-readings/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Tue, 22 Mar 2016 20:48:20 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=1983</guid>

					<description><![CDATA[<p><img src="http://obiat.com.au/wp-content/uploads/2016/03/Extech-logo.jpg" alt="Extech logo" width="200" height="61" /></p>
<h4>Extech EA10 Features:</h4>
<ul>
<li> Type K Dual input</li>
<li>Compact and rugged design features large backlit display</li>
<li>Displays [T1 plus T2] or [T1-T2 plus T1] or [T1-T2 plus T2]</li>
<li>Selectable units of °F, °C, K (Kelvin)</li>
<li>Wide temperature range with 0.1°/1° resolution</li>
<li>Timer function displays elapsed time plus the time when MIN and MAX readings are taken</li>
<li>OFFSET key used for zero function to make relative measurements</li>
<li>Data Hold function freezes reading on display</li>
<li>Auto Power off to save battery life</li>
<li>Low battery and overrange indication</li>
<li>Records Max/Min readings for later recall</li>
<li>Complete with built-in stand, protective holster, two Type K bead wire temperature probes (-20 to 250°C), and 6 AAA batteries</li>
</ul>
<h4>Authorised Australian Distributor</h4>
<p><img class="alignnone size-full wp-image-2451" src="http://obiat.com.au/wp-content/uploads/2016/04/Capture-2.jpg" alt="CE" width="37" height="30" />   <img class="alignnone size-full wp-image-2450" src="http://obiat.com.au/wp-content/uploads/2016/04/1-Year.jpg" alt="1 Year" width="67" height="35" /></p>
<p>The post <a href="https://obiat.com.au/product/extech-ea10-easyview-type-k-dual-input-thermometer-dual-readings/">Extech EA10 Dual Input K Type Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Extech EA10</h3>
<p>This device offers dual thermocouple inputs with multifunction LCD display. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service</p>
<p><strong>MIN, MAX, AVG Recording Function with Timer </strong></p>
<p>Press the MX/MN button to begin capturing the Minimum (MN), Maximum (MX), and Average (AVG) temperature values. The Elapsed Time clock will appear on the lower left of the display and the lower display will indicate the MAXIMUM (MX) value captured since the MX/MN button was pressed. Press the MX/MN button to change the lower display to reflect the stored MX to MN and then AVG value of the input selected in the upper display (T1, T2 or T1‐T2). Each reading will be accompanied by a Timer value indicating the time when each reading was recorded. Press the Time button to change the elapsed time format from min:sec to hour:min. Press and Hold the MX/MN button until the display returns to standard operation to exit the MX/MN function.</p>
<p><strong>Data Hold </strong></p>
<p>Press the HOLD button to freeze the reading in the display. The &#8216;H&#8217; hold icon will appear on the upper left‐hand side of the display. Press the HOLD button again to return to normal operation (the &#8216;H&#8217; hold icon will disappear).</p>
<h3>Extech EA10 Specifications:</h3>
<div id="tab-specifications" class="tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom ui-tabs-hide">
<table class="spectable" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td class="speccellcategory" colspan="2"><strong>Measurement Specifications</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="200">Measurement Range</td>
<td class="speccelldata">-200 to 1360°C</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Resolution</td>
<td class="speccelldata">0.1°C/°F &lt;200°, 1°C/°F &gt;200°</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Accuracy<br />
(@23 ± 5°C)</td>
<td class="speccelldata">±(0.3% reading + 5°C) @ -200°C to -93°C<br />
±(0.3% reading + 1°C) @ -93°C to 1000°C<br />
±(0.5% reading + 1°C) @ 1000°C to 1360°C</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Temperature Coefficient</td>
<td class="speccelldata">0.1 times the applicable accuracy specifications per °C from 0°C to 18°C and 28°C to 50°C</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Note</td>
<td class="speccelldata">Temperature accuracy does not include the accuracy of the type K probe.</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Note</td>
<td class="speccelldata">The temperature scale is based on the international temperature scale of 1990 (ITS90).</td>
</tr>
<tr>
<td class="speccellcategory" colspan="2"><strong>General Specifications</strong></td>
</tr>
<tr>
<td class="speccelltitle" width="200">Display</td>
<td class="speccelldata">Dual Display Multi-function LCD with Backlight</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Input Protection</td>
<td class="speccelldata">60VDC; 24VAC rms</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Display Update Rate</td>
<td class="speccelldata">1 per second</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Over range indication</td>
<td class="speccelldata">&#8220;OL&#8221; appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Open input indication</td>
<td class="speccelldata">&#8220;OL&#8221; appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Low battery indication</td>
<td class="speccelldata">“BT” appears on the LCD</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Power supply</td>
<td class="speccelldata">6 AAA Batteries</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Battery life</td>
<td class="speccelldata">Approximately 200 hours with carbon zinc batteries</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Operating Temperature</td>
<td class="speccelldata">0 to 50°C</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Operating Humidity</td>
<td class="speccelldata">&lt; 80% RH</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Storage Temperature</td>
<td class="speccelldata">-10 to 60°C</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Storage Humidity</td>
<td class="speccelldata">10 to 80% RH</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Dimensions</td>
<td class="speccelldata">150 x 72 x 35mm</td>
</tr>
<tr>
<td class="speccelltitle" width="200">Weight</td>
<td class="speccelldata">Approx. 235g with battery</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://obiat.com.au/product/extech-ea10-easyview-type-k-dual-input-thermometer-dual-readings/">Extech EA10 Dual Input K Type Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/extech-ea10-easyview-type-k-dual-input-thermometer-dual-readings/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-80N Single Input Digital Thermometer</title>
		<link>https://obiat.com.au/product/tenmars-tm-80n-single-input-digital-thermometer/</link>
					<comments>https://obiat.com.au/product/tenmars-tm-80n-single-input-digital-thermometer/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-80n-single-input-digital-thermometer/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-844" src="http://obiat.com.au/wp-content/uploads/2016/02/Tenmars_logo_05.jpg" alt="Tenmars_logo_05" width="228" height="85" /></p>
