<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Water Quality Archives - Obiat Electronics</title>
	<atom:link href="https://obiat.com.au/product-tag/water-quality/feed/" rel="self" type="application/rss+xml" />
	<link>https://obiat.com.au/product-tag/water-quality/</link>
	<description>keeping your industry up and running</description>
	<lastBuildDate>Mon, 17 Jun 2019 12:27:32 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://obiat.com.au/wp-content/uploads/2016/05/obiat_logo_2-100x100.jpg</url>
	<title>Water Quality Archives - Obiat Electronics</title>
	<link>https://obiat.com.au/product-tag/water-quality/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>REED R9600 Salinity Refractometer, 0-28%</title>
		<link>https://obiat.com.au/product/reed-r9600-salinity-refractometer-0-28/</link>
					<comments>https://obiat.com.au/product/reed-r9600-salinity-refractometer-0-28/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 21 Apr 2016 06:44:14 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2893</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>REED R9600 salinity refractometer can be used to measure artificial seawater in aquariums, holding tanks and breeding ponds, brine concentration for pickling solutions as well as measuring the concentration of saltwater used in rinsing and cooking sea products.</p>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/04/r9600-manual.pdf" target="_blank" rel="">REED R9600 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone  wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="103" height="61" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-r9600-salinity-refractometer-0-28/">REED R9600 Salinity Refractometer, 0-28%</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>REED R9600 Offers</h4>
<p><strong>Features</strong></p>
<ul>
<li>Salinity refractometers are useful for measuring the concentration of natural or artificial seawater in aquariums, holding tanks, and breeding ponds</li>
<li>They can also be used for controlling the saltwater concentration when preparing pickles, measuring the concentration of saltwater used in rinsing and cooking sea products</li>
</ul>
<h4>REED R9600 Specifications</h4>
<table class="table table-striped">
<tbody>
<tr>
<td>Range</td>
<td>0 to 28%</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.2%</td>
</tr>
<tr>
<td>Accuracy</td>
<td>±0.2%</td>
</tr>
<tr>
<td>Automatic Temperature Compensation Range</td>
<td>10 to 30°C</td>
</tr>
</tbody>
</table>
<h4>Calibration</h4>
<p>1. Open the cover plate &amp; place 2-3 drops of distilled water onto the prism surface, close the cover plate, press lightly &amp; ensure the water spreads evenly across the whole surface area without air bubbles or dry sections. (wait 30seconds until the water adjusts to ambient temperature)</p>
<p>2. Hold towards light source &amp; look into the eyepiece, if the boundary line between the upper blue field &amp; the lower white field is not located exactly on the 0°C waterline, adjust the correcting screw until both lines meet.</p>
<p>3. Wipe the water from the prism with clean dry cloth &amp; replace the rubber correcting screw cover.</p>
<p>NOTE: under normal operating conditions the calibration only needs to be checked periodically</p>
<h4>Maintenance</h4>
<p>1. If the ambient temperature is not within the automatic temperature compensation range (10 &#8211; 30°C) the instrument must be calibrated before testing commences.</p>
<p>2. The prism must be cleaned thoroughly with a soft, clean damp cloth after each use – failure to do so will result in inaccurate readings &amp; possible long term damage</p>
<p>3. The instrument must be kept in a dry clean environment to prevent condensation forming on the optical components</p>
<p>4. If used in accordance with the instructions &amp; all warning are followed – the optical performance will remain constant &amp; the instrument will give many years of reliable service.</p>
<p>The post <a href="https://obiat.com.au/product/reed-r9600-salinity-refractometer-0-28/">REED R9600 Salinity Refractometer, 0-28%</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r9600-salinity-refractometer-0-28/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>REED R9500 BRIX Refractometer, 0-32%</title>
		<link>https://obiat.com.au/product/reed-r9500-brix-refractometer-0-32/</link>
