The FLIR VT8-600 and VT8-1000 Voltage-Current-Continuity Open Jaw Testers
are your go-to troubleshooting electrical testers.
RUGGED AND SAFE
Made with the quality and reliability you have come to expect from FLIR test and measurement tools
• Work more safely with the CAT IV safety ratings
• Safely store test leads when not in use with the built-in test lead holder
• Keep the test leads out of your way when you’re not using them – the length is short enough to minimize interference, yet long enough to get the job done.
RICH FEATURES
Equipped with the capabilities you need including True RMS, AC/DC voltage and current, continuity, resistance, and capacitance
• Measure True RMS AC/DC voltage and current, continuity, resistance, and capacitance
• Work efficiently in dimly lit areas using the bright LED worklight and backlit display
• Detect live AC voltages with the built-in non-contact voltage (NCV) detector
• Improve accuracy of readings with True RMS measurements
• The VT8-600 has a CAT III-600 V/CAT IV-300 V safety rating and a 100A/600V measuring range.
• The VT8-1000 has a CAT III-1000 V/CAT IV-600 V safety rating and a 200A/1000V measuring range.
FLEXIBLE, EASY TO USE
Designed for long, trouble-free operation so you can focus on the task at hand
• Take measurements in tight spaces with the optimized jaw design, and measure large-diameter cables with the wide jaw opening
• Operate the meter with one hand thanks to the compact, ergonomic design
• View information easily at any distance on the large multi-function LCD display
FLIR VT8-600 & FLIR VT8-1000 Specifications:
VT8 Model |
VT8-600 |
VT8-1000 |
| Electrical Measurement | ||
| True RMS Voltage and Current | Yes | |
| Auto-Ranging | Yes | |
| AC/DC Current Range | 100 A | 200 A |
| AC/DC Current Resolution | 0.1 A | |
| AC (50 to 60 Hz) / DC Current Accuracy | ±2.5% | |
| AC/DC Voltage Range | 600 V | 1000 V |
| AC/DC Voltage Resolution | 0.1 V | |
| AC (45 to 66 Hz) / DC Voltage Accuracy | ± 1.5%, ±1.0% | |
| Resistance | 60.00 MΩ ± (1.5%) | |
| Continuity Check Threshold | 10 Ω to 100 Ω | |
| Capacitance | 600 μF ±4.0%, 6000 μF ±10.0% | |
| Non-Contact Voltage Detector (NCV) | ≥100 Vrms; ≤10 mm distance (LED/buzzer alerts) | |
| Additional Measurement Functions | DCA zero, relative mode (AC/DC voltage, AC current, and capacitance), data hold | |
| General | ||
| Worklights | White LED | |
| Jaw Opening | 15.5 mm (0.61 in) | |
| Display | 6000-count backlit multi-function LCD | |
| Display Rate | Approximately 3 times per second | |
| Polarity | Automatic display of positive and negative polarity | |
| Over-Range Indication | “OL” or “-OL” displayed | |
| Auto Power Off | After 15 minutes | |
| Power Source | 2 x AA alkaline batteries | |
| Low battery Indication | Battery symbol is displayed when batteries need changing | |
| Environmental Data | ||
| Operating Temperature | -10 to 50°C | |
| Relative Humidity | 95% max; 5 to 30°C, 75% max; 30 to 40°C, 45% max; 40 to 50°C | |
| Storage Temperature | -30 to 60°C (-22 to 140°F), batteries not installed | |
| Drop Test | 2 m (6.6 ft) | |
| Physical Data | ||
| Dimensions: (W × H × D) | 210 mm × 53 mm × 35 mm | |
| Weight | 163.7 g including batteries | |
| General Information | ||
| Warranty | Limited 3-year | |
| Certifications | C-UL-US, CE, RCM | |
| Safety Category Rating | CAT IV-300 V | CAT IV-600 V |
| CAT III-600 V | CAT III-1000 V | |
| EN 61010-1 | ||
| EN 61010-2-032 | ||
| EN 61010-2-033 | ||