<p><span style="color: #0000ff;"><span style="color: #000000;">Highly accurate thermometer with 0.05% basic accuracy for precise measurement, complete with soft carry case and bead probe.</span></span></p>
<p><strong><span style="color: #0000ff;"><span style="color: #000000;">Authorised Australian Distributor</span></span></strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-80n-single-input-digital-thermometer/">Tenmars TM-80N Single Input Digital Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h5>TENMARS TM-80N Single Input Thermometer Features:</h5>
<p>&#8211; Dual LCD 5-digit display.<span class="Apple-converted-space"> </span><br />
&#8211; Single input<br />
&#8211; Auto power off with disable function (15 minutes).<span class="Apple-converted-space"> </span><br />
&#8211; Max/Min/Avg/Hold function keys.<span class="Apple-converted-space"> </span><br />
&#8211; °C/°F switchable.<span class="Apple-converted-space"> </span></p>
<p>Tenmars TM-BX series thermometer is a digital thermometer use for thermocouple type. Build in microprocessor and high resolution analog to digital converter chip. The thermocouple probe has fast response, measure wide ranges, easy change shape and popular prices. This popular used to industry and homes.</p>
<table border="1" cellpadding="0">
<tbody>
<tr>
<td width="278"><strong>Model</strong></td>
<td>TM-80N</td>
</tr>
<tr>
<td width="278"><strong>Temperature Units</strong></td>
<td>°C or °F switchable</td>
</tr>
<tr>
<td width="278"><strong>Temperature Range<br />
</strong></td>
<td>Type &#8216;K&#8217; : -200°C to 1370°C  (-328°F to 2498°F)<br />
Type &#8216;J&#8217; : -200°C to 1050°C (-328°F to 1922°F)</td>
</tr>
<tr>
<td width="278"><strong>Resolution</strong></td>
<td>0.1°C and 0.2°F</td>
</tr>
<tr>
<td width="278"><strong>Accuracy<br />
</strong></td>
<td>±(0.05% + 0.7°C)<br />
±(0.05% + 1.4°F)</td>
</tr>
<tr>
<td width="278"><strong>Temperature Coefficient<br />
</strong></td>
<td>0.01% of reading + 0.03°C per °C (0.01% of reading + 0.06°F per °F)<br />
when circumstance out of specified range of 18°C to 28°C (64°F to 82°F)</td>
</tr>
<tr>
<td width="278"><strong>Dimensions</strong></td>
<td>130mm (L) x 56mm (W) x 38mm (D)</td>
</tr>
<tr>
<td width="278"><strong>Weight</strong></td>
<td>Approximately 170g (including battery)</td>
</tr>
<tr>
<td width="278"><strong>Accessories (included)</strong></td>
<td>User manual, 9 volt battery</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-80n-single-input-digital-thermometer/">Tenmars TM-80N Single Input Digital Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/tenmars-tm-80n-single-input-digital-thermometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tenmars TM-82N Dual Input Digital Thermometer</title>
		<link>https://obiat.com.au/product/tenmars-tm-82n-dual-input-digital-thermometer/</link>
					<comments>https://obiat.com.au/product/tenmars-tm-82n-dual-input-digital-thermometer/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/tenmars-tm-82n-dual-input-digital-thermometer/</guid>

					<description><![CDATA[<h4>Dual Input Digital Thermometer</h4>
<p>- Dual LCD 5-digit display.<br />
- Dual input.<br />
- Auto power off with disable function (15 minutes).<br />
- Max/Min/Avg/Hold function keys.<br />
- °C/°F switchable.<br />
- REL, OFFSET, T1-T2.</p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone size-full wp-image-1611" src="http://obiat.com.au/wp-content/uploads/2016/02/WARRANTY3.jpg" alt="WARRANTY 3" width="147" height="45" /></p>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-82n-dual-input-digital-thermometer/">Tenmars TM-82N Dual Input Digital Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<ul>
<li>5-Digit, Dual Liquid Crystal Display.</li>
<li>TM-80N Single Input; TM-82N Dual Input.</li>
<li>Auto power Off, with disable function. (default app. 15 minutes).</li>
<li>Min, Max, Avg and Hold functions.</li>
<li>Relative (REL), Offset.</li>
<li>T1 &#8211; T2 function (TM-82N only).</li>
<li><span style="font-family: Verdana;">°C or °F switchable.</span></li>
</ul>
<p><span style="font-family: Verdana; font-size: medium;"> Application</span></p>
<ul>
<li><span style="font-family: Verdana;"> Highly accurate thermometers with 0.05% basic accuracy for precise measurements.</span></li>
</ul>
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5"><span style="color: #ffffff; font-size: medium;">Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Models</td>
<td bgcolor="#e7f7ff" width="70%">TM-80N and TM-82N</td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Temperature Units</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> °C or °F switchable</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Temperature Range</td>
<td bgcolor="#e7f7ff" width="70%">Type &#8216;K&#8217;: -200°C to 1370°C (-328°F to 2498°F)<br />
Type &#8216;J&#8217;:  -200°C to 1050°C (-328°F to 1922°F)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="30%">Resolution</td>
<td bgcolor="#e7f7ff" width="70%">0.1<span style="font-family: Verdana;">°C and 0.2°F</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Accuracy</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> ±(0.05% + 0.7°C)<br />
±(0.05% + 1.4°F)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#e7f7ff" width="30%">Temperature Coefficient</td>
<td bgcolor="#e7f7ff" width="70%"><span style="font-family: Verdana;"> 0.01% of reading + 0.03°C (0.01% of reading + 0.06°F)<br />
when out of specified range 18°C to 28°C (64°F to 82°F)</span></td>
</tr>
</tbody>
</table>
</td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2"></td>
</tr>
<tr>
<td colspan="2">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#085aa5" width="798"><span style="color: #ffffff; font-size: medium;"> General Specifications</span></td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Dimensions</td>
<td bgcolor="#e7f7ff" width="556">130mm (L) x 56mm (W) x 38mm (D)</td>
</tr>
<tr>
<td bgcolor="#e7f7ff" width="234">Weight</td>
<td bgcolor="#e7f7ff" width="556">approx. 170g (including battery)</td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/tenmars-tm-82n-dual-input-digital-thermometer/">Tenmars TM-82N Dual Input Digital Thermometer</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/tenmars-tm-82n-dual-input-digital-thermometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed SD-947 Thermocouple Thermometer/Logger</title>
		<link>https://obiat.com.au/product/reed-sd-947-thermocouple-thermometerlogger/</link>