					<comments>https://obiat.com.au/product/reed-r9500-brix-refractometer-0-32/#respond</comments>
		
		<dc:creator><![CDATA[Mike]]></dc:creator>
		<pubDate>Thu, 21 Apr 2016 02:26:37 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/?post_type=product&#038;p=2886</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The REED R9500 BRIX refractometer shows the concentration percentage of the soluble solids content of a sample in a range: 0 to 32%</p>
<h4>Ideal Applications for the REED R9500</h4>
<ul>
<li>Fruit and Citrus Industry</li>
<li>Juice Factories</li>
<li>Vineyards</li>
<li>Food Preparation</li>
<li>Consumer Use</li>
<li>Agriculture</li>
</ul>
<p><img class="alignnone size-full wp-image-1367" src="http://obiat.com.au/wp-content/uploads/2016/03/logopdf-2.jpg" alt="PDF" width="58" height="58" />   <a href="http://obiat.com.au/wp-content/uploads/2016/04/r9500-manual.pdf" target="_blank" rel="">REED R9500 Instruction Manual</a></p>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="106" height="63" /></p>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/reed-r9500-brix-refractometer-0-32/">REED R9500 BRIX Refractometer, 0-32%</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4><strong>REED R9500 Features:</strong></h4>
<ul>
<li>The REED R9500 Brix Refractometer shows the concentration percentage of the soluble solids content (total solids) of a sample (water solution)</li>
<li>The soluble solids content is the total of all the solids dissolved in the water &#8211; beginning with sugar, salts, protein, acids, etc. and the measurement reading value is the value of the sum total of these</li>
<li>Brix% is calibrated to the number of grams of cane sugar contained in 100g of cane sugar solution (When measuring a sugar solution, the Brix% should perfectly match the actual concentration)</li>
</ul>
<div class="parsys_column colCtrlBasic1-0">
<div class="parsys_column colCtrlBasic1-0-c0">
<div class="parbase section text">
<p>BRIX measurement is a well known application in the food and beverage industry. Strictly speaking the BRIX measurement is the determination of pure sucrose content in water (1 degree Brix = 1g of sucrose in 100g of solution), but the BRIX measurement is used in many other applications (soft drinks, fruit juices, tomato concentrates, etc..) which are very often far away from pure sucrose/water solutions. This has been leading to some confusions, especially when comparing results obtained with different measuring techniques (hydrometer, pycnometer, refractometer, digital density meter).</p>
</div>
</div>
</div>
<div> <strong>Different sample types</strong></div>
<div class="parsys_column colCtrlBasic2-4">
<div class="parsys_column colCtrlBasic2-4-c0">
<div class="parbase section text">
<p>When measuring samples other than pure sucrose content in water different results will be obtained when using different techniques (hydrometer, pycnometer, refractometer, digital density meter).</p>
</div>
</div>
</div>
<p>The post <a href="https://obiat.com.au/product/reed-r9500-brix-refractometer-0-32/">REED R9500 BRIX Refractometer, 0-32%</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-r9500-brix-refractometer-0-32/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed SD-4307 Conductivity/TDS/Salinity Meter/Logger</title>
		<link>https://obiat.com.au/product/reed-sd-4307-conductivitytdssalinity-meterlogger/</link>
					<comments>https://obiat.com.au/product/reed-sd-4307-conductivitytdssalinity-meterlogger/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:00 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-sd-4307-conductivitytdssalinity-meterlogger/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The SD-4307 is a Reed conductivity meter compatible with carbon rod electrode type conductivity probe. The Reed SD-4307 TDS salinity meter is powered by custom microprocessor LSI circuit and can records data for a further computer analysis. The meter has 3 conductivity units (μ,S, mS) and shows the salinity level in %. It features a large, easy-to-read LCD display and simple push-button operation. The Reed SD-4307 has a good auto sampling time, from 1 second to 9 hours and can operates in any environment with humidity less than 85% R.H.</p>
<p>REED SD-4307 Features</p>
<ul class="gkCircle2">
