HTI EV-TEST100 Features
- Use for EVSE stations with charging modes 2 and 3
- Test cable with Type 2 connectors (IEC 62196-2)
- Vehicle simulation via Control Pilot system (CP state)
- Cable current capacity simulation via Proximity Pilot system (PP state)
- Fault PE simulation condition
- Fault condition simulation on the Control Pilot (Fault E)
- Efficiency check of internal station energy meter (LOAD section)
- LED indications for system phase detection
- Terminals for connection to HT tester
- Protection fuse on LOAD section
- Test in compliance with IEC/EN61851-1 and IEC/EN60364-7-722 guidelines
Measurement functions
- Universal 4mm sockets for connection to a 1- or 3-phase installation tester using test leads (banana plugs)
- Separate phase display with three LEDs for easy voltage checking
- Proximity Pilot (PP) rotary switch for simulating different current carrying capacities of charging cables
- Control Pilot (CP) rotary switch for simulating the electrical vehicle status A, B, C D
- Rotary switch error to simulate a short circuit between CP and PE (state E = error)
- Simulation of PE fault (ground fault)
- Connection for the CP signal output to check communication between the adapter (= simulated electric vehicle) and the charging station
- Type 2 plug for connection to the charging station even with a permanently connected charging cable
- Vehicle simulation (CP): The various vehicle states A to D can be simulated using a rotary switch (according to IEC 61851)
- Cable simulation (PP): The various codings for charging cables with 13, 20, 32 and 63 A as well as “no cable connected” can be simulated using a rotary switch
- Error simulation: Simulation of a short circuit between CP and PE using a rotary switch (state E = error)
- Display of phase voltages via LEDs
- Testing of e-charging stations even with a permanent
- connected charging cable
- For vehicle simulation (CP):
According to IEC 61851, the states A, B, C, D and E can be simulated. The various vehicle states are set using the rotary switch.
HTI EV-TEST100 Functions
| Use for EVSE charging stations | Charging modes 2 and 3 |
| Test cable with connector | Type 2 (IEC 62196-2) |
| Vehicle simulation via Control Pilot (CP state) | States A, B, C, D |
| Simulating the current capacity of Proximity Pilot (PP state) | NC, 13A, 30A, 32A, 63A |
| Fault condition simulation on PE | FAULT PE |
| Diode simulation in short circuit | FAULT E |
| EVSE internal counter efficiency check | LOAD |
| Input voltage | Max 415V AC, Phase-Phase, 50 / 60Hz |
| External load L-N-PE | 240V 50/60Hz, Max 10A AC |
| CP signal | PWM 12V |
| External load protection | Fuse FF 10A / 250V, 5x20mm |
| Operating temperature | 0°C ÷ 40°C |
| Operating humidity | <80&RH |
Guidelines
- IEC/EN60364-7-722
- IEC/EN61010-1
- IEC/EN61851-1