					<comments>https://obiat.com.au/product/reed-sd-947-thermocouple-thermometerlogger/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:59 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-sd-947-thermocouple-thermometerlogger/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The Reed SD-947 high temperature thermometer quickly measures temperature using type K/J/T/E/R/S probes, recording individual or max and min readings. The measurements can be saved on the SD memory card for a future analysis using a computer. No extra software needed, just plug the SD card into the computer and it downloads directly to EXCEL. Featuring an easy to read LCD with backlight display, Reed SD-947 shows 4 channels in the same time. You can use this high temperature thermometer with multiple separated probes. This thermometer provides an accurate instant readout of temperature in almost all environments.</p>
<h4>REED SD-947 Features</h4>
<ul class="gkCircle2">
<li>Accepts Type K/J/T/E/R/S Thermometers</li>
<li>Shows 4 channels on the Display</li>
<li>Measures in °C &#38; °F</li>
<li>Offset adjustment for both Type K/J/T/E/R/S &#38; Pt 100 measurements</li>
<li>Real time SD memory card datalogger with a built-in clock and<br />
calendar</li>
<li>Sampling time set from 1 second to 3600 seconds</li>
<li>Meter can switch to a Manual Datalogging</li>
<li>No extra software needed, just plug the SD card into the computer<br />
and it downloads directly to EXCEL</li>
<li>SD card capacity: 1 GB to 16 GB</li>
<li>Easy to read LCD with backlight</li>
<li>Auto power off or manual power off</li>
<li>Data hold, record max. and min. reading</li>
<li>High accuracy microcomputer circuit</li>
<li>Power by UM3/AA (1.5 V) x 6 batteries</li>
<li>USB/RS232 Computer interface</li>
<li>Separated probe for easy measurements of multiple environments</li>
<li>Automatic temperature compensation</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone  wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="147" height="87" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-947-thermocouple-thermometerlogger/">Reed SD-947 Thermocouple Thermometer/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use Reed SD-947 High Temperature Thermometer (Datalogger)</h4>
<p><strong>How to start Type K Measurement</strong><br />
Reed SD-947 is a 4 Channel Thermometer Datalogger which has Type K Temperature sensor by default. The display will show &#8220;K&#8221; icon. Insert the optional Type K probes into the T1, T2, T3, T4 input sockets. The screen will show the 4 channels (T1, T2, T3, T4) and their temperature values. If an input socket is empty, the screen will display “- &#8211; &#8211; &#8211; -”</p>
<p><strong>Type J/T/E/R/S Measurement</strong><br />
You can change the temperature sensor by pressing the &#8220;Type&#8221; Button. The following icons will show on the display: “J/T/E/R/S”. Insert the optional Probes into the T1, T2, T3, T4 input sockets. The screen will show the 4 channels (T1, T2, T3, T4) and their temperature values. If an input socket is empty, the screen will display “- &#8211; &#8211; &#8211; -”.</p>
<p><strong>Pt 100 ohm Measurement</strong><br />
Using again the &#8220;Type&#8221; Button until the screen displays “Pt” you are able to change the Temperature Sensor. Insert the optional Pt 100 ohm Probes into the PT1 and PT2 input sockets. The screen will show the temperature values.</p>
<p><strong>T1-T2 Measurement</strong><br />
With this Reed SD-947 4 Channel Thermometer Datalogger you are able to made T1-T2 measurements. Start using this by inserting the two probes into the meter, either a Thermocouple Probe in the T1 &amp; T2 sockets, or a Pt 100ohm Probe in the PT1 &amp; PT2 sockets. Continue by pressing the &#8220;T1-T2&#8221; button and the display will show the difference value between T1, T2 (or PT1, PT2) on the bottom right of the screen.</p>
<p><strong>Data Hold</strong><br />
To freeze on the screen the measured value, while taking a measurement, press the Hold Button once. Now the display will show the &#8220;HOLD&#8221; symbol and the measured value. Press the Hold Button once again will release the data hold function.</p>
<p><strong>Data Record (Max., Min. reading)</strong><br />
Recording the maximum and minimum readings is also possible with Reed SD-947. Press the REC Button once to start the Data Record function and a “REC” symbol will appear on the display. With the “REC” symbol on the display:</p>
<ul>
<li>Press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. To delete the maximum value, press the Hold Button once and the display will show a “REC.” symbol only and execute the memory function continuously.</li>
<li>Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display. To delete the minimum value, press the Hold Button once, and the display will show a “REC.” symbol only and execute the memory function continuously.</li>
</ul>
<table class="specsalt">
<tbody>
<tr>
<td class="specstop" colspan="4"><strong>Specifications SD-947</strong></td>
</tr>
<tr>
<td class="specs6">RTD Temp. Range</td>
<td class="specs5" colspan="3">-199.99 to 850.0°C (-327.0 to 999.9°F)</td>
</tr>
<tr>
<td class="specs6">Accuracy</td>
<td class="specs5" colspan="3">±(0.4% + 1°C), ±(0.4% + 1.8°F)</td>
</tr>
<tr>
<td class="specs6">Sampling Time</td>
<td class="specs5" colspan="3">1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds</td>
</tr>
<tr>
<td class="specs6">Memory Card</td>
<td class="specs5" colspan="3">SD memory card, 1 GB to 16 GB</td>
</tr>
<tr>
<td class="specs6">Data Output</td>
<td class="specs5" colspan="3">USB/RS232 PC computer interface</td>
</tr>
<tr>
<td class="specs6">Power Supply</td>
<td class="specs5" colspan="3">UM3/AA (1.5 V) x 6 batteries</td>
</tr>
<tr>
<td class="specs6">Dimensions</td>
<td class="specs5" colspan="3">177 x 68 x 45mm (7.0 x 2.7 x 1.9”)</td>
</tr>
<tr>
<td class="specs6">Weight</td>
<td class="specs5" colspan="3">515g</td>
</tr>
<tr>
<td class="specs4" colspan="4">Sensors</td>
</tr>
<tr>
<td class="specs4">Type</td>
<td class="specs4">Resolution</td>
<td class="specs4">Range</td>
<td class="specs4">Accuracy</td>
</tr>
<tr>
<td class="specs6" rowspan="2">Type K</td>
<td class="specs5">0.1°C</td>
<td class="specs5">-100.0 to 1300.0°C</td>
<td class="specs5">± (0.4% + 0.5°C)</td>
</tr>
<tr>
<td class="specs5">0.1°F</td>
<td class="specs5">-148.0 to 2372.0°F</td>
<td class="specs5">± (0.4% + 1°F)</td>
</tr>
<tr>
<td class="specs6" rowspan="2">Type J</td>
<td class="specs5">0.1°C</td>
<td class="specs5">-100.0 to 1200.0°C</td>
<td class="specs5">± (0.4% + 0.5°C)</td>
</tr>
<tr>
<td class="specs5">0.1°F</td>
<td class="specs5">-148.0 to 2192.0°F</td>
<td class="specs5">± (0.4% + 1°F)</td>
</tr>
<tr>
<td class="specs6" rowspan="2">Type T</td>
<td class="specs5">0.1°C</td>