<li>Circuit: Custom microprocessor LSI circuit</li>
<li>Display: 52mm x 38mm LCD with backlight</li>
<li>Conductivity Units: μ,S, mS</li>
<li>TD S Units: PPM</li>
<li>Salt Units: % (of weight)</li>
<li>Conductivity Probe: Carbon rod electrode</li>
<li>Auto Sampling Time: 1 second to 9 hours</li>
<li>Memory Card: SD memory card, 1 GB to 16 GB</li>
<li>Sampling Time of Display: Approx. 1 second</li>
<li>Data Output: USB/RS232 PC computer interface</li>
<li>Temperature Range: 0-50°C (0-122°F)</li>
<li>Resolution: 0.1°C/0.1°F</li>
<li>Accuracy: ± 0.8°C/1.5°F</li>
<li>Operating Temperature: Meter: 0-50°C; Probe: 0-60°C</li>
<li>Operating Humidity: Less than 85% R.H.</li>
<li>Power Supply: UM3/AA (1.5 V) x 6 batteries</li>
<li>Weight: 515g/1.13lb</li>
<li>Dimensions:<br />
Meter: 177 x 68 x x45mm (7.0 x 2.7 x 1.9”)<br />
Probe: 22mm Dia. X 120mm Length</li>
<li>Includes:<br />
Conductivity/TDS/Salt Probe<br />
and a Hard Carrying Case</li>
<li>Optional accessories:<br />
2G SD Card (SD-2GB)<br />
USB cable (USB-01)<br />
RS232 cable (UPCB-01)<br />
Data Acquisition Software (SW-U801-WIN)<br />
Tripod (BS-6)</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone  wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="132" height="78" /></p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-4307-conductivitytdssalinity-meterlogger/">Reed SD-4307 Conductivity/TDS/Salinity Meter/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use Reed SD-4307 TDS Salinity Meter (Data Logger)</h4>
<p><strong>Function selection</strong><br />
This Reed Salt/TDS/Conductivity Datalogger meter has 3 measuring functions to choose from: Conductivity, TDS, and Salt. With the instrument powered on, press and hold the Function Button. The display will flash “Cd”, for Conductivity measurements, “tdS” for TDS measurements, and “SALt” for Salt measurements. Release the Function Button to choose the displayed function.<br />
The meter is defaulted to Auto Range mode. Push the Range Button to change the range from 200μS, 2mS, 20mS, 200mS and Auto Range.</p>
<p><strong>Zero Adjustment</strong><br />
If the probe is not immersed in the measuring solution and the display will not show a Zero Value. Press and hold the Up Button for about 10 seconds and the display will then show zero. The Zero function is only valid for the 200μS range and not when the Zero Value is &lt; 2.0μS.</p>
<p><strong>Conductivity Measurements</strong><br />
Always plug the Probe Plug into the Probe Socket with your meter switched off. Now power on the meter by pressing the Power Button. Select the “Cd” function and hold the Probe Handle and fully immerse the Probe Sensor into the measuring solution. Shake the Probe to let the Probe’s internal air bubble drift out from under the sensing head. The top part of the Display will show the conductivity mS (μS) values, and the lower part of the Display will show the temperature value of the solution.</p>
<p><strong>TDS Measurement</strong><br />
With your salinity meter switched meter is off, plug the Probe Plug into the Probe Socket, then power on the meter by pressing the Power Button. Using the Function Select, navigate until the “tdS” function icon is displayed on the screen. Hold the Probe Handle and fully immerse the Probe Sensor into the measuring solution. The Display will show the Total Dissolved Solids value.</p>
<p><strong>Salt Measurements</strong><br />
Before starts any salt measurements, your meter need to have the probe plug plugged into the Probe socket and the “SALt” function selected. The procedure is similar as TDS measurements. The display will show the Salt value (% of weight).</p>
<p><strong>Data Record (Max., Min. reading)</strong><br />
The data record function records the maximum and minimum readings. Press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display.</p>
<p><strong>Auto Datalogger</strong><br />
Press the REC Button, and the “REC” symbol will appear on the LCD screen, then press the Logger Button, the “REC” symbol will flash while the measuring data and time information is being saved in memory. To set the sampling time, and to toggle the beeper sound on or off, refer to the Advanced Settings section of this manual. Pause the Datalogging; while Datalogging, if press the Logger Button once. While paused, the “REC” symbol will stop flashing. Press the Logger Button again to resume Datalogging, and the “REC” symbol will begin to flash again.Stop Datalogging; while the Datalogger function is paused, press the REC Button for 2 seconds. The “REC” symbol will disappear indicating the Datalogging function has stopped.</p>
