Functions DMM Section
- DC Voltage.
- AC True RMS Voltage.
- AC True RMS Current with External Clamp.
- AC True RMS Leakage Current with external clamp (optional).
- DC Current.
- Resistance.
- Continuity test with buzzer.
- Frequency with test leads.
- Frequency with External Clamp.
- MIN/MAX/ AVG functions.
- PEAK function with response time 1ms.
- HOLD function.
Safety Test Section
- Continuity test (200mA) of protective conductors.
- Insulation Resistance measurement (500V DC).
- Trip-out time of RCD type AC Standard with test current of 30mA, 30 x 5mA, 100mA, 300mA.
- Global Earth Resistance with RCD tripping.
- Phase sequence indication at 1 or 2 wires.
- Phase coincidence indication at 1 or 2 wires.
- Leakage current (with HT96U optional clamp + NOCANBA connector).
- AUTOTEST function: automatic sequence test of Global Earth Resistance + RCD test + Insulation test with OK, NOT OK indicates LAN SECTION..
LAN Section
- Test executed on twisted pair cables UTP and STP with RJ45 connector.
- Wire mapping control of following conditions: OPEN, SHORT, CROSS, REVERSE, SPLIT, MISWIRE message at display.
- Quick selection of cable pairs.
- Automatic detection of remote control units (from #1 to #8).
- AutoPower OFF.
- Low battery indication
Included Accessories
- HT4003: 400A AC Current clamps.
- C2075: Two terminal cable with SHUKO plug.
- KIT0075: Set of 2 cables with test leads + 2 alligator clips.
- No2 Remote identifier #1, #2.
- No3 Patch cables, 30cm, RJ45 connectors.
- BORSA75: carrying bag.
- Calibration certificate ISO9000.
- Instruction manual.
- Warranty card.
Optional Accessories
- HT96U 1-100-1000A/1V leakage current clamp (jaw opening 54mm max. dia.).
- NOCANBA adapter (for connection to HT96U clamp).
- REM38 No.6 Remote identifier unit #3, #4, #5, #6, #7, #8.
- REM3 remote unit #3 + connection cable RJ45-RJ45.
- REM4 remote unit #4 + connection cable RJ45-RJ45.
- REM5 remote unit #5 + connection cable RJ45-RJ45.
- REM6 remote unit #6 + connection cable RJ45-RJ45.
- REM7 remote unit #7 + connection cable RJ45-RJ45.
- REM8 remote unit #8 + connection cable RJ45-RJ45.
General Specifications | |
Display | Dual numeric, 9999 counts (73mm x 73mm) |
Display Update | 2 times/second |
Conversion | 16 Bit, AC True RMS |
Sample Frequency | 64 samples/period |
Insulation | class 2 (double insulation) |
Pollution Degree | 2 |
Overvoltage Category | CAT III 550V AC Phase to Ground CAT III 550V AC Phase to Phase |
Reference Standards | CE mark |
EN 61557-4 Continuity Test | |
EN 61557-2 Insulation Resistance | |
EN 61557-5 Earth Resistance | |
EN 61557-6 RCD Test | |
EN 61326 EMC Standards | |
EN 61008 | |
EN 61009 | |
Power Supply | 4 x 1.5 Volt type ‘AA’ alkaline batteries LR6, AM3, MN 1500 |
Dimensions | 240mm (L) x 100mm (W) x 45mm (D) |
Weight | approx. 630g (including batteries) |
Reviews