<td class="specs5">-100.0 to 400.0°C</td>
<td class="specs5">± (0.4% + 0.5°C)</td>
</tr>
<tr>
<td class="specs5">0.1°F</td>
<td class="specs5">-148.0 to 752.0°F</td>
<td class="specs5">± (0.4% + 1°F)</td>
</tr>
<tr>
<td class="specs6" rowspan="2">Type E</td>
<td class="specs5">0.1°C</td>
<td class="specs5">-100.0 to 900.0°C</td>
<td class="specs5">± (0.4% + 0.5°C)</td>
</tr>
<tr>
<td class="specs5">0.1°F</td>
<td class="specs5">-148.0 to 999.9°F</td>
<td class="specs5">± (0.4% + 1°F)</td>
</tr>
<tr>
<td class="specs6" rowspan="2">Type R</td>
<td class="specs5">1°C</td>
<td class="specs5">0 to 1700°C</td>
<td class="specs5">± (0.5% + 1°C)</td>
</tr>
<tr>
<td class="specs5">1°F</td>
<td class="specs5">32 to 3092°F</td>
<td class="specs5">± (0.5% + 2°F)</td>
</tr>
<tr>
<td class="specs6" rowspan="2">Type S</td>
<td class="specs5">1°C</td>
<td class="specs5">0 to 1500°C</td>
<td class="specs5">± (0.5% + 1°C)</td>
</tr>
<tr>
<td class="specs5">1°F</td>
<td class="specs5">32 to 2732°F</td>
<td class="specs5">± (0.5% + 2°F)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-947-thermocouple-thermometerlogger/">Reed SD-947 Thermocouple Thermometer/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-sd-947-thermocouple-thermometerlogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed ST-610B Thermocouple Thermometer and Probe Kit</title>
		<link>https://obiat.com.au/product/reed-st-610b-thermocouple-thermometer-and-probe-kit/</link>
					<comments>https://obiat.com.au/product/reed-st-610b-thermocouple-thermometer-and-probe-kit/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:59 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-st-610b-thermocouple-thermometer-and-probe-kit/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>Reed ST-610B is essential where the temperature measurements need to be done with good accuracy and fast response time. Depending on applications, the meter comes with two resolutions: high resolution (0.1°C or 0.1°F) and low resolution (1°C or 1°F). Reed ST-610B measures temperature using a different kind of type K probes and proved to be easy to use Thermocouple Thermometer for checking the temperature in several spots.</p>
<p>REED ST-610B Features</p>
<ul class="gkCircle2">
<li>Compact single input thermocouple thermometer designed for field use</li>
<li>Accuracy to 0.5%</li>
<li>Display maximum reading plus Data Hold</li>
<li>Large LCD display with backlight</li>
<li>User selectable °C or °F or Kelvin</li>
<li>User selectable 0.1°C or 1°C (0.1°F or 1°F) resolution</li>
<li>Accepts K-type thermocouples</li>
<li>Includes 9V battery and holster</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone  wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="130" height="77" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-st-610b-thermocouple-thermometer-and-probe-kit/">Reed ST-610B Thermocouple Thermometer and Probe Kit</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Reed ST-610B Digital Thermocouple Thermometer comes with a large measurement range, from -50°C to 1300°C .This compact, single input thermocouple thermometer is designed for field use. It&#8217;s smaller, lighter (210g), displays maximum reading with a Data Hold function.</p>
<h4 class="title">How to use Reed Digital Type K Thermometer (-50/1300C) (ST-610B)</h4>
<p><b>How to select</b><b> the Temperature Scale</b><br />
Reed ST-610B will turn on with the temperature scales&#8217;s last settings. To change the scale, simply press the °C, °F or K button.</p>
<p><b>Selecting the Display Resolution</b><img fetchpriority="high" decoding="async" class="size-medium wp-image-1614 alignright" src="http://obiat.com.au/wp-content/uploads/2016/02/Reed_ST-610B_picture7-300x300.jpg" alt="Reed_ST-610B_picture7" width="300" height="300" srcset="https://obiat.com.au/wp-content/uploads/2016/02/Reed_ST-610B_picture7-300x300.jpg 300w, https://obiat.com.au/wp-content/uploads/2016/02/Reed_ST-610B_picture7-100x100.jpg 100w, https://obiat.com.au/wp-content/uploads/2016/02/Reed_ST-610B_picture7-150x150.jpg 150w, https://obiat.com.au/wp-content/uploads/2016/02/Reed_ST-610B_picture7.jpg 400w" sizes="(max-width: 300px) 100vw, 300px" /><br />
For this digital thermometer two choices of resolution are available: High resolution (0.1°C or 0.1°F) and Low resolution (1°C or 1°F)</p>
<p><strong>Tc (Temperature Compensator) Checking Mode</strong><br />
Press and hold the Tc button to enter the &#8220;Temperature Compensator-Checking&#8221; mode. The thermometer will display the inside temperature.</p>
<p><strong>Hold and Max Mode</strong><br />
To activate <strong> &#8220;Data Hold&#8221;</strong> mode, press the HOLD button since the &#8220;HOLD&#8221; indicator will be displayed. Now the Reed ST-610B thermometer will “freeze” the present readings and stops all further measurements. Pressing the HOLD button again cancels “HOLD” mode, causing the thermometer to resume taking measurements.<br />
To use the <strong>&#8220;Max Mode&#8221;</strong> just press the MAX button then the instrument will record and update the maximum values. During this measurements the “MAX” indicator appears on the display. Press the MAX button again to exit the “MAX” recording mode. In the “MAX” mode, press the HOLD button to stop the recording, press HOLD again to resume recording.</p>
<p><strong>Optional Accessories:</strong><br />
<strong>Model LS-109</strong> Surface Probe: Ribbon-style surface probe<br />
<strong>Model LS-139</strong> Surface Probe: Spring loaded probe is ideal .<br />
for all high temperature applications<br />
<strong>Model LS-104</strong> Right Angle Surface Probe: Unique right angle .<br />
design allows temperature of hard to reach areas to be taken<br />
<strong>Model LS-103</strong> Air/Gas Probe: Perforated shield permits fast .<br />
response while providing element protection<br />
<strong>Model LS-134A</strong> Needle Tip Probe: Medium gauge hypodermic .<br />
needle tip, used to measure softer foodstuffs, rubber and solids<br />
<strong>Model LS-107</strong> General Purpose Probe: Used to measure both air .<br />
and liquids, but is recommended for immersion applications</p>
<h4>REED ST-610B Specifications</h4>
<ul class="gkCircle2">ELECTRICAL</p>
<li>Temperature Scale: Celsius (C°), Fahrenheit (°F) or Kelvin (K)</li>
<li>Measurement Range: -50°C to 1300°C, -58°F to 2000°F, 223K to 2000K</li>
<li>Resolution: 1°C or 1°F, 0.1°C or 0.1°F,1 K</li>
<li>Accuracy is specified for operating temperatures.over the range of 18°C to 28°C (64°F to 82°F),<br />
for 1 year, not including thermocouple error<br />
±2°C -50°C to 0°C<br />
±4°F -58°F to 32°F<br />
±5K 223K to 273K<br />
±(0.5% rdg+1°C) 0°C to 1000°C<br />
±(0.8% rdg+1°C) 1000°C to 1300°C<br />