<p><strong>Manual Datalogger</strong><br />
Set sampling time is to 0 second; Press the REC Button, and the “REC” symbol will appear on the LCD screen. Press the Logger Button, and the “REC” symbol will flash once and one Beep will sound, at the same time the measuring data along the time information will be saved in memory. The lower Display will show the Position (record) number, which is saved as well. To Change the Position Number; press the Down Button and the lower position number will flash on the display. Press the Up or Down Buttons to set the Position Number (1 to 99) to help identify the measurement location. The lower Display will show P x (x = 1 to 99). After the position number is selected, press the Enter Button to confirm. Stop Datalogging; press the REC Button for 2 seconds, and the “REC” symbol will disappear indicating the Datalogging function has stopped.</p>
<table class="specsalt" style="height: 429px;" width="546">
<tbody>
<tr>
<td class="specstop" colspan="4"><strong>Specifications SD-4307</strong></td>
</tr>
<tr>
<td class="specs6">Conductivity Range</td>
<td class="specs5">200μS, 2mS, 20mS, 200mS</td>
</tr>
<tr>
<td class="specs6">Resolution</td>
<td class="specs5">0.1μS, 0.001mS, 0.01mS, 0.1mS</td>
</tr>
<tr>
<td class="specs6">Accuracy</td>
<td class="specs5">±(2% f.s. +1 digit)</td>
</tr>
<tr>
<td class="specs6">TDS Range</td>
<td class="specs5">200, 2000, 20,000, 200,000 ppm</td>
</tr>
<tr>
<td class="specs6">Resolution</td>
<td class="specs5">0.1, 1, 10, 100 ppm</td>
</tr>
<tr>
<td class="specs6">Accuracy</td>
<td class="specs5">±(2% f.s. +1 digit)</td>
</tr>
<tr>
<td class="specs6">Salinity Range</td>
<td class="specs5">0 to 12% salt (% weight)</td>
</tr>
<tr>
<td class="specs6">Resolution</td>
<td class="specs5">0.01% salt</td>
</tr>
<tr>
<td class="specs6">Accuracy</td>
<td class="specs5">±0.5% salt</td>
</tr>
<tr>
<td class="specs6">Sampling Time</td>
<td class="specs5">Auto, 1 second to 9 hours</td>
</tr>
<tr>
<td class="specs6">Power Supply</td>
<td class="specs5">6 x 1.5V UM3/AA batteries</td>
</tr>
<tr>
<td class="specs6">Dimensions</td>
<td class="specs5">177 x 68 x 45mm (7.0 x 2.7 x 1.9”)</td>
</tr>
<tr>
<td class="specs6">Weight</td>
<td class="specs5">515g (1.13 lb)</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://obiat.com.au/product/reed-sd-4307-conductivitytdssalinity-meterlogger/">Reed SD-4307 Conductivity/TDS/Salinity Meter/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-sd-4307-conductivitytdssalinity-meterlogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Reed SD-230 pH/ORP Meter/Logger</title>
		<link>https://obiat.com.au/product/reed-sd-230-phorp-meterlogger/</link>
					<comments>https://obiat.com.au/product/reed-sd-230-phorp-meterlogger/#respond</comments>
		
		<dc:creator><![CDATA[slickadmin]]></dc:creator>
		<pubDate>Mon, 15 Feb 2016 01:12:00 +0000</pubDate>
				<guid isPermaLink="false">http://sitebuilds.net/rapidtech/product/reed-sd-230-phorp-meterlogger/</guid>

					<description><![CDATA[<p><img class="alignnone size-full wp-image-980" src="http://obiat.com.au/wp-content/uploads/2016/02/reed-logo-red.jpg" alt="reed logo red" width="120" height="50" /></p>
<p>The SD-230 ORP and pH meter is a Reed real time datalogger with memory card slot. It features a large, easy-to-read LCD display and simple push-button operation. A powerful custom microprocessor LSI circuit and its last generation electronics allow the unit to provide features such as a pH range which is from 0 to 14.00pH. Reed SD-230 can measures and records the values of measurements for a later analysis with a computer. The gage has a good configurable sampling time, from 1 second to 3600 seconds and is compatible with any pH Electrode with a BNC connector. An easy to read LCD display with backlight shows the humidity and temperature simultaneously</p>
<p><strong>REED SD-230 Features</strong></p>
<ul class="gkCircle2">
<li>Meter can select between ATC or manual temperature adjustment</li>
<li>Three Point Calibration</li>
<li>Accepts any pH Electrode with a BNC connector</li>