±(0.5% rdg+2°F) 32°F to 2000°F<br />
±(1.0% rdg+2K) 273K to 2000K</li>
<li>Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F)</li>
<li>Input protection: 60V DC or 24V RMS AC maximum input voltage on any combination of input pins;</li>
<li>Reading Rate: 2.5 times per second;</li>
<li>Input Connector: Accepts standard miniature thermocouple connectors (flat blades spaced 7.9mm, center to center)<br />
ENVIRONMENTAL</li>
<li>Ambient Operating Range: 0°C to 50°C (32°F to 122°F);</li>
<li>Storage Temperature: -20°C to 60°C (-4°F to 140°F);</li>
<li>Relative Humidity: 0% to 80% (0°C to 35°C) (32°F to 95°F).<br />
0% to 70% (35°C to 50°C) (95°F to 122°F);<br />
GENERAL</li>
<li>Display: 3 ½ digit liquid crystal display (LCD) with a maximum reading of 1999;</li>
<li>Battery: Standard 9V battery (NEDA 1604, IEC 6F22);</li>
<li>Dimensions: 162mm (H) × 76mm (W) × 38.5mm (D);</li>
<li>Weight: 210g</li>
</ul>
<p>The post <a href="https://obiat.com.au/product/reed-st-610b-thermocouple-thermometer-and-probe-kit/">Reed ST-610B Thermocouple Thermometer and Probe Kit</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-st-610b-thermocouple-thermometer-and-probe-kit/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed SD-2010 Heat Stress Meter/Logger</title>
		<link>https://obiat.com.au/product/reed-sd-2010-heat-stress-meterlogger/</link>
					<comments>https://obiat.com.au/product/reed-sd-2010-heat-stress-meterlogger/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:57 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-sd-2010-heat-stress-meterlogger/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>Reed SD-2010 measures how hot it feels when humidity is combined with temperature. Thanks to its incorporated Wet Bulb Globe Temperature (WBGT) this great Datalogger considers the effects of temperature, humidity and direct or radiant sunlight. Reed SD-2010 provides quick and accurate temperature and humidity measurements for assessing environmental heat stress. The instrument features real time SD memory card datalogger with a built-in clock and calendar, clear LCD display and USB/RS232 Computer interface.</p>
<h4>REED SD-2010 Features</h4>
<ul class="gkCircle2">
<li>Wet Bulb Globe Temperature (WBGT) considers the effects of temperature,<br />
humidity and direct or radiant sunlight</li>
<li>Black Globe Temperature (TG) monitors the effects of direct solar<br />
radiation on an exposed surface</li>
<li>In/Out function displays the WBGT value with or without direct sun<br />
exposure</li>
<li>View individual temperatures or indices in either °F or °C</li>
<li>User adjustable WBGT threshold with audible alarm if threshold is<br />
exceeded</li>
<li>Real time SD memory card datalogger with a built-in clock and<br />
calendar</li>
<li>Sampling time set from 1 second to 3600 seconds</li>
<li>Meter can switch to a Manual Datalogging</li>
<li>No extra software needed, just plug the SD card into the computer<br />
and it downloads directly to EXCEL</li>
<li>SD card capacity: 1 GB to 16 GB</li>
<li>Easy to read LCD with backlight</li>
<li>Auto power off or manual power off</li>
<li>Data hold, record max. and min. reading</li>
<li>High accuracy microcomputer circuit</li>
<li>Power by UM3/AA (1.5 V) x 6 batteries</li>
<li>USB/RS232 Computer interface</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone  wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="136" height="80" /></p>
<p><a href="https://www.youtube.com/watch?v=vBO62qt6E4s&#38;nohtml5=False" target="_blank"><img class="alignnone  wp-image-2707" src="http://obiat.com.au/wp-content/uploads/2016/02/VIDEO-3.jpg" alt="VIDEO" width="191" height="107" /> <img class="alignnone  wp-image-1648" src="http://obiat.com.au/wp-content/uploads/2016/02/Play.jpg" alt="Play" width="92" height="69" /></a></p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-2010-heat-stress-meterlogger/">Reed SD-2010 Heat Stress Meter/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use REED SD-2010 Heat Stress Meter and Datalogger</h4>
<p><strong>Dew Point Temperature Measurement</strong></p>
<p>Turn on the meter by pressing the Power Button. Function select to “dP”. The upper Display will show the Dew Point Temperature value. The lower Display will show the text “dP”.</p>
<p><strong>TG Measurement</strong></p>
<p>Turn on the meter by pressing the Power Button. Function select to “tg”. The upper Display will show the TG value. The lower Display will show the text “tg”.</p>
<p><strong>Humidity and TA Measurement</strong></p>
<p>Turn on the meter by pressing the Power Button. Function select to “rH”. The upper Display will show the Humidity value. The lower Display will show the TA value.</p>
<p><strong>Data Hold</strong></p>
<p>While taking a measurement, press the Hold Button once and the measured value will hold on the screen, and a HOLD symbol will appear. Press the Hold Button once again will release the data hold function.</p>
<p><strong>Data Record (Max., Min. reading)</strong></p>
<p>The data record function records the maximum and minimum readings. Press the REC Button once to start the Data Record function and a “REC” symbol will appear on the display. With the “REC” symbol on the display: Press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. To delete the maximum value, press the Hold Button once and the display will show a “REC.” symbol only and execute the memory function continuously. Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display. To delete the minimum value, press the Hold Button once, and the display will show a “REC.” symbol only and execute the memory function continuously. To exit the memory record function, press the REC button for 2 seconds. The display will revert to the current reading.</p>
<p><strong>Datalogger</strong></p>
<p>Preparation Before Executing the Datalogger Function: Insert the optional SD card into the SD card socket. 2) Before you use an SD card with this meter for the first time, it is recommend to format the SD card. See Advanced Settings section of this manual for instructions. If this is the first time the meter is used you need to adjust the clock. See Advanced Settings section of this manual for instructions. Now you need to set the decimal format. The numerical data structure downloaded to the SD card is defaulted used the “.” as the decimal, for example “20.6” “1000.53”. But in certain countries the “,” is used as the decimal point, for example “20, 6” “1000,53”. See Advanced Settings section of this manual for instructions on how to change the Decimal Character.</p>
<p><strong>Auto Datalogger (Set sampling time ≥1 second)</strong></p>
<p>Start Datalogging; press the REC Button, and the “REC” symbol will appear on the LCD screen, then press the Logger Button, the “REC” symbol will flash while the measuring data and time information is being saved in memory. To set the sampling time, and to toggle the beeper sound on or off, refer to the Advanced Settings section of this manual. Pause the Datalogging; while Datalogging, if press the Logger Button once. While paused, the “REC” symbol will stop flashing. Press the Logger Button again to resume Datalogging, and the “REC” symbol will begin to flash again. Stop Datalogging; while the Datalogger function is paused, press the REC Button for 2 seconds. The “REC” symbol will disappear indicating the Datalogging function has stopped.</p>
<p><strong>Manual Datalogger (Set sampling time = 0 seconds)</strong></p>
<p>Set sampling time is to 0 second; Press the REC Button, and the “REC” symbol will appear on the LCD screen. Press the Logger Button, and the “REC” symbol will flash once and one Beep will sound, at the same time the measuring data along the time information will be saved in memory. The lower Display will show the Position (record) number, which is saved as well. To Change the Position Number; press the Down Button and the lower position number will flash on the display. Press the Up or Down Buttons to set the Position Number (1 to 99) to help identify the measurement location. The lower Display will show P x (x = 1 to 99). After the position number is selected, press the Enter Button to confirm. Stop Datalogging; press the REC Button for 2 seconds, and the “REC” symbol will disappear indicating the Datalogging function has stopped.</p>
<p>Data Transfer from SD card to Computer (EXCEL Software)</p>
<p>After Datalogging, remove the SD card from the SD card slot. Plug in the SD card into the Computer’s SD card slot or insert the SD card into the optional SD card adapter and connect to your Computer. Turn your computer on and a folder will appear on your desktop representing you SD card. Open “Microsoft EXCEL”. Download the EXCEL files from the SD Card to the computer by opening up the SD folder and selecting the desired EXCEL files, and drag-and-drop them onto your Computer. Open the files with EXCEL (File – Open). he EXCEL file will have the following column headers in this order: Place (Position Number), Date (Year/Month/Day), Time (in 24h clock), Value, and Unit.</p>
<h4>REED SD-2010 Specifications</h4>
<table>
<tbody>
<tr>
<td>
<ul class="gkCircle2">
<li>Circuit: Custom microprocessor LSI circuit</li>
<li>Display: 52mm x 38mm LCD with backlight</li>
<li>Measurements: Indoor/Outdoor Wet Bulb Globe Temperature</li>
<li>(WBGT), Black Globe Temperature (TG), Air</li>
<li>Temperature (TA), Wet Bulb Temperature (WB),</li>
<li>Humidity, Dew Point Temperature</li>
<li>Temperature units: (°C, °F)</li>
<li>Auto Sampling Time: 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800,</li>
<li>3600 seconds</li>
<li>Memory Card: SD memory card, 1 GB to 16 GB</li>
<li>Sampling Time: Approx. 1 second</li>
<li>Data Output: USB/RS232 PC computer interface</li>
<li>Resolution: 0.1°C/0.1°F</li>
<li>Operating Temperature: 0-50°C (0-122°F)</li>
<li>Operating Humidity: Less than 85% R.H.</li>
<li>Power Supply: UM3/AA (1.5 V) x 6 batteries</li>
<li>Weight: 515g/1.13lb</li>
<li>Dimensions: Main instrument: 177 x 68 x 45mm;</li>
<li>Black Brass Ball: 75mm Dia.</li>
<li>Includes: Black Brass Ball (with sensor) and soft</li>
<li>carrying case</li>
</ul>
</td>
</tr>
</tbody>
</table>
<p><strong>Wet Bulb Globe Temperature</strong></p>
<p>Indoor formula: 0.7WB + 0.3TG<br />
Indoor Range: 0°C &#8211; 59°C (32°F &#8211; 138°F)<br />
Indoor Accuracy: ±1°C (± 1.8°F)</p>
<p>Outdoor formula: 0.7WB + 0.3TG + 0.1TA<br />
Outdoor Range: 0°C &#8211; 56°C (32°F &#8211; 132°F)<br />
Outdoor Accuracy: ±1.5°C (± 2.7°F)</p>
<p><strong>Air temperature (TA)</strong></p>
<p>Range: 0 &#8211; 50°C (32 &#8211; 122°F)<br />
Accuracy: ±0.8°C (± 1.5°F)<br />
Dew Point Temp. Range: -25.3 &#8211; 48.9°C (-13.5 to 120.1°F)<br />
Wet Bulb Temp. Range: -21.6 &#8211; 50.0°C (-6.9 to 122.2°F)</p>
<p><strong>Black globe temperature (TG)</strong></p>
<p>Range: 0 &#8211; 80°C (32 &#8211; 176°F)<br />
Accuracy: ±0.6°C (± 1.1°F)</p>
<p><strong>Humidity</strong></p>
<p>Range: 5% &#8211; 95% RH<br />
Resolution: 0.1% RH<br />
Accuracy: ≥70% RH: ± (3% reading + 1% RH); &lt;70% RH: ± 3% RH.</p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-2010-heat-stress-meterlogger/">Reed SD-2010 Heat Stress Meter/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-sd-2010-heat-stress-meterlogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed SD-3007 Digital Thermo-Hydrometer/Logger</title>
		<link>https://obiat.com.au/product/reed-sd-3007-digital-thermo-hydrometerlogger/</link>
					<comments>https://obiat.com.au/product/reed-sd-3007-digital-thermo-hydrometerlogger/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:57 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-sd-3007-digital-thermo-hydrometerlogger/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The Reed SD-3007 is an easy to use instrument that is recommended to any one that needs to buy an extremely configurable measurement instrument. In addition, this Reed R-3007 portable hygrometer comes with w/ type k thermocouple, data logger feature and high level of measurement accuracy. The R-3007 humidity tester can be used in a range of up 5% to 95% RH and 0 to 50°C for temperature measurements. Easy to use, designed to fit your hand, R-3007 confirms the expectations and its specifications and features proved to be what you have expected more on one good portable hygrometer: Humidity/Temperature measurements, Dew Point measurements, Wet Bulb measurements, Data Hold and Data Record, Max. and Min. reading. On top of that, you don't need an extra software. Just plug the SD card into the computer and it downloads directly to EXCEL. Buy this thermo-hygrometer with Real time SD memory card datalogging feature, available with USB/RS232 PC computer interface and Humidity/Temp. Probe.</p>
<h4>REED SD-3007 Features</h4>
<ul class="gkCircle2">
<li>Dew point and Wet bulb humidity measurements</li>
<li>Type K, Type J thermocouple thermometer</li>
<li>Fast humidity measuring response time</li>
<li>Real time SD memory card datalogger with a built-in clock and<br />
calendar</li>
<li>No extra software needed, just plug the SD card into the computer<br />
and it downloads directly to EXCEL</li>
<li>SD card capacity: 1 GB to 16 GB</li>
<li>Easy to read LCD with backlight</li>
<li>Auto power off or manual power off</li>
<li>Data hold, record max. and min. reading</li>
<li>High accuracy microcomputer circuit</li>
<li>Power by UM3/AA (1.5 V) x 6 batteries</li>
<li>USB/RS232 Computer interface</li>