<li>Real time SD memory card datalogger with a built-in clock and<br />
calendar</li>
<li>Sampling time set from 1 second to 3600 seconds</li>
<li>Meter can switch to a Manual Datalogging</li>
<li>No extra software needed, just plug the SD card into the computer<br />
and it downloads directly to EXCEL</li>
<li>SD card capacity: 1 GB to 16 GB</li>
<li>Easy to read LCD with backlight</li>
<li>Auto power off or manual power off</li>
<li>Data hold, record max. and min. reading</li>
<li>High accuracy microcomputer circuit</li>
<li>Power by UM3/AA (1.5 V) x 6 batteries</li>
<li>USB/RS232 Computer interface</li>
</ul>
<p><strong>Authorised Australian Distributor</strong></p>
<p><img class="alignnone wp-image-2716" src="http://obiat.com.au/wp-content/uploads/2016/03/1-Year-Warranty.jpg" alt="1 Year Warranty" width="142" height="84" /></p>
<p>&#160;</p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-230-phorp-meterlogger/">Reed SD-230 pH/ORP Meter/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4 class="title">How to use Reed SD-230 pH and ORP Meter</h4>
<p><strong>pH Measurements (Manual Temp. Compensation)</strong><br />
Turn on this data logger by pressing the Power Button and connect the Optional pH Electrode into the pH/BNC SD-230&#8217;s socket. Before taking measurements you need to <strong>Set the pH Manual Temperature Compensation value</strong>. Press and hold the SET Button for 2 seconds to enter the “Advanced Setting” mode. Press the Next Button scroll through eight main functions, shown on the lower display until the &#8220;t-Set&#8221; icon appear. When the lower display shows “t-SEt “, use the Up or Down Buttons to select the upper value to the desired Temperature Compensation value. The default value is 25°C (77°F). Press the Enter Button to save the setting as the default. Now you can exit “Advanced Settings” by pressing the Esc Button.<br />
Hold the Electrode Handle and let the Sensing head get fully immersed the measured solution. Shake the pH Electrode to let the probe’s internal air bubble drift out from the sensing head. The top display will show the pH value and the bottom display will show the setting for the Manual Temperature Compensation value.</p>
<p><strong>pH Measurements (ATC)</strong><br />
For pH measurements you need to plug in the optional Temperature Probe into the Temperature Socket. Plug in the optional pH Electrode into the pH/BNC Socket. Immerse both the Temperature Probe and the pH Electrode into the measured solution. Shake the pH Electrode to let the probe’s internal air bubble drift out from the sensing head. The top display will show the pH value and the bottom display will show the measured Temperature.</p>
<p><strong>mV Measurements</strong><br />
This instrument comes with an built in mV (millivolt) measurement function. This feature enables you to make ion-selective, ORP (oxidation-reduction potential), and other precise mV measurements. All of these measurements are easy to made and start when you will push down the &#8220;function button&#8221; so the unit switches from “pH” to “mV”. To return to pH measurements, press the Function Button again. Connect the optional ORP Electrode Plug into the pH/BNC Socket. 3) The Display will show the mV value.</p>
<p><strong>How to use Data hold and Data record functions</strong><br />
You can hold on the measured values any time while taking a measurement by pressing the Hold Button once. Press the Hold Button once again will release the data hold function. To <strong>record the maximum and minimum pH or ORP readings, </strong>press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display.</p>
<table border="0" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" align="center" width="100%">
<p align="left"><span style="font-size: medium;">Specifications</span></p>
</td>
</tr>
<tr>
<td colspan="2" align="center" width="100%">