<li>Separated probe for easy measurements of multiple environments</li>
<li>Automatic temperature compensation for the anemometer and type<br />
K/J thermometer</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="144" height="85" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-3007-digital-thermo-hydrometerlogger/">Reed SD-3007 Digital Thermo-Hydrometer/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use REED SD-3007 Thermo-hygrometer w/ type k thermocouple, data logger</h4>
<p><strong>Humidity/Temperature measurement</strong><br />
Plug the Probe into the SD-3007&#8217;s Probe Input Socket, then power on the meter by pressing the Power Button. Press and hold the Function Button and choose the “rH” function. With the meter connected with the probe, continue the humidity/temperature measurements by holding the Probe Handle and face the Probe Head against the measuring source. The top part of the Display will show the Humidity value, and the lower part of the Display will show the Temperature value.</p>
<p><strong>Dew Point and Wet bulb measurements</strong><br />
Before use this Thermo-hygrometer for dew point test, using the function button select the “dP” position. Hold the Probe Handle and face the Probe Head against the measuring source. The top part of the Display will show the Dew Point value, and the lower part of the Display will show “dP”. For wet bulb measurements select the “_Et” function and repeat the Dew Point measurement procedure.</p>
<p><strong>Type K/J Thermometer measurement</strong><br />
With your Reed SD-3007 turned off plug the optional Type K or J Thermocouple Probe into the Type K/J Probe Input Socket. Be sure the Probe is not plugged in. Now turn on the instrument and the screen will display a “K”, meaning it is configured for a Type K thermometer probe. Please then wait a moment for the meter and the measured temperature will now be displayed on the display screen. To change the meter to accept a Type J Probe, please see the Advanced Settings section.</p>
<p><strong>Using the Data Hold and Data Record function</strong><br />
During any measurements you can hold on the screen the measured value by pressing down the HOLD button. Press Rec Button once to start the Data record function. With REC active the Reed SD-3007 records the min and max readings. To exit the memory record function, press the REC button for 2 seconds. The display will revert to the current reading.</p>
<p><strong>Auto Datalogger</strong><br />
With the automatic datalogging function you save the measuring data and time information into the memory. Before using this feature you need to insert the optional SD card into the SD card socket. Start using the dataloggin by pressing the REC Button. After the REC symbol will appeared, the data values and time will be saved on the SD card. During the datalogging operation, if you press the Logger Button once you will pause the datalogging, the “REC” symbol will stop flashing. Press the Logger Button again to resume Datalogging, and the “REC” symbol will begin to flash again.</p>
<p><strong>Manual Datalogger (Set sampling time = 0 seconds)</strong><br />
Set sampling time is to 0 second; Press the REC Button, and the “REC” symbol will appear on the LCD screen. Press the Logger Button, and the “REC” symbol will flash once and one Beep will sound, at the same time the measuring data along the time information will be saved in memory. The lower Display will show the Position (record) number, which is saved as well. To Change the Position Number; press the Down Button and the lower position number will flash on the display. Press the Up or Down Buttons to set the Position Number (1 to 99) to help identify the measurement location. The lower Display will show P x (x = 1 to 99). After the position number is selected, press the Enter Button to confirm. Stop Datalogging; press the REC Button for 2 seconds, and the “REC” symbol will disappear indicating the Datalogging function has stopped.</p>
<h4>REED SD-3007 Specifications</h4>
<ul class="gkCircle2">
<li>Circuit: Custom microprocessor LSI circuit</li>
<li>Display: 52mm x 38mm LCD with backlight</li>
<li>Humidity Temp. units: %RH / °C or °F</li>
<li>Dew Point/Wet Bulb units: (°C, °F)</li>
<li>Temperature units: (°C, °F)</li>
<li>Auto Sampling Time: 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800,<br />
3600 seconds</li>
<li>Memory Card: SD memory card, 1 GB to 16 GB</li>
<li>Sampling Time of Display: Approx. 1 second</li>
<li>Data Output: USB/RS232 PC computer interface</li>
<li>Temperature Range: 0-50°C (0-122°F)</li>
<li>Resolution: 0.1°C/0.1°F</li>
<li>Accuracy: ± 0.8°C/1.5°F</li>
<li>Operating Temperature: 0-50°C (0-122°F)</li>
<li>Operating Humidity: Less than 85% R.H.</li>
<li>Power Supply: UM3/AA (1.5 V) x 6 batteries</li>
<li>Weight: 515g/1.13lb</li>
<li>Dimensions: 177 x 68 x 45mm (7.0 x 2.7 x 1.9”)</li>
<li>Includes: Humidity/Temperature probe</li>
</ul>
<table>
<tbody>
<tr>
<td></td>
<td><strong>Humidity</strong></td>
<td><strong>Temperature</strong></td>
<td><strong>Dew Point</strong></td>
<td><strong>Wet Bulb</strong></td>
</tr>
<tr>
<td>Range</td>
<td>5% to 95% RH</td>
<td> 0 &#8211; 50°C</p>
<p>32 &#8211; 122°F</td>
<td> -25.3°C &#8211; 48.9°C,<br />
-13.5°F &#8211; 120.1°F</td>
<td> -21.6°C &#8211; 50.0°C,<br />
-6.9°F &#8211; 122.0°F</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1% RH</td>
<td> 0.1°</td>
<td>  0.1°</td>
<td>   0.1°</td>
</tr>
<tr>
<td>Accuracy</td>
<td>≥70% RH: ± (3% reading + 1% RH)<br />
&lt; 70% RH: ± 3% RH</td>
<td> ±0.8°C, ±1.5°F</td>
<td> &#8211;</td>
<td> &#8211;</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/reed-sd-3007-digital-thermo-hydrometerlogger/">Reed SD-3007 Digital Thermo-Hydrometer/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-sd-3007-digital-thermo-hydrometerlogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed SD-9300 Environmental Meter/Datalogger</title>
		<link>https://obiat.com.au/product/reed-sd-9300-environmental-meterdatalogger/</link>
					<comments>https://obiat.com.au/product/reed-sd-9300-environmental-meterdatalogger/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:11:51 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-sd-9300-environmental-meterdatalogger/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The REED SD-9300 Environmental Meter/Datalogger is a multi-functional handheld instrument for the measurement, logging and analyzing parameters specific for indoor or outdoor environments such air temperature, wind speed, air humidity, light and noise (with the optional adapter).</p>
<h4>REED SD-9300 Features</h4>
<ul>
<li>Humidity measurements shown in both %RH and Temp</li>
<li>Anemometer can default the display unit to m/S, FPM, Km/h, mph, knot</li>