<div align="center">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> pH Ranges</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> 0.00pH to 14.00pH</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Resolution</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> 0.01pH</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Accuracy</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> ±(0.02pH of reading + 2 digits)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> mV Range</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> -1999mV to +1999mV</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Resolution</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> 1mV</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Accuracy</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> ±(0.05% of full scale + 2 digits)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Sampling Time</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> Auto, 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Memory Card</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> SD memory card, 1GB to 16GB</span></td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td colspan="2" align="center" width="100%"></td>
</tr>
<tr>
<td colspan="2" align="center" width="100%">
<p align="left"><span style="font-size: medium;"> General Specifications</span></p>
</td>
</tr>
<tr>
<td colspan="2" align="center" width="100%">
<div align="center">
<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Power Supply</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> Six (6) type &#8216;AA&#8217; 1.5-Volt Alkaline Batteries</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Dimensions</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> 177mm (L) x 68mm (W) x 45mm (D)</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Weight</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> 489g</span></td>
</tr>
</tbody>
</table>
</div>
</td>
</tr>
<tr>
<td colspan="2" align="center" width="100%"></td>
</tr>
<tr>
<td colspan="2" align="center" width="100%">
<table border="1" width="100%" cellpadding="0">
<tbody>
<tr>
<td colspan="2" bgcolor="#ffffff"><span style="font-size: medium;"> Ordering Information</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed SD-230</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> pH &#8211; ORP Meter/Data Logger</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed PE-01</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> pH Electrode</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed PE-03</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> pH Electrode</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed PE-11</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> pH Electrode</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed ORP-14</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> ORP Electrode</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed PH-04</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> 4.0 pH Buffer Solution</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed PH-07</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> 7.0 pH Buffer Solution</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed TP-07</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> ATC Temperature Probe</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed BS-6</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> Tripod</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed CA-05A</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> Soft Carrying Case</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed SD-2GB</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> 2GB SD Memory Card</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed USB-01</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> USB Cable</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed UPCB-01</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> RS-232 Cable</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed SW-U801-WIN</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> Data Acquisition Software</span></td>
</tr>
<tr>
<td valign="top" bgcolor="#876b8b" width="27%"><span style="color: #ffffff;"> Reed CERTIPH1</span></td>
<td bgcolor="#3c809f" width="73%"><span style="color: #ffffff;"> Accredited Calibration Certificate</span></td>
</tr>
</tbody>
</table>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a href="https://obiat.com.au/product/reed-sd-230-phorp-meterlogger/">Reed SD-230 pH/ORP Meter/Logger</a> appeared first on <a href="https://obiat.com.au">Obiat Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://obiat.com.au/product/reed-sd-230-phorp-meterlogger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>