<li>Light meter can display LUX or Ft-cd</li>
<li>Real time SD memory card datalogger with a built-in clock and calendar</li>
<li>Meter can switch to a Manual Datalogging</li>
<li>No extra software needed, just plug the SD card into the computer and it downloads directly to EXCEL</li>
<li>SD card capacity: 1 GB to 16 GB</li>
<li>Easy to read LCD with backlight</li>
<li>Auto power off or manual power off</li>
<li>Data hold, record max. and min. reading</li>
<li>Power by UM3/AA (1.5 V) x 6 batteries</li>
<li>USB/RS232 Computer interface</li>
</ul>
<p><a href="http://obiat.com.au/wp-content/uploads/2016/02/sd-9300-manual.pdf"><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" /></a>  <a href="http://obiat.com.au/wp-content/uploads/2016/02/sd-9300-manual.pdf" target="_blank" rel="">REED SD-9300 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="114" height="68" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-9300-environmental-meterdatalogger/">Reed SD-9300 Environmental Meter/Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Reed SD-9300 assures excellent performance and accuracy for a large kind of environmental measurements including: Type K/J temperature tests, tests humidity and temperature in the same time, air velocity or light intensity measurements. With an optional adapter the Reed SD-9300 can be used for sound level monitoring.</p>
<h4 class="title">How to use Reed Environmental Meter (SD-9300)</h4>
<p><strong>Air velocity/Temperature measurement</strong><br />
Plug the Probe Plug into the Probe Input and power on your Reed SD-9300. When the meter is on, press and hold the Function Button and choose “An” function for Air velocity/temperature measurements. Release the Function Button and confirm your selection. With the &#8220;Air velocity&#8221; function selected, <strong>change the Air velocity unit</strong>, by pressing and the Unit Button. The display will flash the units m/S, Km/h, mph, Knot, &amp; FPM. Release the Unit Button to select the displayed unit. The selected unit will be saved as the default.Hold the Probe Handle and face the Anemometer Head against the measuring airflow source. The air velocity measurement value will be displayed on top part of the environmental meter&#8217;s display and the lower part of the display will show the air temperature value.</p>
<p><strong>Humidity/Temperature measurement</strong><br />
Plug the Probe Plug into the Probe Input Socket, then power on the Environmental Meter by pressing the Power Button. Using the &#8220;function&#8221; button choose &#8220;rH&#8221; function. The top part of the Display will show the %RH value, and the lower part of the Display will show the temperature value.</p>
<p><strong>Type K/J Thermometer measurement</strong><br />
Plug the optional Type K or J Thermocouple Probe into the Type K/J Probe Input Socket. Be sure the Air Velocity Probe is not plugged in. Select the “tP” function. The screen will display a “K”, meaning it is configured for a Type K thermometer probe. The measured temperature will now be displayed on the display screen.</p>
<p><strong>Light Meter measurement</strong><br />
When the meter is off, plug the Probe Plug into the Probe Input Socket, then power on the meter by pressing the Power Button. Power on the instrument and select the “LIgHt” function. Hold the Probe Handle and face the Light Sensor against the measuring light source. The top part of the Display will show the light measurement value. To<strong>change the Light Meter unit</strong>, press and hold the Unit Button, while in the Light Meter Function. The display will flash the units LUX and Ft-cd. Release the Unit Button to select the displayed unit.</p>
<p><strong>Sound Level measurement (optional probe required)</strong><br />
Plug the optional Sound Adapter Plug into the Probe Input Socket and power on the Sound Adapter. Power on the meter by pressing the Power Button. The meter’s Display will show the symbol “Sound” and is ready to take sound level measurements. The display will show the measuring sound value with unit “dB”.</p>
<p><strong>Data Hold and Data Record (Max., Min. reading)</strong><br />
You can freeze the measurement value by pressing the Hold Button during the operation. Press the REC Button once to start the <strong>Data Record function. </strong>By pressing the REC Button you can switch between the REC MAX reading and the REC MIN reading for the minimum value of the measurements.</p>
<p><strong>Datalogger</strong><br />
Using an optional SD card you can use the datalogger function of the instrument. The information can be logged using Auto Datalogger or Manual Datalogger mode. Using Manual Mode, you have to set the parameters, such as the sampling time, while using Auto mode the setting will be made automatically by the meter.</p>
<h4>REED SD-9300 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td colspan="2"><strong>Air Velocity</strong></td>
</tr>
<tr>
<td>Range</td>
<td>0.4 to 30.0 m/s<br />
1.4 to 128.0 km/h<br />
0.9 to 78.3 mph<br />
79 to 6890 fpm<br />
0.8 to 68.0 knots</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1 m/s<br />
0.1 km/h<br />
0.1 mph<br />
1 fpm<br />
0.1 knot</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±2% + 0.2 m/s (0.8 km/h; 0.4 mph; 40 fpm; 0.4 knot)</td>
</tr>
<tr>
<td colspan="2"><strong>Humidity</strong></td>
</tr>
<tr>
<td>Range</td>
<td>0% to 95% RH</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1% RH</td>
</tr>
<tr>
<td>Accuracy</td>
<td>≥70% RH: ± (3% reading + 1% RH)<br />
&lt; 70% RH: ± 3% RH</td>
</tr>
<tr>
<td colspan="2"><strong>Light</strong></td>
</tr>
<tr>
<td>Range</td>
<td>0 to 20,000 Lux (0 to 1,860 Ft-cd)</td>
</tr>
<tr>
<td>Resolution</td>
<td>1 Lux (0.1 Ft-cd)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(5% rdg ± 8 dgt)</td>
</tr>
<tr>
<td colspan="2"><strong>Thermocouple Temperature</strong></td>
</tr>
<tr>
<td>Range</td>
<td>Type K: -100.0 to 1300.0°C (-148.0 to 2372°F)<br />
Type J: -100.0 to 1200.0°C (-148.0 to 2192°F)</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.1°C/°F</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±(0.4% +0.5°C/+1°F)</td>
</tr>
<tr>
<td colspan="2"><strong>General Specifications</strong></td>
</tr>
<tr>
<td>Power Supply</td>
<td>6 x 1.5V UM3/AA batteries</td>
</tr>
<tr>
<td>Dimensions</td>
<td>Meter: 135 x 60 x 33mm<br />
Probe: 105 x 46 x 29mm</td>
</tr>
<tr>
<td>Weight</td>
<td>515g</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/reed-sd-9300-environmental-meterdatalogger/">Reed SD-9300 Environmental Meter/Datalogger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-sd-9300-environmental-meterdatalogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
